HomeMy WebLinkAboutElectrical E2.0MECHANICAUPLUMBING EQUIPMENT CONNECTION SCHEDULE NAME VOLTAGE PHASE MCA MOCP CONDUIT/WIRE PANEL GRCUIT# NOTES EXAHUA 480 3 ETR ETR ETR ETR ETR 3 EXAHU-2 480 3 ETR ETR ETR ETR ETR 3 EXCU-1 480 3 ETR ETR ETR ETR ETR 3 EX4CLL2 208 3 ETR ETR ETR ETR ETR 3 ECH-1 208 1 19.2 25 2910,1#10GND-3/41,C LPB 40,42 1 EX-EF-1 120 1 ETR ETR ETR ETR ETR 3 EF-2 120 1 0.1 20 2912,1#12GND-3/4"C EPA 5 1 EF-3 120 1 0.1 20 2#12,1#12GND-3/4"C EPA 5 1 EF-4 120 1 0.1 20 2#12,1#12GND-3/4"C LPA 5 1 WHA 480 3 9.6 15 3#12,1#12GND-3/4"C H 2O,22,24 2 NOTES' 1. EQUIPMENT PROVIDED WITH INTEGRAL DISCONNECT SWITCH. 2. PROVIDE CODE -SIZED DISCONNECT SWITCH AT EQUIPMENT. 3. EXISTING EQUIPMENTTO REMAIN, MAINTAIN ALL ASSOGATED CONDUIT AND WIRING. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�12'�B*VAWML DATE: \ 08/15/19 GENERAL SHEET NOTES 1. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INCREASED WIRE SIZES DUE TO FIELD CONDITIONS RESULTING IN EXTENDING CONDUIT PATHS. GROUND WIRE SITES ARE REQUIRED TO BE ADJUSTED PER ARTICLE 2500F THE NEC WHEN WIRES ARE INCREASED FOR VOLTA( DROP. 2. ALL BRANCH CIRCUIT WIRING SHALL BE#12AWG UNLESS OTHERWISE NOTED AND IN CONDIAMINT. EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR O SHEET KEYNOTES 1 PROVIDE JUNCTION BOX,SWITCH, AND WHIP FOR STORE SIGN. ADDITIONAL JUNCTION BOXES, CONDUIT, AND WIRING MAY BE REQUIRED FORA COMPLETE INSTALLATION OF SIGN. COORDINATE ALL REQUIREMENTS WITH SIGN VENDOR. 2 PROVIDE SHOW WINDOW RECEPTACLE PER NEC REQUIREMENTS. RECEPTACLE SHALL BE INSTALLED WITHIN 18' OF THE TOP OF THE SHOW WINDOW FOR EACH 12' OF SHOW WINDOW. VERIFY EXACT LOCATION WITH ARCHITECT. 3 LOCATION OF TIME CLOCKSICONTACTORS. REFER TO DETAIL 21E2.0 AND WE2.0 FOR ADDITIONAL INFORMATION. 4 LOCATION OF EXISTING TELCO DEMARK, MAINTAIN EXISTING PUNCH DOWN BLOCK AND PLYWOOD BACKWARD FOR TELEPHONENATA SERVICES. COORDINATE ALL REQUIREMENTS WITH OWNER. 5 EXISTING ELECTRICAL EQUIPMENT TO REMAIN. 6 PROVIDE RECESSED RECEPTACLE AND DATA JACK FOR MONITOR. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECT. 7 CONNECT FIRE ALARM DEVICE TO EXISTING SYSTEM. REFER TO DETAIL 11E0.1 FOR ADDITIONAL INFORMATIGN. DEVICE SHALL MATCH EXISTING SYSTEM MANUFACTURER 8 REFER TO MECHANICAUPLUMBING EQUIPMENT SCHEDULE ON THIS SHEET FOR CIRCUITING INFORMATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. 0 0 N KEY PLAN CURRAN ARCHITECTURE 5719 LAWTON LOOP EAST DR STE 212 INDIANAPOLIS, IN 46216 O 317.288. 0681 IF :: 317.288.0753 CONSULTANT DRAWN BY: JDJ CHECKED BY: JSD OT/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.com CERTIFICATION STATE OF 7/11/2019 THIS DRAWING AND THE IDEAS. DESIGNS AND CONCEPTSCONTAINEDHERFIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITEC RE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE 8 COPYFSM 2019, OWN ARMRECUFE INTERIOR BUILD -OUT FOR: F45 CLAY TERRACE CLAY TERRACE BLVD. E14 CARMEL, IN POWER PLAN ISSUE DATES ISSUED FOR REVIEW 4-13-19 ISSUED FOR PERMIT 7-10-19 PROJECT NUMBER: 180364 E2.0