Loading...
HomeMy WebLinkAbout19080020 Energy AuditIECC 2009 Performance Compliance Property 6801 PULASKI CT CARMEL, IN 46033 Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 LRO94 (AS DESIGNED) LEGACY RIDGE 94 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance 51,793 S288 S398 $2,479 S943 SO $3,422 Requirements C-M, Energy Solutions As Designed $1,750 $269 $398 $2,416 $943 $0 $3,359 C4405.3 Performance-based compliance passes by 2.5% R402.4.12 Air Leakage Testing Air sealing is 6 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 2.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 7122119 at 7:43 AM Ekotrope RATER -Version 3.1.0.2217 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 6801 PULASKI CT , Ni -V P CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U -Value: 0.31, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 324 CFM @ 25Pa (5.951100 s.f.) Total Duct Leakage 432.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 7122119 at 7:43 AM Ekotrope RATER - Version 3.1.0.2217 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 6861 PULASKI CT TSI Energy Solutions CARMEL, IN 46633 Matthew Timmons Model: 3566 RIVIERA C Community: LEGACY RIDGE 94 Builder LENNAR HOMES LR694 (AS DES IG NED) LEGACY RIDGE 94 General Building Information Conditioned Area (sq ft) 5,446 Conditioned Volume (cubic ft) 48,468 Insulated Shell Area (sq ft) 9,567 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT(1,712 s.f., 174 ft. exterior perimeter) R-6 perimeter insulation, R-6 under slab insulation. Framed Floor El Name: OVER GARAGE (4 28 s.f.) R-6 continuous insulation, R-38 cavity insulation Insulation Grade: I El Name: OVER AMBIENT (14 s.f.) R-6 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 131, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.66 Feet from top of wall to top of insulation: 6, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.66 Feet from top of wall to top of insulation: 6, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (2,387 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property organization 6861 PULASKI CT TSI Energy Solutions CARMEL, IN 46633 Matthew Timmons Model: 3560 RIVIERA C Community: LEGACY RIDGE 94 Builder LENNAR HOMES LR094 (AS DES IG NED) LEGACY RIDGE 94 El Name: CONDIAMB 2X6 (270 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (387 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIATTIC (218 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (270 s.f.) R: 13.575 Name: CONDIGAR (43 s.f.) R: 10.876 Name: CONDIATTIC (58 s.f.) R: 10.876 Roof El Name: SECOND (2,154 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 6801 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 Builder LENNAR HOMES LR094 (AS DESIGNED) LEGACY RIDGE 94 E] Name: FRONT (127 s.f.), U:0.310, SHGC: 0.29, Orientation: EAST E] Name: BACK (174 s.f.), U:0.310, SHGC: 0.31, Orientation: WEST El Name: BACK 2X6 (77 s.f.), U:0.310, SHGC: 0.31, Orientation: WEST El Name: BACK 2X6 GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST El Name: RIGHT SIDE (83 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH El Name: RIGHT SIDE BSMT (16 s.f.), U:0.490, SHGC: 0.66, Orientation: NORTH 11 Name: LEFT SIDE (59 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH 11 Name: LEFT BSMT (16 s.f.), U:0.490, SHGC: 0.66, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER El Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested 3 House is air -sealed as to achieve 4,841 CFM50 (6.00 AC H50) or less at final blower -door test. Energy Code Inspection Checklist Property 6801 PULASKI CT CARMEL, IN 46033 Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 LR094 (AS DES IG NED) LEGACY RIDGE 94 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Infiltration Requirements for IECC in Climate Zone 5 Inspection Status Results are projected 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 324 CFM @ 25 Pa (5.95 / 100 s.f.) Total Duct Leakage specified as 432.0 CFM @ 25Pa (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage t= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 6801 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA C Depth Below Grade Perimeter Community: LEGACY RIDGE 94 Builder CONDIAMB R-11 Draped, 4Pt LENNAR HOMES LRO94 (AS DESIGNED) Exposed Exterior LEGACY RIDGE 94 CONDIGAR R-11 Draped, 4Pt General Building Information 8 43 Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 5;446 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 48;408 Total Units in Building 1 Residence Type Single family detached Floor Number - Model 3500 RIVIERA C Community LEGACY RIDGE 94 Climate Zone 5A C-M, Energy Solutions Foundation Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4Pt 1 8 131 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4Pt 1 8 43 Exposed Exterior Conditioned Space Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R -value Cavity R -value Effective Insulation R - Continuous Insulation Continuous Insulation value Top Bottom R-11 Draped_ Oft D 4 No N?A NIA 11.00 Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Masonry Area Area Location Enclosing BSMT Uninsulated 174 Below Grade 0 0 1,712.0 R2 Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame/ Other No 0 0 0 No D.00 1 Building Summary Property Organization Inspection Status C-MEnergy Solutions 6801 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA C Library Type Surface Area Location Community: LEGACY RIDGE 94 Builder G1 R-13, R-3.0 LENNAR HOMES Exposed Exterior CONDIATTIC LRO94 (AS DESIGNED) 58.0 fF Unconditioned, attached garage CONDIGAR LEGACY RIDGE 94 G1 R-13, OSB ramed Floor Unconditioned, attached garage Name Library Type Carpet R Floor Grade Surface Area Location