23GO - Trusses
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). June 17,2019 Liu, Xuegang Pages or sheets covered by this seal: I37458387 thru I37458497 My license renewal date for the state of Indiana is July 31, 2020. B19901802 Wedgewood 23 Gray Oaks IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss CG01 Truss Type Diagonal Hip Girder Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458387 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-ZgOjJKNtCiQxTninmXlw?aeOC_yaIfkX2iU471z5PzT Scale = 1:24.4 1 2 3 5 4 6 7 8 9 2x4 4x6 2x4 4x6 4-5-7 4-5-7 -2-2-13 2-2-13 4-5-7 4-5-7 1-5-94-3-43-11-120-3-84-3-47.57 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.26 0.10 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 -0.00 0.01 (loc) 4-5 4-5 4 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=357/0-3-8, 4=102/0-1-8 Max Horz 5=129(LC 4) Max Uplift 5=-132(LC 5), 4=-105(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-318/126 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 132 lb uplift at joint 5 and 105 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 15 lb down and 1 lb up at -2-2-13, and 39 lb down and 82 lb up at 2-1-13, and 59 lb down and 73 lb up at 2-11-2 on top chord, and 4 lb down and 60 lb up at 2-1-13, and 3 lb down at 2-11-2 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 1=-15(F) 6=27(F) 8=7(F) 9=-2(B) June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss CG02 Truss Type Diagonal Hip Girder Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458388 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-1sy5WgNVz?Yo5xH_KFG9YnAY?OGD15dgHMDegTz5PzS Scale = 1:30.1 1 2 3 5 4 6 7 8 9 10 11 2x4 4x6 2x4 4x6 5-11-10 5-11-10 -2-2-13 2-2-13 5-11-10 5-11-10 1-5-95-2-114-11-30-3-85-2-117.57 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.32 0.20 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.04 -0.00 0.01 (loc) 4-5 4-5 4 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 38 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=455/0-3-8, 4=232/0-1-8 Max Horz 5=192(LC 5) Max Uplift 5=-95(LC 5), 4=-141(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-400/106 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 95 lb uplift at joint 5 and 141 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 35 lb down and 3 lb up at -2-2-13, 71 lb down and 29 lb up at 1-1-14, and 54 lb down and 65 lb up at 3-7-15, and 64 lb down and 99 lb up at 4-10-4 on top chord, and 3 lb down and 11 lb up at 1-1-14, and 5 lb down and 43 lb up at 3-7-15, and 34 lb down at 4-10-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 1=-35(F) 8=-40(F) 9=4(F) 10=7(B) 11=-26(F) June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss CG03 Truss Type Diagonal Hip Girder Qty 2 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458389 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-1sy5WgNVz?Yo5xH_KFG9YnAY?OG515OgHMDegTz5PzS Scale = 1:36.7 1 2 3 5 4 6 7 8 9 10 11 2x4 4x6 2x4 4x6 6-1-6 6-1-6 -2-2-13 2-2-13 6-1-6 6-1-6 2-6-116-4-156-1-70-3-86-4-157.57 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.32 0.21 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.04 -0.00 0.05 (loc) 4-5 4-5 4 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 41 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)5=451/0-3-8, 4=221/0-1-8 Max Horz 5=212(LC 12) Max Uplift 5=-185(LC 5), 4=-332(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-389/65 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 185 lb uplift at joint 5 and 332 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 35 lb down and 3 lb up at -2-2-13, 75 lb down and 18 lb up at 1-3-4, and 37 lb down and 89 lb up at 3-9-12, and 67 lb down and 98 lb up at 4-11-10 on top chord, and 5 lb down and 99 lb up at 1-3-4, and 10 lb down and 175 lb up at 3-9-12, and 40 lb down and 50 lb up at 4-11-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 1=-35(F) 7=38(B) 8=-49(F) 10=3(B) 11=-20(F) June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss GE01 Truss Type Common Supported Gable Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458390 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-V2WUk0O7kJgfj5rAuynO4?jlkoe7mY7qV0zBCwz5PzR Scale = 1:58.8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 2x4 3x4 4x6 3x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 21-9-0 21-9-0 10-10-8 10-10-8 21-9-0 10-10-8 22-11-8 1-2-8 0-10-149-0-120-10-149.00 12 Plate Offsets (X,Y)-- [31:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.20 0.09 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 0.00 0.01 (loc) 18 18 19 18 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 130 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 9-27: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 9-27 REACTIONS.All bearings 21-9-0. (lb) - Max Horz 36=-226(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 19, 28, 29, 30, 32, 33, 34, 26, 25, 24, 23, 22, 21, 20 except 36=-110(LC 4), 35=-108(LC 5) Max Grav All reactions 250 lb or less at joint(s) 36, 19, 27, 28, 29, 30, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 28, 29, 30, 32, 33, 34, 26, 25, 24, 23, 22, 21, 20 except (jt=lb) 36=110, 35=108. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss GE02 Truss Type GABLE Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458391 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-zE3sxMPlVdoWKFQMSgIddCGwjCt9VuvzkgikkMz5PzQ Scale = 1:66.4 1 2 3 4 5 10 9 8 7 6 3x4 4x6 4x6 4x6 3x4 5x6 5x6 3x8 3x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3-0-13 3-0-13 8-0-0 4-11-3 12-11-3 4-11-3 16-0-0 3-0-13 3-0-13 3-0-13 8-0-0 4-11-3 12-11-3 4-11-3 16-0-0 3-0-13 1-2-610-6-61-2-63-2-1414.00 12 14.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.25 0.49 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.09 -0.23 0.48 0.08 (loc) 7-8 7-8 6 8-9 l/defl >999 >810 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 92 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-10,5-6: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-10-6 oc bracing. REACTIONS.(lb/size)10=628/0-3-8, 6=628/0-3-8 Max Horz 10=-260(LC 4) Max Uplift 10=-30(LC 7), 6=-30(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-643/137, 1-2=-2034/420, 2-3=-688/79, 3-4=-688/98, 4-5=-2034/25, 5-6=-643/54 BOT CHORD 9-10=-385/420, 8-9=-446/1203, 7-8=0/1203 WEBS 3-8=-26/580, 4-8=-852/140, 4-7=0/1041, 5-7=0/1541, 2-8=-852/394, 2-9=-407/1041, 1-9=-288/1541 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 10, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss GE03 Truss Type Common Supported Gable Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458392 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-vdBcM2Q01E2EaYalZ5K5idLGA?dIzrDGB_BrpFz5PzO Scale = 1:87.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 3x6 3x6 3x4 4x6 3x4 3x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-6-8 19-6-8 -1-2-8 1-2-8 9-9-4 9-9-4 19-6-8 9-9-4 20-9-0 1-2-8 1-5-912-10-51-5-914.00 12 Plate Offsets (X,Y)-- [10:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.25 0.25 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 0.01 0.01 (loc) 19 19 20 19 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 167 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 10-27,9-28,8-29,11-26,12-25: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 10-27, 9-28, 8-29, 11-26, 12-25 REACTIONS.All bearings 19-6-8. (lb) - Max Horz 35=-325(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 28, 29, 30, 31, 33, 26, 25, 24, 23, 22 except 35=-294(LC 4), 20=-259(LC 5), 34=-304(LC 5), 21=-282(LC 4) Max Grav All reactions 250 lb or less at joint(s) 28, 29, 30, 31, 33, 26, 25, 24, 23, 22, 21 except 35=367(LC 5), 20=332(LC 4), 27=463(LC 7), 34=258(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-291/268, 7-8=-15/278, 8-9=-16/369, 9-10=-20/383, 10-11=-20/383, 11-12=-16/369, 12-13=-15/278, 17-18=-262/239 WEBS 10-27=-507/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 29, 30, 31, 33, 26, 25, 24, 23, 22 except (jt=lb) 35=294, 20=259, 34=304, 21=282. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss GE04 Truss Type Common Supported Gable Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458393 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Opl_ZOReoYA5Bi9x7orKFruRVP?7iL4PQexOLhz5PzN Scale = 1:59.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 2x4 3x4 4x6 3x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 21-11-0 21-11-0 -1-2-8 1-2-8 10-11-8 10-11-8 21-11-0 10-11-8 23-1-8 1-2-8 0-10-149-1-80-10-149.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.09 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.01 0.00 0.01 (loc) 19 19 20 19 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 133 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 10-28: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 10-28 REACTIONS.All bearings 21-11-0. (lb) - Max Horz 37=-215(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 20, 29, 30, 31, 33, 34, 35, 27, 26, 25, 24, 23, 22, 21 except 37=-113(LC 4), 36=-108(LC 5) Max Grav All reactions 250 lb or less at joint(s) 37, 20, 28, 29, 30, 31, 33, 34, 35, 36, 27, 26, 25, 24, 23, 22, 21 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 29, 30, 31, 33, 34, 35, 27, 26, 25, 24, 23, 22, 21 except (jt=lb) 37=113, 36=108. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss GE05 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458394 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Opl_ZOReoYA5Bi9x7orKFruPLP0liM9PQexOLhz5PzN Scale = 1:29.9 1 2 3 4 7 6 5 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4-7-2 4-7-2 0-0-45-4-514.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.35 0.05 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 4-7-2. (lb) - Max Horz 1=145(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6, 7 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 7. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J01 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458395 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:45:59 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-s0JNnkSGZrIypsk7hVNZn2QabpKGRpFZfIgyt7z5PzM Scale = 1:17.6 1 2 5 3 43x4 3x6 1-2-7 1-2-7 -1-2-8 1-2-8 1-2-7 1-2-7 1-5-92-10-62-3-42-10-614.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.38 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 -0.01 0.00 (loc) 5 5 3 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-2-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=176/0-3-8, 3=-11/Mechanical, 4=0/Mechanical Max Horz 5=126(LC 6) Max Uplift 3=-33(LC 7), 4=-56(LC 6) Max Grav 5=176(LC 1), 3=17(LC 4), 4=17(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J02 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458396 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-KCtl_4TuK9QpR0JKEDuoKGznpDhMAGViuyQVPZz5PzL Scale = 1:20.1 1 2 5 3 4 2x4 3x4 3-4-3 3-4-3 -1-2-8 1-2-8 3-4-3 3-4-3 0-10-143-5-02-11-83-5-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.22 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 -0.01 0.01 (loc) 4-5 4-5 3 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=224/0-3-8, 3=77/Mechanical, 4=31/Mechanical Max Horz 5=127(LC 6) Max Uplift 5=-15(LC 6), 3=-52(LC 6) Max Grav 5=224(LC 1), 3=77(LC 1), 4=59(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J03 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458397 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-KCtl_4TuK9QpR0JKEDuoKGznFDiDAGViuyQVPZz5PzL Scale = 1:14.5 1 2 5 3 42x4 3x4 1-10-4 1-10-4 -1-2-8 1-2-8 1-10-4 1-10-4 0-10-142-3-91-10-12-3-99.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.20 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=182/0-3-8, 3=26/Mechanical, 4=10/Mechanical Max Horz 5=94(LC 6) Max Uplift 5=-27(LC 6), 3=-24(LC 6), 4=-3(LC 6) Max Grav 5=182(LC 1), 3=26(LC 1), 4=30(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J04 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458398 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-KCtl_4TuK9QpR0JKEDuoKGzknDf9AGViuyQVPZz5PzL Scale = 1:26.1 1 2 5 3 4 3x4 2x4 4-11-10 4-11-10 -1-2-8 1-2-8 4-11-10 4-11-10 0-10-144-7-94-2-14-7-99.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.42 0.24 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.07 0.03 0.03 (loc) 4-5 4-5 3 4-5 l/defl >999 >828 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=283/0-3-8, 3=125/Mechanical, 4=54/Mechanical Max Horz 5=165(LC 6) Max Uplift 5=-5(LC 6), 3=-79(LC 6) Max Grav 5=283(LC 1), 3=125(LC 1), 4=90(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J05 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458399 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:01 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-oOR7CPUW5TZf2AuWowP1sTWuyd?2vjlr6c93y0z5PzK Scale = 1:22.4 1 2 5 3 4 3x4 3x6 2-0-4 2-0-4 -1-2-8 1-2-8 2-0-4 2-0-4 1-5-93-9-133-2-113-9-1314.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.45 0.20 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 -0.00 -0.02 0.00 (loc) 5 5 3 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=245/0-3-8, 3=11/Mechanical, 4=5/Mechanical Max Horz 5=153(LC 6) Max Uplift 3=-61(LC 6), 4=-36(LC 6) Max Grav 5=245(LC 1), 3=18(LC 4), 4=27(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 35 lb down and 7 lb up at -1-2-8 on top chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 1=-35(F) June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J06 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458400 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Gb?VPlU8smhWgJTiMewGPh28O0MieAB?LFvcUSz5PzJ Scale = 1:20.6 1 2 6 5 3 4 2x4 3x6 2x4 1-4-0 1-4-0 1-11-7 0-7-7 -1-2-8 1-2-8 1-11-7 1-11-7 2-0-03-5-93-0-13-5-99.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.15 0.11 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.01 0.00 (loc) 6 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=184/0-3-8, 3=23/Mechanical, 4=18/Mechanical Max Horz 6=113(LC 6) Max Uplift 3=-12(LC 7), 4=-88(LC 6) Max Grav 6=184(LC 1), 3=23(LC 1), 4=36(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J07 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458401 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Gb?VPlU8smhWgJTiMewGPh24i0HVe9g?LFvcUSz5PzJ Scale = 1:32.8 1 2 6 5 3 4 2x4 3x6 2x4 1-4-0 1-4-0 5-0-12 3-8-12 -1-2-8 1-2-8 5-0-12 5-0-12 2-0-05-9-95-4-15-9-99.