HomeMy WebLinkAboutHVAC M0.2MOTORIZED DAMPER TO CLOSE UPON DEACTIVATION OF AHU RA OPENING UP 8" IN VERTICAL FROM RETURN M DUCT. SEE PLAN FOR SIZE Oy9 D REFRIGERANT PIPING I AH L ALL) DRAIN LINE FROM UNIT WI FLEX CONNECTIONS TO RETURN AIR DUCT WITH FLEX CONNECTION TO UNIT, DUCT TO BE PROVIDED WITH 1" ACOUSTIC LINING, REFER TO PLANS FOR SIZES — ANGLE SUPPORT FOR AHU AND DRAIN PAN RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City Bf Camel �M;R��BtB,A�DA�1 DATE: 08/15/19 3" DEEP WATERTIGHT DRAIN PAN, PAN SHALL BE 3' LARGER THAN UNIT ON ALL SIDES SEE STRUCTURAL DRAWINGS FOR CONNECTION DETAILS AND FURTHER INFORMATION VIBRATION ISOLATOR (TYPICAL) A SUPPLY AIR DUCT WITH FLEX CONNECTION TO UNIT, REFER TO PLANS SIZES SHUTDOWN UNIT WHEN CONDENSATE WATER ENTERS DRAIN PAN. LOCATE SENSOR AT LOW POINT IN PAN. DETAIL NOTES 1. MC SHALL LOCATE AHU TO MAINTAIN A MINMUM 24" SERVICE CLEARANCE IN FRONT OF UNIT FOR MOTOR ACCESS PANEL FROM ANY EXISTING BUILDING STRUCTURE OR PIPING EXTENDING DOWN TO CEILING PER MANUFACTURERS RECOMMENDATIONS. MC SHALL COORDINATE WITH OTHER TRADES TO KEEP THIS SERVICE AREA CLEAR OF ANY NE:V P PING OR CONDUIT. 1 SPLIT SYSTEM MIN OA AHU DETAIL M0.2 SCALE: NONE RECTANGULAR DUCTWORK VARIES MINIMUM TAKE OFF AREA 1.25 TIMES BRANCH DUCT AREA RECTANGULAR TO ROUND "BUCKLEY FITTING" RECTANGULAR DUCTWORK 4' BRANCH DUCT HEIGHT DIMENSION 2' LESS THAN MAIN DUCT HEIGHT DIMENSION RECTANGULAR TO RECTANGULAR ROUND DUCTWORK LOW -LOSS TEE FITTING OR SADDLE 2 DUCT BRANCH TAKE -OFF DETAIL MU SCALE: NONE HANDTIGHT PLUG COPPER CONDENSATE DRAIN LINES TO PREVENT AHU FROM RUST DAMAGE, DO NOT USE PVC FOR CONDENSATE BRAIN LINES, KEEP VERTICAL CONDENSATE LINE A MINIMUM OF T FROM AHU 4 AHU CONDENSATE DETAIL 110.2 SCALE: NONE nna.naLmnalay FULL RADIUS ELBOW RECTANGULAR ELBOW 15, MAX T} AIRFLOW / TRANSITION LENGTH TO BE 18" MIN DIVERGING FLOW LOW VELOCITY ELBOWS 15, MAX AIR FLOW TRANSITION LENGTH TO BE 18' MIN CONTRACTING FLOW RECTANGULAR TO RECTANGULAR TRANSITIONS III FULL HALIUs WHercE POSSIBLE (R- W) W ELBOWS 456 MAXIMUM 3 LOW VELOCITY TRANSITIONS AND OFFSETS Pill SCALE: NONE MAX. 12" TO BRANCH CONNECTION VOLUME DAMPER IF INDICATED ON PLAN 1-112-THICK FIBERGLASS INSULATION WI FOIL FACING SUPPLY AIR DIFFUSER GALVANIZEDSHEET METAL DUCT CED ELBOW METAL OR VINYL ADJUSTABLE STRAP CLAMP (TYR 2 PLACES) INSULATED FLEXIBLE CONNECTION IN VERTICAL ONLY (MAX. V) r LAYINCEILING DETAIL NOTES 1. CO NOT LOCATE DAMPERS ABOVE DRYWALUINACCESSIBLE CEILING LOCATIONS. 5 CEILING DIFFUSER MOUNTING DETAIL M0.2 SCALE'. NONE CURRAN ARCHITECTURE 5719 LAWTON LOOP EAST DR STE 212 INDIANAPOLIS, IN 46216 O :: 317. 288.0681 F :: 317. 288. 0753 CONSULTANT DRAWN BY: STK CHECKED BY: KDH *T/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 8717954 tesengineering.com CERTIFICATION STATE OF 7/11/2019 THIS DRAWING AND THE IDEAS. DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE I NTELLECTUAL PROPERTY OF CURRAN ARCH ITECTJ RE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITH OUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. 0 COPIRI 2019, CURMN ARCHITERUFE INTERIOR BUILD -OUT FOR: F45 CLAY TERRACE CLAY TERRACE BLVD. E14 CARMEL, IN MECHANICAL DETAILS ISSUE DATES ISSUED FOR REVIEW 413-19 ISSUED FOR PERMIT 7-10-19 PROJECT NUMBER: 180364 M 0.2