HomeMy WebLinkAboutPlumbing P0.1ABBREVIATIONS
PLUMBING SYMBOLS
(ALL ABBREVIATIONS SHOWN
ARE NOT NECESSARILY
USED ON DRAWINGS)
)ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS)
q
AMP AMPERE
ID
INSIDE DIAMETER
ABV ABOVE
IE INVERTEVATION
NC
AIR CONDITIONER, AIR CONDITIONING,
IN
INCH,CH,INCHES
ABOVECEILING
IN WC
INCHES OF WATER COLUMN
10
ELBOW UP
ACC
AIR COOLED CHILLER
ACCU
AIR COOLED CONDENSING UNIT
"A
KILOVOLT -AMPS
-0
ELBOW DOWN
ADJ
ADJUSTABLE
KW
KILOWATTS
AFC
ABOVE FINISHED CEILING
KWH
KILOWATT-HOUR
VALVE IN DROP
AFF
ABOVE FINISHED FLOOR
AEG
ABOVE FINISHED GRADE
L
INTERNALLY LINED
DIRECTION OF FLOW
AL
ACOUSTIC LINING
EAT
LEAVING AIR TEMPERATURE
ANSI
AMERICAN NAIL STANDARDS INSTITUTE
LBS,#
POUNDS
1a
TEE OUTLET UP
APD
AIR PRESSURE DROP
LDS
LEAVING DRY BULB
ARCH
AIR
LP
LOW PRESSURE
H
TEE OUTLET DOWN
ARI
CONDITIONING
AIR CONDITIONING& REFRIGINSTITUTE
LRA
LOCKED ROTOR AMPS
UNION
ASHRAE
AMERICAN
LTG
LIGHTING
RIGERATIONS CHEATING,
REFRIGERATION SAC ENGINEERS
LWB
LEAVING WET BULB
EXPANSION JOINT
ASME
AN SOCIETY OF MECHANICAL ENGRS
LWT
LEAVING WATER TEMPERATURE
ASSV
ASSEMBLY
BALL VALVE
ASEM
AMERICANSOCIETY OF TESTING BMATLS
MAX
MAXIMUM
AU%
ARY
AMERICAN
MBH
HOUR
PERICAL
OS&V VALVE
AWG
AMERICAN WIRE
MC
MECHAN
MINIMUM CIRCONTRACTOR
GATE VALVE
AWS
SO
AMERICAN WATER
MCA
UIT AMPCIT
MOTOR
AMA
WORKS
AMERICAN WATER WORKS A
ASSOC.
MCC
CONTROL CENTER
MOTORCONTROECENTER
CALIBRATED BALANCING VALVE
MD
MECH
MOTORIZED DAMPER
MECHANICAL
_
TV
CHECK VALVE
B/F BELOWFLOOR
BAS
BUILDING AUTOMATION SYSTEM
MFR
MANUFACTURER
BDD
BACKDRAFTDAMPER
MIT
MANHOLE, METAL HALIDE
�4_
PRESSURE REDUCING VALVE
SEW
BOILER FEED WATER
MIN
MINIMUM
BLDG
BUILDING
MOCP
MAXIMUM OVER CURRENT PROTECTION
CIE
BUTTERFLY VALVE
BMS
BUILDING MANAGEMENT SYSTEM
MT)
MOUNTED
BOD
BOTTOM OF DUCT
MUA
MAKE-UP AIR
3-WAY SELF OPERATING VALVE
BOP
BOTTOM OF PIPE
44
BOS
BOTTOM OF STRUCTURE
NIA
NOT APPLICABLE
DIO
2-WAY SELF OPERATING VALVE
BTU
BRITISH THERMAL UNIT
NC.
NORMALLYCLOSED
INC
NEC
NOISECRITERIA
NATIONAL ELECTRICAL CODE
_
MOTOR OPERATED VALVE
CA COMBUSTION AIR
CC
CONCRETE
NEMA
NATIONAL ELECTRICAL MFR'S ASSOC.
—
PIPE GUIDE
CFH
CUBIC FEET PER HOUR
NFPA
NATIONAL FIRE PROTECTION ASSOC.
HOSE BIB
CFM
CUBIC FEET PER MINUTE
NIC
NOT IN CONTRACT
CHWRICHWS CHILLED WATER RETURNISUPPLY
NO.