OVER AMBIENT R-38, GR1 1.23 Above Grade 14.0 tt' Exposed Exterior OVER GARAGE R-38, GR1 1.23 Above Grade 428.0 tt' Unconditioned, attached G1 R-13, R-3.0 13.575 garage Framed Floor Library List Name Effective R -value -'•s :» 33.825 Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-13, R-3.0 270.0 fF Exposed Exterior CONDIATTIC G1 R-13, OSB 58.0 fF Unconditioned, attached garage CONDIGAR G1 R-13, OSB 43.0 fF Unconditioned, attached garage Rim Joist Library List Name Effective Insulation R -value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 Name Library Type CONDIAMB G1 R-13 BATT, R-3.0 :ONDIAMB 2X6 G1 R-19. R-3.0 2X6 Surface Calor Medium Medium Surface Area Location 2,387.0 HY Exposed Exterior 270.0 ft' Exposed Exterior Building Summary Property Organization 6801 PULASKI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 Builder LENNAR HOMES LRO94 (AS DESIGNED) LEGACY RIDGE 94 Name Library Type Inspection Status Results are projected Surface Calor Surface Area C-MEnergy Solutions Location CONDIATTIC G1 R-13 BATT, R-3 -0 Medium 278.0 fts Attic CONDIGAR G1 R-13 Gar Walls Medium 387.0 P[' Unconditioned, attached garage Wall Library List Name Effective R value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 Glazing Name Library Type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Hottom BACK U-.31, SHGC-.31 CONDIAMB 0 0 0 West 174.0 R2 BACK 2X6 11-.31, SHGG.31 CONDIAMB 2X6 0 0 0 West 77.0 fF BACK 2X6 GD U-29, SHGC-.33 CONDIAMB 2X6 0 0 0 West 18.0 f, FRONT 11-.31, SHGG29 CONDIAMB 0 0 0 East 127.0 ft2 LEFT BSMT U -d9, SHGC-.66 CONDIAMB 0 0 ❑ South 16.0 ft' LEFT SIDE U-.32, SHGG.31 CONDIAMB 0 0 0 South 59.0 ftp RIGHT SIDE U-.32, SHGC-.31 CONDIAMB 0 0 0 North 83.0 ft' RIGHT SIDE BSMT IJ -A9, 3HGC-.66 CONDIAMB 0 0 0 North 16.0 fF Building Summary Property Organization Inspection Status 6801 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 Builder LENNAR HOMES LRO94 (AS DESIGNED) LEGACY RIDGE 94 FGlazing Library List Name Shg c U {actor U-29, SHGC-.33 0.33 0290 U-.31, SHGC-29 029 0.310 U-.31, SHGC-.31 0.31 0.310 U-.32, SHGC-.31 0.31 0.320 U-49, SHGC-.66 0.66 0.490 Skylight Skylight Library List Opaque Door C-M, Energy Solutions Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assignment Absorptanoe FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 fF Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 M Exposed Exterior Opaque Door Library List Name Effective U -factor Steel Door 0.182 4 Building Summary Property 6801 PULASKI CT CARMEL, IN 46033 Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 LRO94 (AS DESIGNED) LEGACY RIDGE 94 FRoof Insulation Name Library Typ SECOND R-38 Blown. GR1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected irea Gtay or ConCrete Root P.f.] 'riles 2,154 No Roof Insulation Library List Name Has Radiant Barrier IR-38 Blown, GR1 No Whale House Infiltration Infiltration Measurement Type 6 ACH at 50 Pa Blower -door tested Mechanical Ventilation None Present 38.268 4 C-M, Energy Solutions it Medium 2,154.0 T Attic ■ Lighting °I Interior Fluorescent °I Interior LED Lighting °I Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent °I Garage LED Lighting Lighting Lighting Lighting 0 100 0 100 C 100 Onsite Generation None Present .01 Building Summary Property 6801 PULASKI CT CARMEL, IN 46033 Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 LR094 (AS DESIGNED) LEGACY RIDGE 94 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES nsite Generation Library List I None Solar Generation Solar Generation Library List None Present C-M, Energy Solutions Conditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location Air conditioner (2) CA13NA042 0% 100% 0% Conditioned Space Fuel -fired air 915SA48080517 100% o% 0% Conditioned Space distribution (1) PSC (Single Speed) Water Heating (3) RE350` 0% 0% 100% Conditioned Space Equipment Type: 915SA48080SI Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSC (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 E uipment Type: CA13NA042 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Electric Forced Air PSC (Single Speed) 13 SEER 46 61 Building Summary Property 6801 PULASKI CT CARMEL, IN 46033 Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 LRO94 (AS DESIGNED) LEGACY RIDGE 94 quipment Type: Fuel Type Distribution Type Hot Water Efficiency Tank Capacity {gal.] Hot Water Capacity [kBtulh] Recovery Efficiency RE350* Distribution System Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 ❑.98 Distribution Type Forced Air Heating Equipment Fuel -fired air distribution (1 ) Cooling Equipment Air conditioner (2) Sq. Feet Served 5446 # Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 20 Supply Duct Area r] 1470.42 Return Duct Area [ftp] 1089.2 Leakage to Outdoors 324 CFM @ 25Pa (5.951 100 s.f.) Total Leakage 432 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct t Duct Location Conditioned Space Percent Supply Area 60 Percent Return Area 60 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 40 Percent Return Area 40 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ '-Ceiling Fan ��Ml Has Ceiling Fan No Cfm Per Watt 100 C-M, Energy Solutions 7 Building Summary Property 6801 PULASKI CT CARMEL, IN 46033 Model: 3500 RIVIERA C Community: LEGACY RIDGE 94 LRO94 (AS DESIGNED) LEGACY RIDGE 94 ater Distribution I ter Fixture Type e Default Hot Water Pipe Length t Water Pipe Length [ft] Least R3 Pipe Insulation? t Water Recirculation System? circulation System Pipe Loop Length [ft] in Water Heat Recovery? Clothes Dryer Fuel Type Cef Field utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Standard No 100 No No 30 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year "M � C-M, Energy Solutions ,