HomeMy WebLinkAboutPlumbing P1.0RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf Camel �VT�12'�B*VAWMC_ DATE: \ 08/15/19 Q SHEET KEYNOTES GENERAL SHEET NOTES 1 112' DOMESTIC COLDWATER DOWN IN WALL TO WG1. A. FIELD VERIFY EXACT CONDITIONS AND ROUTING OF WORK. CONTACT ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE. 2 112' DOMESTIC COLDWATER AND HOT WATER DOWN IN WALL TO LAV4. PROVIDE THERMOSTATIC MIXING VALVE. B. EXISTING PLUMBING INFORMATION IS BASED ON EXISTING BUILDING DRAWINGS AND LIMITED FIELD WORK. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. NO 3 712'DOMESTIC COLD WATER AND HOT WATER DOWN IN WALL TO MS-1. ADDITIONAL COMPENSATION SHALL BE ALLOWED FOR REVISIONS TO THE DESIGN TO CORRECT FOR 4 1314' DOMESTIC COLD WATER AND HOT WATER DOWN IN WALL T0(2) SH-1, EXISTING CONDITIONS NOT AS INDICATED ON THE PLANS. 5 314' DOMESTIC COLD WATER AND HOT WATER DOWN IN WALL TO WH-1. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE CONFLICTS PRIOR TO BIDDING. 6 112' DOMESTIC COLD WATER DOWN IN WALL TO EWC 1. D. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. 7 112' DOMESTIC COLD WATER DOWN IN WALL TO TRAP PRIMER. E. REFER TO DRAWINGS, GENERAL NOTES OF OTHER DISCIPLINES, AND PROJECT SPECIFICATIONS FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF ANY CONFLICTS 8 1'CW PIPING CONNECT TO EXISTING CW MAIN. CONTRACTOR TO FIELD VERIFY EXACT SIZE AND BETWEEN THE INFORMATION PRESENTED AND FIELD CONDITIONS. LOCATION OF EXISTING CW MAIN PRIOR TO COMMENCING WORK. F. PROVIDE STOP VALVES AT EVERY FIXTURE ON COLD WATER SUPPLY LINES. VALVES, ESCUTCHEONS, FITTINGS, ETC. MUST BE CHROME PLATED. WHERE EXPOSED, CHROME PLATED PIPE IS TO BE USED. G. ALL OVERHEAD PIPING IS TO BE ROUTED TIGHT TO BUILDING STRUCTURE. H. PIPING IS NOT PERMITTED IN DEMISING WALLS. I. DO NOT ROUTE ANY WATER CONVEYING PIPING OVER ELECTRICAL EQUIPMENT. J. ALL EXPOSED OR ACCESSIBLE P-TRAPS MUST BE PROVIDED WITH BOTTOM CLEANOUT PLUGS. K. INSULATE EXPOSED P-TRAPS, HOT AND COLD VALVES AND PIPING SERVING HANDICAPPED LAVATORIES. L. PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS OR DEMOLITION THE CONTRACTOR SHALL PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES ENGINEERINGIMAINTENANCE PERSONNEL OF WORK TO BE PERFORMED 50 AS TO AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO ADJACENT SPACES. M. CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE. OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70. N. NO PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT MAY BE SUPPORTED FROM THE SUSPENDED CEILING SYSTEM, BUT MUST BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. 0. PROVIDE HEAT TRACING FOR ALL PLUMBING LINES EXPOSED TO OUTSIDE ELEMENTS. N KEY PLAN CURRAN ARCHITECTURE 5719 LAWTON LOOP EAST DR STE 212 INDIANAPOLIS, IN 46216 O :: 317.288.06,81 F :: 317.288.0753 CONSULTANT DRAWN BY: JJC CHECKED BY: KDH *T/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 8717954 tesengineering.00m CERTIFICATION STATE OF 7/11/2019 THIS DRAWING AND THE IDEAS. DESIGNS AND CONCEPTS CONTAINED HEREN ARE THE EXCLUSIVE I NTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITH WT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. 0 COPIWLHT 2019, CURMN ARCHITECTURE INTERIOR BUILD -OUT FOR: FE F45 CLAY TERRACE CLAY TERRACE BLVD. E14 CARMEL, IN PLUMBING DOMESTIC WATER PLAN ISSUE DATES ISSUED FOR REVIEW 4 13-19 ISSUED FOR PERMIT 7-10-19 PROJECT NUMBER: 180364 P1.0