HomeMy WebLinkAboutPlumbing P0.2REFER TO PLANS AND —+I RISER DIAGRAMS FOR EXTENSION AS WASTE OR VENT CONTINUATION OCCURS CLEANOUT ROUND SECURED ACCESS COVER, COUNTERSINK SCREW, FINISH AS SELECTED BY ARCH 1 WALL CLEANOUT DETAIL PO SCALE: NONE HANGER ROD LOCKING NUTS SUPPORTNUI HEAVY DUTY CLEVIS HANGER. MATERIAL TO MATCH PIPE PIPE e POLYISOCYANURATE INSULATION BLOCK INSTALLED � 180ORIBBED18GA SHIELD SIMILAR J TOANVIL p168 2 PIPE SUPPORT DETAIL 9.1/2" -12"0 PO.2 SCALE: NONE HANGER ROD --�, LOCKING NUT SUPPORT NUT HEAVYDUTYCLEVIS HANGER. MATERIAL TO MATCH PIPE --- PIPE � a FIBERGLASS INSULATION PERSPECS� 180°RIBBEDIBGA SHIELD SIMILAR TOANVILp168 - ASJISSL BUTTSTRIP (TYPICAL) RIB (TYPICAL) 2' 3 UP TO 1-1/4" PIPE SUPPORT DETAIL PO.2 SCALE: NONE SEE NOTE k2 LAVISINK WATER CUT-OFF MASTIC STAINLESS STEEL CHECKVP CLAMPING RING (TYPICAL) PREMOLDEDCOLD PIPE SEAL SPLICING CEMENT WATER r FLEXIBLE PRIMER TUBE SUPPLY ROOFING LAP SEALANT MEMBRANE O O OW) AV 112" TEMPERED ESCUTCHEON WATER LINE INSULATION II , 1 GENERAL NOTES ��Y 1. PRE -MOLDED PIPE SEAL CANNOT BE CUT VERTICALLY TO BE INSTALLED. 2. PRE -MOLDED PIPE SEAL MUST HAVE INTACT RIB AT THE TOP EDGE, REGARDLESS OF PIPE DIAMETER. 3. WHEN PRE -MOLDED PIPE SEAL CANNOT BE INSTALLED, USE FIELD FABRICATED PIPE SEAL. 4. FOR BALLAST SYSTEMS, REPLACE BALLAST AFTER WORK IS COMPLETED. 5. FLANGE MUST BE SET BY ROOFER, COORDINATE WITH ROOFING CONTRACTOR. 6. VENTS SHALL BE A MINIMUM OF 154' FROM OUTSIDE AIR INTAKES. T DO NOT TRIM DECK FLANGE 5 PIPE THROUGH ROOF DETAIL P0.2 SCALE: NONE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �M;RAv�tB,A�DA�1 DATE: 08/15/19 UNDER THE COUNTER THERMOSTATIC TEMPERING VALVE - I2" NOTE: TEMPERING VALVE SERVING LAVATORY IN TOILET ROOMS, BREAK ROOM SINKS, AND HAND SINKS SHALL BE WATTS SERIES LFMMV WITH A MINIMUM FLOW OF,5 GPM AND 2 GPM @ 10 PSI PRESSURE DIFFERENTIAL. NOTE: TEMPERING VALVE SHALL BE LISTED TO ABBE 1070 STANDARD. SET OUTLET TEMPERATURE TO 105°F. 6 "TMV" THERMOSTATIC MIXING VALVE DETAIL PO.2 SCALE: NONE SIOUX CHIEF TRAP EASE' MODEL M200-092 PLATED POLISHED CAST BRASS BODY WITH CLEAN( FLOOR 1/2,, SOFT COPPER PRIMER LINES PRIMER PIPING CONCEALED IN WALL FLOOR DRAIN SEWER 7 1 TRAP PRIMER DETAIL P0.2 I SCALE: NONE Ii HANGER LOCKING HEAVY DUTY CLEVIS HANGER. MATERIAL TO MATCH PIPE. PIPE 4 UNINSULATED PIPE SUPPORT DETAIL PO.2 SCALE: NONE CHECKVALVE SEE PLANS FOR SIZES 5--HW —CW DIELECTRIC UNION (TYPICAL) ELECTRIC WATER HEATER - SEE SCHEDULE ALUMINUMLAGERT AN HEATER 2" DIAMETER HEATER 4"HIGH CONCRETE PAD WITH CHAMFERED EDGES 8 ELECTRIC WATER HEATER DETAIL P01 SCALE: NONE CURRAN ARCHITECTURE 5719 LAWTON LOOP EAST DR STE 212 INDIANAPOLIS, IN 46216 O :: 317. 288.06,81 F :: 317. 288. 0753 I CONSULTANT DRAWN BY: JJCCHECKED BY: KDH EXPANSION TANK(SEE SCHEDULE) *T/E/S VACUUM RELIEF VALVE ENGINEERING THERMOMETER BALL VALVE (TYPICAL) 25760 First Street Cleveland, OH 44145 P 440 871 2410 ASME APPROVED F 440 8717954 TEMPERATURE AND tesengineering.com PRESSURE RELIEF VALVE RELIEF PIPE FULL CERTIFICATION SIZE F DISCHARGE OPENING FLOOR DRAIN -SEE PLANS S�.. r W FOR LOCATION 32 INC. PE110S006 FINISHED FLOOR jjV%, STATE OF 7/11/2019 THIS DRAWING AND THE IDEAS. DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE I NTELLECTUAL PROPERTY OF CURRAN ARCH ITECTJ RE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITH OUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. 0 COPIR'LHT 2019, CURMN ARCHITECTURE INTERIOR BUILD -OUT FOR: FE F45 CLAY TERRACE CLAY TERRACE BLVD. E14 CARMEL, IN PLUMBING DETAILS ISSUE DATES ISSUED FOR REVIEW 4 13-19 ISSUED FOR PERMIT 7-10-19 PROJECT NUMBER: 180364 P092