HomeMy WebLinkAbout19080020 Energy AuditIECC 2009 Performance Compliance
Property
6801 PULASKI CT
CARMEL, IN 46033
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94
LRO94 (AS DESIGNED)
LEGACY RIDGE 94
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
51,793
S288
S398
$2,479
S943
SO
$3,422
Requirements
C-M,
Energy Solutions
As Designed
$1,750
$269
$398
$2,416
$943
$0
$3,359
C4405.3 Performance-based compliance passes by 2.5%
R402.4.12 Air Leakage Testing Air sealing is 6 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 2.5%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
7122119 at 7:43 AM
Ekotrope RATER -Version 3.1.0.2217
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
6801 PULASKI CT
, Ni -V P
CARMEL, IN 46033
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 6 ACH50
Window U -Value: 0.31, SHGC: 0.31
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 324 CFM @ 25Pa (5.951100 s.f.)
Total Duct Leakage 432.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 7122119 at 7:43 AM
Ekotrope RATER - Version 3.1.0.2217
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
6861 PULASKI CT TSI Energy Solutions
CARMEL, IN 46633 Matthew Timmons
Model: 3566 RIVIERA C
Community: LEGACY RIDGE 94 Builder
LENNAR HOMES
LR694 (AS DES IG NED)
LEGACY RIDGE 94
General Building Information
Conditioned Area (sq ft) 5,446
Conditioned Volume (cubic ft) 48,468
Insulated Shell Area (sq ft) 9,567
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT(1,712 s.f., 174 ft. exterior perimeter)
R-6 perimeter insulation, R-6 under slab insulation.
Framed Floor
El Name: OVER GARAGE (4 28 s.f.)
R-6 continuous insulation, R-38 cavity insulation
Insulation Grade: I
El Name: OVER AMBIENT (14 s.f.)
R-6 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 131, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.66
Feet from top of wall to top of insulation: 6, Feet from top of wall to bottom of insulation: 4
E[ Name: CONDIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.66
Feet from top of wall to top of insulation: 6, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (2,387 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property organization
6861 PULASKI CT TSI Energy Solutions
CARMEL, IN 46633 Matthew Timmons
Model: 3560 RIVIERA C
Community: LEGACY RIDGE 94 Builder
LENNAR HOMES
LR094 (AS DES IG NED)
LEGACY RIDGE 94
El Name: CONDIAMB 2X6 (270 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (387 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (218 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (270 s.f.)
R: 13.575
Name: CONDIGAR (43 s.f.)
R: 10.876
Name: CONDIATTIC (58 s.f.)
R: 10.876
Roof
El Name: SECOND (2,154 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
C",
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization Inspection Status
6801 PULASKI CT TSI Energy Solutions Results are projected
CARMEL, IN 46033 Matthew Timmons
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94 Builder
LENNAR HOMES
LR094 (AS DESIGNED)
LEGACY RIDGE 94
E] Name: FRONT (127 s.f.), U:0.310, SHGC: 0.29, Orientation: EAST
E] Name: BACK (174 s.f.), U:0.310, SHGC: 0.31, Orientation: WEST
El Name: BACK 2X6 (77 s.f.), U:0.310, SHGC: 0.31, Orientation: WEST
El Name: BACK 2X6 GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST
El Name: RIGHT SIDE (83 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
El Name: RIGHT SIDE BSMT (16 s.f.), U:0.490, SHGC: 0.66, Orientation: NORTH
11 Name: LEFT SIDE (59 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH
11 Name: LEFT BSMT (16 s.f.), U:0.490, SHGC: 0.66, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE
E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
El Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested 3
House is air -sealed as to achieve 4,841 CFM50 (6.00 AC H50) or less at final blower -door test.
Energy Code Inspection Checklist
Property
6801 PULASKI CT
CARMEL, IN 46033
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94
LR094 (AS DES IG NED)
LEGACY RIDGE 94
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Infiltration Requirements for IECC in Climate Zone 5
Inspection Status
Results are projected
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 324 CFM @ 25 Pa (5.95 / 100 s.f.)
Total Duct Leakage specified as 432.0 CFM @ 25Pa (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage t= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization Inspection Status
6801 PULASKI CT
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: 3500 RIVIERA C
Depth Below Grade Perimeter
Community: LEGACY RIDGE 94
Builder
CONDIAMB R-11 Draped, 4Pt
LENNAR HOMES
LRO94 (AS DESIGNED)
Exposed Exterior
LEGACY RIDGE 94
CONDIGAR R-11 Draped, 4Pt
General Building Information
8 43
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
5;446
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu. ft.]
