HomeMy WebLinkAboutM 001.0 - MECHANICAL NOTESH\/AC CSENERALE N07EI5: I. The heating, air conditioning equipment and Installation shall conform to all current Notional, State and Local Codes. 2. The Mechanical Contractor to clearly label each unit by area served using I" stencil or engraved plastic. 5. The Mechanical Contractor shall coordinate supply all and return air ducts with General Contractor so duct encasements may be Installed at the proper locations, as not to affect the structural system of the building. 4. The Mechanical Contractor is to coordinate gas piping with Plumbing Contractor to assure correct size and final locations of the units, and piping servicing the units. Piping in attic, to be suspended from trusses a minimum of 12" above insulation for proper leak test and future service and inspection. The M.G. to verify all aspects of gas service with local utility. 5. The Mechanical Contractor shall be responsible for pouring concrete pad for units. Units to be 50" clear of butlding or at manufacturer's recommendations, which ever Is greater. 6. The Mechanical Contractor shall coordinate all electrical requirements of all units with the Electrical Contractor to assure final correct locations of the Unit's disconnects. All equipment to be provided with Internal fuse protection, per NEC., State and local Codes. 1. All Exhaust Fans and Ventilators shall have back draft dampers. Units provided and installed by the Mechanical Contractor, power and wiring by the Electrical Contractor. Z. Ductwork sholl be Insulated. See Ductwork 6eneral Notes. 9. The Mechanical Contractor to provide 5/4" PVC condensate drains with slope to positive drainage outside of building. Provide sheet metal auxiliary drain pan, at attic units, 2" deep under each cooling toll. Provide 3/4" condensate drain separated from cooling toll all Slope to positive drain with straps at 48" o.c. to avoid sagging of lines. Pitch auxiliary drain pans and cooling coils slightly In direction of condensate flow. 10. The Mechanical Contractor shall install fire dampers in all ducts passing through Fire Rated Walls and Ceilings Cd_roteo ac 'F. on t,x,e Lra:apro=i and all other locations specified by the State Fire Marshall or Authority Having Jurisdiction. 11. Mechanical equipment shall be casts bid as 5m power supply. Mechanical contractor shall be responsible For verifying available power supply prior to ordering and installing equipment. 12. The Mechanical Contractor to provide and Install specified control devices and Low Voltage Wiring. Thermostats to be Fully Programmable -I Day. Provide "tamperproof" Covers with lock for all thermostats. 15, Fresh / Outside Air shall conform to ASHRAE 62 'Ventilation for Acceptable Indoor Air Quality" and all State and Local Codes. 14. 5.E.E.R. / E.E.R. - as rated In accordance with U.S. Government D.O.E. Test procedure and A.R.I. Standard 210-19. 