NORMALLYOPEN
—SAN—
SANITARY PIPING
CIRC
CIRCULATING
NTS
NOT TO SCALE
CKT
CIRCUIT
V
SANITARY VENT PIPING
CL
CENTERLINE
OIH
OVERHEAD
CLG
CEILING
CA
OUTSIDE AIR (VENTILATION AIR)
WE
STORM PIPING (ABOVE GROUND)
CO
CLEANOUT
DEG
OPPOSED BLADE DAMPER
OC
ON CENTER
ST
STORM PIPING (UNDERGROUND)
CONN
COP
CONNECT, CONNECTION
CLEANOUT PLUG
OD
OVERFLOW DRAINAGE, OUTSIDE DIAMETER
COL
COLUMN
OPNG
OPENING
OD
OVERFLOW GRAIN PIPING
CTE
CONNECT TO EXISTING
ORD
OVERFLOW ROOF DRAIN
—__
COLD WATER (CW) PIPING
CW
DOMESTIC COLDWATER
01
OUTSIDE STEM AND YOKE
CWRICWS
CONDENSING WATER RETURNISUPPLY
OSHA
OCCUPATIONAL SAFETY&HEALTH ADMIN.
HOT WATER URN) PIPING
°C
DEGREESCELSIUS
---
HOT WATER RECIRCULATION (Hi
PB PUSHBUTTON
D
DEPTH
PD
PRESSURE DROP
IDS
DRYBULB
FEED
PHASE
G
NATURAL GAS PIPING
dB
DECIBEL
PIV
POST INDICATOR VALVE
DDC
DIRECT DIGITAL CONTROL
PLED
PLUMBING
C
CAPON END LINE
DEG
DEGREES
PSI
POUNDS PER SQUARE INCH
4 FS
FLOW SWITCH
UNIONS)
DIAMETER
REV
PRESSURE RELIEF VALVE
DIM
DIMENSION
pPS
PRESSURE SWITCH
RA
RETURN AIR
ON DISCONNECT
D
DOWN
RCP
REFLECTED CEILING PLAN
TBP RELIEF VALVE
DOM
DOMESTIC
RD
ROOFDRAIN
DS
DOWNSPOUT
RECIRC
RECIRCULATE
PRESSURE GAUGE WITH GAUGE COCK
DWG
DRAWING
RE
REINFORCING, REINFORCED
DX
DIRECT EXPANSION
REDL
RELOCATED
THERMOMETER
REV
REV
REQUIRED
REMOVE ,XISTIN
FLE%IBLE CONNECTION
EA EACH
EAT
ENTERING AIRTEMPERATURERE%
REMOVE EXISTING
EC
ELECTRICAL CONTRACTOR
RH
RELATIVE HUMIDITY
PIPE FLANGE
EDB
ENTERING DRY BULB
RHG
REFRIGERANTHOTGAS
— — — —F
THERMOMETER WELL
ELEV
ELEVATION
RE
REFRIGERANT LIQUID
ELEC
ELECTRICAL
RLA
RUNNING LOAD AMPS
z
IVT
GAS VALVE
ENCL
ENCLOSURE
RPM
REVOLUTIONS PER MINUTE
�
EQUIP
EQUIPMENT
RR
REMOVE AND RELOCATE
WATERMETER
ESP
EXTERNAL STATIC PRESSURE
RS
REFRIGERANT SUCTION
ETR
EXISTING TO REMAIN
RWC
RAIN WATER CONDUCTOR
®
GAS REGULATOR
EWB
ENTERING WET BULB
SA
SUPPLY AIR
4
WALL CLEANOUT OR CLEAOUT PLUG
EWT
ENTERING WATER TEMPERATURE
SAN
SANITARY
EXH
EXHAUST
SO
SMOKE DETECTOR, STORM DRAIN
FLOOR CLEANOUT
EX
EXISTING
SECT
SECTION
FLOORSINKES)
FA
FIRE ALARM
SF
SQUARE FEET SQUARE FOOT
FACP
FIRE ALARM CONTROL PANEL
BHT
SHEET
OC
FLOOR DRAIN WITH P-TRAP
FOO
FLOOR CLEANOUT
SM
SHEET METAL
FD
FIRE DAMPER
SMACNA
SHEET METAL BAIC CONT NAIL ASSOC.
