HomeMy WebLinkAboutElectrical E0.1ABBREVIATIONS A AMR AMPERES AM AMERICANS WITH DISABILITIES ACT AFC ABOVE FINISHED CEILING ARE ABOVE FINISHED FLOOR AEG ABOVE FINISHED GRADE ANSI AMERICAN NA IL STANDARDS INSTITUTE ARCH ARCHITECT, ARCHITECTURAL AUX AUXILIARY AWG AMERICAN WIRE GAUGE AN AUDIONISUAL US BUILDING AUTOMATION SYSTEM BKR BREAKER BLOC BUILDING BMS BUILDINGMANAGEMENTSYSTEM C CONDUIT CAN CABLE TELEVISION SYSTEM CR CIRCUIT BREAKER CCN CLOSED CIRCUIT TELEVISION GEM CUBIC FEET PER MINUTE CRT CIRCUIT CLG CEILING Cr CURRENT TRANSFORMER CW COLD WATER D DEEP, DEPTH DACT DIGITAL ALARM COMMUNICATING TRANSMITTER dB DECIBEL DOC DIRECT DIGITAL CONTROL A DELTA DIA DIAMETER DISC DISCONNECT ON DOWN DWG DRAWING EC ELECTRICAL CONTRACTOR EF EXHAUSTEAN ETR EXISTING TO REMAIN ME ELECTRICAL METALLIC TUBING EWC ELECTRICAL WATER COOLER EXH EXHAUST EX, EXIST EXISTING FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FAM FIRE ALARM REMOTE ANNUNCIATOR FLA FULLLOADAMPS FPC FIRE PROTECTION CONTRACTOR FT FOOT, FEET GGRD GROUND GC GENERAL CONTRACTOR GFI, GFCI GROUND FAULT INTERRUPTER HID HIGH INTENSITY DISCHARGE HTR HEATER HVAC HEATING, VENTILATING&A1C IBC INTERNATIONAL BUILDING CODE IN INCH, INCHES WA KILOVOLT -AMPS KW KILOWATTS KWH KILOWATT-HOUR L LENGTH LED LIGHT EMITTING DIODE URA LOCKEDROTORAMPS LTG LIGHTING MAX MAXIMUM MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY NICE MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MECH MECHANICAL MH METALHALIDE MIN MINIMUM MOCP MAXIMUM OVER CURRENT PROTECTION MUA MAKE LEAIR NATO MOUNTED NIA NOTAPPLICABLE N.C. NORMALLYCLOSED NEC NATIONAL ELECTRICAL CODE NEW NATIONAL ELECTRICAL MFR'S ASSOC. NFPA NATIONAL FIRE PROTECTION ASSOC. NIC NOT IN CONTRACT N.O. NORMALLYOPEN TUTS NOTTOSCALE OC ON CENTER OM OVERHEAD OSHA OCCUPATIONAL SAFETY&HEALTH ADMIN. P POLE PB PUSHBUTTON PC PLUMBING CONTRACTOR PF POWER FACTOR PH PHASE PVC POLYVINYLCHLORIDE RCP REFLECTED CEILING PLAN REV REVISION REX REMOVEEXISTING RGS RIGID GALVANIZED STEEL REA RUNNINGLOADAMPS RM ROOM RR REMOVE AND RELOCATE AN ROOFTOP UNIT BE SERVICE ENTRANCE SF SQUARE FEET, SQUARE FOOT TIC TIMECLOCK THEM THROUGH TRANS TRANSFORMER TYP TYPICAL UG UNDERGROUND UL UNDERWRITERS LABORATORIES, INC. LION UNLESS OTHERWISE NOTED UPS UNINTERRUPTED POWER SUPPLY VA VOLT-AMPERE W WATT, WIDTH WI WITH WP WEATHERPROOF XFMR TRANSFORMER Y WYE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�12'�B*VAWML DATE: \ 08/15/19 ELECTRICAL SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) 1,3,5 HOMERUN TO PANEL"A", CIRCUIT #1,3,5 NIA 20A-1 P CIRCUIT BREAKERS), TWO#12 A CONDUCTORS (MINIMUM SIZE), UON. A GROUNDING CONDUCTOR SHALL BE PROVIDED IN ALL CONDUITS. REFER TO SPECIFICATIONS FOR ADDITIONAL GROUNDING REQUIREMENTS. ---- INFLOORIINDERFLOOR CONDUITMIRE CIRCUITRYTURNINGUP G PANELBOARD - 208YI12OV-304W PANELBOARD - MOY12TTV-304W ® DRY TYPE TRANSFORMER, REFER TO PLANS FOR SRENOLTAGE. QJ 4 JUNCTION BOX- CEILING OR WALL MOUNTED. ❑1 DISCONNECT SWITCH