15. AP.U.E. - Annual Fuel Utilization Efficiency as established by U.S. Government Standard D.O.E. Test. 16. The Mechanical contractor shall provide Balancing Report prior to final occupancy. THESE NOTES SHALL APPLY UNLESS OTHERWISE INDICATED BY DRANIN65 OR SPECIFICATIONS. I Duct dimensions are shown as clear inside dimensions. Where Internal insulation is called for, dimensions shall be increased by the thickness of Insulation. 2 Portions of ducts visible throwgh diffusers, grilles and registers In Finished areas shall be painted flat black. 5 Coordinate exact locations of all ceiling diffusers, registers and exhaust grilles, ductwork, etc. with lighting laout, reflected telling plan and owners layout, so they will remain unolceXucted. 4 Coordinate all duct penetrations with Structural Drowings. 5 Supply and return ducts shall be sheet metal with I" thick internal acoustical lining. -OR- Wrap all supply and return ductwork with 2" thick, 3/4 It. density foil faced insulation. -OR- Where applicable, Owens Corning I" Hbergloss duct board. 6 All ductwork shall be fabricated and Installed In accordance with SMACNA Duct Manual and NFPA qC-A. 9 Flexible ductwork not to exceed 6'. When longer runs occur, use 28 So. round ductwork to obtain required lengths. 8 Provide flexible connection where supply and return air ducts connect to unit. 9 Ductwork openings shall be coordinated with MEN For Installation by this Contractor. The M.G. to provide ductwork for exterior, Insulated and wtsother-protected and install return air ductwork as required. 10 These drawingqs indicate duct for size and approximate location. Ducts may need to 6e moved slightly to insure no obstruction in installation. Id�1�:kl�ild�ldd�Rf��ild�I�lil�l�l Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/13/19 MECHANICAL SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION ® CEILING SUPPLY DIFFUSER ( SAD) 5-12x8 SUPPLY DUOT - WIDTH x DEPTH ROUND CEILING SUPPLY DIFFUSER ( SAR) R-12xb RETURN DUCT - WIDTH x DEPTH ® CEILING SUPPLY GRILLE ( SAS) ® SQUARE / REGTA146LE SUPPLY DUCT SECTION 8 CEILIN6 / FLOOR SLOT DIFFUSER ( SAS) (2) ROUND SUPPLY DUCT SECTION n WALL SUPPLY GRILLE ( SAG ) SQUARE / REGTAN61-E RETURN DUCT SECTION ■ GEILING RETURN EGG -GRATE REGISTER ( RAD) ROUND RETURN DUCT SECTION n WALL RETURN GRILLE ( RAG) ® SQUARE -TO -ROUND TRANSITION RFD FIRE DAMPER ®FAN EXHAUST FAN �VD VOLUME DAMPER ®FAN EXHAUST FAN WITH L16HT MOTORIZED DAMPER E-6x4 EXHAUST DUCT - WIDTH x DEPTH THERMOSTAT WITH UNIT D. CONTROLLED 0 EXHAUST WALL GAP r7RIL.L , :;IFFUSEII 4 RE&HER sCHEr�)L)LE TYPE MANUFACTURER 4 MODEL NUMBER SHAPE AIR FLOW (GFM) VELOGI TY (FPM) N.G. RATING TYPE MAT'L FINISH CONTROL SAID I PRICE: 5CO SERIES SQUARE 100 - 550 500 - SOO < 20 SUPPLY AIR DIFFUSE R/T-BAR LAY-IN/NECK AS PER PLANS STL WHITE O.B.D. SAD 2 PRICE: SCD SERIES ROUND 100 - 550 500 - SOO < 20 SUPPLY AIR DIFFUSER / DUCT MOUNT /NECK AS PER PLANS 5TL WHITE O.B.D. SAR PRICE: 510 SERIES REGT 100 - 550 500 - SOO < 20 SUPPLY AIR REGISTERS MOUNT DIRECTLY TO DUCT 5TL STEEL O.B.D. RAG PRICE: 550 F 5 A 512 50/RECT q50 - 1,125 500 - 400 < 20 RETURN 6RILLE/FLUSH MOUNT NECK AS PER PLANS 5TL WHITE NOTE: ALL FIXTURES, LISTED ABOVE, MAY BE BID WITH A PRE -APPROVED EQUAL. Ha,A7 PUMP _QkIR CANDLING AND H�EA7 INC EQUIPMENT SCHEDULE DESCRIPTION SUPPLY FAN GULL 1�:U HEATING FILTERS � CONDENSER ,.EG_ ON ELECTRICAL UNIT MARK MANUFACTURER MODEL NUMBER TOTAL G.F.M. O.A. G.F.M. ESP MOTOR H.P. E.A.T. MBH TYPE OUTPUT MBH / kW TYPE (tt) THK. O.A. TEMP LOW O.A. CONDENSER COMPRESSOR q -� ?