HomeMy WebLinkAboutS001.2FOUNDATION PLAN NOTES 1. REF. S501 FOR STRUCTURAL NOTES, DESIGN DATA & SCHEDULES. 2. ALL CONTRACTORS ARE REQUIRED TO COORDINATE THEIR WORK WITH ALL DISCIPLINES TO AVOID CONFLICTS. THE MECHANICAL, ELECTRICAL, AND PLUMBING ASPECTS ARE NOT IN THE SCOPE OF THESE DRAWINGS. THEREFORE, ALL REQUIRED MATERIALS AND WORK MAY NOT BE INDICATED. 3. COORDINATE EXACT SIZE & LOCATION OF ALL MECHANICAL OPENINGS IN FOUNDATION WALLS WITH THE MECHANICAL, ELECTRICAL & PLUMBING CONTRACTORS. 4. ALL ELEVATIONSARE REFERENCED FROM THE FIRST FLOOR FINISH FLOOR ELEVATION +100'-0". REF. CIVIL DWGS. 5. REF. ARCH. DRAWINGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND IMMEDIATELY NOTIFY ARCH ITECTIENGINEER OF ANY DISCREPANCIES. 6. REF. S401 FORTY PICALFOUNDATION DETAILS. 7. NOTE: PERIMETERWALL AND COLUMN FOOTINGS SHALL BE LOWERED AND/OR SLEEVED TO PASS BELOW PLUMBING LINES (I.E. SANITARY& STORM SEWERS, WATER LINES, ETC.) SHOWN ON THE PLUMBING DRAWINGS. PROVIDE FOOTING STEPS AS REQUIRED PER THE TY PICALDETAILS ON S401. 8. ALL SLAB RECESSES SHALL BE LOCATED PER THE ARCHITECTURAL DRAWINGS. COORDINATE DEPTHS OF ALL SLAB RECESSES WITH THE ARCHITECTURAL DRAWINGS AND/OR THE FLOORING SUPPLIER. 9. COORDINATE REINFORCING DOWELS FOR CMU VERTICAL REINFORCING WITH REINF. NOTED ON PLANS & SECTIONS. 10. COLUMN FOOTINGS, TRENCH FOOTINGS AND WALL FOOTINGS SHALL BEAR ON APPROVED SOIL. UNDERCUT AS REQ'D TO SUITABLE BEARING MATERIAL AS DETERMINED BY THE GEOTECHNICAL TESTING AGENCY. REF. TYPICALFOOTING UNDERCUT DETAILX/SXXX. UNDERCUTTING TO SUITABLE BRG. MATERIAL IS NOT REQUIRED FOR GRADE BEAMS. REFERENCE ELEVATIONS IN PARENTHESES (-XX'-X") FOR APPROXIMATE ELEVATION TO SUITABLE BEARING STRATATO BE USE FOR BIDDING PURPOSES. 12. COLUMN FOOTINGS SUPPORTING MORE THAN ONE COLUMN SHALL BE CENTERED AT THE MIDPOINT BETWEEN THE COLUMNS, UNLESS NOTED OTHERWISE ON PLAN. 13. PROVIDE CONTROL/CONTRACTION JOINTS IN SLABS ON GRADE (REF. THE TYPICAL DETAILS ON SHEET S401). ALL JOINTS IN SLABS TO RECEIVE THIN OR THICK -SET TERRAllO, CERAMIC OR PORCELAIN TILE, VINYL -COMPOSITION TILE (VCT) OR VINYLSHEET GOODS, EPDXY OR SIMILAR THIN-FILM FINISH FLOORING SHALL BE CAREFULLY COORDINATED WITH THE FLOORING CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SLAB JOINT LAYOUTTO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO PLACING SLABS. 14.. COLUMN AND WALL FOOTINGS TO BEAR ON EX. LIMESTONE BEDROCK. EXTEND OR UNDERCUT AS REQ'D TO ACHIEVE MIN. BEARING CAPACITIES LISTED ON PLAN & CONFIRMED BY THE GEOTECHNICAL INSPECTING & TESTING AGENCY. REF. TYPICALFOOTING EXTENSION & UNDERCUT DETAILS FOR ADDITIONAL INFORMATION. REFER TO ROCK ELEVATION CONTOURS ON THE FOUNDATION PLAN FOR APPROXIMATE ELEVATIONS TO ROCK. ELEVATIONS SHOWN HAVE BEEN INTERPOLATED FROM THE SOILS REPORT& MAYBE USED FORBIDDING PURPOSES ONLY, ALL ROCK ELEVATIONS SHALL BE ESTABLISHED IN FIELD & CONFIRMED/RECORDED BY THE INSPECTION/TESTING AGENCY. 15. PLAN LEGEND: F.F. DENOTES FINISH FLOOR T/'X' DENOTES TOP OF FTG., GRADE BEAM, SLAB, PIER, ETC. B/'X' DENOTES BOTTOM OF FTG., GRADE BEAM, ETC. C.J. DENOTES SLAB ON GRADE CONTROL/CONTRACTION JOINT WF30-20'-0" DENOTES WALL FOOTING MARK & TOP OF FOOTING ELEVATION (SEE WALL FOOTING SCHEDULE) DENOTES COLUMN FOOTING MARK & TOP OF FTG. ELEVATION (SEE FTG. SCHED.) DENOTES COLUMN DENOTES PIER MARK & TOP OF PIER F5.0 4' 8'� ELEVATION (SEE PIER SCHED.) SIZE (REF. FRAMING � P24 -0'-8 PLANS FOR STUB HSS6x6x318 — — COLUMN FOOTING COL'S NOT ON FDNS) I CONCRETE PIER STEEL COLUMN I L_ _J �Q grssar RELEA$ D FOR CONSTRUCTION Su[I to compliance With aIIregulaiinns f State and Local Codes :Y "0 DATE: 03/22/19 Adam Schriner N 46'- 9" 1 S403 I r-_ NIS — — -- — — - I +99' - 0" — 1 I S403 I I 4" CONC. SLAB w/6x6 - W1.4xW1.4 WWF ON 6" COMPACTED GRANULAR FILL & 15 MIL VAPOR BARRIER TISLAB SLOPES TO O.H. DOORS I I +98'-9" I — — — — — — — — — — — — — — — — BID S403 a W O 10" CONC. WALL w/ #5 @ 12" O.C. EA. WAY. ON 2'-0" x 1'4" CONC. FTG. w/345 CONT. T/FTG. = +95-2 314" 10 S402 107' 11" 16'- 5" S402 01 3'-4112" 9'-8" 3'4 112" 01 S403 I -J L Jt— o N 5402 44'- 9" WALLS WITHOUT SHADING TO BE 10" CONC. WALL wl #5 @ 12" O.C. EA. WAY. ON 2'-0" x T-0" CONC. FTG. w/345 CONT. T/FTG. = +88'-2 314" ®EVa E�lw 2'-3„ I 22 o 8 s403 F L_--------- I I I INDICATES DIRECTION OF i r — — — — — — I I I I FLOOR JOIST FRAMING — — — TY P. I I 2 I I I S402 �I W12X26 I L-----------� L ------------- S4 02 S402 I I I I = 1 1 I Z4" XTERIORCONC.SLABw16x6-W1.4xW1.4 WWF ON 6" COMPACTED GRANULAR FILL TISLAB = +100'-0" 4" CONC. SLAB w/6x6 - W1.4xW1.4 WWF ON 6" CO APACTED GRANULAR FILL& 15 MIL VAPOR BARRIER / _ I I TISLAB=+88'-10314" 1 7 7 I I I I I S403 SIM. S403 5 I I I STEP FTG. 1'-0" S402 I I I 1 LJ I L------� W12X40 NJ T-2" x 2'-0" CONCRETE FOUNDATION PIERSw/ #5 @ 12" O.C. EA. WAY,EA. FACE ON 2'-6" x 3'-6" CONC. FTG. wl #5 @ 12" O.C. EA. WAY. T/FTG. = +91'-0" T/WALL= FIELD VERIFY 14" CONC. WALL w/#5 @ 12" O.C. EA. WAY., EA. FACE ON 2'-0" x T-0" CONC. FTG. wl345CONT. T/FTG. = +88'-2 314" I Z4% 12" CONC. WALL w/ #5 @ 10" O.C. EA.S402 I S403 �J WAY., EA. FACE ON 2'-0" x T-0" CONC. L — — J FTG.w13-#5CONT. 5 5 ��. I IW12 26 TIFTG. = +88'-2 314" 42'- 1" 2 S403 33'- 2" 1 S403 1' 11 3 4" N U, F_ ----- - --- L rJ +98'-911 1 I _ _ S403 I I r 2 14' 6114" S403 SIM. N � 1 _ - co 4" CONC. SLABw16x6 W1.4xW1.4 WWF ON I I' 3112" o N I I 6" COMPACTED GRANULAR FILL & 15 MIL VAPORBARRIER 1 L — TISLAB SLOPES TO O.H. DOORS L e F +99,411 oo L------ ------ ------- I S403 ---- - --------------J S402 l . N 8 S402 CONC. SLAB ON METAL DECK, SEE ECTIONS. C> M N 1 ol 9 � 4" CONC. SLAB w16x6 - W1.4xW1.4 WWF ON 6" COMPACTED GRANULAR r — — FILL & 15 MIL VAPOR BARRIER S402 I I TISLAB=+87'-103/4"I I r W12X26 I I I ❑ syel. 22 U L — J L — — JSTEP FTG. r J I 5'-0" x 5'-0" x T-0" CONC. FTG. S403 1 0 I 1 F 9 TY P. wl645 EA. WAY. I 4-0 _�_ 0 I TIFTG. = 88'-2 314" I I L— J I I M IW12X2 X Z4" CONC. SLAB w/6x6- W1.4xW1.4 WWF ON 6" COMPACTED i I GRANULAR FILL & 15 MIL VAPOR BARRIER 1 1 I TISLAB = +88'-10 314" 1 1 I 1 1'- 7 314" 7 J IS402 I --- — — — — — — — — — — — — — — — --------------- ----I N----- _- u? CV 1 NOTE: T P OF FINISHED FIRST FLOOR= +100'-0". M S402 I 35- 3 518" L, WALLS WITHOUT SHADING TO BE 10" CONC. WALL w/ #5 @ 12" 1 10" CONC. WALL w/ #5 @ 12" O.C. EA. WAY. EA. WAY. ON 2'-0" x T-0" CONC. FTG. w/345 CONT. S403 ON 2'-0" x T-0" CONC. FTG. w1345 CONT. TIFTG. = +88'-2 314" TIFTG. = +96'-1" TYP.AROUND GRADE 33'- 2" 26'- 6" 6'-7114" 1 14'-9114" FOUNDATION PLAN 1/8" = 1'-011 45- 7114" 162'- 5" NOTE: WIDEN FOOTINGS AND - WALLS TO ACCOMODATE LIMESTONE VENEER AND PIERS. T-0 4 S402 50'-0" 30'- 61/2" 1 I I 6 SHADING DENOTES 12" CONC. WALL w/#5@ 12" O.C. EA. WAY.ON 2'0"x S402 T-0" CONC. FTG. w/345 CONT. TIFTG. = +94'-2 314" 4'- 7 718" 6' - 2 /4" 19'- 7 718" WALLS WITHOUT SHADING TO BE 10" CONC. WALL wl 10 S402 ON 2'-0" x 1' 0" CONC. FTG. w/345 CONT. S402 — T/FTG. _ +94'-2 314" --� L-------- -- --_JL------- -- -� 2 s402 I I N I I I � I Z CRAWLSPACEAREA MIN. 4" PEA GRAVEL 1 LI? 3 I OVER 15 MIL VAPOR 1 S402 BARRIER I I I I FTS J + 0 + 2 J 20 I I S402 L-- 13' - 9 7/8" 20'- 9" 1 CONC. PIERS& FOOTINGS, 1 REFERENCE SECTION 3/S403 16'- 7 3/8" 20'- 21/4" 3 I 1 2 PROVIDE PRECAST LINTELS TO S402 1 I S402 SPAN BETWEEN FOOTINGS _ ____ `� o CV _ _ L -1 FL I SEE ARCHITECTURAL - N O M r _ _ C;, r J I DRAWINGS FOR SCREEN WALL 71DIMENSIONS. — — L----- r— —-- — ----� 9 FOUNDATION FOR SCREEN I 2' 1" 101-01, 13' - 9" 4' - 6" 4' - 0" S403 WALL, SEE SECTION. 1 zEn J 01 _ — SEE ARCHITECTURAL FLOOR PLAN FOR ALL PLAN DIMENSIONS. SHADING DENOTES 12" CONC. WALL w/ #5 @ 12" O.C. EA. WAY. ON 2'-0" x T-0" CONC. FTG. w/345 CONT. SHADING DENOTES 12" CONC. WALL wl #5 @ 12" O.C. T/FTG. = +94'-2 314" EA. WAY. ON 2'-0" x 1'-0" CONC. FTG. wl345 CONT. TIFTG. = +94'-2 314" COMPACTED GRANULAR FILL UNDER SLAB - 0 318" 30'- 4" 618 East MarketStreet Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c In. c o m Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. DRAWNBY NHF CHECKEDBY WBH DATE ISSUED 02/09/19 REVISIONS: # DESCRIPTION DATE CLIENT POMEROY LU LU W 10:� V V„ CV Z CD W ~ -'O r- Q 0 z IX W Q Q W Q Q Oz 0 0 �J J LU ICL W J ]�i o Q 0 zu Z CL 10:� IL Cn ```>>��1t1111//IIII � : •* G1ST E/lEO •• •t�O iii PE60860410 — STATE OF • I • � � i I� O� ••• ,'NDI ANP •••�• ��r``� NAL Alle FOUNDATION PLAN S201 PROJECT NUMBER: 18012