Loading...
HomeMy WebLinkAbout19060179 State ReleaseELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/2 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on:June 17, 2019 Project number Release date 408430 06/10/19 Construction type Occupancy classification Scope of release II-B, SPK A-2, REM Type of release Project name Street address City County ARCH ELEC FDN HOOD MECH PLUM STR Standard Savor Restaurant 211 W. Main St Suite 102 CARMEL HAMILTON To: Owner / Architect / Engineer Jack - Morgan Jack Philip P Morgan AR00033266 7062 N. Tuxedo Street Indianapolis IN 46220 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: 4G0412AE 4G0603AF 14B0707310B 14B07037 14M050709 9E11026A This project has been reviewed under the 2014 Indiana Building Code, 2014 Indiana Fire Code, 2009 Indiana Electrical Code, 2012 Indiana Plumbing Code, 2014 Indiana Mechanical Code, 2014 Indiana Fuel Gas Code, 2010 Indiana Accessibility Chapter 11 (ICC A117.1 2009), and the 2010 Indiana Energy Conservation Code (ASHRAE 90.1 2007) The proposed building, addition, or remodel shall not put the existing building in noncompliance or into further noncompliance in accordance with 675 IAC 12-4-12. Detailed plans and specifications for the revised fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6- 3(a), 675 IAC 12-6- 7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13) One or more fire barriers or horizontal assemblies are being provided for the purpose of separating mixed occupancies into different fire areas in accordance with Section 707.3.10, IBC (675 IAC 13- 2.6). Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or stenciling. Such identification shall: 1. Be located in accessible concealed floor, floor-ceiling or attic spaces; 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in height with a minimum 3/8 inch stroke in a contrasting color incorporating the suggested wording, "FIRE WALL or FIRE BARRIER PROTECT ALL OPENINGS" or similar wording in accordance with Section 703.7, IBC (675 IAC 13-2.6). The complete installation of the kitchen exhaust hood and hood suppression system shall be in accordance with Sections 507 and 509, IMC (675 IAC 18-1.6). Access and working space shall be provided and maintained about all electric equipment in accordance with Section 110.26, IEC (675 IAC 17-1.8). Buildings shall be addressed as set forth in section 501.2 IBC (675 IAC 13-2.6) Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 3170000000, morwalsoplad1@gmail.com ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/2 AREL Penetrations in Rated Assemblies shall be effectively protected as set forth in section 714 IBC (675 IAC 13-2.6) Interior wall and ceiling decorative components shall be as set forth in Chapter 7 & Chapter 8 IBC (675 IAC 13-2.6) and ASTM C 635 & C 636 Smoke detectors shall be installed in accordance with Section 907 IBC (675 IAC 13-2.6) and manufactures installation instructions Occupancy Load Signage shall be posted in accordance with Section 1004.3 IBC (675 IAC 13-2.6) Panic Hardware shall be installed on egress doors in an “A” , “E” and/or “H” occupancies with 50 or more persons in accordance with Section 1008.1.10 IBC (675 IAC 13-2.6) Where public or common use parking is provided, accessible parking spaces shall be provided in accordance with IC-5-16-9 and Section 1106.1 IBC (675 IAC 13-2.6) Handicapped seating shall be provided in accordance with Section 802 ANSI A117.1 and Chapter 11 IBC (675 IAC 13-2.6) Gas fired appliances on wheels in Commercial Kitchens shall be installed as set forth in section 411.1.4 IFGC (675 IAC 25-3) (Quick Disconnects and Tethered) Type I Kitchen Hoods shall be tested prior to occupancy as set forth in section 507.16 IMC (675 IAC 18-1.6) Fire Hydrants shall be provided as set forth in section 507.1 IFC (675 IAC 22-2.5) Fire Extinguisher travel distance shall be in accordance with Section 906.2 IFC (675 IAC 22-2.5) and NFPA 10. All Commercial Kitchen receptacles shall be Ground-Fault Circuit Interrupter protected in accordance with Section 210.8 [B] IEC (675 IAC 17-1.8) A GFCI protected receptacle shall be located within twenty-five (25) feet of Heating/Cooling Equipment in accordance with Section 210.63 and 210.8 (b) IEC (675 IAC 17-1.8) Bonding shall be as set forth in section 250.104 (A) (B) & (C) IEC (675 IAC 17-1.8) Neon Lighting/Signs shall be installed as set forth in section 600.41 IEC (675 IAC 17-1.8) Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above - stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Code review official Address (name,title of local official,street,city,state and ZIP code REX MAYS JIM BLANCHARD ONE CIVIC SQUARE CARMEL,IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov Director, Division of Fire and Building Safety rmays@dhs.in.gov