TO OTION-
MINFF
FINISHED FLOOR
SP
STATIC PRESSURE
NEW EXISTING
FLA
FULL LOAD AMPS
SPEC
SPECIFICATION
FLEX
FLEXIBLE
SQ
SQUARE
I^1 �
V
DRAWING NOTE REFERENCE
FP
FIRE PROTECTION
ST
STORM WATER
FPM
FEET PER MINUTE
STD
STANDARDSURF
0 p
PLUMBING FIXTURES
FT
FOOT FEET
SURFACE
FW
FILTERED WATER
SUSP
SUSPEND-----
E22--
GAS MANIFOLD LOCATION
TON
TE
TOTAL DYNAMIC HEADD�
TENANT EXHAUST (TOILET)
F DEGREES FAHRENHEIT
DCV
DOUBLE CHECK BACKFLOW PREVENTER
G GAS
GA
GAUGE
THIRD
THROUGH
GAL
GALLON
TP
TOTAL PRESSURE
DOMESTIC WATER RISER
GALV
GALVANIZED
TSP
TOTAL STATIC PRESSURE
GC
GENERAL CONTRACTOR
TSTAT
THERMOSTAT
----- 0—
STUB UP FOR FUTURE
GPI, GFIC
GROUND FAULT INTERRUPTER
TWRIRNS
TOWER WATER RETURNISUPPLY
TENANT CONNECTION
GPD
GALLONS PER DAY
TYP
TYPICAL
•
SPRINKLER HEAD(SEMI-RECESSED)
UIF
UNDERFLOOR
GPH GALLONS PER HOUR
GPM
GALLONS PER MINUTE
LED
UNDERGROUND
0
SPRINKLER HEAD( FULLY -RECESSED)
GRD
DWI
GROUND
GREASEWASTE
US
UNDERSEAS
O
SPRINKLER HEAD (UPRIGHT)
UL
LOU
UNDERWRITERS LABORATORIES, INC.
UNLESS OTHERWISE NOTED
H HEIGHT
HD
HEAD, HUB DRAIN
V VOLT, VENT
HHWWHHWS HEATING HOT WATER RETURNISUPPLY
VA
VOLT-AMPERE, VALVE
HOA
HANDOFF-AUTOMATIC
VAC
VACUUM
HE
HORSEPOWER, HEAT PUMP
VAV
VARIABLE AIR VOLUME
HSTAT
HUMIDISTAT
VD
VOLUME DAMPER
Al
HEATING
VTR
VENT THROUGH ROOF
HER
HEATER
W
WATT. WIDTH
Al HEATING, VENTILATING & AIC
HW
DOMESTIC HOT WATER
WI
WITH
NOR
DOMESTIC RECIRCULATED HOT WATER
W/o
WITHOUT
HVD
HYDRANT
WB
WET BULB
HE
HERTZ
WC
WATERCOLUMN
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City M Camel
�VT�12'�B*VAWML
DATE: \ 08/15/19
PLUMBING FIXTURE AND EQUIPMENT SCHEDULE
CONNECTION SIZE
TAG
FIXTURETYPE
MFR
MODELNo.
DESCRIPTION
MN
VENT
HW
CW
ET
THERMAL EXPANSION
-
-
-
314"
AMTROL
ST-25V
THERMAL EXPANSION ABSORBER. 10.3 MAXIMUM ACCEPTED GALLONS. MOUNT ON
TANK
WALL WITH UNISTRUT.
FURNISH WITH DUCO CAST IRON BODY WITH TRAP GUARD OR EQUIVALENT (UNLESS
FDH
FLOOR DRAIN
SEE
-
112'
J.R. SMITH
2O05
LOCAL AHJ DOES NOT ALLOW), SEDIMENT BUCKET,5" SECURE GRATE, AND OUTLET
PLANS
AS REQUIRED BY PIPING MATERIAL. COORDINATE WITH THE ARCHITECT FOR SQUARE
OR ROUND TYPE TOP.
"LUCERNE" WALL HUNG LAVATORY WITH FAUCET LEDGE, FAUCET HOLES ON 4"
CENTERS,&WALL HANGER. FAUCET SHALL BE MOEN MODEL 8430, CHROME, 4"
CENTERSET, la CONNECTIONS AND LEVER HANDLE FURNISH CHROME STOPS,
LAVE
LAVATORY(ADA)
1-112'
1-112"
112'
112•
AJERICAN
035fi.012
SUPPLIES AND A I-114" WHEELCHAIR LAVATORY DRAIN WITH STAINLESS STEEL GRID
S-MD.\RD
ANDP-TRAP. PROTECT TRAP AND SUPPLIES WITH A TRAP WRAP KIT 50OR AS
MANUFACTURED BY BROCAR PRODUCTS INC. LAVATORY MOUNTING HEIGHT SHALL
BE AS DETAILED ON ARCHITECTURAL DRAWINGS. PROVIDE ZURN 4Z-1021 WATER
SAVER TRAP PRIMER. PROVIDE TMV-1.
24" X 24" X 10" HIGH, MOLDED STONE MOP SINK WITH No. 1453 BB DRAIN AND
STRAINER, No. 833AA SILICONE SEALANT, (2) No. E-77-AA VINYL BUMPER GUARD AND
MS
MOP SI NK
3"
1-112'
112'
112'
F-T
MSB2424
Na.830-AA SERVICE FAUCET WITH VACUUM BREAKER, INTEGRAL STOPS, ADJUSTABLE
WALL BRACE, PAIL HOOK AND 3W HOSE THREAD ON SPOUT, N0. 832-PA HOSE AND
HOSE BRACKET, No. 884-CC MOP HANGER. MOUNT FAUCET ON WALL 30" A F F.