UNFUSED:"AS"- INDICATES SWITCH SIZE (AMPS). �1 DISCONNECT SWITCH FUSED: "AS- INDICATES SWITCH SEE (AMPS). "AF"- INDICATES FUSE SIZE (AMPS). I� COMBINATION MOTOR STARTERIDISCONNECT SWITCH MOTOR (p DUPLEX RECEPTACLE -12S/, 20A, MOUNTED AT 1T AFF UNLESS OTHERWISE ft NOTED. "O INDICATES CONTROLLED RECEPTACLE vSV INDICATES SV ARE "BOP INDICATES WEATHERPROOF COVER "IG" INDICATES ISOLATED GROUND TYPE m CONTROLLED WPLEX RECEPTACLE- 125V, 20A, MOUNTED AT I T AFF tt UNLESS OTHERWISE NOTED. IT GECIDUPLEX-125V,20A, MOUNTED AT I S ARE UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLE PROTECTED VIA GFCI BREAKER, PROVIDE LABELING AS REQUIRED BY NEC-125V, 20A, MOUNTED AT WARE UNLESS OTHERWISE NOTED. DUPLEX ABOVE COUNTER- 125V, 20A, MOUNTED AT T ABOVE COUNTER li UNLESS OTHERWISE NOTED. m CON TROLLED DUPLEX RECEPTACLE ABOVE COUNTER- 125/, 20A, MOUNTED li AT T ABOVE COUNTER UNLESS OTHERWISE NOTED. GFCI DUPLEX ABOVE COUNTER- 125V, 20A, MOUNTED AT S" ABOVE tt COUNTER UNLESS OTHERWISE NOTED. DUPLEX ABOVE COUNTER PROTECTED VIA GFCI BREAKER PROVIDE LABELING AS REQUIRED BY NEC-125V, 23A, MOUNTED AT 8" ABOVE COUNTER UNLESS OTHERWISE NOTED. DOUBLE DUPLEX RECEPTACLE- 125V, 20A, MOUNTED AT I8"AFF UNLESS OTHERWISE NOTED. SPECIAL PURPOSE RECEPTACLE, TYPE AND MOUNTING AS INDICATED ON THE DRAWINGS. ® DUPLEX RECEPTACLE-125V, 20A, MOUNTED IN CEILING. ® DOUBLE DUPLEX RECEPTACLE- 125V, 20A, MOUNTED IN CEILING. ® DUPLEX RECEPTACLE-125V, 20A, MOUNTED IN FLOOR BOX. ® DOUBLEDUPLEXPECEPTACLE- 125V, 20A, MOUNTED IN FLOOR BOX. COMBINATION DUPLEX RECEPTACLE AND VOICEDATA OUTLET MOUNTED IN FLOORBOX. FIRE RATED POKE -THROUGH DEVICE DUPLEX RECEPTACLE-125V, 20A. •p COMBINATION DUPLEX RECEPTACLE AND VOICEDATA POKE -THROUGH DEVICE DUPLEX RECEPTACLE. RANGE RECEPTACLE, REFER TO PLANS FOR TYPE AND AMPERAGE. SWITCH- SINGLE POLE TOGGLE TYPE -120I277V, 20A, 1-HP RATED, MOUNTED AT 49' ME UNLESS OTHERWISE NOTED. "3" INDICATES THREE WAY SWITCH W INDICATES FOUR WAY SWITCH T" INDICATES SWITCH MOUNTED Si COUNTER "a" INDICATES SWITCHED FIXTURE CONTROL "OS" INDICATES DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH "D" INDICATES DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR O$ OCCUPANCY SENSOR- DUAL TECHNOLOGY, CEILING MOUNTED © PHOTOCELLSENSOR- MAL TECHNOLOGY, CEILING MOUNTED �13 LIGHT FIXTURE:"A" INDICATES FIXTURE TYPE,"1 T INDICATES CIRCUIT NUMBER, 'a' a INDICATES SWITCH CONTROL. REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. A NIL LIGHTING FIXTURE WIRED TO EMERGENCY ANDIOR NIGHT LIGHTING CKT. ILLUMINATED"EXIT"SIGN, WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PANS. ®® z ILLUMINATED"EXIT"SIGN, CEILING MOUNTEDISUSPENDED. PROVIDE DIRECTIONAL ARROWSAS INDICATEDON FLOOR PLANS. ILLUMINATED "EXIT" SIGN, DUAL HUM, WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATEDON FLOOR PANS. ��ILLUMINATED"EXIT"SIGN, DUAL HEADS, CEILING MOUNTEDISUSPENDED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. 1 REMOTE EMERGENCY WEATHERPROOF LIGHTING HEAD SUPPLIED FROM REMOTE �p BATTERYUNIT. I_I EMERGENCY LIGHTING BATTERY UNIT NTH HEADS AS INDICATED, CEILING OR Dpa WALL MOUNTED. TC TIME CLOCK- REFERTO PLANS FOR SPECIFICATIONS. 6 LCP LIGHTING CONTROL PANEL- REFER TO PLANS FOR SPECIFICATIONS. �,e DOORBELL - REFERTO PLANS FOR SPECIFICATIONS. ❑w DOOR BELL RISHBUTTON- REFERTO PLANS FOR SPECIFICATIONS. QT THERMOSTAT- PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 314" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. ( HVAC UNIT MOUNTED LIGEE-RECEPTACLE JQRi'? JUNCTION BOX AND DISCONNECT SWITCH FOR SIGNAGE TECHNOLOGY SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) _ HOMERUN TO EQUIPMENT INDICATED. REFER TO PLANS AND SPECIFICATIONS FOR ALLREQUIREMENTS. - — — - INFLOORIUNDERFLOOR CONDUITNVIRE CIRCUITRY TURNING UP ® TELEPHONE FIRE RATED PLYWOOD BACKBOARD- SIZE INDICATED ON PLAN. COMBINATION VOICEIDATA OURET- MOUNTED AT WARE UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 39"CONDUIT TO ABOVETHE ACCESSIBLE CEILING.454" INDICATES WALL MOUNTED AT 54"AFF,"C" INDICATES MOUNTED T ABOVE COUNTER. 0 DATA OUTLET -MOUNTED AT i Si UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3I4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "+54" INDICATES WALL MOUNTED AT 54" ARE, "C" INDICATES MOUNTED 8"ABOVE COUNTER. 8 VOICE OUTLET- MOUNTED AT 16 ARE UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 314" GONDUIT TO ABOVE THE ACCESSIBLE CEILING. "+54" INDICATES WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED WABOVE COUNTER. 4 TV OUTLET- MOUNTEDAT iS AFF UNLESS OTHERWISE NOTED. PROVIDESINGLE GANG BOX WITH RASTER RING AND 314' CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "+54" INDICATES WALL MOUNTED AT 54" ARE, "O INDICATES MOUNTED 8" ABOVECOUNTER FIRE ALARM SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) CFACP FIRE ALARM CONTROL PANEL CFAEP FIRE ALARM EXTENDER PANEL 6FAA FIRE ALARM ANNUNCIATOR PANEL 6 FACU FIRE ALARM CONTROL UNIT Q FIRE ALARM MANUAL PULL STATION MOUNTED AT 48"AFF. 1Y FIRE ALARM HORNISTROBE ALARM SIGNAL WALL MOUNTED AT&I"AFF. FIRE ALARM HORNISTROBE ALARM SIGNAL CEILING MOUNTED FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 8T AFF. x FIRE ALARM VISUAL ONLY ALARM SIGNAL CEILING MOUNTED FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR FIRE ALARM DUCT MOUNTED SMOKE DETECTOR WITH SAMPLING TUBE, FURNISHED AND'MRED BY EC, MOUNTED BY MC. REMOTE INDICATOR LIGHTIAUDIBLE ALARM FOR DUCT SMOKE DETECTOR CEILING FIRE ALARM HORNISTROBE FIRE ALARM MANUAL PULL STATION PROVIDE WIRING PER MANUFACTURER'S INSTALLATION DRAWING (TYR) SIGNALING LOOP 9VMAXIMUM MISCELLANEOUS 83" MINIMUM TELEPHONEOUTLET 1 THERMOSTATS © El Ob H8 na¢ 1ELM RECEPTACLE WALL SWITCH DATA OUTLET 48" MAXIMUM UNLESS LOCATED ABOVE "OBSTRUCTION" SUCH AS A COUNTER THEN 4T MAXIMUM HEIGHARE TYPICAL UN ESS OTHERWISE NOTED. © g 18"MINIMUM FINISHED FLOOR SYNCHRONIZING SEE PLANS FORPNLCII 2 TYPICAL MOUNTING HEIGHTS EDA SCALE: NONE FAEP ETR PROVIDE CONTROL MODULE