Loading...
HomeMy WebLinkAboutC507 - PLAN AND PROFILE (STORM)DRAINAGE ESMT709 RIM=864.00 704A RIM=858.04 68' OF 18" RCP @1.17% 703 RIM=856.85 391' OF 18" RCP @0.54%702 INV =851.00 STR. #704A INLET AM; R-3405TC: 858.04INV. OUT 854.00 (18" RCP (E))STR. #701 OUTLET STRUCTURETC: 855.50INV. OUT 845.05 (24" RCP (SE))STR. #701A MH 4' DIA.;R-1772TC: 853.44INV. IN 843.57 (24" RCP (NW))INV. OUT 843.47 (24" RCP (E)) 126' 1.17% 24" RCP STR. #703 MH 4' DIA; R-3405TC: 856.85INV. IN 851.90 (18" RCP (W))INV. OUT 851.80 (18" RCP (E)) 391' 0.54% 18" RCP 68' 1.17% 18" RCP INV. OUT 851.00 (18" RCP)STR. #70230'W DRAINAGE ESMTSILVARA COURTWWWWWWWW701 RIM=855.50 16' OF 24" RCP @0.86% 1 2 6 ' O F 2 4 " RC P@1 . 1 7% 701A RIM=853.44 18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK Rev. #Revision Description Issue Date 1 ADDENDUM 7/9/2019 STORM SEWER PLAN STORM SEWER PROFILE ALIGNMENT 701-701A ALIGNMENT 704-702 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. GENERAL NOTES SCALE: 1" = 30' SCALE:HORZ.: 1"=30' VERT.: 1"=5' LEGEND Existing Grade New Grade Granular Backfill C507 PLAN & PROFILE (STORM) NOTE* INSTALL FULL DEPTH GRANULAR BACKFILL WHEN UTILITY IS WITHIN 5' OF PAVEMENT. 2 TAC COMMENTS 8/12/2019