HomeMy WebLinkAboutS100.5FIRST FLOOR 100' - 0" ROOF PLAN 122' - 10" SECOND FLOOR 112' - 0" CEILING 110' - 11 1/2" GARAGE LEVEL 99' - 0" ROOF 3 121' - 10" ROOF 4 114' - 0" ROOF 7 120' - 9" ROOF 8 119' - 9"3' - 0" VARIES8' - 0"3' - 0" RIGID INSULATION -R15 MIN. @ FOUNDATION/SLAB PERIMETER FOR LENGTH OF 24" VERTICALLY AND HORIZONTALLY. VAPOR BARRIER @ HORIZONTAL AND VERTICAL FACE OF CONCRETE SLAB. PERFORATED DRAINAGE TILE @ PERIMETER CONCRETE FOOTING. CONCRETE FOOTING -REFER TO STRUCTURAL DWGS. FOUNDATION DAMPROOFING. COMPACTED GRANULAR FILL. CONCRETE FOUNDATION WALL. DRAINAGE MAT @ FOUNDATION PERIMETER. P.T. WOOD SILL PLATE PROVIDE METAL J-TRIM ACCESSORY @ BOTTOM OF GYPSUM WALL. (3) COURSES LIMESTONE @ WALL BASE.4" MIN. CONCRETE SLAB ON COMPACTED GRANULAR FILL. ASPHALT ROOF SHINGLES. WOOD ROOF FRAMING - COORDINATE WITH FRAMER. 1/2" ROOF SHEATHING. PROVIDE DRIP EDGE ALONG EAVES. 1X4 WOOD FASCIA. INSTALL WOOD BLOCKING AND 1X SOFFIT BOARD. GLAZING -REFER TO WINDOW SCHEDULE. GLAZING -REFER TO WINDOW SCHEDULE. 5/8" GYPSUM CEILING. R-38 MIN. ROOF INSULATION. ASPHALT ROOF SHINGLES. 1/2" ROOF SHEATHING. PROVIDE DRIP EDGE ALONG EAVES. 1X4 WOOD FASCIA. INSTALL WOOD BLOCKING AND 1X SOFFIT BOARD. EIFS WALL FINISH. EIFS WALL FINISH. EIFS WALL FINISH. EIFS WINDOW SILL. VENT BAFFLE -LOCATED IN AREA DESIGNATED FOR PASSIVE ROOF VENTILATION ONLY. REFER TO ROOF PLAN. FIRST FLOOR 100' - 0" SECOND FLOOR 112' - 0" CEILING 110' - 11 1/2" GARAGE LEVEL 99' - 0" EXPANSION MATERIAL AND SEALANT JOINT. 4" MIN. CONCRETE SLAB ON COMPACTED GRANULAR FILL. RIGID INSULATION -R15 MIN. @ FOUNDATION/SLAB PERIMETER FOR LENGTH OF 24" VERTICALLY AND HORIZONTALLY. VAPOR BARRIER @ HORIZONTAL AND VERTICAL FACE OF CONCRETE SLAB. PERFORATED DRAINAGE TILE @ PERIMETER CONCRETE FOOTING. CONCRETE FOOTING -REFER TO STRUCTURAL DWGS. FOUNDATION DAMPROOFING. COMPACTED GRANULAR FILL. CONCRETE FOUNDATION WALL. DRAINAGE MAT @ FOUNDATION PERIMETER. 1/2" RECESS IN CONCRETE SLAB -COORDINATE WITH OVERHEAD DOOR. OVERHEAD DOOR. SLOPED CONCRETE APRON, ALIGN WITH ASPHALT PAVING. SLOPE EIFS WALL FINISH TO WRAP DOOR OPENING. WOOD HEADER -COORDINATE TO MEET SPANNING REQUIREMENTS AND ANCHORAGE FOR STONE ACCENT TRIM. ASPHALT ROOF SHINGLES. 1/2" ROOF SHEATHING. PROVIDE DRIP EDGE ALONG EAVES. 1X4 WOOD FASCIA. INSTALL WOOD BLOCKING AND 1X SOFFIT BOARD. EIFS WALL FINISH. 5/8" GYPSUM CEILING. R-38 MIN. ROOF INSULATION. WOOD ROOF FRAMING - COORDINATE WITH FRAMER. 2X6 WOOD WALL FRAMING. R-21 BATT INSULATION. 1/2" GYPSUM WALLBOARD. FRAMED ARCHWAY WITH STUCCO WALL FINISH. VENT BAFFLE -LOCATED IN AREA DESIGNATED FOR PASSIVE ROOF VENTILATION ONLY. REFER TO ROOF PLAN. FIRST FLOOR 100' - 0" SECOND FLOOR 112' - 0" CEILING 110' - 11 1/2" GARAGE LEVEL 99' - 0" ROOF 4 114' - 0" ASPHALT ROOF SHINGLES. 1/2" ROOF SHEATHING. PROVIDE DRIP EDGE ALONG EAVES. 1X4 WOOD FASCIA. INSTALL WOOD BLOCKING AND 1X SOFFIT BOARD. WOOD ROOF FRAMING - COORDINATE WITH FRAMER. 2' - 2" WOOD HEADER. FRAMED ARCHWAY WITH STUCCO WALL FINISH. 