Loading...
HomeMy WebLinkAboutS101.0F6BCB3 3DB21SB36 B27B24DW B30 B30 B30 B27 F6B21TRASHU302496 W362424W4542 W2742W2742 W3042 W2430 606820682840 28402668AA BB CC DD EE F3 F3EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING DD CABINET ELEVATION SCALE 1/2" = 1'0"Zhiss ResidenceKitchen Remodel12499 Shadow Cove WayCarmel, IN 46033Date:Revision: 2 SHEET OF 7 SIGNATURE / SEALDESIGNER: TYLER VARGO E: tylerv@customlivingusa.com C: 574.274.4155Client Initials: Date: The plans, including all text, drawings, concepts and ideas, forming a part of the plans, and the selection and arrangement thereof Copright 2018 by Custom Living, Inc., Indianapolis IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans, or their content, without the prior written permission of Custom Living. Inc is strictly prohibited. PROPOSED FLOOR PLAN SCALE: 1/2" = 1' CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462206/27/2019 DATE: GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specifed on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be a Change Order during construction Owner understands that the Drywall Allowance is based on an estimated board count and square footage take-off. A final walk through with drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall install and finish budgets. Final drywall touchups will follow countertop installation. FRAMING PLAN NOTES Ceiling HT: 8'10" Existing ceiling joist location in relation to the proposed hood vent to be reviewed following demo. Ceiling joist may need to be headered off depending on intersection with necessary HVAC vent. Install exterior penetration vent with plinthe block for proposed Hood vent following HVAC rough ins INSULATION PLAN NOTES Foam and fire caulk all exposed and accessible mechanical penetrations per Municipal Building Code. Installation of new wall or ceiling insulation not included in current scope of work Scope to be verified following demolition phase DRYWALL PLAN NOTES Install drywall on necessary walls and ceilings following mechanical rough ins Interior Walls-Level 4 Finish (Smooth) Install drywall on kitchen ceiling following mechanical rough ins Interior Ceilings- Level 4 Finish (Smooth) Patch areas following demolition, framing and mechanical rough-ins Include a final drywall patch following countertop and backsplash installation AA CABINET ELEVATION SCALE 1/2" = 1'0" BB CABINET ELEVATION SCALE 1/2" = 1'0" CC CABINET ELEVATION SCALE 1/2" = 1'0" ** PRINTS TO SCALE IF PRINTED ON 24" X 36" ** EE CABINET ELEVATION SCALE 1/2" = 1'0" 07/11/19 Adam Schriner