HomeMy WebLinkAboutCAMDEN WALK 67 - CW067 (AS DESIGNED)IECC 2009 Performance Compliance
Property
2751 SILVER OAKS DR
CARMEL, IN 46032
Model: CUSTOM
Community: CAMDEN WALK 67
CW067 (AS DESIGNED)
CAMDEN WALK 67
Organization
TSI Energy Solutions
Devin Sielschott
Builder
RICHARD CARRIGER
Co.
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
51,714
5249
$181
$2,945
$1,355
$0
$3,500
Requirements
C4405.3
Performance-based compliance passes by D.0%
R402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U -Factor
403.2.2
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R405.2
Duct Insulation
C-M,
Energy Solutions
As Designed
$1,754
$208
$182
$2,144
$1,355
$0
$3,499
Air sealing is 5.0D ACH at 50 Pa. It must not exceed 7.013ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 0%.
Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 615119 at 8:34 AM
Ekotrope RATER - Version 2.2.4.2188
IECC 2009 Performance compliance results calculated using Eketrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all1iabitityfor the information shown on this report.
2751 SILVER OAKS DR
CARMEL, IN 46032
Builder: RICHARD CARRIGER CO.
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor NIA
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.29, SHGC: 0.33
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 220.0 CFM @ 25Pa
Total Duct Leakage 440.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric - 13 SEER
Water Heating Water Heater • Natural Gas • 0.7 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 615119 at 8:34 AM
Ekotrope RATER - Version 2.2.4.2188
2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property Organization
2751 SILVER OAKS DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CUSTOM
Community: CAMDEN WALK 67 Builder
RICHARD CARRIGER
CW067 (AS DESIGNED) Co.
CAMDEN WALK 67
General Building Information
Conditioned Area (sq ft) 5,574
Conditioned Volume (cubic ft) 55,471
Insulated Shell Area (sq ft) 10,641
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT (2,787 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
El Name: CONDIAMB (Exterior Perimeter [ft]: 80, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
] Name: CONDIAMB UN FIN (Exterior Perimeter [ft]: 139, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
]l Name: CONDIGARAGE UNFIN (Exterior Perimeter [ft]: 19, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wail to bottom of insulation: 4
Above Grade Wall
] Name: CCNDIAMB (2,301 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Energy Cade Inspection Checklist
Property
Organization
2751 SILVER OAKS DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: CAMDEN WALK 67
Builder
RICHARD CARRIGER
CW067 (AS DESIGNED)
CO.
CAMDEN WALK 67
Name: COND/GAR (190 s.f.)
R-0 continuous insulation, R-15
cavity insulation
Insulation Grade: I
Name: CONDIATTIC (177 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
1� Name: CON DIAMBRIM (219 s.f.)
1--1 R: 15.414
El Name: CONDIGARAGE RIM (19 s.f.)
R: 15.414
Roof
LA Name: MAIN (2,787 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
1� Name: FRONT (48 s.f.)
1--1 U: 0.476
El Name: GARAGE (24 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
11 Name: FRONT (64 s.f.), U: 0.290, SHGC: 0.33, Orientation: SOUTH
11 Name: BACK (209 s.f.), U: 0.290, SHGC: 0.33, Orientation: NORTH
Name: GO (24 s.f.), U: 0.290, SHGC: 0.33, Orientation: NORTH
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
TSI Energy Solutions
Property Organization Inspection Status
2751 SILVER OAKS DR TSI Energy Solutions Results are projected
CARMEL, IN 46032 Devin Sielschott
Model: CUSTOM
Community: CAMDEN WALK 67 Builder
RICHARD CARRIGER
CW067 (AS DESIGNED) Co.
CAMDEN WALK 67
Name: LEFT (11 s.f.), U: 0.290, SHGC: 0.33, Orientation: WEST
E] Name: RIGHT (75 s.f.), U: 0.290, SHGC: 0.33, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
1I HEATING • Natural Gas • 100% Heating Load @ 92.1 AFUE
El COOLING • Electric • 100°1% Cooling Load @ 13 SEER
[] Water Heating • Natural Gas • 100% Hot Water Load @ 0.7 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 4,623 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 220.0 CFM @ 25Pa 3
Total Duct Leakage is specified in Ekotrope at 440.0 CFM @ 25Pa
Energy Code Inspection Checklist
Property Organization
2751 SILVER OAKS DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CUSTOM
Community: CAMDEN WALK 67 Builder
RICHARD CARRIGER
CW067 (AS DESIGNED) CO.
