HomeMy WebLinkAboutLS 100.2 - LIFE SAFETY DETAILS6ENERAL NOTE5 I. Fire barrier shall be continuous from outside wall to outside wall, from another fire bonier to a fire barrier, or a combination thereof: Including continuity through all concealed spaces such as those Found above a ceiling, including Interstitial spaces. Openings through floors, such as stairways, elevator hoistways, and shaftNol used for light, ventilation or building services, shall be enclosed with fire borrlers (vertical) such as wall or partition assemblies. Such enclosures shall be continuous from floor to floor. Openings shall be protected as appropriate for the fire resistance rating of the barrier. Passages of pipes, conduits, bus ducts, cables, wires, abducts, pneumatic ducts, and similar buildings service equipment through fire barriers shall be protected as follows: Fire barriers oholl be eFfectively and permanently Identified with 2" stenciling above any decorative ceiling and concealed spaces. (Smoke/Fire barrier protect all openings Installed 12 ft. on center.) 2. Rooms or areas designated for storage, mechanical, furnace room or janitor closet shall be separated from the rest of the building by goad one hour rated fire -resistive construction with all openings protected by 45 minute labeled fire door assembly. 3. All exit doors to have approved panic hardware (NFPA 101 5-2.1.1). 4. The floor on both sides of a door shall be level and shall have the same elevation on both sides of the door, for a distance on each side at least equal to the width of the widest single door (NFPA 101 5-2.1.3.3). The space between the penetrating item and fire barrier shall be 5. All landings and steps shall be solid with no perforations at all. Filled with a material capable of maintaining the fire resistance rating There shall be no nosings or open toe risers on any steps regardless of the Fire barrier product. Product used must meet test methods of size and shall be at least 44 Inches wide and have treads with ASTM Eb4 or ILL 1419 for fire ratil a minimum of 1 Inches In height. Disable access landings shall be 60 Inches. Provide detalled Wall, Floor/celling assemblies, specify materials and oive laboratory listing S coslan numbers. Show Fire protection under 6. Provide sturdy handrails on both sides of any steps three or more ubs, showers, Fireplace and VAC. 61ve detailed fire stopping in risers In height (54" handrail). (42" guardrail along open side of stairs) concealed spaces of each Floor/ceiling level and wall (NFPA 101 6-2.2, 6F60-13 $ 14). 1. Every door Inside and outside every building shall be provided with handicap hardware (levers, panic hardware, or a -shape designed devices, etc.). Subject to compliance with all regulations of State and Local Codes City of Camel PIT: DMIC: Vu/ 101 1J Ia�vlz��H��val�m:a FIRE SEALANT AT 1 Y 1- F PAlc I BAR JUST - INSTALL FIRE SEALANT UP INTO LORRE6ATI045 OF METAL ROOF DEGKIN6 RATED SEPARATION F I RE: 5AR I ER BALL :�)EfiAL SCALE: NTS SCHEDULED WALL CONSTRUCTION CONTINUOUS PERIMETER WOOD BLOCKING ROLLED EDGE SEMI I-REGESSED FIRE EXTINGUISHER CABINET - ROUGH OPENING 25" x IO 1/2" x 3" - SIM. TO LARSEN'S (B240q-R5) BOTTOM OF FIRE EXTINGUISHER GABINET SHALL BE + 4'-O" A.F.F. NOTE: THE CONTRACTOR SHALL PROVIDE AND INSTALL FIRE EXTINGUISHERS AS REQUIRED BY NFPA 10, COORDINATE WITH LOCAL FIRE DEPT. 7-IRE EXT. CA5INET L7�E!7AIiL.. SCALE: NTS It� b I EIT U L7�WNo� o � x 0c: V ('n M G Q 1C'oy ss W a w 2c 00 a M M ti 5RALL�E EXIT 5I&NA&Fm LSL2 SCALE: NTS FIFE 5AFE7Y E7A L5 L I ,2 N 3! Ems M [� O aZCn o Vlww`n� N