Loading...
HomeMy WebLinkAboutGN 100.1 - TITLE SHEETSavor Restaurant -Carmel 2.21 e5i I Street _ SAie 10:2 Art5 1 e5ien Di5tril Carmel, IN 46032 APPLICABLE CODES: INDIANA BUILDING GODE - 2014 EDITION (2012 IBC IST EDITION) INDIANA PLUMBING GODE - 2012 EDITION INDIANA ELEGTRIGAL CODE - 200cl INDIANA MEGHANIGAL GODE - 2014 EDITION (2012 IMG 15T EDITION) INDIANA ENERGY CONSERVATION CODE 2010 EDITION (A5HRAE aO.0 INDIANA FIRE GODE - 2014 EDITION (IFG 2012 IST EDITION) INDIANA FUEL 6A5 CODE - 2014 EDITION (IF6G 2012 IST EDITION) ANSI I1-7.1 - 200N CONTACT INFORMATION: John Bennett JT Designers, Inc. 555 5. Arlington Ave, Ste 105 Indianapolis, -IN 46219 317-826-1166 jtdesignersinc� gma i Lcom PROJECT. SAVOR RESTAURANT LOCATION: Moron $ Moir Street Carmel, IN PRIMARY OCCUPANCY CLASSIFICATION: A2 - RESTAURANT (PER SECTION 505) OCCUPANCY LOAD: 150 DESIGNED SEATING (INTERIOR) II STAFF CONSTRUCTION TYPE: TYPE II-B Sprinkled- CONSTRUCTION FIRE SUPPRESSION: FIRE EXTINGUISHERS / FIRE 5UFFRE55ION BUILDING PROPERTIES AREA (GROSS): +/- 5520 5F LEASE AREA/ 5654 5F NET AREA HEIGHT: 10'-O" - INSIDE CLEAR / I4'-O" - EXTERIOR FACADE HEIGHT ALLOWABLE: 55'-0"(PER TABLE 505) FIRE PROTECTION REOUIREMENT5 TABLE 601 FOR TYPE III-B STRUGTURAL FRAME O HOUR INCLUDING COLUMNS, GIRDERS, TRUSSES BEARING WALLS EXTERIOR O HOUR INTERIOR O HOUR NONBEARIN6 HALLS AND PARTITIONS INTERIOR O HOUR FLOOR CONSTRUCTION INCLUDING SUPPORTING AND JOISTS O HOUR SHAFTS O HOUR ROOF CONSTRUCTION INCLUDING SUPPORTING O HOUR y7J dill; 1iiiiWN ]04r�roJt TYPE III-B EXTERIOR NONBEARIN6 HALLS < 5' - I HR. AND NO OPENING PERMITTED >- 5' -< 10, - I HR. AND 10% OPENING LE55 THAN 10' 2 10, S 30' - O HOUR 130, - O HOUR EXIT CORRIDOR I HOUR (PER TABLE 10043.2.1) EGRESS DEMAND SEG 1003.2.2.1 AND 1003.2.2.2 EDUGATIONAL CLASSROOM AREA 20 50. FT. NET PER PERSON ASSEMBLY WITHOUT FIXED SEATS CONCENTRATED -750. FT. NET PER PERSON UNCONGENTRATED 15 50. FT. NET PER PERSON PLATFORM 15 50. FT. NET PER PERSON KITCHEN 200 50. FT. GRO55 PER PERSON AGGESSORY STORAr 300 50. FT. GRO55 PER PERSON RELEASED FOR CONSTRUCTION- 300 50. FT. OR055 PER PERSON 0C 50. FT. GROSS PER PERSON Subject to compliance with all regulations of State and Local Codes cope Drawings Wn".IMIouN, a ofr W, ofNepnl p,muw lmW 4mc"N City off Cannel ��a,.,p.,n1111,t,e�,."nn<m,nemn.the m.i".1 eniIfIrn.mme \OIwrGSPAAL M,ra "nw,o,ai., na�a„m on.r,bm.,rmhwa., . op, any .meo„", ass�m ei ,,,..k 2a.r2a r" ..nod nememn,e,,,no we onekma.nn, s=n=�n�ll the 'end"welder fw, cA, mexm mrmrt9mm10nne DATE: 08/13/19 P OJ�Gi ��SGRIPiION THIS PROJECT 15 FOR THE GONSTRUGTION OF A UPSGALE RESTAURANT AND TAVERN. THE PROJECT TO BE LOCATED AT MAIN STREET AND THE MORON, IN THE GITY OF GARMEL. PROJECT 15 NEW TENANT FINISH IN EXISTING STRUGTURE. FIRE AGGESS SHALL BE PROVIDED ALL AROUND BUILDING. 5PAGEI5 MASONRY AND STEEL GON5TRUGTION-5UPPRE55EL GENERAL PLAN NOTES * BIDS SHALL ACKNOWLEDGE ALL ADDENDA w MECHANICAL, PLUMBING AND ELECTRICAL SCOPES ARE SPEC, BID PACKAGES KITH ALTERNATES AS SUBMITTED AND APPROVED w ANY DISCREPANCIES IN PLANS SHALL BE BROUGHT TO DESIGNERS ATTENTION WHILE BIDDING ' IN EVENT OF D15CREPANGY THE GREAT OF THE SCOPES DESCRIBED SHALL BE CONSIDERED BASE BID ALL WORK SHALL COMPLY KITH STATE AND LOCAL CODES AND MIGHT NOT DESCRIBE EVERY PIECE REQUIRED FOR COMPLIANCE « ALTERNATES TO ALL DESCRIBED MATERIALS MAY BE SUBMITTED TO DESIGNER/OHNER FOR APPROVAL MAXIMUM TRAVEL 015TANCE TO EXIT 200' MAXIMUM DEAD END CORRIDOR 20' EGRESS WIDTH PER PER50N .2",3" FOR STAIRS MINIMUM