HomeMy WebLinkAboutE200.1GFIGFI GFIGFIGFIGFIGFIRS S S SSS
SS
SS SSSS
SS
SS
SS SSS
SSSSS
S S
S
S
A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL
CONSTRUCTION DETAILS.
B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS.
C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE
APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT.
D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET
WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND
JANITOR CLOSETS.
E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES
AND THE LOBBY.
F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110.
GENERAL PLAN NOTES
GENERAL ELECTRICAL PLAN NOTES
A. ALL STANDARD OUTLETS TO BE LEVITRON 15 AMP USB CHARGER/TR DUPLEX
UNLESS OTHERWISE NOTED (T5632-W).
B. COORDINATE ALL OUTLETS NOTED FOR EQUIPMENT OR APPLIANCES WITH
CABINET/APPLIANCE SUPPLIER FOR EXACT LOCATION AND TYPE.
C. ALL OUTLETS NOTED FOR EQUIPMENT OR APPLIANCES TO BE DEDICATED CIRCUITS
UNLESS OTHERWISE NOTED.
2
2
84 5
5
5
10 10
1 1
1 1
2
1
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
Author
Checker
02/22/19
A152
SECOND FLOOR
ELECTRICAL LAYOUT PLAN
18012POMEROY RESIDENCESPRING MILL ROAD & 111TH STREETCARMEL, INDIANA 46032Joe Logan
JGB Custom Homes
317-538-0887
jlogan2086@aol.com
ELECTRICAL PLAN KEYNOTES
1 GFI OUTLET 42" TO CENTER A.F.F.
2 GFI OUTLET IN COUNTER TOP, COORDINATE WITH CABINET/COUNTERTOP
SUPPLIER
3 RANGE OUTLET, COORDINATE RECEPTACLE TYPE/LOCATION WITH CABINET
SUPPLIER.
4 MOUNT CENTER OF DEVICE AT 48" A.F.F.
5 MOUNT CENTER OF DEVICE AT 42" A.F.F.
6 RECEPTACLE MOUNTED IN SIDE OF CABINET, COORINATE LOCATION WITH
CABINET SUPPLIER.
7 UNDERCOUNTER JUNCTION BOX FOR DISHWASHER, COORDINATE LOCATION
WITH CABINET SUPPLIER.
8 DRYER RECEPTACLE, COORDINATE PLUG TYPE WITH CABINET SUPPLIER.
9 MOUNT CENTER OF DEVICE AT 84" A.F.F.
10 MOUNT EACH DEVICE WITHIN PHONE-CHARGING WALL CUBBY. COORIDINATE
HEIGHTS WITH TRIM CARPENTER.
11 MOUNT CENTER OF DEVICE AT 24" A.F.F.
12 MOUNT DEVICE UNDER COUNTER. COORDINATE WITH CABINET/COUNTERTOP
SUPPLIER.
13 UNDERCOUNTER DEVICE BOX FOR FRIDGE, COORDINATE LOCATION WITH
CABINET SUPPLIER.
14 UNDERCOUNTER DEVICE BOX FOR ICE MACHINE, COORDINATE LOCATION
WITH CABINET SUPPLIER.
SCALE: 3/16" = 1'-0" 01 SECOND FLOOR CONSTRUCTION PLAN
#DESCRIPTION DATE
03/26/19
Adam Schriner