FOR REQUIRED FUNCTION (TYPICAL). INITIATING CONTROL LOOP PROVIDE WIRING AND RELAY REQUIRED TO SHUTDOWN TENANT SOUND SYSTEM UPON FIRE ALARM ACTIVATION WIRING TO BASE BUILDING MAIN FIRE ALARM PANEL (ETR) 1 FIRE ALARM EXTENDER PANEL WIRING DIAGRAM EO.1 SCALE: NONE STRUCTURAL CEILING LAY-INCEILING T VIOLATION! OF HEIGHT CLEARANCE — N AREA OF WORKING SPACE DETAIL NOTES 1. THIS DIAGRAM REPRESENTS A TYPICAL SYSTEM AND IS NOT INTENDED FOR INSTALLATION. SYSTEM SUPPLIER SHALL PROVIDE INSTALLATION DRAWINGS AND SCHEMATIC WIRING DIAGRAMS. EXACT SYSTEM REQUIREMENTS SHALL BE COORDINATED WITH THE SYSTEM SUPPLIER. SYSTEM INSTALLER SHALL BE NICET CERTIFIED, IF REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. 2. SYSTEM SUPPLIER SHALL SUPERVISE INSTALLATION, PROGRAM AND TEST SYSTEM AND INSTRUCT OWNER ON SYSTEM OPERATION. 3. ALL FIRE ALARM WIRING SHALL BE PLENUM RATED. EXPOSED FIRE ALARM WIRING, 10'W ARE AND BELOW, SHALL BE INSTALLED IN CONDUIT TO ABOVE ACCESSIBLE CEILING SPACE OR STRUCTURE. 4. ALL CONTROL CABINETS SHALL BE GROUNDED PER NEC REQUIREMENTS AND PER SPECIFICATIONS. 5. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. REFER TO DRAWINGS FOR DEVICE QUANTITY AND LOCATIONS. 6. FIRE ALARM DEVICES SHALL MATCH LANDLORD'S EXISTING FIRE ALARM SYSTEM. A SUSPENDED CEILING IS NOT STRUCTUREI VIOLATION! 110.26 (E) FOR SWITCHBOARDS, MOTOR CONTROL CENTERS, AND PANELBCARIDS; SPACE FOR WIDTH AND DEPTH OF EQUIPMENT MUST BE CLEAR OF ANY TOREIGN' PIPING, DUCTS, OR EQUIPMENT TO 6' ABOVE EQUIPMENT OR TO STRUCTURAL CEILING STRUCTURALCEILING LAY- IN CEILING AREA OF WORKING SPACE HEIGHTOF PANELBOARDS,ETG I SPACE6'-6" 6'-6" (MINIMUM) (MINIMUM) VIOLATION! EQUIPMENT IS NOT PERMITTED IN WORKING GRADE, FLOOR SPACE 110.26(A)(3) OR PLATFORM GRADE, FLOOR RANSFORME OR PLATFORM VIOLATIONS ACCEPTABLE 3 SUMMARY OF NEC 110.26 CLEARANCE REQUIREMENTS EO.1 I SCALE: NONE THIS IS NOT AVIOLATION IF MORE THAN 6-0" ABOVE EQUIPMENT AND PROTECTION FROM LEAKS IS PROVIDED — PIPING, ETC. PERMITTED IF I. NOT WITHIN HEIGHT OF WORKING SPACE AND NOT OVEREQUIPMENT I6 FOR CLEARANCE OF AIR SPACE ABOVE EQUIPMENT SEE 11026(F) PANELBOARD$ ETC. MORE THAN 6" PERMITTED IF ASSOCIATED AND NOT MORE THAN T BEYOND FRONT OF EQUIPMENT (11016 (A) (3)) CURRAN ARCHITECTURE 5719 LAWTON LOOP EAST DR STE 212 INDIANAPOLIS, IN 46216 O 317.288.0681 IF :: 317.288.0753 I CONSULTANT I DRAWN BY: JDJ CHECKED BY: JSD *T/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 8717954 tesengineering.com CERTIFICATION STATE OF 7/11/2019 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAIN® HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY C£ CURRAN ARCHITECRAtE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, VJIT40l1T THE WRITTEN CONSIENT U CURRAN ARCHITECTURE. ® COPFFSM 2019, OWN ARMRERUFE INTERIOR BUILD -OUT FOR: F45 CLAY TERRACE CLAY TERRACE BLVD. E14 CARMEL, IN ELECTRICAL LEGEND & DETAILS ISSUE DATES ISSUED FOR REVIEW 4-13-19 ISSUED FOR PERMIT 7-10-19 PROJECT NUMBER: 180364 E 0. I