HomeMy WebLinkAboutGN 100.1 - TITLE SHEETSavor Restaurant -Carmel
2.21 e5i I Street _ SAie 10:2 Art5 1 e5ien Di5tril Carmel, IN 46032
APPLICABLE CODES:
INDIANA BUILDING GODE - 2014 EDITION (2012 IBC IST EDITION)
INDIANA PLUMBING GODE - 2012 EDITION
INDIANA ELEGTRIGAL CODE - 200cl
INDIANA MEGHANIGAL GODE - 2014 EDITION (2012 IMG 15T EDITION)
INDIANA ENERGY CONSERVATION CODE 2010 EDITION (A5HRAE aO.0
INDIANA FIRE GODE - 2014 EDITION (IFG 2012 IST EDITION)
INDIANA FUEL 6A5 CODE - 2014 EDITION (IF6G 2012 IST EDITION)
ANSI I1-7.1 - 200N
CONTACT INFORMATION:
John Bennett
JT Designers, Inc.
555 5. Arlington Ave, Ste 105
Indianapolis, -IN 46219
317-826-1166
jtdesignersinc� gma i Lcom
PROJECT. SAVOR RESTAURANT
LOCATION: Moron $ Moir Street
Carmel, IN
PRIMARY OCCUPANCY
CLASSIFICATION: A2 - RESTAURANT (PER SECTION 505)
OCCUPANCY LOAD: 150 DESIGNED SEATING (INTERIOR)
II STAFF
CONSTRUCTION
TYPE: TYPE II-B Sprinkled- CONSTRUCTION
FIRE SUPPRESSION: FIRE EXTINGUISHERS / FIRE 5UFFRE55ION
BUILDING PROPERTIES
AREA (GROSS): +/- 5520 5F LEASE AREA/ 5654 5F NET AREA
HEIGHT: 10'-O" - INSIDE CLEAR / I4'-O" - EXTERIOR FACADE
HEIGHT ALLOWABLE: 55'-0"(PER TABLE 505)
FIRE PROTECTION REOUIREMENT5
TABLE 601
FOR TYPE III-B
STRUGTURAL FRAME
O HOUR
INCLUDING COLUMNS, GIRDERS, TRUSSES
BEARING WALLS
EXTERIOR
O HOUR
INTERIOR
O HOUR
NONBEARIN6 HALLS AND PARTITIONS
INTERIOR
O HOUR
FLOOR CONSTRUCTION
INCLUDING SUPPORTING AND JOISTS
O HOUR
SHAFTS
O HOUR
ROOF CONSTRUCTION
INCLUDING SUPPORTING
O HOUR
y7J dill; 1iiiiWN ]04r�roJt
TYPE III-B
EXTERIOR NONBEARIN6 HALLS < 5' - I HR. AND NO OPENING PERMITTED
>- 5' -< 10, - I HR. AND 10% OPENING LE55 THAN 10'
2 10, S 30' - O HOUR
130, - O HOUR
EXIT CORRIDOR I HOUR (PER TABLE 10043.2.1)
EGRESS DEMAND SEG 1003.2.2.1 AND 1003.2.2.2
EDUGATIONAL
CLASSROOM AREA 20 50. FT. NET PER PERSON
ASSEMBLY WITHOUT FIXED SEATS
CONCENTRATED -750. FT. NET PER PERSON
UNCONGENTRATED 15 50. FT. NET PER PERSON
PLATFORM 15 50. FT. NET PER PERSON
KITCHEN 200 50. FT. GRO55 PER PERSON
AGGESSORY STORAr 300 50. FT. GRO55 PER PERSON
RELEASED FOR CONSTRUCTION- 300 50. FT. OR055 PER PERSON
0C 50. FT. GROSS PER PERSON
Subject to compliance with all regulations
of State and Local Codes cope Drawings
Wn".IMIouN, a ofr W, ofNepnl p,muw lmW 4mc"N
City
off Cannel ��a,.,p.,n1111,t,e�,."nn<m,nemn.the m.i".1 eniIfIrn.mme
\OIwrGSPAAL M,ra "nw,o,ai., na�a„m on.r,bm.,rmhwa., . op,
any .meo„", ass�m ei ,,,..k 2a.r2a r"
..nod nememn,e,,,no we onekma.nn, s=n=�n�ll the
'end"welder fw, cA, mexm mrmrt9mm10nne
DATE: 08/13/19
P OJ�Gi ��SGRIPiION
THIS PROJECT 15 FOR THE GONSTRUGTION OF A UPSGALE
RESTAURANT AND TAVERN. THE PROJECT TO BE LOCATED
AT MAIN STREET AND THE MORON, IN THE GITY OF GARMEL.