CAMDEN WALK 67
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 3 CFM251 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization
Inspection Status
C-MEnergy
Solutions
2751 SILVER OAKS DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: CAMDEN WALK 67
Builder
RICHARD CARRIGER CO.
CWD67 [AS DESIGNED]
CAMDEN WALK 67
General Building Information
Number Of Bedrooms
4
Number Of Floors
1
Conditioned Floor Area [sq. ft.]
5,574
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
55,471
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
CUSTOM
Community
CAMDEN WALK 67
Climate Zone
5A
Foundation Wall
Name Library type
Height Above Grade Depth Below Grade Perimeter Location
Enclosing
CONDIAMB R-11 Draped, 4ft
1
8
80 Exposed Exterior
Conditioned Space
CONDIAMB UNFIN R-11 Draped, 4ft
1
8
139 Exposed Exterior
Conditioned Space
CONDIGARAGE R-11 Draped, 4ft
1
9
19 Exposed Exterior
Conditioned Space
UNFIN
Foundation Wall Library List
Name Feet From Wall Top To Feet
From Wall Top To Is Fully
Insulated Continuous R -value
Cavity R -value Effective
Insulation R -
Continuous Insulation Continuous
Insulation
value
Top
Bottom
R-11 Draped; 4ft 0
4
No
NIA NIA
11.00
Slab
Name Library type Perimeter Floor Grade
Carpet R Exposed
Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated
238 Below Grade
0 ❑
2,787.0 sq. ft. Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Slab Completelyx Underslab Perimeter Perimeter Thermal Break
Effective R -value
Type
Insulated. Insulation Width [R]
Insulation Depth [ft] Insulation
R Value
Uninsulated Wood Frame I Other
No 0
0
❑ No
0.00
1
Building Summary
Property
2751 SILVEROAKS DR
CARMEL, IN 46032
Model: CUSTOM
Community: CAMDEN WALK 67
CWD67 [AS DESIGNED]
CAMDEN WALK 67
Framed Floor
Organization
TSI Energy Solutions
Devin Sielschott
Builder
RICHARD CARRIGER CO.
Framed Floor Library List
None Present
Rim Joist
CONDIAMB RIM
CONDIGARAGE RIM
uorary rype
G1 R-19, OSB
C-M
Energy Solutions
Inspection Status
Results are projected
219.0 sq. R. Exposed Exterior
G1 R-19, OSB 19.0 sq. R. Unconditioned, attached garage
Rim Joist Library List
Name Effective Insulation R-valLie
G1 R-19. OSB 15.414
Name
CONDIAMB
Library Type
G1 R-15 BATT, OSB
Surface Color
Medium
Surface Area
2,301.0 sq. ft.
Location
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, OSB
Medium
177.0 sq. 11
Attic
CONDIGAR
G1 R-15 Gar Walls
Medium
1900.sq. 11
Unconditioned. attached garage
Building Summary
Property
Organization
Inspection Status
C-MEnergy
Solutions
2751 SILVER OAKS DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: CAMDEN WALK 67
Builder
RICHARD CARRIGER CO.
CWD67 [AS DESIGNED]
CAMDEN WALK 67
ll Library List
Name
Effective R -value
ra
G1 R-15 BATT. OSB
3
13.423
G1 R-15 Gar Walls
11.972
Glazing
Name Library 'Type Wall
Assignment Foundation Wall Overhang
Assignment
Depth Overhang Ft To Overhan
Tap
Ft To
Bottom
Orientation
Surface Area
BACK U-29, SHGC-.33
CONDIAMB
0 0
0
North
209.0 sq. ft.
FRONT U-29, SHGC-.33
CONDIAMB
0 0
0
South
64.0 sq. ft.
GD U-29, SHGC-.33
CONDIAMB
0 0
0
North
24.0 sq. ft.
LEFT U-29, SHGC-.33
CONDIAMB
0 0
0
West
11.0 sq. ft.
RIGHT U-29, SHGC-.33
CONDIAMB
0 0
0
East
75.0 sq. ft.
