HomeMy WebLinkAboutE100.2-- -S
S
SS
SS
S
S S
SSS
S
S
SS
S
S
SSSSSSSSSSS
SSS
S
SSSSSSS
SS
SS
SSS
SS
SS
SS
S
SSS
S
05
A303
03
A301
02
A302
02
A301
3
A304
01
A301
01
A305 04
A302
01
A302
04
A301
05
A305
2
A304
02
A305
A
10' -11 1/2"
A
10' -11 1/2"
B
10' -10 3/4"
A
10' -11 1/2"
A
10' -11 1/2"
A
10' -11 1/2"
A
10' -11 1/2"
A
10' -11 1/2"
A
10' -11 1/2"
A
10' -11 1/2"
A
10' -11 1/2"
04
A303
02
A303
4
A304
3 TO FIXTURE ABOVE4
4
43
3 3
3
3
3 3
3
3
3 3
3 4 3 4 3 4 TO FIXTURE ABOVE33
3
3 3
3
TO SWITCH BELOW
3 3
3 3
3 TO SWITCH ABOVE1
A307
2
A306
3
A306
1
A30610' - 8 3/4" 10' - 8 3/4"EQ.5' - 4" 5' - 4" EQ. A
9' -0"
A
10' -11 1/2"
02
A401
B
11' -0"
EQ.6' - 4" 6' - 4" EQ. EQ
EQ B
10' -10 3/4"
B
10' -10 3/4"
A
11' -0"
A
10' -11 1/2"
11' -0"
1
EQ. 8' - 0" EQ.1
A
10' -11 1/2"
A
10' -11 1/2"
1
5
5
5
1
1
1
1
6
6
7
4
2
2 2
7 7
8
9
10
10
11
8
10
4
TYP.
4
TYP.
4
TYP.
12
TYP.
12
TYP.
12
TYP.
4
1
TYP.
1
EQ. 6' - 4" 6' - 4" EQ.EQ.EQ. EQ. EQ EQ EQ
14
A. REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS.
B. ALL GRIDS ARE CENTERED IN ROOMS EACH DIRECTION UNLESS NOTED
OTHERWISE.
C. LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS CONTAIN NOT LESS
THAN 1/2 TILE WIDTH, UNLESS OTHERWISE INDICATED.
D. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL
CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC.,
UNLESS OTHERWISE INDICATED.
E. PAINT ALL EXPOSED GYPSUM WALLBOARD SURFACES UNLESS NOTED
OTHERWISE. REFER TO FINISH PLAN FOR COLORS.
F. ALL EXPOSED DUCTWORK, PIPING, CONDUITS ETC. SHALL BE PAINTED. COLOR
TO MATCH CEILING OR EXPOSED STRUCTURE UNLESS OTHERWISE NOTED.
G. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD CEILINGS AT 20'
MAXIMUM. VERIFY LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION.
H. COORDINATE REFLECTED CEILING PLAN WITH MECHANICAL, PLUMBING,
ELECTRICAL, AND LIFE SAFETY PLANS. PROVIDE COORDINATION DRAWINGS FOR
REVIEW PRIOR TO CEILING INSTALLATION.
I. LIGHT FIXTURES, SPRINKLER HEADS, HVAC SUPPLY AND RETURN GRILLES ARE
SHOWN FOR LOCATION ONLY. REFER TO MEP DRAWINGS FOR ADDITIONAL
INFORMATION
J. PROVIDE ACOUSTICAL CEILING HOLD-DOWN CLIPS IN VESTIBULES. IN ROOMS
WITH EXTERIOR ENTRANCE DOORS PROVIDE HOLD-DOWN CLIPS FOR 10' IN ALL
DIRECTION OF DOORWAY.
K. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF
PANELS REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED
ACCESS WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY LOCATIONS
WITH ARCHITECT PRIOR TO INSTALLATION.
GENERAL CEILING PLAN NOTES
CEILING LEGEND
2x2 LAY-IN CEILING GRID
4x4 LAY-IN CEILING GRID
GYPSUM BOARD CEILING OR
GYPSUM BOARD BULKHEAD
EXPOSED STRUCTURE
CEILING TAG
CEILING TYPE
CEILING HEIGHT
X
X
CEILING
110' - 11 1/2"6"6"
1/2" GYPSUM
CEILING.
2X4 WOOD BLOCKING
MOLDING PROFILE.
SIDE BEAM BOARD.
BEAM CAP.
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
AUTHOR
CHECKER
02/22/19
A401
FIRST FLOOR REFLECTED
CEILING PLAN
18012POMEROY RESIDENCESPRING MILL ROAD & 111TH STREETCARMEL, INDIANA 46032Joe Logan
JGB Custom Homes
317-538-0887
jlogan2086@aol.com
SCALE: 3/16" = 1'-0" 01 FIRST FLOOR REFLECTED CEILING PLAN
CEILING TYPES
TYPE DESCRIPTION
A 1/2" GYPSUM WALLBOARD HUNG TO UNDERSIDE OF STRUCTURE.
B TONGUE AND GROOVE WOOD CEILING ON 1/2" SHEATHING.
REFLECTED CEILING KEYNOTES
1 TIMBER BEAM.
2 CASED OPENING.
4 DECORATIVE FIXTURE CENTERED.
5 CATHERDRAL CEILING WITH GYPSUM WALLBOARD FINISH.
6 CATHERDRAL CEILING MATERIAL TO TURN DOWN VERTICAL SURFACE.
7 ARCHED CASED OPENING.
8 BARREL VAULT CEILING WITH DRYWALL FINISH. REFER TO SECTIONS.
9COFFERED CEILING BEAMS. REFER TO DETAIL.
10 CATHERDRAL CEILING MATERIAL TO TURN DOWN VERTICAL SURFACE.
11 CEILING OUTSIDE OF SCOPE. REFER TO KBD DRAWINGS.
12 LIGHT FIXTURE CENTERED OVER ISLAND. REFER TO KBD DRAWINGS.
13 DRYWALL BULKHEAD AROUND STRUCTURAL STEEL BEAMS.
14 WALL COVERING FINISH ON VAULTED CEILING TBD.
15 CRAWL ACCESS PANEL.
SCALE: 3" = 1'-0"02 CEILING DETAIL -CAUFFERED CEILING
#DESCRIPTION DATE
03/26/19
Adam Schriner