PROJECT 15 NEW TENANT FINISH IN EXISTING STRUGTURE.
FIRE AGGESS SHALL BE PROVIDED ALL AROUND BUILDING.
5PAGEI5 MASONRY AND STEEL GON5TRUGTION-5UPPRE55EL
GENERAL PLAN NOTES
* BIDS SHALL ACKNOWLEDGE ALL ADDENDA
w MECHANICAL, PLUMBING AND ELECTRICAL SCOPES
ARE SPEC, BID PACKAGES KITH ALTERNATES AS
SUBMITTED AND APPROVED
w ANY DISCREPANCIES IN PLANS SHALL BE BROUGHT
TO DESIGNERS ATTENTION WHILE BIDDING
' IN EVENT OF D15CREPANGY THE GREAT OF THE
SCOPES DESCRIBED SHALL BE CONSIDERED BASE
BID
ALL WORK SHALL COMPLY KITH STATE AND
LOCAL CODES AND MIGHT NOT DESCRIBE EVERY
PIECE REQUIRED FOR COMPLIANCE
« ALTERNATES TO ALL DESCRIBED MATERIALS MAY
BE SUBMITTED TO DESIGNER/OHNER FOR APPROVAL
MAXIMUM TRAVEL 015TANCE TO EXIT
200'
MAXIMUM DEAD END CORRIDOR
20'
EGRESS WIDTH PER PER50N .2",3" FOR STAIRS
MINIMUM GORRIDOR WIDTH
44"
MINIMUM STAIR WIDTH
44"
MINIMUM GLEAR OPENING OF EXIT DOORS
52"
MINIMUM NUMBER OF EXITS
2 REQUIRED
FIXTURE COUNT: NUMBER OF OGGILI OF EACH 5EX
TOTAL OCCUPANCY: 202 / 2 = 101
RESTAURANT/GAPE ASSEMBLY:
SEASONAL DINING: 41
DINING ROOM SEATING: 105
TAVERN AREA SEATING: 42
STAFF: II
PLUMBING OCCUPANCY LOAD: 202 PERSONS
MALE - I PER 75
101/15 = 2 REG. - 3 PROVIDED
FEMALE - I PER 15
101/15 = 2 REG. - 3 PROVIDED
LAVATORIES- I PER 200
202/200 = 2 REG. 2 PROVIDED
SERV. SINK - I PER FLOOR
= I REQ. - I PROVIDED
DRK FOUNTAIN-1 PER FLOOR
= NOT REG. = RESTAURANT OCCUPANCY
MIN. FLAME SPREAD RATINGS (PER SEC. 805 AMC) TABLE 803.4)
EXIT ACCESS CORRIDORS CLA55 A - FLAME SPREAD 0-25,
AND OTHER EXITHAY5 SMOKE DEVELOPED 0-450
ROOMS AMC) GLASS G - FLAME SPREAD 16-200,
ENCLOSED SPACES SMOKE DEVELOPED 0-450
NOTE:
SELECTED FIRE SUPPRESSION CONTRACTOR SHALL
SUBMIT CERTIFIED PLANS OF ALL WORK TO BE PERFOMED
TO BUILDING DEPARTMENT FOR APPROVAL PRIOR TO
WORK BEING PERFORMED
NOTE:
INSULATING MATERIALS TO INCLUDE FACINGS
SUCH AS VAPOR RETARDERS, BREATHER
PAPERS, AND ALL LAYERS OF REFLECTIVE
FOIL, CONCEALED INSULATION SHALL HAVE
A FLAME SPREAD INDEX OF NOT MORE THAN
25 AND SMOKE -DEVELOPED INDEX OF NOT
MORE THAN 450.