� U p' TONNAGE WEIGHT DB WB TH SH AREA FAN HP. EER KW AMP FU I TRANE INH2DI20A960VA 2000 25 % 08 ]5 5A5 100 / 125 2 5TACE T-A (4) 2 115 1 8 20 5 205 COIL TRANS 4TXCGDOIOGC3HGB OUI TRANS 4TTZ006OA10006 qO 61 50 48 90 61 24 5 13 64 31 205 1 31 50 5 410 FU 2 TRANE TUH2D120A960VA 2,000 25 % Ob T5 6A5 100 / 125 2 5TA6E T-A (4) 2 115 1 8 20 5 205 COIL 2 TRANE 4TX66DOIOG63HGB GU2 TRANS 41TZCOb0A10006 90 bl 60 48 90 bl 24 5 13 6.4 31 208 31 50 5 410 FU 3 TRANS IDH2DI20A960VA 2p00 25 % 08 ]5 6A5 100 / 125 2 STAGE T-A IIS 8 20 5 205 COIL 3 TRANS 4TXCGDOIOGG3HGB GU 3 TRANS 4TTZOO60AI000G qO 61 50 48 90 61 24 5 13 64 31 205 1 31 50 5 410 FU 4 TRANE TUH2D120A960VA 2,000 25 % Ob T5 6A5 100 / 125 2 5TA6E T-A 115 1 8 20 5 205 COIL 4 TRANE 4TX06DOIOC63H68CU4 F(4)2 TRANE 4TTZ0060AI0006 qO 6l 60 48 90 6T 24 5 13 6.4 31 208 1 31 50 5 410 FU 5 TRANE TUH26100A948VA I,600 25% 0.5 15 6A5 80 /100 2 5TA6E TA 115 1 8 20 35 205 GOIL 5 TRANE 4TX613048BG3HGB CU 5 TRANE 4TTZ004551000A 40 90 61 24 5 13 b.4 31 208 I 26 40 35 410 FU 6 TRANE TUH2O100A948VA L600 25 % 08 .15 6A5 80 / 100 2 STAGE T-A H) 2 IIS 1 8 20 35 205 COIL b TRANE 4TX6B0488C3Hl M41 nu TRANE 4TTZ00483I000A 4C 90 bl 24 5 13 6.4 31 208 1 26 40 35 410 NOTES: I. ALL UNITS TO HAVE ECONOMIZER PROVIDED 4 INSTALLED. 2. ALL UNITS SHALL BE SET IN DRIP PAN H/ DRAIN LINE TO EXTERIOR OF BUILDING. 3. ALL UNITS SHALL BE COMPLETE WITH -I-DAY ELECTRONIC FULLY PROGRAMMABLE THERMOSTAT W/ LOCKABLE GOVER 4. ALL UNITS SHALL BE EQUIPPED WITH SMOKE DETECTOR IN RETURN AIR DUCT, PRIOR TO ENTERING UNIT, 50 THAT IN THE EVENT OF FIRE, DETECTOR SHALL DEACTIVATE BLOWER MOTOR S SOUND ALARM. 5. COIL SHALL BE CONNECTED TO SAIL SWITCH IN RETURN AIR DUCT 50 THAT IN THE EVENT BLOWER MOTOR 15 DEACTIVATED, COIL SHALL BE DEACTIVATED AS WELL, TO PREVENT "FREEZE-UP". COOLER EQUIPMENT MARK MANUF MOPEL NUMBER GFM DUET SIZ APPPROX. MAX.SONE VOLTS PHASE REMARKS RMOTOR HP EVAP I NOR -LAKE .. 400 - 250 5.0 I550 I/8 II5 1 EG NOR -LAKE .. -- - 250 5.0 I550 5/8 208 I PH: NOTE SPECIFIC CHART VALUES ARE FOR REFERENGE ONLY ALL PERFORMANCE SHALL BE VERIFIED AGAINST SUBMITTAL SHEETS FORM SUPPLIER. MF6 FOR SPECIFIC OF PERFORMANCE AND EQUIPMENT DESCRIPTIONS. EXHAUST FAN SCHEDULE MARK MANUF MODEL NUMBER GFM DUCT SIZE APPROX. SP MAX. SONSnt LEVEL PHASE REMARKS 6REENHEGK SP-A250 225 8"0.250 5.0 1 I; 2 2 6REENHEGK 5P-A250 225 8"0.250 5.0 1 I;2 2 6REENHEGK 240HP-50 1200 PER PLAN .75 2.30 I I; 2 NOTES: 1. DUCTS TO TIED TO MAIN EXHAUST FOR 51111 HALL PENETRATION 2. TIE ACTIVATION OF FAN INTO L16HT 5WITGH FOR 51MULATEM005 OPERATION OF FAN AND LIGHTS M CHAN1CAL PLAN (NOTES 0 Doi o ca H­ « b0 zM J a �zsc zap o �U M E N E-t N