GORRIDOR WIDTH 44" MINIMUM STAIR WIDTH 44" MINIMUM GLEAR OPENING OF EXIT DOORS 52" MINIMUM NUMBER OF EXITS 2 REQUIRED FIXTURE COUNT: NUMBER OF OGGILI OF EACH 5EX TOTAL OCCUPANCY: 202 / 2 = 101 RESTAURANT/GAPE ASSEMBLY: SEASONAL DINING: 41 DINING ROOM SEATING: 105 TAVERN AREA SEATING: 42 STAFF: II PLUMBING OCCUPANCY LOAD: 202 PERSONS MALE - I PER 75 101/15 = 2 REG. - 3 PROVIDED FEMALE - I PER 15 101/15 = 2 REG. - 3 PROVIDED LAVATORIES- I PER 200 202/200 = 2 REG. 2 PROVIDED SERV. SINK - I PER FLOOR = I REQ. - I PROVIDED DRK FOUNTAIN-1 PER FLOOR = NOT REG. = RESTAURANT OCCUPANCY MIN. FLAME SPREAD RATINGS (PER SEC. 805 AMC) TABLE 803.4) EXIT ACCESS CORRIDORS CLA55 A - FLAME SPREAD 0-25, AND OTHER EXITHAY5 SMOKE DEVELOPED 0-450 ROOMS AMC) GLASS G - FLAME SPREAD 16-200, ENCLOSED SPACES SMOKE DEVELOPED 0-450 NOTE: SELECTED FIRE SUPPRESSION CONTRACTOR SHALL SUBMIT CERTIFIED PLANS OF ALL WORK TO BE PERFOMED TO BUILDING DEPARTMENT FOR APPROVAL PRIOR TO WORK BEING PERFORMED NOTE: INSULATING MATERIALS TO INCLUDE FACINGS SUCH AS VAPOR RETARDERS, BREATHER PAPERS, AND ALL LAYERS OF REFLECTIVE FOIL, CONCEALED INSULATION SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450. PH: LANI%ORI;� 5GOPF= THE LANDLORD SHALL PROVIDE THE FOLLOWING CONDITIONS aJ Floor- Landlord Shall provide an exposed unsealed concrete floor Slab designed to support O live load Of 100 pound per sctuore foot. Structural grade beams may be located Under the slab. No penetrations of the Structural Slab shall be made in connection with Tenant's Work withovt Landlord's written approval. IC.) Electrical- Landlord shall provide one (1) 400 amp '2201 volt, 3 phase, 4 wire circult electrical Service panel In per the Landlord's PICKS 6.) Hood Exhaust- Landlord shall provide opening in the wall Of Leased Premises for Tenant to install it's venting system, for Tenant's hood d.) HVAG- Landlord Shall provide one ton of air conditioning for every 200 5ctuore feet of the Leased Premise5 Mithout distribution ductwork, which Mill be installed by Tenant e.) Landlord shall provide bi-fold Lenai Style doors per Tenant's floor plan. L.OGATION MAP SCALE: NTS VIOINIfiY MAP SCALE: HIS PROJECT LOCATION 211 MOST MAIN STREET GARMEL, IN 46O32 5HE=EE7 NDEEX 7I.1 TITLE SHEET AND CODE REVIEW 71.2 SCOPE MATRIX 71.5 ADA NOTES 71.4 ADA NOTES A51.1 ARCHITECTURAL SITE PLAN DI.1 DEMOLITION PLAN Z LSI.I LIFE SAFETY PLAN wii WW U o a o N U L51.2 LIFE SAFETY DETAILS r-4 cC a E S.I CONCRETE SLAB PLAN U � Z J O CG C) 7 S2.1 HVAG SUPPORT DE0K5 Q q 4 W '0 Lc p AI.I ANNOTATED FLOOR PLAN - MAIN X O o AI.2 DIMENSIONAL FLOOR PLANS a Gin Z a U z 4 o E A1.3 INTERIOR FINISH PLANS r� a M AIA REFLECTED CEILING PLANS U d z a N A2.1 EXTERIOR ELEVATIONS ti A2.2 INTERIOR ELEVATIONS A5.1 EXTERIOR WALL SECTIONS A4.1 ENLARGED RESTROOM PLANS AND ELEVS A4.2 ENLARGED BAR AREA PLANS AND DETAILS A4.3 ENLARGED KITCHEN AREA PLANS Q uiaq "'a :� ��G No. °"% A4.4 KITCHEN HOOD PLAN AND DETAILS ��„/ A4.5 MILLWORK DETAILS S00033266 i A4.6 MILLWORK DETAILS A5.1 DOOR $ WINDOW SCHEDULE MO.1 MECHANICAL SCHEDULES AND NOTES Gx] W Q MI.I MECHANICAL PLANS c�V cf) M~M ei W M2.1 MECHANICAL EOPMT PLANS Q O w PH PLUMBING SANITARY PLANS PI.2 PLUMBING VENTING PLANS P1.3 PLUMBING WATER PLANS z W N PIA GAS PIPING PLANS z �+ P2.1 PLUMBING DETAILS N O 1� Z OiT P3.1 PLUMBING ISOMETRICS a=ywi~ EI.O ELECTRICAL NOTES AND SGHEDULE5 Ca F W EI.I LIGHTING PLANS O FA U-) I E2.1 POWER PLANS U E2.2 LOW VOLT PLANS 0. N E2.3 POWER RISERS AND PANEL SCHEDULES T17LE SHEET AND CODE R YI