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.39 0.44 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.08 -0.11 0.09 (loc) 4-5 4-5 3 4-5 l/defl >999 >699 n/a >615 L/d 360 240 n/a 240 PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=287/0-3-8, 3=134/Mechanical, 4=49/Mechanical Max Horz 6=184(LC 6) Max Uplift 3=-78(LC 6), 4=-33(LC 6) Max Grav 6=287(LC 1), 3=134(LC 1), 4=97(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-18/346 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J08 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458402 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-knYtd5Vnd4pNIT2vwLRVyubFSQdkNcw8ave90uz5PzI Scale = 1:32.8 1 2 6 5 3 4 2x4 3x6 2x4 1-4-0 1-4-0 5-0-12 3-8-12 -1-2-8 1-2-8 5-0-12 5-0-12 2-0-05-9-95-4-15-9-99.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.39 0.44 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.08 -0.11 0.09 (loc) 4-5 4-5 3 4-5 l/defl >999 >699 n/a >615 L/d 360 240 n/a 240 PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=287/0-3-8, 3=134/Mechanical, 4=49/Mechanical Max Horz 6=184(LC 6) Max Uplift 3=-78(LC 6), 4=-33(LC 6) Max Grav 6=287(LC 1), 3=134(LC 1), 4=97(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-18/346 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J09 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458403 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-knYtd5Vnd4pNIT2vwLRVyubJ8QixNdR8ave90uz5PzI Scale = 1:20.6 1 2 6 5 3 4 2x4 3x6 2x4 1-4-0 1-4-0 1-11-7 0-7-7 -1-2-8 1-2-8 1-11-7 1-11-7 2-0-03-5-93-0-13-5-99.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.15 0.11 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.01 0.00 (loc) 6 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=184/0-3-8, 3=23/Mechanical, 4=18/Mechanical Max Horz 6=113(LC 6) Max Uplift 3=-12(LC 7), 4=-88(LC 6) Max Grav 6=184(LC 1), 3=23(LC 1), 4=36(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J10 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458404 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Cz6GqRWPOOxEvdc5T3ykU68TAq?s63zIoZOjZLz5PzH Scale = 1:28.6 1 2 6 5 3 4 2x4 4x6 2x4 1-4-0 1-4-0 2-1-3 0-9-3 -1-2-8 1-2-8 2-1-3 2-1-3 2-6-115-0-14-1-145-0-114.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.14 0.26 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.02 0.01 (loc) 6 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)6=246/0-3-8, 3=6/Mechanical, 4=16/Mechanical Max Horz 6=170(LC 6) Max Uplift 3=-25(LC 7), 4=-165(LC 6) Max Grav 6=246(LC 1), 3=21(LC 4), 4=36(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-259/0 WEBS 2-5=-16/397 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 4=165. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 35 lb down and 7 lb up at -1-2-8 on top chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-6=-20 Concentrated Loads (lb) Vert: 1=-35(F) June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss J11 Truss Type Jack-Open Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458405 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Cz6GqRWPOOxEvdc5T3ykU68SDq?s63_IoZOjZLz5PzH Scale = 1:28.6 1 2 6 5 3 4 2x4 4x6 2x4 1-4-0 1-4-0 2-1-3 0-9-3 -1-2-8 1-2-8 2-1-3 2-1-3 2-6-115-0-14-1-145-0-114.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.20 0.26 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.02 0.01 (loc) 6 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)6=306/0-3-8, 3=-18/Mechanical, 4=15/Mechanical Max Horz 6=170(LC 6) Max Uplift 3=-26(LC 2), 4=-165(LC 6) Max Grav 6=306(LC 1), 3=15(LC 4), 4=36(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-289/0 WEBS 2-5=-16/397 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 4=165. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 70 lb down and 13 lb up at -1-2-8 on top chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-6=-20 Concentrated Loads (lb) Vert: 1=-70(F) June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M01 Truss Type MONOPITCH Qty 18 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458406 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-gAge1nX18h35XnBH1mTz1JgZhELRrTUR1D7G5nz5PzG Scale = 1:59.7 1 2 3 4 6 5 2x4 3x4 3x4 3x8 5x6 7-7-8 7-7-8 -1-2-8 1-2-8 3-6-0 3-6-0 7-7-8 4-1-8 1-5-910-4-510-0-130-3-810-4-514.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.47 0.30 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.11 -0.28 -0.00 0.00 (loc) 5-6 5-6 5 5-6 l/defl >795 >320 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 46 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF No.2, 2-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS.(lb/size)6=382/0-3-8, 5=286/0-1-8 Max Horz 6=352(LC 6) Max Uplift 5=-227(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-5=-148/255, 3-6=-319/78 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=227. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M02 Truss Type Monopitch Qty 2 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458407 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-gAge1nX18h35XnBH1mTz1Jgc?ENQrXkR1D7G5nz5PzG Scale = 1:24.8 1 2 3 5 4 2x4 3x4 3x4 2x4 4-7-4 4-7-4 -1-2-8 1-2-8 4-7-4 4-7-4 0-10-144-4-54-0-130-3-84-4-59.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.26 0.17 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.04 0.00 0.01 (loc) 4-5 4-5 4 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=267/0-3-8, 4=160/0-1-8 Max Horz 5=154(LC 6) Max Uplift 5=-8(LC 6), 4=-64(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M03 Truss Type Monopitch Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458408 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-9ME0F7Xfv?By9xmTbT?CZXDk2ecBaxxbGttqdDz5PzF Scale = 1:51.2 1 2 3 5 467 2x4 2x4 3x4 3x4 3x6 7-10-8 7-10-8 3-6-0 3-6-0 7-10-8 4-4-8 3-1-49-0-29.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.50 0.59 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.14 -0.36 -0.00 -0.00 (loc) 4-5 4-5 4 4-5 l/defl >631 >253 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 40 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-4 REACTIONS.(lb/size)4=343/0-3-8, 5=350/0-3-8 Max Horz 5=177(LC 6) Max Uplift 4=-159(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=159. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M04 Truss Type MONOPITCH Qty 5 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458409 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-dYoOSTYHgJJpm5Lg9BWR6klqE1_WJQjkVXcN9fz5PzE Scale = 1:51.1 1 2 4 3 5x6 3x4 3x4 3x4 7-7-0 7-7-0 7-7-0 7-7-0 3-3-149-0-29.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.79 0.45 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.13 -0.31 -0.00 -0.01 (loc) 3-4 3-4 3 3-4 l/defl >699 >288 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-3 REACTIONS.(lb/size)3=293/0-3-8, 4=293/Mechanical Max Horz 4=170(LC 6) Max Uplift 3=-161(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=161. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M05 Truss Type MONOPITCH Qty 3 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458410 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-dYoOSTYHgJJpm5Lg9BWR6klx_121JRikVXcN9fz5PzE Scale = 1:37.9 1 2 4 3 3x6 2x4 3x4 2x4 4-10-0 4-10-0 4-10-0 4-10-0 3-3-146-11-69.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.36 0.23 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.07 -0.00 0.00 (loc) 3-4 3-4 3 4 l/defl >999 >831 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=183/0-3-8, 4=183/Mechanical Max Horz 4=106(LC 6) Max Uplift 3=-127(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=127. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M06 Truss Type Monopitch Qty 8 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458411 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-5lMmgpZvRcRgOEwsiu1gfyI39RLf2rLtjBMwi6z5PzD Scale = 1:59.7 1 2 3 5 4 2x4 2x4 3x4 3x8 5x6 7-7-8 7-7-8 3-6-0 3-6-0 7-7-8 4-1-8 1-5-910-4-510-0-130-3-810-4-514.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.52 0.33 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.11 -0.27 -0.00 0.00 (loc) 4-5 4-5 4 4-5 l/defl >795 >320 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 44 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-4: 2x4 SPF No.2, 1-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-4 REACTIONS.(lb/size)5=293/0-3-8, 4=293/0-1-8 Max Horz 5=264(LC 6) Max Uplift 4=-225(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-160/253 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=225. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M07 Truss Type MONOPITCH Qty 5 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458412 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-5lMmgpZvRcRgOEwsiu1gfyI6uRMg2uUtjBMwi6z5PzD Scale = 1:30.7 1 2 3 5 4 3x4 3x4 3x4 3x6 -1-2-8 1-2-8 5-10-8 5-10-8 0-10-145-3-125-0-40-3-85-3-129.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.35 0.27 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.11 0.00 0.03 (loc) 4-5 4-5 4 4-5 l/defl >999 >623 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=314/0-3-8, 4=213/0-1-8 Max Horz 5=184(LC 6) Max Uplift 4=-81(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-270/63 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M08 Truss Type MONOPITCH Qty 6 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458413 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:09 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Zxw9t9aXCwZX0OV2GcYvB9rHjri0nDp1yr5UEYz5PzC Scale = 1:67.7 1 2 3 6 5 4 7 8 9 3x6 5x8 3x4 2x4 2x4 3x8 3x4 3x4 3x4 5-11-8 5-11-8 11-11-0 5-11-8 5-11-8 5-11-8 11-11-0 5-11-8 3-6-612-5-101-1-212-5-109.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.34 0.26 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.10 -0.02 0.01 (loc) 4-5 4-5 8 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 83 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-5,1-5: 2x3 SPF No.2, 1-6: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-5, 3-8 REACTIONS.(lb/size)6=491/Mechanical, 8=561/0-3-8 Max Horz 6=262(LC 6) Max Uplift 8=-209(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-385/0, 2-3=-414/102, 1-6=-448/0 BOT CHORD 5-6=-270/31 WEBS 2-5=-397/242, 3-5=-268/509, 3-8=-561/209 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=209. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M09 Truss Type Monopitch Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458414 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:10 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-17TX5UbAzEhOdY4FqJ38kNNTnF5KWkoABVr1m_z5PzB Scale = 1:24.7 1 2 4 3 5 62x4 3x8 2x4 3x4 3x4 4-7-0 4-7-0 4-7-0 4-7-0 0-10-144-4-21-7-24-4-29.00 12 Plate Offsets (X,Y)-- [2:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.26 0.13 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 -0.01 0.01 (loc) 3-4 3-4 6 3-4 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=172/0-3-8, 6=152/0-3-0 Max Horz 4=104(LC 6) Max Uplift 6=-62(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M10 Truss Type Monopitch Qty 6 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458415 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-VJ1vIqbokXpFFifRO1aNGawgifS?FEyKQ9abIRz5PzA Scale = 1:28.0 1 2 3 5 4 2x4 2x4 3x6 3x4 2-0-0 2-0-0 -1-2-8 1-2-8 2-0-0 2-0-0 2-6-114-10-114-7-30-3-84-10-1114.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.18 0.03 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 5 4-5 4 5 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=182/0-3-8, 4=36/0-1-8 Max Horz 5=166(LC 6) Max Uplift 4=-198(LC 6) Max Grav 5=182(LC 1), 4=46(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-14/329 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=198. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M11 Truss Type Monopitch Qty 2 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458416 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-zWbHWAcQVrx6tsEdxk5cpoTlS2ih_iaTepK8rtz5Pz9 Scale = 1:37.6 1 2 3 5 4 2x4 2x4 3x6 3x4 -1-2-8 1-2-8 6-0-0 6-0-0 2-0-06-6-06-2-80-3-86-6-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.57 0.39 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.16 -0.00 0.00 (loc) 4-5 4-5 4 5 l/defl >999 >430 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=319/0-3-8, 4=219/0-1-8 Max Horz 5=204(LC 6) Max Uplift 4=-120(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-262/0 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=120. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss M12 Truss Type MONOPITCH Qty 5 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458417 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:13 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Ri9fjWd2G93zU0oqVSdrL???CS3Uj8edtT3hNJz5Pz8 Scale = 1:38.0 1 2 3 5 4 2x4 2x4 4x6 3x4 -2-6-8 2-6-8 6-0-0 6-0-0 2-0-06-6-06-2-80-3-86-6-09.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.24 0.35 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.16 -0.00 0.00 (loc) 4-5 4-5 4 5 l/defl >999 >430 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 38 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=428/0-3-8, 4=190/0-1-8 Max Horz 5=245(LC 6) Max Uplift 5=-21(LC 6), 4=-102(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-370/69 BOT CHORD 4-5=-269/0 WEBS 2-4=-0/281 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 4=102. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458418 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:13 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Ri9fjWd2G93zU0oqVSdrL??snS0nj6?dtT3hNJz5Pz8 Scale = 1:59.3 1 2 3 5 4678 3x4 5x6 6x16 7-7-8 7-7-8 -1-2-8 1-2-8 7-7-8 7-7-8 1-5-910-4-514.00 12 Plate Offsets (X,Y)-- [5:0-0-0,0-1-12], [5:1-2-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.78 0.53 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.07 -0.18 0.00 0.05 (loc) 4-5 4-5 4 4-5 l/defl >999 >491 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 115 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 2-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-4 REACTIONS.(lb/size)4=1815/Mechanical, 5=1700/0-3-8 Max Horz 5=350(LC 5) Max Uplift 4=-290(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BOT CHORD 4-5=-559/788 WEBS 2-4=-775/554 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=290. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 933 lb down and 45 lb up at 2-0-12, and 949 lb down and 42 lb up at 4-0-12, and 965 lb down and 46 lb up at 6-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Continued on page 2 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458418 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:13 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Ri9fjWd2G93zU0oqVSdrL??snS0nj6?dtT3hNJz5Pz8 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 6=-933(F) 7=-949(F) 8=-965(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB01 Truss Type Piggyback Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458419 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-wuj1wseg1SBp69N03984uDYB_sSUSc5m67pFvlz5Pz7 Scale = 1:28.8 1 2 3 4 5 6 10 9 8 7 4x8 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 16-0-8 16-0-8 4-0-6 4-0-6 16-0-8 12-0-2 0-4-102-8-82-10-130-1-82-8-80-1-89.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-1-6] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.18 0.11 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.00 0.00 -0.00 (loc) 1 1 7 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 44 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-4-5. (lb) - Max Horz 2=86(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 7, 9, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 7, 2 except 9=328(LC 11), 10=300(LC 1), 8=350(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-9=-250/105, 5-8=-262/105 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 9, 10, 8. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB02 Truss Type Piggyback Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458420 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-wuj1wseg1SBp69N03984uDYAFsRISaam67pFvlz5Pz7 Scale: 3/8"=1' 1 2 3 4 5 6 7 12 11 10 9 8 4x8 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-0-8 16-0-8 16-0-8 16-0-8 0-4-105-0-85-2-130-1-85-0-80-1-89.00 12 Plate Offsets (X,Y)-- [4:0-4-0,0-1-6] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.23 0.19 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.00 0.00 -0.00 (loc) 1 1 8 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 54 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-4-5. (lb) - Max Horz 2=158(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 8, 10, 9, 11 except 12=-101(LC 6) Max Grav All reactions 250 lb or less at joint(s) 8, 2, 11 except 10=334(LC 11), 12=312(LC 1), 9=544(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 6-9=-272/112 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 10, 9, 11 except (jt=lb) 12=101. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB03 Truss Type GABLE Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458421 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-O5HQ8CeIomJgkJyCdsfJRQ5I?GlFB?0vKnYoRCz5Pz6 Scale = 1:47.1 1 2 3 4 5 6 7 12 11 10 9 8 4x8 4x8 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 16-0-8 16-0-8 10-3-1 10-3-1 15-0-15 4-9-14 16-0-8 0-11-9 0-4-107-4-87-6-130-1-86-10-20-1-87-4-89.00 12 Plate Offsets (X,Y)-- [2:0-1-13,0-1-8], [4:0-4-0,0-1-6], [6:0-4-0,0-1-6] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.42 0.27 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.01 0.00 -0.01 (loc) 1 1 8 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 64 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 8-9. REACTIONS.All bearings 15-4-5. (lb) - Max Horz 2=219(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 9, 10, 11 except 8=-120(LC 10), 12=-148(LC 6) Max Grav All reactions 250 lb or less at joint(s) 8, 2, 11 except 9=402(LC 11), 10=347(LC 11), 12=553(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-340/202 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 10, 11 except (jt=lb) 8=120, 12=148. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB04 Truss Type GABLE Qty 5 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458422 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-sHroLYfwZ4RXLTXOAaAYzedXMg7KwSw3ZRIL_ez5Pz5 Scale = 1:58.0 1 2 3 4 5 6 10 9 8 711 4x6 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 16-0-8 16-0-8 12-8-0 12-8-0 16-0-8 3-4-8 0-4-109-4-80-1-86-10-20-1-89.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.19 0.15 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.00 0.00 -0.00 (loc) 1 1 7 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 60 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-8 REACTIONS.All bearings 15-4-5. (lb) - Max Horz 2=237(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 7, 2 except 9=-104(LC 6), 10=-109(LC 6) Max Grav All reactions 250 lb or less at joint(s) 7, 2 except 8=454(LC 1), 9=496(LC 10), 10=394(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-9=-255/153, 3-10=-255/154 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2 except (jt=lb) 9=104, 10=109. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB05 Truss Type GABLE Qty 2 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458423 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-sHroLYfwZ4RXLTXOAaAYzedWwg7BwSw3ZRIL_ez5Pz5 Scale = 1:58.0 1 2 3 4 5 6 7 13 12 11 10 9 814 4x6 2x4 2x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 18-9-8 18-9-8 12-8-0 12-8-0 18-9-8 6-1-8 0-4-109-4-80-1-84-9-60-1-89.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.21 0.16 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.00 0.00 -0.00 (loc) 1 1 8 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-10 REACTIONS.All bearings 18-1-5. (lb) - Max Horz 2=202(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 8, 2, 9 except 11=-103(LC 6), 13=-109(LC 6) Max Grav All reactions 250 lb or less at joint(s) 8, 2 except 10=473(LC 1), 11=492(LC 10), 13=396(LC 1), 9=390(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-11=-255/152, 3-13=-256/154 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2, 9 except (jt=lb) 11=103, 13=109. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB06 Truss Type Piggyback Qty 3 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458424 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-KTPAZugZKNaOzd6bkHhnWrAiO3TQfvACo51vW4z5Pz4 Scale = 1:59.2 1 2 3 4 5 6 7 8 9 15 14 13 12 11 101617 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 25-4-0 25-4-0 12-8-0 12-8-0 25-4-0 12-8-0 0-4-109-4-80-1-80-4-100-1-89.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.17 0.16 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.01 0.01 -0.00 (loc) 9 9 8 9 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 84 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12 REACTIONS.All bearings 23-11-11. (lb) - Max Horz 2=-211(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2 except 14=-103(LC 6), 15=-109(LC 6), 11=-103(LC 7), 10=-109(LC 7) Max Grav All reactions 250 lb or less at joint(s) 2, 8 except 12=395(LC 1), 14=495(LC 10), 15=394(LC 1), 11=495(LC 11), 10=394(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-14=-255/152, 3-15=-255/153, 6-11=-255/152, 7-10=-255/153 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 14=103, 15=109, 11=103, 10=109. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB07 Truss Type GABLE Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458425 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-ogyYmDhB5hiFbnhnI?C023jqOTojOLdM1lnS2Xz5Pz3 Scale = 1:55.9 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 6x6 6x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 31-4-0 31-4-0 9-6-8 9-6-8 21-9-8 12-3-0 31-4-0 9-6-8 0-4-106-10-17-0-60-1-80-4-100-1-86-10-19.00 12 Plate Offsets (X,Y)-- [2:0-1-13,0-1-8], [9:0-1-13,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.34 0.22 0.28 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.01 0.02 0.00 -0.01 (loc) 10 10 9 10 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 101 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 4-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 29-11-11. (lb) - Max Horz 2=155(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 2, 13, 15, 16 except 17=-134(LC 6), 11=-133(LC 7) Max Grav All reactions 250 lb or less at joint(s) 2, 9 except 12=420(LC 11), 13=499(LC 10), 15=503(LC 11), 16=423(LC 10), 17=501(LC 10), 11=502(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 6-13=-260/107, 5-15=-262/109, 3-17=-307/183, 8-11=-307/182 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 13, 15, 16 except (jt=lb) 17=134, 11=133. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB08 Truss Type Piggyback Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458426 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-GsWw_Zipr?q6CxGzsikFbGF1Ot9d7rRVFPW0azz5Pz2 Scale = 1:56.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 22 21 20 19 18 17 16 15 3x4 3x4 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 31-4-0 31-4-0 6-5-3 6-5-3 24-10-13 18-5-11 31-4-0 6-5-3 0-4-104-6-14-8-60-1-80-4-100-1-84-6-19.00 12 Plate Offsets (X,Y)-- [4:0-2-0,Edge], [11:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.20 0.18 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 14 14 13 13 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 93 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 4-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 29-11-11. (lb) - Max Horz 2=100(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 18, 20, 21, 22, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 2, 13 except 18=472(LC 1), 20=502(LC 11), 21=384(LC 10), 22=283(LC 10), 17=502(LC 10), 16=384(LC 11), 15=283(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 6-20=-251/107, 8-17=-251/105 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 20, 21, 22, 17, 16, 15. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss PB09 Truss Type Piggyback Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458427 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-k24JBviRcIyzq4rAPQFU8UoCdHWAsJieU3GZ7Pz5Pz1 Scale = 1:56.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 22 21 20 19 18 17 16 15 3x4 3x4 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 31-4-0 31-4-0 3-3-13 3-3-13 28-0-3 24-8-5 31-4-0 3-3-13 0-4-102-2-12-4-60-1-80-4-100-1-82-2-19.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge], [12:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.17 0.09 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 14 14 13 13 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 81 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-12. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 29-11-11. (lb) - Max Horz 2=46(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 2, 18, 20, 21, 22, 17, 16, 15, 13 Max Grav All reactions 250 lb or less at joint(s) 2, 13 except 18=321(LC 10), 20=318(LC 10), 21=335(LC 11), 22=314(LC 10), 17=318(LC 11), 16=335(LC 10), 15=314(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-21=-253/108, 10-16=-253/107 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 18, 20, 21, 22, 17, 16, 15, 13. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T01 Truss Type Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458428 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-CFehOFj3Nc4qSEQMz7mjghLEkhgVbZwojj?6fsz5Pz0 Scale = 1:107.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 25 24 23 22 21 20 19 18 17 16333435363738 4x6 6x6 4x6 4x6 8x10 8x10 4x6 3x8 MT18HS 4x6 2x4 3x6 5x8 2x4 4x6 4x6 6x6 3x8 4x6 3x6 2x4 3x8 MT18HS 5x12 3x8 MT18HS 7-11-8 7-11-8 15-8-9 7-9-0 23-6-2 7-9-9 31-4-14 7-10-13 39-2-7 7-9-9 46-11-7 7-9-0 52-3-0 5-3-9 56-11-0 4-8-0 -1-2-8 1-2-8 7-11-8 7-11-8 15-8-9 7-9-0 23-6-2 7-9-9 31-4-14 7-10-13 39-2-7 7-9-9 46-11-7 7-9-0 52-3-0 5-3-9 56-11-0 4-8-0 58-1-8 1-2-8 0-10-1412-6-012-8-50-6-1412-6-09.00 12 6.00 12 Plate Offsets (X,Y)-- [14:1-0-0,0-0-8], [17:0-2-8,0-1-8], [19:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.72 0.79 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.34 -0.66 0.26 0.11 (loc) 19-20 19-20 14 20-22 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 347 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 *Except* 1-5: 2x6 SP 2400F 2.0E BOT CHORD 2x4 SP 2400F 2.0E *Except* 21-24: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 4-25,4-23,12-19,12-17,13-17,13-16: 2x3 SPF No.2 WEDGE Right: 2x4 SP No.3 SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-2 oc purlins, except 2-0-0 oc purlins (3-9-1 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-23, 6-22, 7-22, 9-22, 9-20, 10-20, 12-19 REACTIONS.(lb/size)2=2922/0-3-8, 14=2796/0-3-8 Max Horz 2=-281(LC 4) Max Uplift 2=-81(LC 6), 14=-95(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-4076/300, 4-6=-3534/374, 6-7=-3318/399, 7-9=-3317/398, 9-10=-3395/404, 10-12=-3761/388, 12-13=-4578/361, 13-14=-5285/365 BOT CHORD 2-25=-201/3110, 23-25=-201/3110, 22-23=-149/2733, 20-22=-105/3393, 19-20=0/2898, 17-19=-118/3644, 16-17=-232/4624, 14-16=-235/4625 WEBS 4-25=0/300, 4-23=-497/196, 6-23=-32/661, 6-22=-234/1196, 7-22=-508/210, 9-20=-510/298, 10-20=-241/1058, 10-19=-29/952, 12-19=-962/192, 12-17=0/720, 13-17=-1084/126 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T02 Truss Type PIGGYBACK BASE Qty 5 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458429 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-CFehOFj3Nc4qSEQMz7mjghLBBhg8bftojj?6fsz5Pz0 Scale = 1:75.0 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 21 22 23 24 25 3x4 6x8 3x4 6x16 3x6 8x10 4x6 3x4 3x6 2x4 3x6 2x4 5x12 3x4 3x4 7-6-0 7-6-0 14-9-8 7-3-8 22-8-0 7-10-8 30-10-0 8-2-0 -1-2-8 1-2-8 7-6-0 7-6-0 14-9-8 7-3-8 22-8-0 7-10-8 30-10-0 8-2-0 0-10-1412-0-010-1-1212-0-09.00 12 Plate Offsets (X,Y)-- [6:0-4-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.95 0.81 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.35 0.45 0.05 (loc) 11-13 10-11 21 15-19 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 164 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 2-14: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 4-15,4-13: 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 2-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-5-15 max.): 6-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-13, 6-11, 7-11, 9-11 REACTIONS.(lb/size)2=1594/0-3-8, 21=1563/0-3-0 Max Horz 2=383(LC 6) Max Uplift 2=-36(LC 6), 21=-95(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1978/67, 4-6=-1443/126, 6-7=-840/103, 7-9=-840/103 BOT CHORD 2-15=-277/1491, 13-15=-277/1491, 11-13=-152/1050 WEBS 4-15=0/294, 4-13=-585/189, 6-13=-27/692, 6-11=-376/113, 7-11=-573/234, 9-11=-177/1440, 9-21=-1590/174 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 21 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 21. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T03 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458430 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-hRC3cbkh8wCh4O_YXrHyDvtXV4BHKB1xxNlgBIz5Pz? Scale = 1:35.1 1 2 3 4 7 6 5 5x6 2x4 2x4 3x4 3x6 3x4 3-9-4 3-9-4 7-7-8 3-10-4 -1-2-8 1-2-8 3-9-4 3-9-4 7-7-8 3-10-4 1-5-95-8-75-10-55-4-150-3-85-8-714.00 12 Plate Offsets (X,Y)-- [3:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.21 0.12 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 -0.00 0.00 (loc) 5-6 5-6 5 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 40 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5,2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=382/0-3-8, 5=286/0-1-8 Max Horz 7=216(LC 6) Max Uplift 5=-60(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-250/26, 2-7=-351/47 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T04 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458431 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-9dmRpxlJvDKYhYZl5YoBl6QgjUWY3cQ5A1UDkkz5Pz_ Scale = 1:43.8 1 2 3 4 7 6 5 5x6 2x4 2x4 3x4 5x6 3x4 5-0-11 5-0-11 7-7-8 2-6-13 -1-2-8 1-2-8 5-0-11 5-0-11 7-7-8 2-6-13 1-5-97-2-77-4-56-10-150-3-87-2-714.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-8], [3:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.37 0.18 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.04 -0.00 0.00 (loc) 6-7 6-7 5 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 45 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5,2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=382/0-3-8, 5=286/0-1-8 Max Horz 7=263(LC 6) Max Uplift 5=-106(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-336/5 BOT CHORD 6-7=-342/74 WEBS 2-6=-41/291 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=106. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T05 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458432 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-9dmRpxlJvDKYhYZl5YoBl6Qa2UUy3dW5A1UDkkz5Pz_ Scale = 1:54.3 1 2 3 4 7 6 5 5x6 2x4 3x4 3x4 6x8 3x4 6-4-1 6-4-1 7-7-8 1-3-7 -1-2-8 1-2-8 6-4-1 6-4-1 7-7-8 1-3-7 1-5-98-8-78-10-58-4-150-3-88-8-714.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.73 0.28 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.10 -0.00 0.01 (loc) 6-7 6-7 5 6-7 l/defl >999 >904 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF No.2, 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 8-8-9 oc bracing. WEBS 1 Row at midpt 4-5, 3-5 REACTIONS.(lb/size)7=382/0-3-8, 5=286/0-1-8 Max Horz 7=309(LC 6) Max Uplift 5=-163(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-323/0 BOT CHORD 6-7=-458/141 WEBS 3-6=0/253, 3-5=-354/279, 2-6=-93/428 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=163. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T06 Truss Type Common Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458433 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-dqKp1HlygXSPJi8xeFJQIKzr_uiwo2eEPhEnFAz5Pyz Scale = 1:57.3 1 2 3 4 5 6 7 8 10 91920 21 22 8x10 4x6 3x8 4x6 2x4 3x8 2x4 8x10 4x6 10-10-8 10-10-8 21-9-0 10-10-8 5-6-8 5-6-8 10-10-8 5-4-0 16-2-8 5-4-0 21-9-0 5-6-8 22-11-8 1-2-8 0-10-149-0-120-10-149.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.34 0.81 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.18 -0.46 0.03 0.04 (loc) 9-13 9-13 1 9-13 l/defl >999 >567 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 81 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=953/Mechanical, 7=1029/0-3-8 Max Horz 1=-204(LC 4) Max Uplift 1=-33(LC 6), 7=-71(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1124/131, 3-4=-899/139, 4-5=-898/138, 5-7=-1122/130 BOT CHORD 1-9=-54/846, 7-9=0/840 WEBS 4-9=-55/649, 5-9=-289/162, 3-9=-296/165 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T07 Truss Type Roof Special Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458434 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-50tCEdmaRraGxsj7CzqfrXV_jI2IXSLOeKzKndz5Pyy Scale = 1:57.8 1 2 3 4 5 6 7 8 9 14 13 12 11 10 22 23 6x10 4x6 4x6 4x8 3x4 3x6 2x4 3x8 3x6 3x6 5x8 2x4 2x4 5-6-8 5-6-8 10-10-8 5-4-0 19-1-0 8-2-8 21-9-0 2-8-0 23-9-0 2-0-0 5-6-8 5-6-8 10-10-8 5-4-0 14-11-12 4-1-4 19-1-0 4-1-4 23-9-0 4-8-0 24-11-8 1-2-8 0-10-142-10-149-0-120-6-149.00 12 6.00 12 Plate Offsets (X,Y)-- [8:0-3-8,Edge], [8:0-0-9,0-5-12], [8:0-0-4,0-0-9], [11:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.47 0.80 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.20 -0.46 0.05 0.06 (loc) 11-12 11-12 8 11-12 l/defl >999 >558 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 96 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-10: 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 2-3-8 except (jt=length) 1=Mechanical. (lb) - Max Horz 1=-210(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 10 Max Grav All reactions 250 lb or less at joint(s) 10, 10 except 1=969(LC 1), 8=924(LC 1), 8=924(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1203/111, 3-4=-971/151, 4-5=-950/160, 5-6=-1782/151, 6-7=-1609/55, 7-8=-1561/15 BOT CHORD 1-14=-37/891, 12-14=-37/891, 11-12=0/959, 10-11=0/1380, 8-10=0/1380 WEBS 3-12=-286/144, 4-12=-97/779, 5-12=-447/139, 5-11=-24/736, 6-11=-445/118 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 10, 8. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T08 Truss Type Roof Special Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458435 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-50tCEdmaRraGxsj7CzqfrXVy_I3OXRdOeKzKndz5Pyy Scale = 1:55.4 1 2 3 4 5 6 7 8 12 11 10 92021 6x10 4x6 4x6 4x8 3x4 3x6 2x4 3x8 3x6 4x6 6x8 5-6-8 5-6-8 10-10-8 5-4-0 19-1-0 8-2-8 23-9-0 4-8-0 5-6-8 5-6-8 10-10-8 5-4-0 14-11-12 4-1-4 19-1-0 4-1-4 23-9-0 4-8-0 24-11-8 1-2-8 0-10-142-10-149-0-120-6-149.00 12 6.00 12 Plate Offsets (X,Y)-- [7:0-3-8,Edge], [7:0-0-9,0-5-12], [7:0-0-4,0-0-9], [9:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.58 0.73 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.20 -0.45 0.05 0.05 (loc) 9-10 9-10 7 9-10 l/defl >999 >627 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 95 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 WEDGE Right: 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=985/Mechanical, 7=1088/0-3-8 Max Horz 1=-210(LC 4) Max Uplift 1=-34(LC 6), 7=-82(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1227/121, 3-4=-995/162, 4-5=-974/171, 5-6=-1964/229, 6-7=-1773/112 BOT CHORD 1-12=-42/909, 10-12=-42/909, 9-10=0/1001, 7-9=-12/1518 WEBS 3-10=-285/144, 4-10=-109/806, 5-10=-486/155, 5-9=-94/902, 6-9=-554/157 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T09 Truss Type Piggyback Base Qty 3 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458436 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-ZCRaSznCC8i6Y0IJmgMuNl22jiOIGqBXs_jtJ3z5Pyx Scale = 1:68.5 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 17 3x4 4x8 3x4 6x16 3x6 3x6 3x4 3x4 2x4 5x8 4x8 3x4 10-9-8 10-9-8 18-8-0 7-10-8 26-10-0 8-2-0 5-3-0 5-3-0 10-9-8 5-6-8 18-8-0 7-10-8 26-10-0 8-2-0 3-10-1412-0-010-1-1212-0-09.00 12 Plate Offsets (X,Y)-- [3:0-6-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.90 0.82 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.43 -0.89 0.41 0.03 (loc) 10-11 10-11 13 8-10 l/defl >749 >359 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 154 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 9-11: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-10,2-11: 2x3 SPF No.2, 1-11: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purlins, except end verticals, and 2-0-0 oc purlins (4-5-7 max.): 3-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8, 4-8, 6-8, 2-11 REACTIONS.(lb/size)11=1352/0-3-8, 13=1364/0-3-0 Max Horz 11=247(LC 6) Max Uplift 13=-102(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1102/116, 3-4=-700/98, 4-6=-699/98 BOT CHORD 10-11=-233/727, 8-10=-134/799 WEBS 3-10=-29/393, 4-8=-575/232, 6-8=-170/1190, 2-11=-1188/13, 6-13=-1388/165 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=102. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T10 Truss Type Piggyback Base Qty 2 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458437 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-1O?yfIoqzSqzA9tWKOt7wybD25jt?Ffg5eSRsVz5Pyw Scale = 1:70.7 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 3x4 4x6 3x4 6x16 3x6 3x6 3x8 3x4 2x4 3x8 2x4 6x8 4x8 3x4 10-9-8 10-9-8 17-0-1 6-2-9 23-0-15 6-0-13 29-7-0 6-6-1 5-3-0 5-3-0 10-9-8 5-6-8 17-0-1 6-2-9 23-0-15 6-0-13 29-7-0 6-6-1 3-10-1412-0-010-1-1212-0-09.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.92 0.79 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.45 -0.92 0.40 0.04 (loc) 12-13 12-13 15 9-10 l/defl >776 >383 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 186 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 11-13: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-12,2-13: 2x3 SPF No.2, 1-13: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except end verticals, and 2-0-0 oc purlins (5-4-6 max.): 3-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-12, 4-9, 6-9, 7-9, 2-13 REACTIONS.(lb/size)13=1484/0-3-8, 15=1510/0-3-0 Max Horz 13=247(LC 6) Max Uplift 15=-110(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1250/134, 3-4=-917/147, 4-6=-678/80, 6-7=-678/80 BOT CHORD 12-13=-244/815, 10-12=-133/960, 9-10=-133/960 WEBS 3-12=0/355, 4-10=0/260, 4-9=-614/114, 6-9=-435/159, 7-9=-165/1389, 2-13=-1342/32, 7-15=-1533/169 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 15=110. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T11 Truss Type Piggyback Base Qty 3 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458438 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-VbZKseoSkmyqoJSit5OMSA7OBV1AkmaqKIC_Oyz5Pyv Scale = 1:74.2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 91718192021 3x4 6x8 3x6 5x8 5x6 3x6 3x4 3x6 2x4 3x8 3x4 5x6 5x8 4x8 3x4 3x6 10-9-8 10-9-8 19-3-7 8-5-15 27-7-9 8-4-3 36-1-8 8-5-15 37-3-0 1-1-8 5-3-0 5-3-0 10-9-8 5-6-8 19-3-7 8-5-15 27-7-9 8-4-3 36-1-8 8-5-15 37-3-0 1-1-8 3-10-1412-0-011-1-1412-0-09.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-8], [3:0-4-8,0-1-12], [7:0-6-0,0-2-0], [8:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.90 0.92 0.76 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.42 -0.87 0.06 0.07 (loc) 15-16 15-16 9 13 l/defl >999 >507 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 234 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 14-16: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-15: 2x3 SPF No.2, 1-16: 2x4 SPF-S Stud, 8-9: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-15 oc purlins, except end verticals, and 2-0-0 oc purlins (3-3-5 max.): 3-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-13, 4-13, 6-13, 6-11, 7-11, 2-16, 8-9 2 Rows at 1/3 pts 7-10 REACTIONS.(lb/size)16=1891/0-3-8, 9=1942/0-3-8 Max Horz 16=231(LC 6) Max Uplift 16=-49(LC 5), 9=-201(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1723/188, 3-4=-1544/202, 4-6=-1543/203, 6-7=-1217/150, 8-9=-2068/130 BOT CHORD 15-16=-253/1091, 13-15=-170/1298, 11-13=-152/1217 WEBS 2-15=-80/424, 3-13=-162/498, 4-13=-534/221, 6-13=-94/562, 6-11=-993/289, 7-11=-228/1753, 7-10=-1595/315, 2-16=-1841/87, 8-10=-183/1969 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16 except (jt=lb) 9=201. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T12 Truss Type ROOF SPECIAL Qty 7 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458439 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-zn7i4_p4V34hPT1uRpvb?NgkWvVpTGKzYyxXwOz5Pyu Scale = 1:66.4 1 2 3 4 5 10 9 8 7 6 3x4 4x6 4x6 4x6 3x4 5x6 5x6 3x8 3x8 3x8 3-0-13 3-0-13 8-0-0 4-11-3 12-11-3 4-11-3 16-0-0 3-0-13 3-0-13 3-0-13 8-0-0 4-11-3 12-11-3 4-11-3 16-0-0 3-0-13 1-2-610-6-61-2-63-2-1414.00 12 14.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.22 0.44 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.09 -0.23 0.48 0.07 (loc) 7-8 7-8 6 8-9 l/defl >999 >810 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 75 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-10,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-6-4 oc bracing. REACTIONS.(lb/size)10=628/0-3-8, 6=628/0-3-8 Max Horz 10=-223(LC 4) Max Uplift 10=-30(LC 7), 6=-30(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-643/119, 1-2=-2034/344, 2-3=-688/98, 3-4=-688/108, 4-5=-2034/117, 5-6=-643/72 BOT CHORD 9-10=-344/375, 8-9=-386/1203, 7-8=-32/1203 WEBS 3-8=-41/580, 4-8=-852/189, 4-7=0/1041, 5-7=-33/1541, 2-8=-852/356, 2-9=-348/1041, 1-9=-240/1541 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 10, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T13 Truss Type Common Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458440 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-zn7i4_p4V34hPT1uRpvb?Ngd6vPkTErzYyxXwOz5Pyu Scale = 1:77.1 1 2 3 4 5 6 7 8 9 13 12 11 1014151617 3x4 4x6 3x4 3x4 3x8 3x4 3x4 3x4 4x6 4x6 3x4 9-9-4 9-9-4 19-6-8 9-9-4 -1-2-8 1-2-8 4-0-0 4-0-0 9-9-4 5-9-4 15-6-8 5-9-4 19-6-8 4-0-0 20-9-0 1-2-8 1-5-912-10-51-5-914.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.70 0.77 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.18 -0.45 0.02 0.23 (loc) 11-13 11-13 10 10-11 l/defl >999 >519 n/a >989 L/d 360 240 n/a 240 PLATES MT20 Weight: 101 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-11: 2x4 SPF No.2, 2-13,8-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-11 REACTIONS.(lb/size)13=968/0-10-0, 10=968/0-10-0 Max Horz 13=-323(LC 4) Max Uplift 13=-210(LC 6), 10=-210(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-249/287, 3-5=-705/449, 5-7=-705/449, 7-8=-249/287, 2-13=-309/271, 8-10=-309/271 BOT CHORD 11-13=-236/462, 10-11=-74/462 WEBS 5-11=-546/521, 3-13=-624/99, 7-10=-624/99 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=210, 10=210. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T14 Truss Type Common Qty 2 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458441 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Szh5HKqiGNCY1dc5?WQqYbCnhJmHCh?7nch5Sqz5Pyt Scale = 1:77.1 1 2 3 4 5 6 7 11 10 9 812131415 3x4 4x6 2x4 3x4 3x4 3x8 3x4 3x4 4x6 3x8 9-9-4 9-9-4 19-3-4 9-6-0 -1-2-8 1-2-8 4-0-0 4-0-0 9-9-4 5-9-4 15-6-8 5-9-4 19-3-4 3-8-12 1-5-912-10-51-9-514.