PH:
LANI%ORI;� 5GOPF=
THE LANDLORD SHALL PROVIDE THE FOLLOWING CONDITIONS
aJ Floor- Landlord Shall provide an exposed unsealed
concrete floor Slab designed to support O live load Of 100
pound per sctuore foot. Structural grade beams may be
located Under the slab. No penetrations of the Structural
Slab shall be made in connection with Tenant's Work withovt
Landlord's written approval.
IC.) Electrical- Landlord shall provide one (1) 400 amp '2201
volt, 3 phase, 4 wire circult electrical Service panel In per
the Landlord's PICKS
6.) Hood Exhaust- Landlord shall provide opening in the wall
Of Leased Premises for Tenant to install it's venting system,
for Tenant's hood
d.) HVAG- Landlord Shall provide one ton of air conditioning
for every 200 5ctuore feet of the Leased Premise5 Mithout
distribution ductwork, which Mill be installed by Tenant
e.) Landlord shall provide bi-fold Lenai Style doors per
Tenant's floor plan.
L.OGATION MAP
SCALE: NTS
VIOINIfiY MAP
SCALE: HIS
PROJECT LOCATION
211 MOST MAIN STREET
GARMEL, IN 46O32
5HE=EE7 NDEEX
7I.1 TITLE SHEET AND CODE REVIEW
71.2 SCOPE MATRIX
71.5 ADA NOTES
71.4 ADA NOTES
A51.1 ARCHITECTURAL SITE PLAN
DI.1 DEMOLITION PLAN Z
LSI.I LIFE SAFETY PLAN wii WW U o a o N U
L51.2 LIFE SAFETY DETAILS r-4 cC a E
S.I CONCRETE SLAB PLAN U � Z J
O CG C) 7
S2.1 HVAG SUPPORT DE0K5 Q q 4
W '0 Lc p
AI.I ANNOTATED FLOOR PLAN - MAIN X O o
AI.2 DIMENSIONAL FLOOR PLANS a Gin Z a
U z 4 o E
A1.3 INTERIOR FINISH PLANS r� a M
AIA REFLECTED CEILING PLANS U d z a
N
A2.1 EXTERIOR ELEVATIONS ti
A2.2 INTERIOR ELEVATIONS
A5.1 EXTERIOR WALL SECTIONS
A4.1 ENLARGED RESTROOM PLANS AND ELEVS
A4.2 ENLARGED BAR AREA PLANS AND DETAILS
A4.3 ENLARGED KITCHEN AREA PLANS Q uiaq "'a
:� ��G No.
°"%
A4.4 KITCHEN HOOD PLAN AND DETAILS ��„/
A4.5 MILLWORK DETAILS S00033266
i
A4.6 MILLWORK DETAILS
A5.1 DOOR $ WINDOW SCHEDULE
MO.1 MECHANICAL SCHEDULES AND NOTES Gx] W Q
MI.I MECHANICAL PLANS c�V cf) M~M
ei
W
M2.1 MECHANICAL EOPMT PLANS Q O w
PH PLUMBING SANITARY PLANS
PI.2 PLUMBING VENTING PLANS
P1.3 PLUMBING WATER PLANS z W
N
PIA GAS PIPING PLANS z �+ P2.1 PLUMBING DETAILS N O 1� Z OiT
P3.1 PLUMBING ISOMETRICS a=ywi~
EI.O ELECTRICAL NOTES AND SGHEDULE5 Ca F W
EI.I LIGHTING PLANS O FA U-)
I
E2.1 POWER PLANS U
E2.2 LOW VOLT PLANS 0.
N
E2.3 POWER RISERS AND PANEL SCHEDULES
T17LE SHEET AND CODE R YI