Loading...
HomeMy WebLinkAboutCAMDEN WALK 67 - CW067 (AS DESIGNED)IECC 2009 Performance Compliance Property 2751 SILVER OAKS DR CARMEL, IN 46032 Model: CUSTOM Community: CAMDEN WALK 67 CW067 (AS DESIGNED) CAMDEN WALK 67 Organization TSI Energy Solutions Devin Sielschott Builder RICHARD CARRIGER Co. Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance 51,714 5249 $181 $2,945 $1,355 $0 $3,500 Requirements C4405.3 Performance-based compliance passes by D.0% R402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation C-M, Energy Solutions As Designed $1,754 $208 $182 $2,144 $1,355 $0 $3,499 Air sealing is 5.0D ACH at 50 Pa. It must not exceed 7.013ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 0%. Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 615119 at 8:34 AM Ekotrope RATER - Version 2.2.4.2188 IECC 2009 Performance compliance results calculated using Eketrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all1iabitityfor the information shown on this report. 2751 SILVER OAKS DR CARMEL, IN 46032 Builder: RICHARD CARRIGER CO. Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-11 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.29, SHGC: 0.33 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 220.0 CFM @ 25Pa Total Duct Leakage 440.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric - 13 SEER Water Heating Water Heater • Natural Gas • 0.7 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 615119 at 8:34 AM Ekotrope RATER - Version 2.2.4.2188 2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 2751 SILVER OAKS DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: CAMDEN WALK 67 Builder RICHARD CARRIGER CW067 (AS DESIGNED) Co. CAMDEN WALK 67 General Building Information Conditioned Area (sq ft) 5,574 Conditioned Volume (cubic ft) 55,471 Insulated Shell Area (sq ft) 10,641 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (2,787 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall El Name: CONDIAMB (Exterior Perimeter [ft]: 80, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ] Name: CONDIAMB UN FIN (Exterior Perimeter [ft]: 139, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ]l Name: CONDIGARAGE UNFIN (Exterior Perimeter [ft]: 19, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wail to bottom of insulation: 4 Above Grade Wall ] Name: CCNDIAMB (2,301 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Cade Inspection Checklist Property Organization 2751 SILVER OAKS DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: CAMDEN WALK 67 Builder RICHARD CARRIGER CW067 (AS DESIGNED) CO. CAMDEN WALK 67 Name: COND/GAR (190 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIATTIC (177 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist 1� Name: CON DIAMBRIM (219 s.f.) 1--1 R: 15.414 El Name: CONDIGARAGE RIM (19 s.f.) R: 15.414 Roof LA Name: MAIN (2,787 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door 1� Name: FRONT (48 s.f.) 1--1 U: 0.476 El Name: GARAGE (24 s.f.) U: 0.182 Glazing Inspection Status Results are projected 11 Name: FRONT (64 s.f.), U: 0.290, SHGC: 0.33, Orientation: SOUTH 11 Name: BACK (209 s.f.), U: 0.290, SHGC: 0.33, Orientation: NORTH Name: GO (24 s.f.), U: 0.290, SHGC: 0.33, Orientation: NORTH C-M, Energy Solutions 2 Energy Code Inspection Checklist TSI Energy Solutions Property Organization Inspection Status 2751 SILVER OAKS DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: CAMDEN WALK 67 Builder RICHARD CARRIGER CW067 (AS DESIGNED) Co. CAMDEN WALK 67 Name: LEFT (11 s.f.), U: 0.290, SHGC: 0.33, Orientation: WEST E] Name: RIGHT (75 s.f.), U: 0.290, SHGC: 0.33, Orientation: EAST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 1I HEATING • Natural Gas • 100% Heating Load @ 92.1 AFUE El COOLING • Electric • 100°1% Cooling Load @ 13 SEER [] Water Heating • Natural Gas • 100% Hot Water Load @ 0.7 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 4,623 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 220.0 CFM @ 25Pa 3 Total Duct Leakage is specified in Ekotrope at 440.0 CFM @ 25Pa Energy Code Inspection Checklist Property Organization 2751 SILVER OAKS DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: CAMDEN WALK 67 Builder RICHARD CARRIGER CW067 (AS DESIGNED) CO. CAMDEN WALK 67 Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 3 CFM251 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status C-MEnergy Solutions 2751 SILVER OAKS DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: CAMDEN WALK 67 Builder RICHARD CARRIGER CO. CWD67 [AS DESIGNED] CAMDEN WALK 67 General Building Information Number Of Bedrooms 4 Number Of Floors 1 Conditioned Floor Area [sq. ft.] 5,574 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 55,471 Total Units in Building 1 Residence Type Single family detached Floor Number Model CUSTOM Community CAMDEN WALK 67 Climate Zone 5A Foundation Wall Name Library type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4ft 1 8 80 Exposed Exterior Conditioned Space CONDIAMB UNFIN R-11 Draped, 4ft 1 8 139 Exposed Exterior Conditioned Space CONDIGARAGE R-11 Draped, 4ft 1 9 19 Exposed Exterior Conditioned Space UNFIN Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R -value Cavity R -value Effective Insulation R - Continuous Insulation Continuous Insulation value Top Bottom R-11 Draped; 4ft 0 4 No NIA NIA 11.00 Slab Name Library type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 238 Below Grade 0 ❑ 2,787.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completelyx Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [R] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame I Other No 0 0 ❑ No 0.00 1 Building Summary Property 2751 SILVEROAKS DR CARMEL, IN 46032 Model: CUSTOM Community: CAMDEN WALK 67 CWD67 [AS DESIGNED] CAMDEN WALK 67 Framed Floor Organization TSI Energy Solutions Devin Sielschott Builder RICHARD CARRIGER CO. Framed Floor Library List None Present Rim Joist CONDIAMB RIM CONDIGARAGE RIM uorary rype G1 R-19, OSB C-M Energy Solutions Inspection Status Results are projected 219.0 sq. R. Exposed Exterior G1 R-19, OSB 19.0 sq. R. Unconditioned, attached garage Rim Joist Library List Name Effective Insulation R-valLie G1 R-19. OSB 15.414 Name CONDIAMB Library Type G1 R-15 BATT, OSB Surface Color Medium Surface Area 2,301.0 sq. ft. Location Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 177.0 sq. 11 Attic CONDIGAR G1 R-15 Gar Walls Medium 1900.sq. 11 Unconditioned. attached garage Building Summary Property Organization Inspection Status C-MEnergy Solutions 2751 SILVER OAKS DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: CAMDEN WALK 67 Builder RICHARD CARRIGER CO. CWD67 [AS DESIGNED] CAMDEN WALK 67 ll Library List Name Effective R -value ra G1 R-15 BATT. OSB 3 13.423 G1 R-15 Gar Walls 11.972 Glazing Name Library 'Type Wall Assignment Foundation Wall Overhang Assignment Depth Overhang Ft To Overhan Tap Ft To Bottom Orientation Surface Area BACK U-29, SHGC-.33 CONDIAMB 0 0 0 North 209.0 sq. ft. FRONT U-29, SHGC-.33 CONDIAMB 0 0 0 South 64.0 sq. ft. GD U-29, SHGC-.33 CONDIAMB 0 0 0 North 24.0 sq. ft. LEFT U-29, SHGC-.33 CONDIAMB 0 0 0 West 11.0 sq. ft. RIGHT U-29, SHGC-.33 CONDIAMB 0 0 0 East 75.0 sq. ft. Glazing Library List Name Shgc U -factor U-29, SHGG.33 0.33 0290 Skylight Skylight Library List None Present 3 Building Summary Property Organization Inspection Status