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.71 0.75 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.46 0.02 0.24 (loc) 9-11 9-11 8 9-11 l/defl >999 >499 n/a >939 L/d 360 240 n/a 240 PLATES MT20 Weight: 98 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-9: 2x4 SPF No.2, 2-11,7-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-9 REACTIONS.(lb/size)11=958/0-10-0, 8=872/0-3-8 Max Horz 11=320(LC 5) Max Uplift 11=-206(LC 6), 8=-198(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-251/290, 3-5=-692/442, 5-6=-693/442, 2-11=-310/273 BOT CHORD 9-11=-232/455, 8-9=-170/438 WEBS 5-9=-534/502, 3-11=-609/88, 6-8=-660/219 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=206, 8=198. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T15 Truss Type Common Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458442 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-wAFTVgrL1hKPfnBHZEx34olyQj6Ux7AG0GQe?Gz5Pys Scale = 1:77.1 1 2 3 4 5 9 8 7 610111213 2x4 4x6 2x4 3x4 3x4 3x8 3x4 4x6 3x8 9-9-4 9-9-4 19-3-4 9-6-0 4-0-0 4-0-0 9-9-4 5-9-4 15-6-8 5-9-4 19-3-4 3-8-12 1-5-912-10-51-9-514.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.71 0.75 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.46 0.02 0.24 (loc) 7-9 7-9 6 7-9 l/defl >999 >499 n/a >948 L/d 360 240 n/a 240 PLATES MT20 Weight: 96 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-7: 2x4 SPF No.2, 1-9,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.(lb/size)9=874/0-10-0, 6=875/0-3-8 Max Horz 9=296(LC 5) Max Uplift 9=-194(LC 7), 6=-198(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-264/237, 2-3=-696/442, 3-4=-696/442 BOT CHORD 7-9=-231/465, 6-7=-170/440 WEBS 3-7=-535/508, 2-9=-599/142, 4-6=-663/218 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=194, 6=198. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T16 Truss Type Common Qty 2 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458443 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-wAFTVgrL1hKPfnBHZEx34ol_ej6vx8TG0GQe?Gz5Pys Scale = 1:77.1 1 2 3 4 5 9 8 7 610111213 2x4 4x6 2x4 3x4 3x8 3x4 3x4 3x8 3x8 9-6-0 9-6-0 19-0-0 9-6-0 3-8-12 3-8-12 9-6-0 5-9-4 15-3-4 5-9-4 19-0-0 3-8-12 1-9-512-10-51-9-514.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.63 0.72 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.17 -0.40 0.02 0.21 (loc) 7-9 7-9 6 7-9 l/defl >999 >558 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 95 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-7: 2x4 SPF No.2, 1-9,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.(lb/size)9=862/0-3-8, 6=862/0-3-8 Max Horz 9=-265(LC 4) Max Uplift 9=-194(LC 7), 6=-194(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-680/435, 3-4=-680/435 BOT CHORD 7-9=-228/432, 6-7=-166/432 WEBS 3-7=-523/483, 2-9=-645/209, 4-6=-645/209 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=194, 6=194. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T17 Truss Type PIGGYBACK BASE Qty 3 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458444 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-OMpri0szo_SGGxlT6xSId0I5N6R9gWoPFwACXjz5Pyr Scale = 1:79.7 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 101920212223 5x6 5x8 3x6 5x8 5x6 3x4 3x6 6x6 5x8 2x4 2x4 3x8 2x4 6x10 5x8 3x4 3x6 3x6 4-9-8 4-9-8 12-8-6 7-10-14 20-5-8 7-9-2 28-2-10 7-9-2 36-1-8 7-10-14 37-3-0 1-1-8 4-9-8 4-9-8 12-8-6 7-10-14 20-5-8 7-9-2 28-2-10 7-9-2 36-1-8 7-10-14 37-3-0 1-1-8 8-4-1412-0-011-1-1412-0-09.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-2-0], [2:0-6-0,0-2-0], [8:0-6-0,0-2-0], [9:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.89 0.79 1.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.20 -0.39 0.06 0.07 (loc) 11-12 11-12 10 14 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 254 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 1-18: 2x4 SPF-S Stud, 1-17: 2x3 SPF No.2 9-10: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-2 oc purlins, except end verticals, and 2-0-0 oc purlins (3-11-8 max.): 2-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-17, 2-15, 3-15, 5-15, 5-12, 7-12, 8-12, 8-11, 9-10 2 Rows at 1/3 pts 1-18 REACTIONS.(lb/size)18=1948/Mechanical, 10=1940/0-3-8 Max Horz 18=92(LC 6) Max Uplift 18=-139(LC 5), 10=-205(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-963/118, 2-3=-1412/198, 3-5=-1411/198, 5-7=-1160/147, 7-8=-1161/147, 1-18=-1864/157, 9-10=-2043/142 BOT CHORD 15-17=-121/702, 14-15=-204/1576, 12-14=-204/1576 WEBS 2-17=-886/170, 2-15=-179/1285, 3-15=-511/211, 5-15=-312/40, 5-14=0/434, 5-12=-753/99, 7-12=-513/206, 8-12=-234/1746, 8-11=-1576/304, 1-17=-102/1401, 9-11=-183/1915 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 18=139, 10=205. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T18 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458445 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-sYMDwMsbYIb7u4Kgge_X9DqFVWmqP1MZTavl39z5Pyq Scale = 1:80.2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 91718192021 5x6 6x6 3x6 5x8 3x4 3x4 3x6 6x6 4x6 3x4 2x4 4x8 3x6 5x8 3x6 3x6 5-0-0 5-0-0 12-11-0 7-11-0 20-11-12 8-0-12 29-0-8 8-0-12 37-3-0 8-2-8 5-0-0 5-0-0 12-11-0 7-11-0 20-11-12 8-0-12 29-0-8 8-0-12 37-3-0 8-2-8 8-4-1411-11-912-1-1411-11-99.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-2-0], [10:0-3-8,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.93 0.89 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.39 0.05 0.07 (loc) 12-14 12-14 9 12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 230 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 8-9: 2x4 SPF 2100F 1.8E, 1-16: 2x4 SPF-S Stud, 1-15: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-14 oc purlins, except end verticals, and 2-0-0 oc purlins (3-11-6 max.): 2-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9, 2-15, 2-14, 3-14, 3-12, 5-12, 7-12, 7-10, 8-10 2 Rows at 1/3 pts 1-16 REACTIONS.(lb/size)9=1964/0-3-8, 16=1949/Mechanical Max Horz 16=108(LC 6) Max Uplift 9=-212(LC 4), 16=-65(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-953/102, 2-3=-1434/161, 3-5=-1522/160, 5-7=-1522/160, 7-8=-1095/119, 8-9=-1769/252, 1-16=-1868/119 BOT CHORD 14-15=-123/720, 12-14=-160/1431, 10-12=-119/1095 WEBS 2-15=-897/169, 2-14=-180/1293, 3-14=-679/250, 5-12=-463/186, 7-12=-89/750, 7-10=-1148/277, 8-10=-206/1899, 1-15=-98/1411 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16 except (jt=lb) 9=212. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T19 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458446 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Klwb7itDJcj_WEvsEMVmiRNZMw6U8TZiiEfIbbz5Pyp Scale = 1:39.2 1 2 3 4 5 8 7 6 9 10 6x6 2x4 3x6 2x4 3x8 3x4 4x6 4-7-1 4-7-1 13-11-0 9-3-15 -1-2-8 1-2-8 4-7-1 4-7-1 9-1-12 4-6-12 13-11-0 4-9-4 1-5-96-7-146-9-126-7-1414.00 12 Plate Offsets (X,Y)-- [3:0-3-15,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.34 0.80 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.29 -0.64 0.01 0.00 (loc) 6-7 6-7 6 7 l/defl >560 >257 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 64 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)6=638/0-3-8, 8=681/0-3-8 Max Horz 8=246(LC 6) Max Uplift 6=-72(LC 7), 8=-15(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-630/50, 3-4=-339/94, 2-8=-716/65 BOT CHORD 7-8=-280/42, 6-7=-89/294 WEBS 4-6=-473/154, 2-7=-15/347 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 8. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T20 Truss Type Roof Special Qty 2 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458447 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Klwb7itDJcj_WEvsEMVmiRNRew8q8SViiEfIbbz5Pyp Scale = 1:77.1 1 2 3 4 5 6 10 9 8 7 11 12 13 4x6 3x6 4x8 4x8 3x8 3x4 2x4 3x4 3x6 3x4 4-8-0 4-8-0 11-7-0 6-11-0 18-8-8 7-1-8 -1-2-8 1-2-8 4-8-0 4-8-0 11-7-0 6-11-0 18-8-8 7-1-8 0-6-1413-5-410-1-1213-5-46.00 12 9.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-0-9,0-5-12], [2:0-0-4,0-0-9], [6:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.84 0.65 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.21 0.37 0.04 (loc) 7-8 7-8 12 8-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-7: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-7 REACTIONS.(lb/size)2=861/0-3-8, 12=807/0-3-0 Max Horz 2=409(LC 6) Max Uplift 12=-196(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1301/0, 3-4=-763/0, 7-11=-106/674, 6-11=-106/674 BOT CHORD 2-10=-196/1073, 8-10=-198/1068, 7-8=-124/528 WEBS 3-8=-578/80, 4-8=0/468, 4-7=-770/179, 6-12=-813/198 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=196. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T21 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458448 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-oxU_K1ur4vrr7OU2n30?FewigKZ2t4SsxuOs82z5Pyo Scale = 1:27.8 1 2 3 6 5 4 4x10 2x4 3x4 2x4 3x4 3x6 1-10-3 1-10-3 7-10-8 6-0-5 1-10-3 1-10-3 7-10-8 6-0-5 3-1-44-3-94-5-144-3-99.00 12 Plate Offsets (X,Y)-- [2:0-5-0,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.50 0.33 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.09 0.00 -0.00 (loc) 4-5 4-5 4 4-5 l/defl >999 >785 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 7-10-8. (lb) - Max Horz 6=35(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 4, 6 Max Grav All reactions 250 lb or less at joint(s) 4, 4, 6 except 5=326(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-263/109 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T22 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458449 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-G72MYNvTrDzilY3ELnXEnsSv4kyRcUv?9Y8PgUz5Pyn Scale = 1:40.3 1 2 3 6 5 4 3x6 4x10 2x4 3x4 2x4 3x4 4-11-8 4-11-8 7-10-8 2-11-0 4-11-8 4-11-8 7-10-8 2-11-0 3-1-46-7-96-9-146-7-99.00 12 Plate Offsets (X,Y)-- [2:0-5-0,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.27 0.19 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.04 -0.00 0.00 (loc) 5-6 5-6 4 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 42 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=305/0-3-8, 6=305/0-3-8 Max Horz 6=107(LC 6) Max Uplift 4=-70(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-260/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T23 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458450 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-G72MYNvTrDzilY3ELnXEnsSvRkx2cVH?9Y8PgUz5Pyn Scale = 1:57.3 1 2 3 4 5 8 7 6 6x8 4x10 2x4 3x6 3x4 3x6 3-7-11 3-7-11 7-7-8 3-11-13 -1-2-8 1-2-8 3-7-11 3-7-11 7-0-15 3-5-3 7-7-8 0-6-9 1-5-99-6-129-8-109-6-1214.00 12 Plate Offsets (X,Y)-- [4:0-5-15,0-3-0], [5:0-1-12,0-0-0], [6:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.31 0.21 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.01 -0.00 0.01 (loc) 6-7 6-7 6 6-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6: 2x4 SPF No.2, 2-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6, 4-6 REACTIONS.(lb/size)6=291/Mechanical, 8=372/0-3-8 Max Horz 8=297(LC 5) Max Uplift 6=-169(LC 5), 8=-41(LC 4) Max Grav 6=291(LC 1), 8=372(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-8=-342/84 BOT CHORD 7-8=-282/219 WEBS 4-6=-264/208 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 6=169. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T24 Truss Type Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458451 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-kKckljv6cX5ZNieRvU2TK3?1s7F5Ls89OCtzCwz5Pym Scale: 1/4"=1' 1 2 3 4 5 6 12 11 10 9 8 71314 4x6 6x6 6x6 2x4 3x4 3x4 3x8 2x4 3x4 2x4 4x6 4-8-0 4-8-0 10-9-8 6-1-8 16-11-0 6-1-8 21-7-0 4-8-0 4-8-0 4-8-0 10-9-8 6-1-8 16-11-0 6-1-8 21-7-0 4-8-0 22-9-8 1-2-8 2-6-117-10-28-0-02-6-117-10-214.00 12 Plate Offsets (X,Y)-- [1:0-2-8,0-1-8], [2:0-3-15,0-3-0], [4:0-3-15,0-3-0], [5:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.46 0.35 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.11 0.01 0.02 (loc) 9-11 9-11 7 9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 103 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-12,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)12=973/0-3-8, 7=1059/0-3-8 Max Horz 12=-231(LC 4) Max Uplift 12=-15(LC 5), 7=-38(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-850/129, 2-3=-743/170, 3-4=-743/170, 4-5=-851/149, 1-12=-949/91, 5-7=-1035/128 BOT CHORD 9-11=-130/494, 8-9=-54/489 WEBS 2-9=-127/426, 3-9=-433/176, 4-9=-123/430, 1-11=-70/533, 5-8=-63/532 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T25 Truss Type Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458452 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-DWA6z3wkNqDP_sDdTCZisHYBBXUz4Q7IdsdWkMz5Pyl Scale = 1:54.0 1 2 3 4 5 6 11 10 9 8 71213 6x8 6x6 6x6 2x4 3x4 3x8 3x4 2x4 6x8 3x8 5-11-7 5-11-7 15-7-9 9-8-2 21-7-0 5-11-7 5-11-7 5-11-7 10-9-8 4-10-1 15-7-9 4-10-1 21-7-0 5-11-7 22-9-8 1-2-8 2-6-119-4-29-6-02-6-119-4-214.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-5], [2:0-3-15,0-3-0], [4:0-3-15,0-3-0], [5:Edge,0-1-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.55 0.82 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.40 -0.70 0.01 0.01 (loc) 8-10 8-10 7 8-10 l/defl >636 >364 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 110 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-10,3-8: 2x4 SPF No.2, 1-11,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-10, 3-8 REACTIONS.(lb/size)11=959/0-3-8, 7=1045/0-3-8 Max Horz 11=-268(LC 4) Max Uplift 11=-5(LC 6), 7=-42(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-909/129, 2-3=-507/163, 3-4=-503/166, 4-5=-912/145, 1-11=-960/86, 5-7=-1046/123 BOT CHORD 10-11=-226/266, 8-10=-120/588 WEBS 2-10=-14/335, 4-8=-12/339, 1-10=-61/519, 5-8=-58/511 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T26 Truss Type Flat Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458453 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-DWA6z3wkNqDP_sDdTCZisHY66XZD4G7IdsdWkMz5Pyl Scale = 1:39.3 1 2 3 4 8 7 6 5 9 10 11 12 2x4 3x6 3x8 5x8 3x6 3x4 3x8 2x4 3x4 3x4 7-11-8 7-11-8 16-2-8 8-3-0 7-11-8 7-11-8 16-2-8 8-3-0 7-0-61-1-27-0-6Plate Offsets (X,Y)-- [4:0-2-8,0-3-0], [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.87 0.49 0.82 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.25 -0.03 0.01 (loc) 6-8 6-8 10 6 l/defl >999 >774 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 74 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-4, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=779/Mechanical, 10=753/0-3-0 Max Uplift 8=-55(LC 4), 10=-53(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-616/105, 1-2=-512/49, 2-4=-512/49 WEBS 1-6=-63/656, 2-6=-559/194, 4-6=-57/603, 4-10=-754/67 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 10. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T27 Truss Type Roof Special Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458454 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-hikUAPxM88LGc?op0v5xPU4OxxxIpsPRsWN3Hpz5Pyk Scale = 1:53.0 1 2 3 4 5 10 9 8 7 6 12 11 2x4 3x4 3x4 3x4 2x4 2x4 3x4 5x12 3x4 3x4 3x8 3x4 6-0-8 6-0-8 11-10-8 5-10-0 16-2-8 4-4-0 6-0-8 6-0-8 11-10-8 5-10-0 16-2-8 4-4-0 9-6-116-5-91-1-23-1-22-0-09-6-11Plate Offsets (X,Y)-- [7:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.42 0.37 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.07 -0.12 0.07 0.00 (loc) 9-10 9-10 11 9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 105 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-9,4-8: 2x4 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 5-8-9 oc bracing: 7-11. 10-0-0 oc bracing: 7-8 WEBS 1 Row at midpt 1-10, 2-9, 2-7 REACTIONS.(lb/size)10=516/Mechanical, 11=898/0-3-0 Max Uplift 10=-34(LC 4), 11=-77(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-376/71 BOT CHORD 7-11=-896/96, 4-7=-319/109 WEBS 1-9=-25/272, 2-7=-370/31 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 11. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T28 Truss Type Half Hip Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458455 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-hikUAPxM88LGc?op0v5xPU4OqxtLpsGRsWN3Hpz5Pyk Scale = 1:69.3 1 2 3 4 7 6 5 8 9 10 11 3x6 4x8 6x6 5x8 2x4 3x8 3x4 3x4 3x4 3x4 2-5-12 2-5-12 11-11-0 9-5-4 2-5-12 2-5-12 7-1-2 4-7-6 11-11-0 4-9-14 10-0-611-8-611-10-1111-8-61-1-29.00 12 Plate Offsets (X,Y)-- [2:0-4-0,0-1-6] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.42 0.62 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.27 -0.51 -0.07 0.01 (loc) 5-6 5-6 9 5 l/defl >512 >275 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 110 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 1-6: 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 2-6, 3-6, 3-5, 1-7, 4-9 REACTIONS.(lb/size)7=560/Mechanical, 9=577/0-3-8 Max Horz 7=50(LC 6) Max Uplift 9=-66(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-8=-73/465, 4-8=-73/465, 1-7=-716/0 WEBS 3-5=-306/128, 1-6=0/582, 4-9=-577/116 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss T29 Truss Type COMMON Qty 6 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458456 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-9vHtOly_vST7E9N0accAyidbkLAgYHbb4A6dpFz5Pyj Scale = 1:55.6 1 2 3 4 5 6 7 8 9 11 102021 22 23 8x10 4x6 3x4 4x6 2x4 3x8 2x4 8x10 4x6 10-11-8 10-11-8 21-11-0 10-11-8 -1-2-8 1-2-8 5-7-0 5-7-0 10-11-8 5-4-8 16-4-0 5-4-8 21-11-0 5-7-0 23-1-8 1-2-8 0-10-149-1-80-10-149.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.29 0.75 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.47 0.03 0.03 (loc) 10-14 10-14 2 10-14 l/defl >999 >561 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 84 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1037/0-3-8, 8=1037/0-3-8 Max Horz 2=194(LC 5) Max Uplift 2=-72(LC 6), 8=-72(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1130/130, 4-5=-905/138, 5-6=-905/138, 6-8=-1130/130 BOT CHORD 2-10=-52/847, 8-10=0/847 WEBS 5-10=-53/652, 6-10=-292/163, 4-10=-292/163 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG01 Truss Type Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458457 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-5HPdoRzER3jrTTWOi1ee17inC8sD02kuYUbjt8z5Pyh Scale = 1:105.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 24 23 22 21 20 19 18 17 16 1525262728293031323334353637383940 4x6 8x8 4x6 8x8 10x10 5x6 4x6 2x4 4x6 5x8 4x6 6x8 2x4 4x6 6x8 8x8 4x6 4x8 4x8 4x6 5x12 5x6 6-5-6 6-5-6 12-7-4 6-1-14 19-11-8 7-4-4 27-5-8 7-6-0 34-11-8 7-6-0 42-3-12 7-4-4 52-3-0 9-11-4 56-11-0 4-8-0 -1-2-8 1-2-8 6-5-6 6-5-6 12-7-4 6-1-14 19-11-8 7-4-4 27-5-8 7-6-0 34-11-8 7-6-0 42-3-12 7-4-4 47-3-6 4-11-10 52-3-0 4-11-10 56-11-0 4-8-0 58-1-8 1-2-8 0-10-1410-2-02-10-1410-4-50-6-1410-2-09.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-5-2,0-1-8], [2:0-1-0,0-0-12], [5:0-4-0,0-3-14], [10:0-4-0,0-3-14], [13:1-0-0,0-0-6], [15:0-3-8,0-2-0], [18:0-3-8,0-3-0], [21:0-3-8,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.93 0.74 0.91 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.40 -0.89 0.19 0.45 (loc) 18-20 18-20 13 18-20 l/defl >999 >768 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 780 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 3-24,3-23,11-17,11-15,12-15: 2x4 SPF-S Stud WEDGE Left: 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-7 oc purlins, except 2-0-0 oc purlins (4-9-5 max.): 5-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-18 REACTIONS.(lb/size)2=6337/0-3-8, 13=5126/0-3-8 Max Horz 2=-234(LC 11) Max Uplift 2=-2289(LC 4), 13=-1382(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-9349/3540, 3-5=-8470/3442, 5-6=-9010/3709, 6-7=-10018/3888, 7-9=-10018/3888, 9-10=-9282/3263, 10-11=-8272/2650, 11-12=-11004/3149, 12-13=-10199/2837 BOT CHORD 2-24=-2838/7126, 23-24=-2838/7126, 21-23=-2769/6705, 20-21=-3690/9007, 18-20=-3145/9280, 17-18=-1953/6571, 15-17=-2080/7168, 13-15=-2453/8918 WEBS 3-24=-220/914, 3-23=-534/185, 5-23=-797/1594, 5-21=-1675/3901, 6-21=-1910/554, 6-20=-412/1719, 7-20=-442/176, 9-20=-1164/1298, 9-18=-1574/1143, 10-18=-1983/4601, 10-17=-83/985, 11-17=-941/311, 11-15=-585/2636, 12-15=-1961/594 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=2289, 13=1382. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG01 Truss Type Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458457 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:42 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-5HPdoRzER3jrTTWOi1ee17inC8sD02kuYUbjt8z5Pyh NOTES- 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 462 lb down and 189 lb up at 4-8-0, 266 lb down and 76 lb up at 6-8-0, 266 lb down and 118 lb up at 8-8-0, 266 lb down and 175 lb up at 10-8-0, 266 lb down and 239 lb up at 12-8-0, 266 lb down and 239 lb up at 14-8-0, 266 lb down and 239 lb up at 16-8-0, 266 lb down and 239 lb up at 18-8-0, 266 lb down and 239 lb up at 20-8-0, 266 lb down and 239 lb up at 22-8-0, 266 lb down and 239 lb up at 24-8-0, 266 lb down and 239 lb up at 26-8-0, 266 lb down and 239 lb up at 28-8-0, 266 lb down and 239 lb up at 30-8-0, and 266 lb down and 239 lb up at 31-8-0, and 1755 lb down and 302 lb up at 33-0-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 5-10=-60, 10-12=-60, 12-14=-60, 2-23=-20, 23-29=-60, 21-29=-20, 21-33=-60, 33-35=-20, 18-35=-60, 18-38=-20, 17-38=-60, 17-39=-20, 39-40=-60, 13-40=-20 Concentrated Loads (lb) Vert: 24=-266 23=-266 19=-266 25=-462(F) 26=-266 27=-266 28=-266 29=-266 30=-266 31=-266 32=-266 33=-266 34=-266 35=-266 36=-266 37=-1755(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG02 Truss Type Half Hip Girder Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458458 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-5HPdoRzER3jrTTWOi1ee17ixc8z80COuYUbjt8z5Pyh Scale = 1:26.7 1 2 3 4 7 6 589 5x6 2x4 4x6 2x4 3x4 4x6 2-5-13 2-5-13 7-7-8 5-1-11 -1-2-8 1-2-8 2-5-13 2-5-13 7-7-8 5-1-11 1-5-94-2-74-4-54-2-714.00 12 Plate Offsets (X,Y)-- [3:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.26 0.30 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.04 0.00 0.02 (loc) 5-6 5-6 5 5-6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 42 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)5=482/Mechanical, 7=543/0-3-8 Max Horz 7=169(LC 5) Max Uplift 5=-173(LC 6), 7=-164(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-447/172, 2-7=-600/200 BOT CHORD 5-6=-131/255 WEBS 3-6=-181/277, 3-5=-294/159, 2-6=-133/330 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=173, 7=164. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 82 lb down and 119 lb up at 2-5-13, and 140 lb down and 76 lb up at 3-8-4, and 140 lb down and 76 lb up at 5-8-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=-78 8=-140 9=-140 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG03 Truss Type Half Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458459 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-ZTz?0n_sCNri5d5bFl9tZKF?7YAwlWe1m8LHQaz5Pyg Scale = 1:75.3 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 91718192021222324252627282930313233 6x6 3x6 5x8 3x12 3x12 4x8 8x8 5x6 3x4 2x4 4x8 3x6 5x8 5x6 3x6 4x8 2-7-4 2-7-4 11-1-7 8-6-3 19-9-6 8-7-15 28-5-5 8-7-15 37-3-0 8-9-11 2-7-4 2-7-4 11-1-7 8-6-3 19-9-6 8-7-15 28-5-5 8-7-15 37-3-0 8-9-11 8-4-1410-2-010-4-510-2-09.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-12], [10:0-3-8,0-2-8], [15:0-3-8,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.73 0.84 0.86 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.17 -0.36 0.04 0.25 (loc) 12-13 12-13 9 10-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 479 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-7-12 max.): 2-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9, 2-13, 8-10, 1-16 REACTIONS.(lb/size)9=3883/0-3-8, 16=4234/Mechanical Max Horz 16=53(LC 5) Max Uplift 9=-1932(LC 3), 16=-2175(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1317/694, 2-3=-3565/1950, 3-5=-4156/2285, 5-7=-4156/2285, 7-8=-3025/1624, 8-9=-3618/1917, 1-16=-4461/2336 BOT CHORD 13-15=-596/1091, 12-13=-1948/3563, 10-12=-1624/3025 WEBS 2-15=-2412/1256, 2-13=-2101/3788, 3-13=-1266/626, 3-12=-508/899, 5-12=-497/201, 7-12=-997/1706, 7-10=-1847/978, 8-10=-2439/4534, 1-15=-2044/3818 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=1932, 16=2175. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG03 Truss Type Half Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458459 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:43 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-ZTz?0n_sCNri5d5bFl9tZKF?7YAwlWe1m8LHQaz5Pyg NOTES- 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 271 lb down and 181 lb up at 1-9-12, 266 lb down and 239 lb up at 3-9-12, 266 lb down and 239 lb up at 5-9-12, 266 lb down and 239 lb up at 7-9-12, 266 lb down and 239 lb up at 9-9-12, 266 lb down and 239 lb up at 11-9-12, 266 lb down and 239 lb up at 13-9-12, 266 lb down and 239 lb up at 15-9-12, 273 lb down and 237 lb up at 17-9-12, 273 lb down and 237 lb up at 19-9-12, 273 lb down and 237 lb up at 21-9-12, 273 lb down and 237 lb up at 23-9-12, 273 lb down and 237 lb up at 25-9-12, 273 lb down and 237 lb up at 27-9-12, and 273 lb down and 237 lb up at 29-9-12, and 273 lb down and 237 lb up at 31-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-8=-60, 15-16=-20, 15-20=-60, 13-20=-20, 13-25=-60, 25-28=-20, 10-28=-60, 10-33=-20, 9-33=-60 Concentrated Loads (lb) Vert: 12=-273 17=-271(B) 18=-266 19=-266 20=-266 21=-266 22=-266 23=-266 24=-266 26=-273 27=-273 29=-273 30=-273 31=-273 32=-273 33=-273 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG04 Truss Type Half Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458460 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-1gXND6?VzgzZingnpSg66YoCDyZCU0sB?o4qy0z5Pyf Scale = 1:46.8 1 2 3 4 5 9 8 7 6 10 11 12 13 6x6 3x6 3x6 5x6 10x16 6x8 4x6 2x4 5-9-8 5-9-8 7-9-0 1-11-8 13-11-0 6-2-0 -1-2-8 1-2-8 5-9-8 5-9-8 7-9-0 1-11-8 13-11-0 6-2-0 1-5-98-0-128-2-108-0-1214.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-8], [3:0-3-12,0-2-8], [7:0-7-4,0-6-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.64 0.64 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.19 0.00 0.07 (loc) 6-7 6-7 6 6-7 l/defl >999 >850 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 223 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 5-6,5-7,3-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6 REACTIONS.(lb/size)6=7668/0-3-8, 9=3582/0-3-8 Max Horz 9=287(LC 5) Max Uplift 6=-1627(LC 6), 9=-1033(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3879/1187, 3-4=-3446/1058, 4-5=-3444/1058, 5-6=-4495/1384, 2-9=-3540/1062 BOT CHORD 8-9=-395/249, 7-8=-841/2461 WEBS 3-8=-1154/86, 5-7=-1697/5495, 2-8=-800/2267, 4-7=-330/163, 3-7=-1068/4029 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 7-4 2x4 - 1 row at 0-8-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=1627, 9=1033. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 4214 lb down and 2187 lb up at 7-9-0, 1936 lb down and 90 lb up at 9-2-12, and 1904 lb down and 151 lb up at 11-2-12, and 1906 lb down and 148 lb up at 13-2-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG04 Truss Type Half Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458460 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:44 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-1gXND6?VzgzZingnpSg66YoCDyZCU0sB?o4qy0z5Pyf LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-5=-60, 9-11=-20, 6-11=-60 Concentrated Loads (lb) Vert: 7=-4214(B) 10=-1936(B) 12=-1904(B) 13=-1906(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG05 Truss Type Half Hip Girder Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458461 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:45 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-Vs5mRS07k_5QKwFzNABLelKKaMvzDVIKESqOUSz5Pye Scale = 1:31.3 1 2 3 4 5 8 7 6 9 10 11 12 13 5x6 3x4 4x8 3x4 8x8 3x4 4x6 3-3-10 3-3-10 13-11-0 10-7-6 -1-2-8 1-2-8 3-3-10 3-3-10 8-5-9 5-1-15 13-11-0 5-5-7 1-5-95-1-145-3-125-1-1414.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.79 0.67 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.20 -0.56 0.01 0.28 (loc) 6-7 6-7 6 6-7 l/defl >819 >293 n/a >594 L/d 360 240 n/a 240 PLATES MT20 Weight: 78 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-12 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-6 REACTIONS.(lb/size)6=1196/0-3-8, 8=1151/0-3-8 Max Horz 8=198(LC 5) Max Uplift 6=-392(LC 3), 8=-320(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1386/450, 3-4=-838/314, 2-8=-1527/459 BOT CHORD 6-7=-227/644 WEBS 3-7=-286/799, 4-7=-160/312, 4-6=-808/287, 2-7=-338/978 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=392, 8=320. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 208 lb down and 157 lb up at 3-3-10, 193 lb down and 93 lb up at 4-8-12, 193 lb down and 93 lb up at 6-8-12, 193 lb down and 93 lb up at 8-8-12, and 193 lb down and 93 lb up at 10-8-12, and 193 lb down and 93 lb up at 12-8-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-5=-60, 6-8=-20 Concentrated Loads (lb) Vert: 7=-208 9=-193 10=-193 11=-193 12=-193 13=-193 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG06 Truss Type Roof Special Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458462 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-_2f8eo0lVIDHy4q9xtjaBzteWmKeyxYTT6Zx1vz5Pyd Scale = 1:46.3 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 16 2x4 3x8 5x6 4x6 5x6 2x4 3x8 3x8 3x8 3x8 4-5-4 4-5-4 8-0-0 3-6-12 11-6-12 3-6-12 16-0-0 4-5-4 4-5-4 4-5-4 8-0-0 3-6-12 11-6-12 3-6-12 16-0-0 4-5-4 3-1-107-3-83-1-1014.00 12 Plate Offsets (X,Y)-- [7:0-3-8,0-1-8], [9:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.20 0.26 0.60 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.10 0.01 0.01 (loc) 8 7-8 6 8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 169 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2, 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=1575/0-3-8, 6=1544/0-3-8 Max Horz 10=-101(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-1334/0, 1-2=-1869/0, 2-3=-1534/0, 3-4=-1534/0, 4-5=-1763/0, 5-6=-1267/0 BOT CHORD 8-9=0/1901, 7-8=0/1799 WEBS 1-9=0/2190, 2-9=-618/0, 2-8=-1190/0, 3-8=0/1976, 4-8=-1062/0, 4-7=-696/0, 5-7=0/2068 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 273 lb down at 1-8-12, 273 lb down at 3-8-12, 273 lb down at 5-8-12, 273 lb down at 7-8-12, 273 lb down at 9-8-12, 163 lb down at 11-8-12, and 163 lb down at 13-8-12, and 169 lb down at 15-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-5=-60, 6-10=-20 Continued on page 2 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG06 Truss Type Roof Special Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458462 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:46 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-_2f8eo0lVIDHy4q9xtjaBzteWmKeyxYTT6Zx1vz5Pyd LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 8=-273(B) 7=-163(B) 11=-273(B) 12=-273(B) 13=-273(B) 14=-273(B) 15=-163(B) 16=-169(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG07 Truss Type Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458463 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-_2f8eo0lVIDHy4q9xtjaBztcYmIxy_2TT6Zx1vz5Pyd Scale = 1:40.2 1 2 3 4 5 6 12 11 10 9 8 7 13 14 15 16 17 18 19 20 3x6 6x6 6x6 2x4 4x6 3x8 2x4 3x8 2x4 3x6 3x8 3-4-9 3-4-9 10-9-8 7-4-15 18-2-7 7-4-15 21-7-0 3-4-9 3-4-9 3-4-9 10-9-8 7-4-15 18-2-7 7-4-15 21-7-0 3-4-9 22-9-8 1-2-8 2-6-116-4-26-6-02-6-116-4-214.00 12 Plate Offsets (X,Y)-- [2:0-3-15,0-3-0], [4:0-3-15,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.33 0.43 0.44 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.11 0.02 0.06 (loc) 8-9 8-9 7 9-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 236 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-11,3-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)12=1776/0-3-8, 7=1863/0-3-8 Max Horz 12=-192(LC 11) Max Uplift 12=-820(LC 4), 7=-821(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1487/754, 2-3=-931/516, 3-4=-924/519, 4-5=-1499/764, 1-12=-1859/882, 5-7=-1947/884 BOT CHORD 9-11=-888/1924, 8-9=-888/1924 WEBS 2-11=-473/816, 3-11=-1284/527, 3-9=-381/1054, 3-8=-1290/522, 4-8=-490/817, 1-11=-613/1172, 5-8=-605/1178 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=820, 7=821. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 197 lb down and 349 lb up at 3-4-9, 199 lb down and 132 lb up at 4-9-8, 170 lb down and 114 lb up at 6-9-8, 170 lb down and 114 lb up at 8-9-8, 170 lb down and 114 lb up at 10-9-8, 170 lb down and 114 lb up at 12-9-8, 170 lb down and 114 lb up at 14-9-8, and 199 lb down and 132 lb up at 16-9-8, and 197 lb down and 349 lb up at 18-2-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG07 Truss Type Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458463 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:46 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-_2f8eo0lVIDHy4q9xtjaBztcYmIxy_2TT6Zx1vz5Pyd LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-5=-60, 5-6=-60, 12-15=-20, 15-18=-60, 7-18=-20 Concentrated Loads (lb) Vert: 11=-197 9=-170 8=-197 13=-199 14=-170 16=-170 17=-170 19=-170 20=-199 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG08 Truss Type Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458464 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-SFDWs81NFbL8ZEPMUbEpkAQjA9W?hPhdhmJUZLz5Pyc Scale = 1:55.6 1 2 3 4 5 6 11 10 9 8 7121314151617181920 5x6 5x6 6x6 3x4 4x6 6x8 3x4 3x4 4x6 10x10 6-2-15 6-2-15 15-4-1 9-1-1 21-7-0 6-2-15 6-2-15 6-2-15 10-9-8 4-6-9 15-4-1 4-6-9 21-7-0 6-2-15 22-9-8 1-2-8 2-6-119-8-49-10-22-6-119-8-414.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [4:0-3-12,0-2-8], [5:0-2-12,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.59 0.96 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.17 -0.37 0.01 0.10 (loc) 8-10 8-10 7 7-8 l/defl >999 >690 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 274 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E *Except* 7-9: 2x6 SPF No.2 WEBS 2x4 SPF No.2 *Except* 1-11,1-10,5-7,5-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)11=3438/0-3-8, 7=3783/0-3-8 Max Horz 11=-273(LC 3) Max Uplift 7=-550(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3037/0, 2-3=-1865/0, 3-4=-1949/100, 4-5=-3181/28, 1-11=-3070/0, 5-7=-3281/0 BOT CHORD 10-11=-237/282, 8-10=0/1980 WEBS 2-10=0/1950, 3-10=-315/422, 3-8=-289/100, 4-8=0/2062, 1-10=0/1940, 5-8=0/1980 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=550. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 471 lb down at 1-6-4, 471 lb down at 3-6-4, 471 lb down at 5-6-4, 465 lb down at 7-6-4, 445 lb down at 9-6-4, 445 lb down at 11-6-4, 524 lb down at 13-6-4, 497 lb down and 46 lb up at 15-6-4, and 759 lb down and 67 lb up at 17-6-4, and 674 lb down and 800 lb up at 19-6-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG08 Truss Type Hip Girder Qty 1 Ply 2 Wedgewood 23 Gray Oaks Job Reference (optional) I37458464 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:47 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-SFDWs81NFbL8ZEPMUbEpkAQjA9W?hPhdhmJUZLz5Pyc LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-5=-60, 5-6=-60, 11-15=-20, 15-18=-60, 7-18=-20 Concentrated Loads (lb) Vert: 9=-465(B) 8=-497(B) 12=-471(B) 13=-471(B) 14=-471(B) 16=-445(B) 17=-445(B) 18=-524(B) 19=-759(B) 20=-674(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss TG09 Truss Type Flat Girder Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458465 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:48 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-wRmu3U2?0vT?BO_Y2Il2GOysRZ_9QvkmwQ225nz5Pyb Scale = 1:31.6 1 2 3 4 7 6 5 8 9 10 11 12 13 14 3x4 3x8 3x4 6x16 3x4 3x12 2x4 3x4 7-11-8 7-11-8 16-2-8 8-3-0 7-11-8 7-11-8 16-2-8 8-3-0 4-8-61-1-24-8-6LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.75 0.39 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.09 -0.01 0.18 (loc) 6-7 6-7 9 6-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-6,4-6: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD 2-0-0 oc purlins (5-8-9 max.): 1-4, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-6, 4-6 REACTIONS.(lb/size)7=694/Mechanical, 9=653/0-3-0 Max Uplift 7=-788(LC 3), 9=-578(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-7=-602/555, 1-2=-766/912, 2-4=-766/912 WEBS 1-6=-1013/840, 2-6=-544/174, 4-6=-969/773, 4-9=-657/580 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=788, 9=578. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 34 lb down and 210 lb up at 1-9-12, 34 lb down and 210 lb up at 3-9-12, 34 lb down and 210 lb up at 5-9-12, 34 lb down and 210 lb up at 7-9-12, and 34 lb down and 210 lb up at 9-9-12, and 34 lb down and 210 lb up at 11-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=-16 10=-16 11=-16 12=-16 13=-16 14=-16 June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V01 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458466 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-OdKGHq3dnDcspYZkc?GHpbV71zNK9NXw93obdEz5Pya Scale = 1:50.6 1 2 3 4 5 6 11 10 9 8 7123x4 4x6 6x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-3 0-0-3 9-9-9 9-9-5 14-7-3 4-9-11 6-9-3 6-9-3 9-9-9 3-0-5 14-7-3 4-9-11 0-0-44-2-77-10-124-2-714.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.38 0.20 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-3: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-7-0. (lb) - Max Horz 1=166(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 10, 8, 9 except 11=-196(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 9 except 10=425(LC 1), 11=367(LC 10), 8=408(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 10, 8, 9 except (jt=lb) 11=196. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V02 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458467 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-OdKGHq3dnDcspYZkc?GHpbV74zNJ9PRw93obdEz5Pya Scale = 1:39.8 1 2 3 4 5 6 11 10 9 8 73x4 4x6 6x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-3 0-0-3 7-2-11 7-2-7 13-3-12 6-1-1 5-5-12 5-5-12 7-2-11 1-8-15 13-3-12 6-1-1 0-0-44-2-76-4-124-2-714.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.38 0.20 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-3: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-3-9. (lb) - Max Horz 1=141(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 10, 8, 9 except 11=-197(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 10, 9 except 11=311(LC 10), 8=456(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-11=-247/262 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 10, 8, 9 except (jt=lb) 11=197. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V03 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458468 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-squeUA4FYWkjQi7xAjnWLp1KUNkkutA3NjX9Agz5PyZ Scale = 1:25.5 1 2 3 4 5 8 7 63x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 12-0-5 12-0-5 3-8-14 3-8-14 12-0-5 8-3-8 0-0-44-2-74-4-54-2-714.00 12 Plate Offsets (X,Y)-- [2:0-2-3,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.21 0.19 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 2-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-0-2. (lb) - Max Horz 1=121(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 6, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 7=549(LC 11), 8=400(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-7=-277/123 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7, 8. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V04 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458469 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-squeUA4FYWkjQi7xAjnWLp1HpNjCutM3NjX9Agz5PyZ Scale = 1:25.5 1 2 3 4 7 6 53x4 6x6 2x4 2x4 2x4 2x4 2x4 10-8-15 10-8-15 3-8-14 3-8-14 10-8-15 7-0-1 0-0-44-2-74-4-54-2-714.00 12 Plate Offsets (X,Y)-- [2:0-3-15,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.22 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-8-11. (lb) - Max Horz 1=121(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=493(LC 11), 7=304(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V05 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458470 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-K0S1hW4uJqsZ2ri7jQIlu0aSGn3udKmCcNHii6z5PyY Scale = 1:26.4 1 2 3 4 7 6 53x4 5x6 2x4 2x4 2x4 2x4 2x4 9-5-8 9-5-8 3-8-14 3-8-14 9-5-8 5-8-10 0-0-44-2-74-4-54-2-714.00 12 Plate Offsets (X,Y)-- [2:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.40 0.19 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 9-5-4. (lb) - Max Horz 1=121(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 5, 6 except 7=-113(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 6=407(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6 except (jt=lb) 7=113. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V06 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458471 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-K0S1hW4uJqsZ2ri7jQIlu0aRMn3hdKXCcNHii6z5PyY Scale = 1:26.3 1 2 3 4 6 53x4 3x4 2x4 2x4 2x4 2x4 8-2-1 8-2-1 3-8-14 3-8-14 8-2-1 4-5-3 0-0-44-2-74-4-54-2-714.00 12 Plate Offsets (X,Y)-- [2:0-2-3,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.45 0.21 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=119/8-1-13, 5=199/8-1-13, 6=457/8-1-13 Max Horz 1=121(LC 6) Max Uplift 5=-33(LC 4), 6=-89(LC 6) Max Grav 1=119(LC 1), 5=210(LC 11), 6=457(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-258/209 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V07 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458472 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-oC0Pvs5W48_Qg?HJH8p_RE7exAOnMn9Mr10FEZz5PyX Scale = 1:26.3 1 2 3 5 43x4 5x6 2x4 2x4 2x4 6-10-10 6-10-10 3-8-14 3-8-14 6-10-10 3-1-12 0-0-44-2-74-4-54-2-714.00 12 Plate Offsets (X,Y)-- [2:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.27 0.28 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-10-10 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)1=107/6-10-7, 4=162/6-10-7, 5=373/6-10-7 Max Horz 1=121(LC 6) Max Uplift 4=-27(LC 4), 5=-95(LC 6) Max Grav 1=107(LC 1), 4=170(LC 11), 5=373(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V08 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458473 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-oC0Pvs5W48_Qg?HJH8p_RE7fkAP2MnJMr10FEZz5PyX Scale = 1:26.5 1 2 3 4 6 53x4 5x6 3x4 2x4 2x4 2x4 5-7-3 5-7-3 3-8-14 3-8-14 5-1-13 1-4-15 5-7-3 0-5-7 0-0-44-2-74-4-53-10-04-2-714.00 12 Plate Offsets (X,Y)-- [2:0-3-9,0-2-8], [3:0-2-3,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.22 0.20 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-3 oc purlins, except end verticals, and 2-0-0 oc purlins: 2-3. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)1=112/5-7-0, 5=38/5-7-0, 6=265/5-7-0 Max Horz 1=114(LC 6) Max Uplift 5=-21(LC 4), 6=-100(LC 6) Max Grav 1=112(LC 1), 5=54(LC 11), 6=265(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V09 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458474 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-GPan6B68rR6HI9sWrrLDzRfp2al45E5V4hmpm?z5PyW Scale = 1:21.4 1 2 3 5 4 2x4 4x6 2x4 2x4 2x4 4-3-12 4-3-12 3-1-14 3-1-14 4-3-12 1-1-14 0-0-43-8-32-4-014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.31 0.15 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)1=108/4-3-9, 4=27/4-3-9, 5=176/4-3-9 Max Horz 1=76(LC 6) Max Uplift 1=-3(LC 7), 4=-35(LC 7), 5=-16(LC 5) Max Grav 1=108(LC 10), 4=27(LC 1), 5=176(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V10 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458475 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-lb89KX7mclE8vJRiPZsSWfC19_7vqhefILVMJRz5PyV Scale = 1:13.8 1 2 3 5 4 2x4 4x6 3x8 2x4 3-0-5 3-0-5 1-10-7 1-10-7 3-0-5 1-1-14 0-0-42-2-30-10-014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14], [3:0-1-7,0-1-4], [4:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.10 0.04 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)1=59/3-0-2, 4=37/3-0-2, 5=113/3-0-2 Max Horz 1=42(LC 5) Max Uplift 1=-21(LC 7), 4=-28(LC 7), 5=-8(LC 5) Max Grav 1=59(LC 10), 4=37(LC 1), 5=113(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V11 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458476 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-lb89KX7mclE8vJRiPZsSWfCxh_5cqesfILVMJRz5PyV Scale = 1:37.7 1 2 3 4 5 9 8 7 63x4 6x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-3 0-0-3 5-5-7 5-5-3 11-4-9 5-11-2 5-5-7 5-5-7 11-4-9 5-11-2 0-0-46-2-76-4-56-2-714.00 12 Plate Offsets (X,Y)-- [3:0-3-15,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.51 0.19 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-4-5. (lb) - Max Horz 1=183(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 7 except 9=-207(LC 6), 8=-103(LC 6) Max Grav All reactions 250 lb or less at joint(s) 6, 8 except 1=260(LC 6), 7=410(LC 11), 9=335(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-361/92 WEBS 2-9=-263/294 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 7 except (jt=lb) 9=207, 8=103. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V12 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458477 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-DnhXXt7ON3M?XT0uyGNh2sl6wOQDZ52oX?Fwrtz5PyU Scale = 1:37.5 1 2 3 4 5 9 8 7 62x4 5x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 10-1-2 10-1-2 5-5-7 5-5-7 9-4-13 3-11-6 10-1-2 0-8-5 0-0-46-2-76-4-55-6-106-2-714.00 12 Plate Offsets (X,Y)-- [3:0-3-9,0-2-8], [4:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.48 0.23 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 8-9. REACTIONS.All bearings 10-0-14. (lb) - Max Horz 1=170(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 8 except 6=-228(LC 10), 9=-215(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1 except 7=520(LC 11), 8=410(LC 10), 9=285(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-337/92 WEBS 2-9=-253/300 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 8 except (jt=lb) 6=228, 9=215. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V13 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458478 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-DnhXXt7ON3M?XT0uyGNh2sl6WOS2Z6ooX?Fwrtz5PyU Scale = 1:38.3 1 2 3 4 5 9 8 7 62x4 5x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 0-0-3 0-0-3 5-5-7 5-5-3 8-9-11 3-4-4 5-5-7 5-5-7 6-9-15 1-4-8 8-9-11 1-11-12 0-0-46-2-76-4-54-0-106-2-714.00 12 Plate Offsets (X,Y)-- [3:0-3-9,0-2-8], [4:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.51 0.11 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 8-9-7. (lb) - Max Horz 1=137(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 6, 7, 8 except 1=-107(LC 4), 9=-206(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 6, 7, 8 except 9=322(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-265/131 WEBS 2-9=-260/310 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7, 8 except (jt=lb) 1=107, 9=206. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V14 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458479 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-h_FwlD808MUs9db4W_uwb4HIuokIIZzymf_TNKz5PyT Scale = 1:38.7 1 2 3 5 43x4 4x6 2x4 2x4 2x4 7-6-4 7-6-4 4-10-4 4-10-4 7-6-4 2-8-0 0-0-45-7-152-6-1014.00 12 Plate Offsets (X,Y)-- [1:0-0-15,0-1-8], [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.40 0.37 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)1=162/7-6-0, 4=69/7-6-0, 5=337/7-6-0 Max Horz 1=120(LC 5) Max Uplift 1=-32(LC 7), 4=-57(LC 7), 5=-55(LC 5) Max Grav 1=162(LC 1), 4=88(LC 11), 5=337(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V15 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458480 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-h_FwlD808MUs9db4W_uwb4HLwommIbeymf_TNKz5PyT Scale = 1:28.8 1 2 3 5 43x4 4x6 2x4 2x4 2x4 6-2-13 6-2-13 3-6-13 3-6-13 6-2-13 2-8-0 0-0-44-1-151-0-1014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.21 0.21 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=140/6-2-10, 4=116/6-2-10, 5=209/6-2-10 Max Horz 1=89(LC 5) Max Uplift 1=-53(LC 7), 4=-58(LC 7), 5=-30(LC 5) Max Grav 1=140(LC 1), 4=122(LC 11), 5=209(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V16 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458481 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-9ApIyZ9evgcjmmAH4hP98HqT_B5E12x5_Jk0vmz5PyS Scale = 1:28.9 1 2 3 5 42x4 2x4 2x4 2x4 2x4 6-7-9 6-7-9 0-0-44-11-119.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.26 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=43/6-7-4, 4=131/6-7-4, 5=313/6-7-4 Max Horz 1=141(LC 6) Max Uplift 4=-40(LC 6), 5=-94(LC 6) Max Grav 1=92(LC 6), 4=131(LC 1), 5=313(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V17 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458482 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-9ApIyZ9evgcjmmAH4hP98HqUZB6?12c5_Jk0vmz5PyS Scale: 3/4"=1' 1 2 3 2x4 2x4 2x4 3-6-4 3-6-4 0-0-42-7-119.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.34 0.21 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=119/3-5-15, 3=119/3-5-15 Max Horz 1=69(LC 6) Max Uplift 3=-36(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V18 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458483 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-dMNg9vAHg_kaOwlTeOwOgVNVdbMImVsEDzTaSCz5PyR Scale: 1/2"=1' 1 2 32x4 2x4 2x4 5-6-6 5-6-6 0-0-44-1-129.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.96 0.59 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=200/5-6-0, 3=200/5-6-0 Max Horz 1=115(LC 6) Max Uplift 3=-60(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V19 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458484 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-dMNg9vAHg_kaOwlTeOwOgVNiYbUDmVsEDzTaSCz5PyR Scale: 1"=1' 1 2 3 2x4 2x4 2x4 2-5-0 2-5-0 0-0-41-9-129.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.14 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=75/2-4-11, 3=75/2-4-11 Max Horz 1=43(LC 6) Max Uplift 3=-23(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V20 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458485 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:59 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-5Yx2NFAvRHsR04KfB6ReDivtJ?pSVyvOSdD7_fz5PyQ Scale = 1:15.4 1 2 3 4 2x4 4x6 2x4 2x4 0-0-3 0-0-3 4-3-13 4-3-10 2-1-14 2-1-14 4-3-13 2-1-15 0-0-42-6-40-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.13 0.08 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=92/4-3-6, 3=92/4-3-6, 4=112/4-3-6 Max Horz 1=-52(LC 4) Max Uplift 1=-17(LC 7), 3=-14(LC 6) Max Grav 1=92(LC 1), 3=92(LC 1), 4=114(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V21 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458486 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:46:59 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-5Yx2NFAvRHsR04KfB6ReDivvA?qGVy6OSdD7_fz5PyQ Scale = 1:7.9 1 2 3 2x4 3x4 2x4 0-0-3 0-0-3 1-8-15 1-8-12 0-10-8 0-10-8 1-8-15 0-10-8 0-0-41-0-40-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.02 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-8-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=44/1-8-8, 3=44/1-8-8 Max Horz 1=-16(LC 4) Max Uplift 1=-2(LC 7), 3=-2(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V22 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458487 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-ZlVQabBXCb_IdEuslpztlwS1mP8nEN0XhHygW5z5PyP Scale = 1:37.1 1 2 3 4 5 9 8 7 610113x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-1-14 14-1-14 7-9-14 7-9-14 14-1-14 6-4-0 0-0-45-10-71-1-79.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.22 0.14 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 44 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-1-9. (lb) - Max Horz 1=126(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-110(LC 6), 7=-106(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=430(LC 1), 9=369(LC 10), 7=324(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-262/154 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=110, 7=106. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V23 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458488 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:01 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-1x3powC9yv69FOT2JXU6I7?AQpTizsjhvxiE2Xz5PyO Scale = 1:23.7 1 2 3 43x6 4x6 3x6 2x4 9-4-12 9-4-12 9-5-2 0-0-5 4-8-9 4-8-9 9-5-2 4-8-9 0-0-43-6-70-0-49.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.35 0.23 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=175/9-4-7, 3=175/9-4-7, 4=335/9-4-7 Max Horz 1=-75(LC 4) Max Uplift 1=-18(LC 6), 3=-22(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V24 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458489 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:01 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-1x3powC9yv69FOT2JXU6I7?F5pU5zschvxiE2Xz5PyO Scale = 1:8.8 1 2 3 2x4 3x4 2x4 0-0-5 0-0-5 3-2-7 3-2-2 1-7-3 1-7-3 3-2-7 1-7-3 0-0-41-2-70-0-49.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.05 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=93/3-1-12, 3=93/3-1-12 Max Horz 1=-20(LC 4) Max Uplift 1=-4(LC 6), 3=-4(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V25 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458490 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-W7dB?GDnjCE0tY2EtE?LrLXN3CnjiIhq8bRnbzz5PyN Scale = 1:47.3 1 2 3 5 462x4 2x4 2x4 2x4 2x4 6-10-4 6-10-4 0-0-48-0-014.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.23 0.37 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=47/6-10-1, 4=195/6-10-1, 5=398/6-10-1 Max Horz 1=232(LC 6) Max Uplift 1=-8(LC 4), 4=-79(LC 6), 5=-197(LC 6) Max Grav 1=232(LC 6), 4=195(LC 1), 5=398(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-381/74 WEBS 2-5=-239/308 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=197. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V26 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458491 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-W7dB?GDnjCE0tY2EtE?LrLXNnCo3iIcq8bRnbzz5PyN Scale = 1:38.7 1 2 3 5 42x4 2x4 2x4 2x4 2x4 5-6-14 5-6-14 0-0-46-6-014.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.25 0.28 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=-43/5-6-10, 4=126/5-6-10, 5=329/5-6-10 Max Horz 1=185(LC 6) Max Uplift 1=-44(LC 4), 4=-77(LC 6), 5=-200(LC 6) Max Grav 1=241(LC 6), 4=126(LC 1), 5=329(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-385/80 WEBS 2-5=-246/324 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=200. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V27 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458492 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-_KAZDcEPUWMsUhdRQyWaNY4SPc79Rm5_NFBL7Qz5PyM Scale = 1:28.1 1 2 32x4 2x4 2x4 4-3-7 4-3-7 0-0-45-0-014.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.58 0.35 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=155/4-3-3, 3=154/4-3-3 Max Horz 1=139(LC 6) Max Uplift 3=-94(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V28 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458493 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-_KAZDcEPUWMsUhdRQyWaNY4XPcAERm5_NFBL7Qz5PyM Scale = 1:20.6 1 2 3 2x4 2x4 2x4 3-0-0 3-0-0 0-0-43-6-014.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.26 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=103/2-11-12, 3=103/2-11-12 Max Horz 1=93(LC 6) Max Uplift 3=-63(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V29 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458494 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-SWkxQyE1FqUj6rCd_f1pwmdja0UnADd7bvwufsz5PyL Scale = 1:30.2 1 2 3 5 42x4 2x4 2x4 2x4 2x4 6-11-6 6-11-6 0-0-45-2-99.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.23 0.27 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=59/6-11-1, 4=129/6-11-1, 5=324/6-11-1 Max Horz 1=148(LC 6) Max Uplift 4=-39(LC 6), 5=-98(LC 6) Max Grav 1=93(LC 6), 4=129(LC 1), 5=324(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V30 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458495 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-SWkxQyE1FqUj6rCd_f1pwmdgb0UvADL7bvwufsz5PyL Scale = 1:17.3 1 2 3 2x4 2x4 2x4 3-10-1 3-10-1 0-0-42-10-99.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.42 0.26 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=132/3-9-11, 3=132/3-9-11 Max Horz 1=76(LC 6) Max Uplift 3=-40(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V31 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458496 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-wiIJdIFg07dak?npYNY2Sz9sXQqrvgbGqZgRCIz5PyK Scale = 1:23.0 1 2 32x4 2x4 2x4 3-4-15 3-4-15 0-0-43-11-1214.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.34 0.21 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=120/3-4-12, 3=119/3-4-12 Max Horz 1=107(LC 6) Max Uplift 3=-73(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901802 Truss V32 Truss Type Valley Qty 1 Ply 1 Wedgewood 23 Gray Oaks Job Reference (optional) I37458497 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Jun 17 09:47:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:jmfOjOBalde9RrhTRD3VlFz6M39-wiIJdIFg07dak?npYNY2Sz9wAQs4vgbGqZgRCIz5PyK Scale = 1:15.4 1 2 3 2x4 2x4 2x4 2-1-8 2-1-8 0-0-42-5-1214.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.11 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=68/2-1-5, 3=68/2-1-5 Max Horz 1=61(LC 6) Max Uplift 3=-41(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 17,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths