HomeMy WebLinkAboutS100.5FIRST FLOOR
100' - 0"
ROOF PLAN
122' - 10"
SECOND FLOOR
112' - 0"
CEILING
110' - 11 1/2"
GARAGE LEVEL
99' - 0"
ROOF 3
121' - 10"
ROOF 4
114' - 0"
ROOF 7
120' - 9"
ROOF 8
119' - 9"3' - 0" VARIES8' - 0"3' - 0" RIGID INSULATION -R15 MIN.
@ FOUNDATION/SLAB PERIMETER FOR
LENGTH OF 24" VERTICALLY AND
HORIZONTALLY.
VAPOR BARRIER @ HORIZONTAL
AND VERTICAL FACE OF
CONCRETE SLAB.
PERFORATED DRAINAGE TILE @
PERIMETER CONCRETE FOOTING.
CONCRETE FOOTING -REFER TO
STRUCTURAL DWGS.
FOUNDATION DAMPROOFING.
COMPACTED GRANULAR FILL.
CONCRETE FOUNDATION WALL.
DRAINAGE MAT @ FOUNDATION
PERIMETER.
P.T. WOOD SILL PLATE
PROVIDE METAL J-TRIM
ACCESSORY @ BOTTOM
OF GYPSUM WALL. (3) COURSES LIMESTONE
@ WALL BASE.4" MIN. CONCRETE SLAB
ON COMPACTED
GRANULAR FILL.
ASPHALT ROOF SHINGLES.
WOOD ROOF FRAMING -
COORDINATE WITH FRAMER.
1/2" ROOF SHEATHING.
PROVIDE DRIP EDGE ALONG
EAVES.
1X4 WOOD FASCIA. INSTALL WOOD BLOCKING
AND 1X SOFFIT BOARD.
GLAZING -REFER TO WINDOW
SCHEDULE.
GLAZING -REFER TO WINDOW
SCHEDULE.
5/8" GYPSUM CEILING.
R-38 MIN. ROOF
INSULATION.
ASPHALT ROOF SHINGLES.
1/2" ROOF SHEATHING.
PROVIDE DRIP EDGE ALONG
EAVES.
1X4 WOOD FASCIA. INSTALL WOOD BLOCKING
AND 1X SOFFIT BOARD.
EIFS WALL FINISH.
EIFS WALL FINISH.
EIFS WALL FINISH.
EIFS WINDOW SILL.
VENT BAFFLE -LOCATED IN AREA
DESIGNATED FOR PASSIVE ROOF
VENTILATION ONLY. REFER TO
ROOF PLAN.
FIRST FLOOR
100' - 0"
SECOND FLOOR
112' - 0"
CEILING
110' - 11 1/2"
GARAGE LEVEL
99' - 0"
EXPANSION MATERIAL AND
SEALANT JOINT.
4" MIN. CONCRETE SLAB
ON COMPACTED
GRANULAR FILL.
RIGID INSULATION -R15 MIN.
@ FOUNDATION/SLAB PERIMETER FOR
LENGTH OF 24" VERTICALLY AND
HORIZONTALLY.
VAPOR BARRIER @ HORIZONTAL
AND VERTICAL FACE OF
CONCRETE SLAB.
PERFORATED DRAINAGE TILE @
PERIMETER CONCRETE FOOTING.
CONCRETE FOOTING -REFER TO
STRUCTURAL DWGS.
FOUNDATION DAMPROOFING.
COMPACTED GRANULAR FILL.
CONCRETE FOUNDATION WALL.
DRAINAGE MAT @ FOUNDATION
PERIMETER.
1/2" RECESS IN CONCRETE SLAB
-COORDINATE WITH OVERHEAD
DOOR.
OVERHEAD DOOR.
SLOPED CONCRETE APRON,
ALIGN WITH ASPHALT PAVING.
SLOPE
EIFS WALL FINISH TO
WRAP DOOR OPENING.
WOOD HEADER -COORDINATE
TO MEET SPANNING REQUIREMENTS
AND ANCHORAGE FOR STONE
ACCENT TRIM.
ASPHALT ROOF SHINGLES.
1/2" ROOF SHEATHING.
PROVIDE DRIP EDGE ALONG
EAVES.
1X4 WOOD FASCIA. INSTALL WOOD BLOCKING
AND 1X SOFFIT BOARD.
EIFS WALL FINISH.
5/8" GYPSUM CEILING.
R-38 MIN. ROOF
INSULATION.
WOOD ROOF FRAMING -
COORDINATE WITH FRAMER.
2X6 WOOD WALL
FRAMING.
R-21 BATT INSULATION.
1/2" GYPSUM
WALLBOARD.
FRAMED ARCHWAY WITH
STUCCO WALL FINISH.
VENT BAFFLE -LOCATED IN AREA
DESIGNATED FOR PASSIVE ROOF
VENTILATION ONLY. REFER TO
ROOF PLAN.
FIRST FLOOR
100' - 0"
SECOND FLOOR
112' - 0"
CEILING
110' - 11 1/2"
GARAGE LEVEL
99' - 0"
ROOF 4
114' - 0"
ASPHALT ROOF SHINGLES.
1/2" ROOF SHEATHING.
PROVIDE DRIP EDGE ALONG
EAVES.
1X4 WOOD FASCIA. INSTALL WOOD BLOCKING
AND 1X SOFFIT BOARD.
WOOD ROOF FRAMING -
COORDINATE WITH FRAMER.
2' - 2"
WOOD HEADER.
FRAMED ARCHWAY WITH
STUCCO WALL FINISH.
3/4" T+G WOOD
SOFFIT.
STUCCO WALL FINISH.
ASPHALT PAVING -REFER TO SITE PLAN.
FIRST FLOOR
100' - 0"
ROOF PLAN
122' - 10"
SECOND FLOOR
112' - 0"
CEILING
110' - 11 1/2"
GARAGE LEVEL
99' - 0"
ASPHALT ROOF SHINGLES.
WOOD ROOF FRAMING -
COORDINATE WITH FRAMER
1/2" ROOF SHEATHING.
PROVIDE DRIP EDGE ALONG EAVES.
1X4 WOOD FASCIA.
INSTALL WOOD BLOCKING
AND 1X SOFFIT BOARD.
CONTINUOUS RIDGE VENT.
WATER RESISTANT BARRIER.
EIFS WALL FINISH.
1/2" SHEATHING.
2X6 WOOD WALL FRAMING.
R-21 BATT INSULATION.
5/8" GYPSUM CEILING.
R-38 MIN. ROOF
INSULATION.
GABLE WOOD TRUSS.
EXPANSION MATERIAL AND SEALANT
JOINT.
P.T. WOOD SILL PLATE
PROVIDE METAL J-TRIM
ACCESSORY @ BOTTOM
OF GYPSUM WALL.(3) COURSES LIMESTONE
@ WALL BASE.
4" MIN. CONCRETE SLAB
ON COMPACTED
GRANULAR FILL.
RIGID INSULATION -R15 MIN.
@ FOUNDATION/SLAB PERIMETER FOR
LENGTH OF 24" VERTICALLY AND
HORIZONTALLY.
VAPOR BARRIER @ HORIZONTAL
AND VERTICAL FACE OF
CONCRETE SLAB.
PERFORATED DRAINAGE TILE @
PERIMETER CONCRETE FOOTING.
CONCRETE FOOTING -REFER TO
STRUCTURAL DWGS.
FOUNDATION DAMPROOFING.
COMPACTED GRANULAR FILL.
CONCRETE FOUNDATION WALL.
DRAINAGE MAT @ FOUNDATION
PERIMETER.
1/2" GYPSUM WALLBOARD.
FIRST FLOOR
100' - 0"
ROOF PLAN
122' - 10"
SECOND FLOOR
112' - 0"
CEILING
110' - 11 1/2"
GARAGE LEVEL
99' - 0"
2' - 7" OVERHANG
RIGID INSULATION -R15 MIN.
@ FOUNDATION/SLAB PERIMETER FOR
LENGTH OF 24" VERTICALLY AND
HORIZONTALLY.
VAPOR BARRIER @ HORIZONTAL
AND VERTICAL FACE OF
CONCRETE SLAB.
PERFORATED DRAINAGE TILE @
PERIMETER CONCRETE FOOTING.
CONCRETE FOOTING -REFER TO
STRUCTURAL DWGS.
FOUNDATION DAMPROOFING.
COMPACTED GRANULAR FILL.
CONCRETE FOUNDATION WALL.
DRAINAGE MAT @ FOUNDATION
PERIMETER.
ASPHALT PAVING -REFER TO SITE PLAN.
EXPANSION MATERIAL AND SEALANT
JOINT.
WATER RESISTANT BARRIER.
2X6 WOOD WALL FRAMING.
R-21 BATT INSULATION.
1/2" GYPSUM WALLBOARD.
5/8" GYPSUM CEILING.
EIFS WALL FINISH.
1/2" SHEATHING.
ASPHALT ROOF SHINGLES.
WOOD ROOF FRAMING -COORDINATE
WITH FRAMER.
R-38 MIN. ROOF
INSULATION.
1/2" ROOF SHEATHING.
PROVIDE DRIP EDGE ALONG
EAVES.
1X4 WOOD FASCIA. INSTALL WOOD BLOCKING
AND 1X SOFFIT BOARD.
3/4" T+G WOOD
SOFFIT.
CONTINUOUS RIDGE VENT.
1 HOUR FIRE RATED SEPARATION WALL
BETWEEN GARAGE AND HOUSE.
PROVIDE 5/8" GYSPUM BOARD ON
EACH SIDE, TAPE ALL SEAMS, COAT ALL
FASTENERS.
WATER RESISTANT BARRIER.
EIFS WALL FINISH.
1/2" SHEATHING.
ASPHALT ROOF SHINGLES.
1/2" ROOF SHEATHING.
WOOD ROOF FRAMING -
COORDINATE WITH FRAMER.
PROVIDE FLASHING @ ROOF TO
WALL INTERSECTION.
GABLE WOOD TRUSS.
PROVIDE CONTROL JOINT IN
SOFFIT BETWEEN GARAGE AND
PORTE COCHERE FRAMING.
P.T. WOOD SILL PLATE
PROVIDE METAL J-TRIM
ACCESSORY @ BOTTOM
OF GYPSUM WALL.
(3) COURSES LIMESTONE
@ WALL BASE.
4" MIN. CONCRETE SLAB
ON COMPACTED
GRANULAR FILL.
REVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
Author
Checker
02/22/19
A305
WALL SECTIONS
18012POMEROY RESIDENCESPRING MILL ROAD & 111TH STREETCARMEL, INDIANA 46032Joe Logan
JGB Custom Homes
317-538-0887
jlogan2086@aol.com
SCALE: 1/2" = 1'-0" 05 WS -GARAGE DORMER
SCALE: 1/2" = 1'-0" 02 WS -OVERHEAD GARAGE DOOR
SCALE: 1/2" = 1'-0"01 WS -PORTE COCHERE
SCALE: 1/2" = 1'-0" 03 WS -EAST GARAGE WALL
SCALE: 1/2" = 1'-0" 04 WS -GARAGE PORTE COCHERE
KIT OF PARTS
#DESCRIPTION DATE
03/22/19
Adam Schriner