Loading...
HomeMy WebLinkAboutE100.2-- -S S SS SS S S S SSS S S SS S S SSSSSSSSSSS SSS S SSSSSSS SS SS SSS SS SS SS S SSS S 05 A303 03 A301 02 A302 02 A301 3 A304 01 A301 01 A305 04 A302 01 A302 04 A301 05 A305 2 A304 02 A305 A 10' -11 1/2" A 10' -11 1/2" B 10' -10 3/4" A 10' -11 1/2" A 10' -11 1/2" A 10' -11 1/2" A 10' -11 1/2" A 10' -11 1/2" A 10' -11 1/2" A 10' -11 1/2" A 10' -11 1/2" 04 A303 02 A303 4 A304 3 TO FIXTURE ABOVE4 4 43 3 3 3 3 3 3 3 3 3 3 3 4 3 4 3 4 TO FIXTURE ABOVE33 3 3 3 3 TO SWITCH BELOW 3 3 3 3 3 TO SWITCH ABOVE1 A307 2 A306 3 A306 1 A30610' - 8 3/4" 10' - 8 3/4"EQ.5' - 4" 5' - 4" EQ. A 9' -0" A 10' -11 1/2" 02 A401 B 11' -0" EQ.6' - 4" 6' - 4" EQ. EQ EQ B 10' -10 3/4" B 10' -10 3/4" A 11' -0" A 10' -11 1/2" 11' -0" 1 EQ. 8' - 0" EQ.1 A 10' -11 1/2" A 10' -11 1/2" 1 5 5 5 1 1 1 1 6 6 7 4 2 2 2 7 7 8 9 10 10 11 8 10 4 TYP. 4 TYP. 4 TYP. 12 TYP. 12 TYP. 12 TYP. 4 1 TYP. 1 EQ. 6' - 4" 6' - 4" EQ.EQ.EQ. EQ. EQ EQ EQ 14 A. REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS. B. ALL GRIDS ARE CENTERED IN ROOMS EACH DIRECTION UNLESS NOTED OTHERWISE. C. LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS CONTAIN NOT LESS THAN 1/2 TILE WIDTH, UNLESS OTHERWISE INDICATED. D. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE INDICATED. E. PAINT ALL EXPOSED GYPSUM WALLBOARD SURFACES UNLESS NOTED OTHERWISE. REFER TO FINISH PLAN FOR COLORS. F. ALL EXPOSED DUCTWORK, PIPING, CONDUITS ETC. SHALL BE PAINTED. COLOR TO MATCH CEILING OR EXPOSED STRUCTURE UNLESS OTHERWISE NOTED. G. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD CEILINGS AT 20' MAXIMUM. VERIFY LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. H. COORDINATE REFLECTED CEILING PLAN WITH MECHANICAL, PLUMBING, ELECTRICAL, AND LIFE SAFETY PLANS. PROVIDE COORDINATION DRAWINGS FOR REVIEW PRIOR TO CEILING INSTALLATION. I. LIGHT FIXTURES, SPRINKLER HEADS, HVAC SUPPLY AND RETURN GRILLES ARE SHOWN FOR LOCATION ONLY. REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION J. PROVIDE ACOUSTICAL CEILING HOLD-DOWN CLIPS IN VESTIBULES. IN ROOMS WITH EXTERIOR ENTRANCE DOORS PROVIDE HOLD-DOWN CLIPS FOR 10' IN ALL DIRECTION OF DOORWAY. K. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. GENERAL CEILING PLAN NOTES CEILING LEGEND 2x2 LAY-IN CEILING GRID 4x4 LAY-IN CEILING GRID GYPSUM BOARD CEILING OR GYPSUM BOARD BULKHEAD EXPOSED STRUCTURE CEILING TAG CEILING TYPE CEILING HEIGHT X X CEILING 110' - 11 1/2"6"6" 1/2" GYPSUM CEILING. 2X4 WOOD BLOCKING MOLDING PROFILE. SIDE BEAM BOARD. BEAM CAP. REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT AUTHOR CHECKER 02/22/19 A401 FIRST FLOOR REFLECTED CEILING PLAN 18012POMEROY RESIDENCESPRING MILL ROAD & 111TH STREETCARMEL, INDIANA 46032Joe Logan JGB Custom Homes 317-538-0887 jlogan2086@aol.com SCALE: 3/16" = 1'-0" 01 FIRST FLOOR REFLECTED CEILING PLAN CEILING TYPES TYPE DESCRIPTION A 1/2" GYPSUM WALLBOARD HUNG TO UNDERSIDE OF STRUCTURE. B TONGUE AND GROOVE WOOD CEILING ON 1/2" SHEATHING. REFLECTED CEILING KEYNOTES 1 TIMBER BEAM. 2 CASED OPENING. 4 DECORATIVE FIXTURE CENTERED. 5 CATHERDRAL CEILING WITH GYPSUM WALLBOARD FINISH. 6 CATHERDRAL CEILING MATERIAL TO TURN DOWN VERTICAL SURFACE. 7 ARCHED CASED OPENING. 8 BARREL VAULT CEILING WITH DRYWALL FINISH. REFER TO SECTIONS. 9COFFERED CEILING BEAMS. REFER TO DETAIL. 10 CATHERDRAL CEILING MATERIAL TO TURN DOWN VERTICAL SURFACE. 11 CEILING OUTSIDE OF SCOPE. REFER TO KBD DRAWINGS. 12 LIGHT FIXTURE CENTERED OVER ISLAND. REFER TO KBD DRAWINGS. 13 DRYWALL BULKHEAD AROUND STRUCTURAL STEEL BEAMS. 14 WALL COVERING FINISH ON VAULTED CEILING TBD. 15 CRAWL ACCESS PANEL. SCALE: 3" = 1'-0"02 CEILING DETAIL -CAUFFERED CEILING #DESCRIPTION DATE 03/26/19 Adam Schriner