C-MEnergy Solutions 2751 SILVER OAKS DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: CAMDEN WALK 67 Builder RICHARD CARRIGER CO. CWD67 [AS DESIGNED] CAMDEN WALK 67 Opaque Door Name Library type Wal I Assi g n ment Fou ndatian Wall Emittance Solar Surface Color Surface Area Location Assignment Ab so rp to n ce FRONT Wood Door CONDlAMB 0.9 0.75 Medium 48.0 sq. 11 Exposed Exterior GARAGE Fiberglass/Steel CONDlGAR 0.9 0.75 Medium 24.0 sq. 11 Exposed Exterior Door ■ Opaque Door Library List Name FiberglasslSteel Door Wood Door 0.182 0.476 Raaf Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof P.f.] Tiles I•;IAIN R-38 Blown, GR1 2,787 No Raaf Insulation Library List Name Has R-38 Blown, GR1 No Whole House Infiltration Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested 38268 Shelter Class 4 Medium 2.787.0 sq. ft. Attic 4 Building Summary Property 2751 SILVEROAKS DR CARMEL, IN 46032 Model: CUSTOM Community: CAMDEN WALK 67 CWD67 [AS DESIGNED] CAMDEN WALK 67 Mechanical Ventilation Lighting Interior Fluore Lig Organization TSI Energy Solutions Devin Sielschott Builder RICHARD CARRIGER CO - Inspection Status Results are projected C-M, Energy Solutions 0 Onsite Generation 0 Onsite Generation Library List Solar Generation Solar Generation Library List None Present None Present None Present 0 0 0 5 Building Summary Property Organization Inspection Status C-MEnergy Solutions 2751 SILVER OAKS DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Madel: CUSTOM Community: CAMDEN WALK 67 Builder RICHARD CARRIGER CO. CWD67 [AS DESIGNED] CAMDEN WALK 67 Conditioning Equipment Name Library type Heating Percent Load Coaling Percent Load Hot Water Percent Load COOLING CA13 NA036 0% 100% o% HEATING 912SA4808OS 17 100% 0% o% Water Heating RG2PV75H'N 0% 0% 100% Equipment Type: 9125A4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 977 Equipment Type: CA13NA0361,im Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 34.2 Equipment Type: RG21DV751-1-N Fuel Type Natural Gas Distribution Type Hydronic Delivery Hot Water Efficiency 0.7 Energy Factor Tank Capacity (gal.) 75 Hot Water Capacity [kBtulh] 76 Recovery Efficiency 0.82 Building Summary Property Organization 2751 SILVER OAKS DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM 5574 Community: CAMDEN WALK 67 Builder Supply Duct R Value RICHARD CARRIGER CO. CWD67 [AS DESIGNED] 20 CAMDEN WALK 67 1504.98 Distribution System Distribution Type Forced Air Heating Equipment HEATING Cooling Equipment COOLING Sq. Feet Served 5574 # Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 20 Supply Duct Area [sq. ft.] 1504.98 Return Duct Area [sq. ft] 1114.8 Duct Leakage to Outdoors (CFM25) 220 Total Leakage 440 Total Leakage Dud Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 100 Percent Return Area 50 Duct 2 Duct Location Attic (well vented, under insulation) Percent Supply Area ❑ Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 2751 SILVEROAKS DR CARMEL, IN 46032 Madel: CUSTOM Community: CAMDEN WALK 67 CWD67 [AS DESIGNED] CAMDEN WALK 67 Organization TSI Energy Solutions Devin Sielschott Builder RICHARD CARRIGER CO. Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 50 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 26 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.617 Field Utilization Timer Controls asher VWV Label Energy Rating 704 kWh/Year Electric Rate $0.081kWh Annual Gas Cost $23.00 Gas Rate $0.58frherm Capacity 2.874 Imet 0.33053 Appliances and Controls M Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Electric Convection Oven? No Induction Range? No Refrigerator Consumption 709 kVVh/Year Inspection Status Results are projected C-M, Energy Solutions