HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance
Property Organization
7104 CHERRY CREEK BLVD TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: SAUSALITO Michael Hill
Community: THE GROVE AT LEGA[
Builder
GL200A (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200A
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$888
$129
$263
$1,280
$635
$0
$1,915
Requirements
C-M,
Energy Solutions
As Designed
S817
$154
$263
$1,233
5628
s0
$1,861
C4405.3 Performance-based compliance passes by 3.19%
R402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 3.6%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
6113119 at 8:22 AM
Ekotrope RATER - Version 3.1.0.2194
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
7104 CHERRY CREEK BLVD
CARMEL, IN 46033
Builder: PYATT BUILDERS, LLC
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 5 ACH50
Window U -Value: 0.31, Sll 0.32
Building Features
Duct Supply R-25.0, Return R-25.0
Duct Leakage to Outside 96.0 CFM @ 25Pa
Total Duct Leakage 128.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected. I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed. I certify that the address referenced above has been inspectetlrtested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the I ECC cr will be venfied as such by another party.
Name
Organization
Michael Hill
TSI Energy Solutions
Signature:
Date:
6113119 at 8:22 AM
Ekotrope RATER -Version 3.1.0.2194
2009 l compliance results calculated using Ekotrope RATER's energy and code cnmptance algorithm_
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh— on this report.
Energy Code Inspection Checklist
Property Organization
7164 CHERRY CREEK BLVD TSI Energy Solutions
CARMEL, IN 46633 317-846-4655
Model: SAUSALITO Michael Hill
Community: THE GROVE AT LEGA(
GL266A (AS DESIGNED)
THE GROVE AT LEGACY 266A
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Builder
PYATT BUILDERS, LLC
1,647
16,349
5,724
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (1,647 s.f.)
R-16 perimeter insulation, R-16 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (1,566 s.f.)
R-6 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (378 s.f.)
R-6 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDICOND (387 s.f.)
R-6 continuous insulation, R-22 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (99 s.f.)
R-3 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
7104 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: SAUSALITO
Community: THE GROVE AT LEGA[
GL200A (AS DESIGNED)
THE GROVE AT LEGACY 200A
Rim Joist
None Present
Roof
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Name: MAIN (1,647 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT (80 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
El Name: BACK (59 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH
El Name: SLIDER (128 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH
El Name: LEFT SIDE (101 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST
11 Name: RIGHT SIDE (83 s.f.), U:0.310, SHGC: 0.32, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property Organization Inspection Status
7104 CHERRY CREEK BLVD TSI Energy Solutions Results are projected
CARMEL, IN 46033 317-846-4655
Model: SAUSALITO Michael Hill
Community: THE GROVE AT LEGA(
Builder
GL200A (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200A
ElMechanical ventilation system rated for, and capable of, providing continuous ventilation.
System shall include automatic timing controls.
System type: Exhaust Only, 24 hrslday, 9 Watts.
Mechanical Equipment
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AF UE
0 Air conditioner • Electric • 100% Cooling Load @ 13 SEER
Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,279 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 96.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 128.0 CFM @ 25Pa
C",
Energy Solutions
Energy Code Inspection Checklist
Property Organization
7104 CHERRY CREEK BLVD TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: SAUSALITO Michael Hill
Community: THE GROVE AT LEGA(
Builder
GL200A (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200A
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
7104 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: SAUSALITO
Community: THE GROVE AT LEGACY 200A
GL200A [AS DESIGNED]
THE GROVE AT LEGACY 200A
Genera?Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq_ ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Floor Number
Model
Community
Climate Zone
Foundation Wall
Foundation Wall Library List
Slab
Organization Inspection Status
TSI Energy Solutions Results are projected
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
2
1
1;647
Yes
15;349
1
Duplex; single unit
SAUSALITO
THE GROVE AT LEGACY 200A
5A
None Present
None Present
Masonry Area
C-M,
Energy Solutions
n
SLAB R-10, 2'down, 2' in 216
On Grade 1.23
0 1,647.0 sq. R.
Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction Slab Completel Underslab Perimeter
Perimeter
Thermal Break Effective R -value
Type Insulated. Insulation
Width [ft] Insulation Depth [ft]
Insulation R Value
R-10, 2'down, 2' in Wood Frame /Other No
2 2
10
No 10.00
Framed Floor
None Present
1
Building Summary
Property
Organization
7104 CHERRY CREEK BLVD
TSI Energy Solutions
CARMEL, IN 46033
317-846-4655
Model: SAUSALITO
Michael Hill
Community: THE GROVE AT LEGACY 200A
Builder
GL200A [AS DESIGNED]
PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200A
1,566.0 sq. ft.
Framed Floor Library List
None Present
Rim Joist
Rim Joist Library List _
None Present
Wall
Inspection Status
Results are projected
C-M,
Energy Solutions
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
Exposed Exterior
G1 R-15 BATT, OSB
Medium
1,566.0 sq. ft.
CONDIATTIC
Attic
G1 R-15 BATT, R-3.0
Medium
99.0 sq. ft.
CONDICOND
Conditioned Space [Adiabatic]
G1 R-22 Dbl Wall
Medium
387.0 sq. ft.
CONDIGAR
Unconditioned, attached garage
G1 R-15 Gar Walls
Medium
378.0 sq. ft.
Wall Library List
Name
Effective R value
G1 R-15 BATT, OSB
13.423
G1 R-15 BATT, R-3.0
16.138
G1 R-15 Gar Walls
11.972
G1 R-22 Dhl Wall
18.407
2
Building Summary
Name Library Type Wall Assignment Foundation Wall
Emittance Solar Surface Color
Property
Organization
Inspection
Status
C-MEnergy
Solutions
7104 CHERRY CREEK BLVD
TSI Energy Solutions
Results are projected
0.9 0.75 Medium
20.0 sq_ ft
GARAGE Steel Door CONDIGAR
CARMEL, IN 46033
317-846-4655
Exposed Exterior
0.9 0.75 Medium
18.0 sq_ ft
Model: SAUSALITO
Michael Hill
Community: THE GROVE AT LEGACY 200A
Builder
GL200A [AS DESIGNED]
PYATT BUILDERS, LLC
THE GROVE AT LEGACY 2DOA
FGlazing
Name Library Type WaIT Assignment Foundation Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK U-.31, SHGC-.32
CONDIAMB
❑
❑
❑
South
59.0 sq. ft
FRONT U-.31, SHGG.32
CONDIAMB
❑
❑
❑
North
80.0 sq. ft
LEFT SIDE U-.31, SHGG.32
CONDIAMB
0
❑
❑
West
101.0 sq. R.
RIGHT SIDE U-.31, SHGG.32
CONDIAMB
❑
❑
❑
East
83.0 sq. ft
SLIDER U-.31, SHGG.32
CONDIAMB
0
0
0
South
128.0 sq. R.
Glazing Library List
Name
Shgc
U -factor
U-.31, SHGC-.32
0.32
0.31 ❑
Skylight
None Present
Skylight Library List
None Present
Opaque Door
Name Library Type Wall Assignment Foundation Wall
Emittance Solar Surface Color
Surface Area
Location
Assignment
Ab sorpta n ce
FRONT Steel Door CONDIAMB
Exposed Exterior
0.9 0.75 Medium
20.0 sq_ ft
GARAGE Steel Door CONDIGAR
Exposed Exterior
0.9 0.75 Medium
18.0 sq_ ft
Building Summary
Property
7104 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: SAUSALITO
Community: THE GROVE AT LEGACY 200A
GL200A [AS DESIGNED]
THE GROVE AT LEGACY 200A
F4paque Door Library List
Name
Steel Door
Roof Insulation
Has Radiant Barrier
Name
Library Typ
ktAIN
R-38 Blown. GRI
Roof Insulation Library List
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
0.182
Inspection Status
Results are projected
r Area Clay or Concrete Roof
Vt.] Tiles
1,647 No
Name
Has Radiant Barrier
R-38 Blown, GR1
No
Whale House Infiltration
Infiltration
Measurement Type
5 ACH at 50 Pa
Blower -door tested
Mechanical Ventilation
Ventilation Type Ventilation Rate [Cubic Feet Operational hours per day
!Minute]
Exhaust Only
20 24
Lighting
Interior Fluorescent
Lighting
0
38268
Shelter Class
4
C-M,
Energy Solutions
:e Color Surface Area Location
Medium 1,647.0 sq. ft Attic
Fan Watts Runs once every three Energy Recovery Percent
hours
9 Yes
0
■
■
4
Building Summary
Property Organization
7104 CHERRY CREEK BLVD TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: SAUSALITO Michael Hill
Community: THE GROVE AT LEGACY 200A
Builder
GL200A [AS DESIGNED] PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200A
nsite Generation
None Present
Onsite Generation Library List M
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipmenl
Name
Air conditioner
Fuel4red air
distribution
Water Heating
C-M
Energy Solutions
Inspection Status
Results are projected
g Percent Load Hot water
CA13NA048 0% 10D%
9125A48060917 100% 0%
0%
0%
ENT 50 100 0% 0% 100%
Equipment Type: 912SA48060S17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 56
Use default EAE No
EAE [kWh] 649
:j
Building Summary
Property
7104 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: SAUSALITO
Community: THE GROVE AT LEGACY 200A
GL200A [AS DESIGNED]
THE GROVE AT LEGACY 200A
■
quipment Type:
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
GA13NA048
."
Equipment Type: ENT 50 100
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Electric
Forced Air
PSC (Single Speed)
13 SEER
45.5
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
7104 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: SAUSALITO
Community: THE GROVE AT LEGACY 200A
GL200A [AS DESIGNED]
THE GROVE AT LEGACY 200A
1butivn System
tion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
]uct R Value
Xct Area [sq. ft.]
]uct Area [sq. ft_]
akage to Outdoors (CFM25)
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Ctm Per Watt
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Forced Air
Fuel -fired air distribution
Air conditioner
1647
1
25
25
444.69
82.35
96
128
Post -Construction
Yes
Conditioned Space
5
5
Attic (well vented; under insulation)
95
95
Attic (well vented)
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
7104 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: SAUSALITO
Community: THE GROVE AT LEGACY 200A
GL200A [AS DESIGNED]
THE GROVE AT LEGACY 200A
ater Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
r
es Dryer
e
zation
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmabie thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
FV I
Organization Inspection Status
TSI Energy Solutions Results are projected
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Standard
No
25
No
No
10
No
Electric
Timer Controls
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
C-M,
Energy Solutions
,