48;408
Total Units in Building
1
Residence Type
Single family detached
Floor Number
-
Model
3500 RIVIERA C
Community
LEGACY RIDGE 94
Climate Zone
5A
C-M,
Energy Solutions
Foundation Wall
Name Library Type
Height Above Grade
Depth Below Grade Perimeter
Location
Enclosing
CONDIAMB R-11 Draped, 4Pt
1
8 131
Exposed Exterior
Conditioned Space
CONDIGAR R-11 Draped, 4Pt
1
8 43
Exposed Exterior
Conditioned Space
Foundation Wall Library List
Name Feet From Wall Top To
Feet From Wall Top To
Is Fully Insulated Continuous R -value
Cavity R -value Effective Insulation R -
Continuous Insulation
Continuous Insulation
value
Top
Bottom
R-11 Draped_ Oft D
4
No N?A
NIA
11.00
Slab
Name Library Type
Perimeter Floor Grade
Carpet R Exposed Surface
Masonry Area
Area Location
Enclosing
BSMT Uninsulated
174 Below Grade 0 0 1,712.0 R2 Exposed Exterior
Conditioned
Space
Slab Library Lis
Name Wall Construction
Slab Completel Underslab Perimeter Perimeter
Thermal Break
Effective R -value
Type
Insulated. Insulation
Width [ft] Insulation Depth [ft] Insulation R Value
Uninsulated Wood Frame/ Other
No
0 0 0
No
D.00
1
Building Summary
Property
Organization
Inspection Status
C-MEnergy Solutions
6801 PULASKI CT
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: 3500 RIVIERA C
Library Type
Surface Area
Location
Community: LEGACY RIDGE 94
Builder
G1 R-13, R-3.0
LENNAR HOMES
Exposed Exterior
CONDIATTIC
LRO94 (AS DESIGNED)
58.0 fF
Unconditioned, attached garage
CONDIGAR
LEGACY RIDGE 94
G1 R-13, OSB
ramed Floor
Unconditioned, attached garage
Name Library Type
Carpet R
Floor Grade
Surface Area Location
OVER AMBIENT R-38, GR1
1.23
Above Grade
14.0 tt' Exposed Exterior
OVER GARAGE R-38, GR1
1.23
Above Grade
428.0 tt' Unconditioned, attached
G1 R-13, R-3.0
13.575
garage
Framed Floor Library List
Name
Effective R -value
-'•s :»
33.825
Rim Joist
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-13, R-3.0
270.0 fF
Exposed Exterior
CONDIATTIC
G1 R-13, OSB
58.0 fF
Unconditioned, attached garage
CONDIGAR
G1 R-13, OSB
43.0 fF
Unconditioned, attached garage
Rim Joist Library List
Name
Effective Insulation R -value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
Name Library Type
CONDIAMB G1 R-13 BATT, R-3.0
:ONDIAMB 2X6 G1 R-19. R-3.0 2X6
Surface Calor
Medium
Medium
Surface Area
Location
2,387.0 HY Exposed Exterior
270.0 ft' Exposed Exterior
Building Summary
Property Organization
6801 PULASKI CT TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94 Builder
LENNAR HOMES
LRO94 (AS DESIGNED)
LEGACY RIDGE 94
Name Library Type
Inspection Status
Results are projected
Surface Calor
Surface Area
C-MEnergy Solutions
Location
CONDIATTIC G1 R-13 BATT, R-3 -0
Medium
278.0 fts
Attic
CONDIGAR G1 R-13 Gar Walls
Medium
387.0 P['
Unconditioned, attached garage
Wall Library List
Name Effective R value
G1 R-13 BATT, R-3.0 15.12
G1 R-13 Gar Walls 11.141
G1 R-19, R-3.0 2X6 20217
Glazing
Name Library Type Wall Assignment Foundation Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Hottom
BACK U-.31, SHGC-.31 CONDIAMB
0
0
0
West
174.0 R2
BACK 2X6 11-.31, SHGG.31 CONDIAMB 2X6
0
0
0
West
77.0 fF
BACK 2X6 GD U-29, SHGC-.33 CONDIAMB 2X6
0
0
0
West
18.0 f,
FRONT 11-.31, SHGG29 CONDIAMB
0
0
0
East
127.0 ft2
LEFT BSMT U -d9, SHGC-.66 CONDIAMB
0
0
❑
South
16.0 ft'
LEFT SIDE U-.32, SHGG.31 CONDIAMB
0
0
0
South
59.0 ftp
RIGHT SIDE U-.32, SHGC-.31 CONDIAMB
0
0
0
North
83.0 ft'
RIGHT SIDE BSMT IJ -A9, 3HGC-.66 CONDIAMB
0
0
0
North
16.0 fF
Building Summary
Property
Organization
Inspection Status
6801 PULASKI CT
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94
Builder
LENNAR HOMES
LRO94 (AS DESIGNED)
LEGACY RIDGE 94
FGlazing Library List
Name
Shg c
U {actor
U-29, SHGC-.33
0.33
0290
U-.31, SHGC-29
029
0.310
U-.31, SHGC-.31
0.31
0.310
U-.32, SHGC-.31
0.31
0.320
U-49, SHGC-.66
0.66
0.490
Skylight
Skylight Library List
Opaque Door
C-M,
Energy Solutions
Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location
Assignment Absorptanoe
FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 fF Exposed Exterior
GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 M Exposed Exterior
Opaque Door Library List
Name Effective U -factor
Steel Door 0.182
4
Building Summary
Property
6801 PULASKI CT
CARMEL, IN 46033
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94
LRO94 (AS DESIGNED)
LEGACY RIDGE 94
FRoof Insulation
Name Library Typ
SECOND R-38 Blown. GR1
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
irea Gtay or ConCrete Root
P.f.] 'riles
2,154 No
Roof Insulation Library List
Name Has Radiant Barrier
IR-38 Blown, GR1 No
Whale House Infiltration
Infiltration Measurement Type
6 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
None Present
38.268
4
C-M,
Energy Solutions
it
Medium 2,154.0 T Attic
■
Lighting
°I Interior Fluorescent °I Interior LED Lighting °I Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent °I Garage LED Lighting
Lighting Lighting Lighting
0 100 0 100 C 100
Onsite Generation
None Present
.01
Building Summary
Property
6801 PULASKI CT
CARMEL, IN 46033
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94
LR094 (AS DESIGNED)
LEGACY RIDGE 94
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
nsite Generation Library List I
None
Solar Generation
Solar Generation Library List
None Present
C-M,
Energy Solutions
Conditioning Equipment
Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location
Air conditioner (2) CA13NA042
0% 100% 0% Conditioned Space
Fuel -fired air 915SA48080517
100% o% 0% Conditioned Space
distribution (1)
PSC (Single Speed)
Water Heating (3) RE350`
0% 0% 100% Conditioned Space
Equipment Type: 915SA48080SI
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
946
E uipment Type: CA13NA042
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Electric
Forced Air
PSC (Single Speed)
13 SEER
46
61
Building Summary
Property
6801 PULASKI CT
CARMEL, IN 46033
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94
LRO94 (AS DESIGNED)
LEGACY RIDGE 94
quipment Type:
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity {gal.]
Hot Water Capacity [kBtulh]
Recovery Efficiency
RE350*
Distribution System
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
❑.98
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution (1 )
Cooling Equipment
Air conditioner (2)
Sq. Feet Served
5446
# Return Grilles
4
Supply Duct R Value
30
Return Duct R Value
20
Supply Duct Area r]
1470.42
Return Duct Area [ftp]
1089.2
Leakage to Outdoors
324 CFM @ 25Pa (5.951 100 s.f.)
Total Leakage
432
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Conditioned Space
Percent Supply Area
60
Percent Return Area
60
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
40
Percent Return Area
40
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
'-Ceiling Fan ��Ml
Has Ceiling Fan No
Cfm Per Watt 100
C-M,
Energy Solutions
7
Building Summary
Property
6801 PULASKI CT
CARMEL, IN 46033
Model: 3500 RIVIERA C
Community: LEGACY RIDGE 94
LRO94 (AS DESIGNED)
LEGACY RIDGE 94
ater Distribution
I
ter Fixture Type
e Default Hot Water Pipe Length
t Water Pipe Length [ft]
Least R3 Pipe Insulation?
t Water Recirculation System?
circulation System Pipe Loop Length [ft]
in Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Standard
No
100
No
No
30
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