3/4" T+G WOOD SOFFIT. STUCCO WALL FINISH. ASPHALT PAVING -REFER TO SITE PLAN. FIRST FLOOR 100' - 0" ROOF PLAN 122' - 10" SECOND FLOOR 112' - 0" CEILING 110' - 11 1/2" GARAGE LEVEL 99' - 0" ASPHALT ROOF SHINGLES. WOOD ROOF FRAMING - COORDINATE WITH FRAMER 1/2" ROOF SHEATHING. PROVIDE DRIP EDGE ALONG EAVES. 1X4 WOOD FASCIA. INSTALL WOOD BLOCKING AND 1X SOFFIT BOARD. CONTINUOUS RIDGE VENT. WATER RESISTANT BARRIER. EIFS WALL FINISH. 1/2" SHEATHING. 2X6 WOOD WALL FRAMING. R-21 BATT INSULATION. 5/8" GYPSUM CEILING. R-38 MIN. ROOF INSULATION. GABLE WOOD TRUSS. EXPANSION MATERIAL AND SEALANT JOINT. P.T. WOOD SILL PLATE PROVIDE METAL J-TRIM ACCESSORY @ BOTTOM OF GYPSUM WALL.(3) COURSES LIMESTONE @ WALL BASE. 4" MIN. CONCRETE SLAB ON COMPACTED GRANULAR FILL. RIGID INSULATION -R15 MIN. @ FOUNDATION/SLAB PERIMETER FOR LENGTH OF 24" VERTICALLY AND HORIZONTALLY. VAPOR BARRIER @ HORIZONTAL AND VERTICAL FACE OF CONCRETE SLAB. PERFORATED DRAINAGE TILE @ PERIMETER CONCRETE FOOTING. CONCRETE FOOTING -REFER TO STRUCTURAL DWGS. FOUNDATION DAMPROOFING. COMPACTED GRANULAR FILL. CONCRETE FOUNDATION WALL. DRAINAGE MAT @ FOUNDATION PERIMETER. 1/2" GYPSUM WALLBOARD. FIRST FLOOR 100' - 0" ROOF PLAN 122' - 10" SECOND FLOOR 112' - 0" CEILING 110' - 11 1/2" GARAGE LEVEL 99' - 0" 2' - 7" OVERHANG RIGID INSULATION -R15 MIN. @ FOUNDATION/SLAB PERIMETER FOR LENGTH OF 24" VERTICALLY AND HORIZONTALLY. VAPOR BARRIER @ HORIZONTAL AND VERTICAL FACE OF CONCRETE SLAB. PERFORATED DRAINAGE TILE @ PERIMETER CONCRETE FOOTING. CONCRETE FOOTING -REFER TO STRUCTURAL DWGS. FOUNDATION DAMPROOFING. COMPACTED GRANULAR FILL. CONCRETE FOUNDATION WALL. DRAINAGE MAT @ FOUNDATION PERIMETER. ASPHALT PAVING -REFER TO SITE PLAN. EXPANSION MATERIAL AND SEALANT JOINT. WATER RESISTANT BARRIER. 2X6 WOOD WALL FRAMING. R-21 BATT INSULATION. 1/2" GYPSUM WALLBOARD. 5/8" GYPSUM CEILING. EIFS WALL FINISH. 1/2" SHEATHING. ASPHALT ROOF SHINGLES. WOOD ROOF FRAMING -COORDINATE WITH FRAMER. R-38 MIN. ROOF INSULATION. 1/2" ROOF SHEATHING. PROVIDE DRIP EDGE ALONG EAVES. 1X4 WOOD FASCIA. INSTALL WOOD BLOCKING AND 1X SOFFIT BOARD. 3/4" T+G WOOD SOFFIT. CONTINUOUS RIDGE VENT. 1 HOUR FIRE RATED SEPARATION WALL BETWEEN GARAGE AND HOUSE. PROVIDE 5/8" GYSPUM BOARD ON EACH SIDE, TAPE ALL SEAMS, COAT ALL FASTENERS. WATER RESISTANT BARRIER. EIFS WALL FINISH. 1/2" SHEATHING. ASPHALT ROOF SHINGLES. 1/2" ROOF SHEATHING. WOOD ROOF FRAMING - COORDINATE WITH FRAMER. PROVIDE FLASHING @ ROOF TO WALL INTERSECTION. GABLE WOOD TRUSS. PROVIDE CONTROL JOINT IN SOFFIT BETWEEN GARAGE AND PORTE COCHERE FRAMING. P.T. WOOD SILL PLATE PROVIDE METAL J-TRIM ACCESSORY @ BOTTOM OF GYPSUM WALL. (3) COURSES LIMESTONE @ WALL BASE. 4" MIN. CONCRETE SLAB ON COMPACTED GRANULAR FILL. REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT Author Checker 02/22/19 A305 WALL SECTIONS 18012POMEROY RESIDENCESPRING MILL ROAD & 111TH STREETCARMEL, INDIANA 46032Joe Logan JGB Custom Homes 317-538-0887 jlogan2086@aol.com SCALE: 1/2" = 1'-0" 05 WS -GARAGE DORMER SCALE: 1/2" = 1'-0" 02 WS -OVERHEAD GARAGE DOOR SCALE: 1/2" = 1'-0"01 WS -PORTE COCHERE SCALE: 1/2" = 1'-0" 03 WS -EAST GARAGE WALL SCALE: 1/2" = 1'-0" 04 WS -GARAGE PORTE COCHERE KIT OF PARTS #DESCRIPTION DATE 03/22/19 Adam Schriner