HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property Organization 7119 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGA( Builder GL188B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188B Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,189 $174 $333 $1,696 $662 $0 $2,358 Requirements C", Energy Solutions As Designed $973 $149 $333 $1,455 $662 $0 $2,117 Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 14.2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectecnested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 6117119 at 9:24 PM Ekotrope RATER - Version 3.1.0.2196 IECC 2009 Performance compliance results calculated using Ekotrope RATER's anergy and code compliance algorithm. Ekotrope RATER is a RESNr7T Aocred ited HERS Rating Tool. All resuis are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the in for m atio n s how n on this report. 405.3 Performance-based compliance passes by 14.2°/ R402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration 5HGC 402.5 Area -weighted average fenestration U -Factor 403.2.2 Duct Testing Q Mandatary Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation C", Energy Solutions As Designed $973 $149 $333 $1,455 $662 $0 $2,117 Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 14.2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectecnested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 6117119 at 9:24 PM Ekotrope RATER - Version 3.1.0.2196 IECC 2009 Performance compliance results calculated using Ekotrope RATER's anergy and code compliance algorithm. Ekotrope RATER is a RESNr7T Aocred ited HERS Rating Tool. All resuis are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the in for m atio n s how n on this report. 7119 Antiquity Dr CARMEL, IN 46033 Builder: PYATT BUILDERS, LLC Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-13.0, Return R-9.0 Duct Leakage to Outside 97.0 CFM @ 25Pa Total Duct Leakage 570.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter Q of the adopted International Energy Conservation Code based on Climate Zane 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Organization: Michael Hill TSI Energy Solutions Signature: Date: 6117119 at 9:24 PM Ekotrope RATER - Version 3.1.0.2196 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETA—sdlted HERS Rating Tool. All results are based on data entered by Ekotrope users, Ekotrope disclaims all liability forthe information shown on this report. Energy Code Inspection Checklist Property Organization 7119 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGA( GL188B (AS DESIGNED) THE GROVE AT LEGACY 188B General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Builder PYATT BUILDERS, LLC 2,501 22,508 6,215 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (1,844 s.f.) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall Name: COND/AMB (1,740 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III Name: COND/GAR (410 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III Name: COND/ATTIC (7 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III Name: COND/COND (370 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: III Energy Code Inspection Checklist Property 7119 Antiquity Dr CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGA( GL188B (AS DESIGNED) THE GROVE AT LEGACY 188B Rim Joist None Present Roof Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Name: MAIN (1,844 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (158 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH El Name: BACK (47 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH El Name: SLIDER (64 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST El Name: RIGHT (119 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST Skylight None Present Mechanical Ventilation None Present C", Energy Solutions Mechanical Equipment 2 Energy Code Inspection Checklist Property Organization Inspection Status 7119 Antiquity Dr TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGA( Builder GL188B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188B Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE Air conditioner • Electric • 100% Cooling Load @ 13 SEER Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 1,876 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 97.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 570.0 CFM @ 25Pa C", Energy Solutions Energy Code Inspection Checklist Property Organization 7119 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGA( Builder GL188B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188B Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 1100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 1100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 1100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 7119 Antiquity Dr CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGACY 1888 GL188B (AS DESIGNED) THE GROVE AT LEGACY 188B General Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq. ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Organization TSI E nerg y S olution s 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC 3 2 2, 501 Yes 22,50B 1 Duplex, single unit DURHAM THE GROVE AT LEGACY 188B 5A None Present Foundation Wall Library List None Present Slab Name Library Type Perimeter Floor Grade Inspection Status Results are projected C",Erergy Solutions AM Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB R-10, 1'down, 2' in 215 On Grade 1.23 0 1,844.0 sq. ft. Exposed Exterior Conditioned Space Slab Library UstA��Miii amom Name Wall Construction Slab ComplatelV Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, 2' in Wood Frame IOther No 2 1 10 No 1D.DD Framed Floor None Present 1 Building Summary Property Organization 7119 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Madel: DURHAM Michael Hill Community: THE GROVE AT LEGACY 1888 Location CONDIAMB Builder GLI 88B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 1888 G3 R-15 BATT, OSB Framed Floor Library List E&M CONDIATTIC None Present Rim Joist Attic None Present Rim Joist Library List None Present CTMEnergy Solutions Inspection Status Results are projected Wall 7w■ Name Library Type Surface Color Surface Area Location CONDIAMB Exposed Exterior G3 R-15 BATT, OSB Medium 1,740.0 sq. it, CONDIATTIC Attic G3 R-15 BATT, OSB Medium 7.0 sq. it, CONDICOND Conditioned Space (Adiabatic) 03 R-22 Dbl Wall Medium 370.0 sq. ft. CONDIGAR Unconditioned, attached garage G3 R-15 Gar Walls Medium 410.0 sq. ft. Wall Library List Name Effective R -value G3 R-15 BATT, OSB 12.293 03 R-15 Gar Walls 10.683 G3 R-22 Dbl Wall 15.364 2 Building Summary Property Organization Inspection Status CTMEnergy Solutions 7119 Antiquity Dr TSI Energy Solutions Results are projected CARMEL, IN 46033 317-646-4655 Madel: DURHAM Michael Hill Community: THE GROVE AT LEGACY 1888 Builder GLI 88B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 1866 Glazing Name Library Type Wall Assignment Foundation Wall Overhang Assignment Depth Overhang Ft To Overhang Top Ft To Orientation Bottom Surface Area BACK U-.31, SHGC-.28 CONDIAMB ❑ 0 ❑ North 47.0 sq. ft. FRONT U-.31, SHGC-.28 CONDIAMB ❑ 0 ❑ South 156.0 sq. ft. RIGHT U-.31, SHGC-.28 COND/AMB ❑ 0 ❑ East 119.0 sq. ft. SLIDER U-.31, SHGC-.28 CONDIAMB 0 0 ❑ East 64.0 sq. ft. Glazing Library List Name Shgc L11 -factor IU-.31, SHGC-.26 G.28 0.310 Skylight Skylight Library List Opaque Door Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assl g n m ent Abso rptan ce FRONT Fiberglass Door CONDiAMB 0.9 0.75 Medium 20.0 sq. ft. Exposed Exterior GARAGE Fiberglass Door CCND/GAR 0.9 0.75 Medium 16.0 sq. ft. Exposed Exterior Building Summary Property Organization 7119 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Madel: DURHAM Michael Hill Community: THE GROVE AT LEGACY 1888 Builder GLI 88B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 1868 Opaque Door Library List Name Effective U -factor Fiberglass Door 0.182 Roof Insulation Name MAIN R-38 Blown. GRI Inspection Status Results are projected CTMEnergy Solutions 1,844 No Medium 1,844.0 sq. ft. Attic Roof Insulation Library List 01 Name Has Radiant Barrier R-38 Blown, GRI No Whole House Infiltration Infiltration Measure me nt Type 5 ACH at 50 Pa Blower -door tested I Mechanical Ventilation None Present Lighti % Interior 38.268 Shelter Class 4 9 79 U 0 0 ❑ 0 4 Building Summary Pro perty 7119 Antiquity Dr CARMEL, IN 45033 Model: DURHAM Community: THE GROVE AT LEGACY 1888 GLI 88B (AS DESIGNED) THE GROVE AT LEGACY 1868 Onsite Generation Organization TSI E nerg y S olution s 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Air conditioner Fuel -fired air distribution Water Heating CA13NA042 912SA4808DS17 RE350" Equipment Type: 912SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG [Single Speed] Heating Efficiency 92.1 AFUE Heating Capacity [kBtufh] 78 Use default EAE No EAE [kWh] 977 Inspection Status Results are projected 0% 100% 0% ng Percent wat 100% D% 4% CTMEnergy Solutions 0°% VI6 100% .7 Building Summary Pro perty 7119 Antiquity Dr CARMEL, IN 45033 Model: DURHAM Community: THE GROVE AT LEGACY 1888 GLI 88B (AS DESIGNED) THE GROVE AT LEGACY 1868 Equipment Type: CA13NA042 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] M ' Equipment Type: RE350* Organization TSI E nerg y S olution s 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Electric Forced Air PSC (Single Speed) 13 SEER 40 Inspection Status Results are projected Fuel Type Electric Distribution Type Hydranic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtu/h] 15.4 Recovery Efficiency 0.98 CTMEnergy Solutions Building Summary Property Organization Inspection Status 7119 Antiquity Dr TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGACY 1888 2 Supply Duct R Value Builder GLI 88B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 1888 675.27 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 2501 # Return Grilles 2 Supply Duct R Value 13 Return Duct R Value 9 Supply Duct Area [sq. ft.] 675.27 Retum Duet Area [sq. ft.] 250.1 Duct Leakage to Outdoors (CFIM 25) 97 Total Leakage 570 Total Leakage Duct Test Conditions Past -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 30 Percent Return Area 30 Duct 2 Duct Location Attic (well vented, under insulation) Percent Supply Area 65 Percent Return Area 40 Duct 3 Duct Location Attic (well vented) Percent Supply Area 5 Percent Return Area 30 Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan Has Ceiling Fan No Cfm Per Watt 100 Water Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Standard No 60 No No 10 No CTMEnergy Solutions VA Building Summary Pro perty 7119 Antiquity Dr CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGACY 1888 GLI 88B (AS DESIGNED) THE GROVE AT LEGACY 1888 Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption NMS Organization TSI E nerg y S olution s 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Electric 2.617 Timer Controls 704 kWhNear $0.08/kWh $23.00 $0.581Therm 2.874 0.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year Inspection Status Results are projected CTMEnergy Solutions