ADA THREE FUNCTION SHOWER SYSTEM, PRESSURE BALANCING, DY METAL HOSE,
SH-1
SHOWER AND STALL
2
1-112'
1:2"
1!2'
610EN
8342EP15
30"SLIDE BAR, DROP ELL, AND MOUNTING HARDWARE. WATER SENSE CERTIFIED. 15
GPM FLOW. SHOWER STALL: EQUAL TO AQUABATH CO. MODEL C41366F-FUS-314".
THERMOSTATIC MIXING VALVE WITH BRONZE BODY. COPPER ENCAPSULATED
THERMOSTATIC MIXING
THERMOSTAT, BRASS INTERVALS. STAINLESS STEEL SPRING, LOCKED TEMPERATURE
TMV-1
VALVE
-
-
-
-
ZURN
ZN3870XLT
ADJUSTMENT KNOB (TAMPER RESISTANT). INTEGRAL CHECK VALVES ON INLETS. MPS
CONNECTIONS, ROUGH BRONZE FINISH, AND ASSE STANDARD 1070 LISTED. OUTLET
WATER TEMPERATURE TO BE SET AT 105- F.
TP
TRAP PRIMER
-
-
-
112"
PER
PR 600
TRAP PRIMER VALVE ASSEMBLY. AUTOMATIC PRESSURE ACTIVATED TRAP PRIMER
VALVE.
FLOOR MOUNTED WATER
AMERICAN
"CADET" RIGHT HEIGHT ELONGATED FLUSH TANK TOILET WITH ALL ASSOCIATED TRIM,
WC-1
CLOSET (ADA)
3
1-112
-
112
STANDARD
2467.016
FITTINGS AND HARDWARE. SEAT SHALL BE WHITE SOLID PLASTIC SEAT WITH OPEN
FRONT LESS COVER.
WOO
WALL CLEAN OUT
SEE
-
-
J.R. SMITH
4400 SERIES
THREADED CLEANOUT PLUG WITH FERRULE AND ROUND ACCESS COVER WITH
PLANS
EITHER NICKS- BRONZE OR CHROME FINISH.
ELECTRIC WATER
40 GALLON CAPACITY, 8 KW, 32 GET! RISE @ 100-F RISE. SET TO MANUFACTURER'S
WH 1
HEATER
-
1"
1"
AO SNIT
DEL40
RECOMMENDATIONS, PROVIDE TRIP RELIEF, 480V, 4000 WATTS
STANDARD P.D.I. WH 201 WATER HAMMER
ARRESTER SCHEDULE
P.D.I. UNITS O OA O OC O OE OF
FIXTURE 13 411 1232 33-60 61-113 114-154 155330
UNITS
WATER PIPE SIZING
PIPE SIZES BASED ON TYPE "_'COPPER @ 3 PSIG1100 FT. VELOCITY NOT TO
EXCEED ART. PER SECOND FOR COLD WATER AND 5 FT PER SECOND FOR
HOTWATER
PIPE SIZE
WATER SUPPLY FIXTURE UNITS (WSFU)
HOT WATER NW)
FLUSHTANK(CW)
11?
1-3
1-3
314"
4
4
1"
12
1-114'
24
24
1-1)2'
46
45
2'
119
2-112
245
380
CURRAN
ARCHITECTURE
5719 LAWTON LOOP EAST DR STE 212
INDIANAPOLIS, IN 46216
O :: 317.288.0681
F :: 317.288.0753
CONSULTANT
DRAWN BY: JJC CHECKED BY: KDH
*T/E/S
ENGINEERING
25760 First Street
Cleveland, OH 44145
P 440 871 2410
F 440 8717954
tesengineering.com
CERTIFICATION
STATE OF
7/11/2019
THIS DRAWING AND THE IDEAS. DESIGNS
AND CONCEPTS CONTAINED ESSEN ARE
THE EXCLUSIVE I NTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITH OUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
0 COPrNGHT 2019, CURMN ARCHITECTURE
INTERIOR BUILD -OUT FOR:
FE
F45 CLAY TERRACE
CLAY TERRACE BLVD.
E14
CARMEL, IN
PLUMBING LEGEND AND
SCHEDULES
ISSUE DATES
ISSUED
FOR REVIEW
413-19
ISSUED
FOR PERMIT
7-10-19
PROJECT NUMBER: 180364
Poo I