HomeMy WebLinkAboutLS 100.2 - LIFE SAFETY DETAILS6ENERAL NOTE5
I. Fire barrier shall be continuous from outside wall to outside wall,
from another fire bonier to a fire barrier, or a combination thereof:
Including continuity through all concealed spaces such as those
Found above a ceiling, including Interstitial spaces.
Openings through floors, such as stairways, elevator hoistways, and
shaftNol used for light, ventilation or building services, shall be
enclosed with fire borrlers (vertical) such as wall or partition
assemblies. Such enclosures shall be continuous from floor to floor.
Openings shall be protected as appropriate for the fire resistance
rating of the barrier.
Passages of pipes, conduits, bus ducts, cables, wires, abducts,
pneumatic ducts, and similar buildings service equipment through fire
barriers shall be protected as follows:
Fire barriers oholl be eFfectively and permanently Identified with 2"
stenciling above any decorative ceiling and concealed spaces.
(Smoke/Fire barrier protect all openings Installed 12 ft. on center.)
2. Rooms or areas designated for storage, mechanical, furnace room
or janitor closet shall be separated from the rest of the building
by goad one hour rated fire -resistive construction with all openings
protected by 45 minute labeled fire door assembly.
3. All exit doors to have approved panic hardware (NFPA 101 5-2.1.1).
4. The floor on both sides of a door shall be level and shall have the
same elevation on both sides of the door, for a distance on each
side at least equal to the width of the widest single door
(NFPA 101 5-2.1.3.3).
The space between the penetrating item and fire barrier shall be 5. All landings and steps shall be solid with no perforations at all.
Filled with a material capable of maintaining the fire resistance rating There shall be no nosings or open toe risers on any steps regardless
of the Fire barrier product. Product used must meet test methods of size and shall be at least 44 Inches wide and have treads with
ASTM Eb4 or ILL 1419 for fire ratil a minimum of 1 Inches In height. Disable access landings shall be 60
Inches.
Provide detalled Wall, Floor/celling assemblies, specify materials and
oive laboratory listing S coslan numbers. Show Fire protection under 6. Provide sturdy handrails on both sides of any steps three or more
ubs, showers, Fireplace and VAC. 61ve detailed fire stopping in risers In height (54" handrail). (42" guardrail along open side of stairs)
concealed spaces of each Floor/ceiling level and wall
(NFPA 101 6-2.2, 6F60-13 $ 14). 1. Every door Inside and outside every building shall be provided with
handicap hardware (levers, panic hardware, or a -shape designed
devices, etc.).
Subject to compliance with all regulations
of State and Local Codes
City of Camel
PIT:
DMIC: Vu/ 101 1J
Ia�vlz��H��val�m:a
FIRE SEALANT AT 1 Y 1-
F PAlc I BAR JUST -
INSTALL FIRE SEALANT UP
INTO LORRE6ATI045 OF
METAL ROOF DEGKIN6
RATED SEPARATION
F I RE: 5AR I ER BALL :�)EfiAL
SCALE: NTS
SCHEDULED WALL CONSTRUCTION
CONTINUOUS PERIMETER WOOD
BLOCKING
ROLLED EDGE SEMI I-REGESSED
FIRE EXTINGUISHER CABINET -
ROUGH OPENING 25" x IO 1/2" x 3"
- SIM. TO LARSEN'S (B240q-R5)
BOTTOM OF FIRE EXTINGUISHER
GABINET SHALL BE + 4'-O" A.F.F.
NOTE: THE CONTRACTOR SHALL
PROVIDE AND INSTALL FIRE
EXTINGUISHERS AS REQUIRED BY
NFPA 10, COORDINATE WITH
LOCAL FIRE DEPT.
7-IRE EXT. CA5INET L7�E!7AIiL..
SCALE: NTS