Glazing Library List
Name
Shgc
U -factor
U-29, SHGG.33
0.33
0290
Skylight
Skylight Library List
None Present
3
Building Summary
Property
Organization
Inspection Status
C-MEnergy Solutions
2751 SILVER OAKS DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: CAMDEN WALK 67
Builder
RICHARD CARRIGER CO.
CWD67 [AS DESIGNED]
CAMDEN WALK 67
Opaque Door
Name Library type Wal I Assi g n ment Fou ndatian Wall
Emittance Solar
Surface Color Surface Area Location
Assignment
Ab so rp to n ce
FRONT Wood Door
CONDlAMB
0.9 0.75
Medium 48.0 sq. 11 Exposed Exterior
GARAGE Fiberglass/Steel
CONDlGAR
0.9 0.75
Medium 24.0 sq. 11 Exposed Exterior
Door
■
Opaque Door Library List
Name
FiberglasslSteel Door
Wood Door
0.182
0.476
Raaf Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof
P.f.] Tiles
I•;IAIN R-38 Blown, GR1 2,787 No
Raaf Insulation Library List
Name Has
R-38 Blown, GR1
No
Whole House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
38268
Shelter Class
4
Medium 2.787.0 sq. ft. Attic
4
Building Summary
Property
2751 SILVEROAKS DR
CARMEL, IN 46032
Model: CUSTOM
Community: CAMDEN WALK 67
CWD67 [AS DESIGNED]
CAMDEN WALK 67
Mechanical Ventilation
Lighting
Interior Fluore
Lig
Organization
TSI Energy Solutions
Devin Sielschott
Builder
RICHARD CARRIGER CO -
Inspection Status
Results are projected
C-M,
Energy Solutions
0
Onsite Generation
0
Onsite Generation Library List
Solar Generation
Solar Generation Library List
None Present
None Present
None Present
0
0
0
5
Building Summary
Property Organization Inspection Status C-MEnergy Solutions
2751 SILVER OAKS DR TSI Energy Solutions Results are projected
CARMEL, IN 46032 Devin Sielschott
Madel: CUSTOM
Community: CAMDEN WALK 67 Builder
RICHARD CARRIGER CO.
CWD67 [AS DESIGNED]
CAMDEN WALK 67
Conditioning Equipment
Name Library type Heating Percent Load Coaling Percent Load Hot Water Percent Load
COOLING CA13 NA036 0% 100% o%
HEATING 912SA4808OS 17
100% 0% o%
Water Heating RG2PV75H'N
0% 0% 100%
Equipment Type: 9125A4808OS17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 78
Use default EAE No
EAE [kWh] 977
Equipment Type: CA13NA0361,im
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 34.2
Equipment Type: RG21DV751-1-N
Fuel Type Natural Gas
Distribution Type Hydronic Delivery
Hot Water Efficiency 0.7 Energy Factor
Tank Capacity (gal.) 75
Hot Water Capacity [kBtulh] 76
Recovery Efficiency 0.82
Building Summary
Property
Organization
2751 SILVER OAKS DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
5574
Community: CAMDEN WALK 67
Builder
Supply Duct R Value
RICHARD CARRIGER CO.
CWD67 [AS DESIGNED]
20
CAMDEN WALK 67
1504.98
Distribution System
Distribution Type
Forced Air
Heating Equipment
HEATING
Cooling Equipment
COOLING
Sq. Feet Served
5574
# Return Grilles
4
Supply Duct R Value
30
Return Duct R Value
20
Supply Duct Area [sq. ft.]
1504.98
Return Duct Area [sq. ft]
1114.8
Duct Leakage to Outdoors (CFM25)
220
Total Leakage
440
Total Leakage Dud Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
100
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
❑
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
2751 SILVEROAKS DR
CARMEL, IN 46032
Madel: CUSTOM
Community: CAMDEN WALK 67
CWD67 [AS DESIGNED]
CAMDEN WALK 67
Organization
TSI Energy Solutions
Devin Sielschott
Builder
RICHARD CARRIGER CO.
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
50
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
26
Drain Water Heat Recovery?
No
Clothes Dryer
Fuel Type Electric
Cef 2.617
Field Utilization Timer Controls
asher VWV
Label Energy Rating
704 kWh/Year
Electric Rate
$0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.58frherm
Capacity
2.874
Imet
0.33053
Appliances and Controls
M
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Electric
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
709 kVVh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions