Loading...
HomeMy WebLinkAbout19080020 Site PlanS T 0 E P P E L W E R T H ALWAYS ON 7965 East 106th Street, Fishers, IN 46038-2505 phone: 317.849.5935 fax: 317.849.5942 69.3AB a 100.00 a XX.X PROPOSED GRADE PER PLAN 1 70.4AB S.S.D. _ 15' D.&U.E N/A f SANITARY SEWER 1,500 f STORM SEWER W SOD TO HERE W 3/4" WATER CONNECTION rn m SWALE 0 SANITARY MANHOLE �J STORM MANHOLE ■ CURB INLET L10 � MH 719 LO EMERGENCY FLOOD ROUTE 0 0 0 73.1 N L0 DRAINAGE UTILITY & N SANITARY SEWER EASEMENT B. L. 18.00' 20.00' M.F.F.E. MINIMUM FINISHED FLOOR 0o COVERED 0 o ELEVATION M. L. A. G. 6 PATIO `� GRADE (FLOOD PROTECTION) 73.1 MINIMUM FLOOD PROTECTION 32.00' T.O.W. 71.8A6 20.0' MODEL=RIVIERA C 30.0' F.F.ELEV.= 774.97 40 T.O.W.= 773.77 r� N BSMT.= 765.10 M 10.00' (RH)c f 0 73.1 0 1 5.0' GAR. 0 773.10 3.04' 05 CONC. PORCH* 0o DRIVE 72.5A6 19.6' 11.33' 0 o 0.38' 25.0' � wo 20' 20.75' N B.L. MH 20' D.U.&S. 718 SSW 217' T.C.= 770.50 90 N 73.1 AS BUILT o 0 12.0' 69.5A8 C. 5' TREE ESMT 71.3AB 5'SW 100.00 aPULASKI EEE'_ 009 COURT W W ^' 1 O N Z 5'SW W PORCH DETAIL 0.42 * PORCH M N N 8.79' N , N 5.25' 2.33' a 2.33 � 0 0 0 BENCHMARK TOP OF CASTING = 774.68 LOT 94 THE RIDGE AT THE LEGACY SECTION FOUR INST. #2018007311 P.C. #5, SLIDE #803 ZONING: PUD 5' MINIMUM SIDE YARD 20' MINIMUM AGGREGATE 20' MINIMUM REAR YARD `0 a 7 71.77 JOB ID RLEG4.94 CONTROL# 88453 LEN 6801 PULASKI COURT CARMEL, IN 46033 199 = 30' LOT AREA:15,600 Sq. Ft. M.F.F.E.= 773.40 M.L.A.G.= 772.90 M.F.P.G..= 772.90 LEGEND: f 1,124± XX.X PROPOSED GRADE PER PLAN XX.XAB AS BUILT GRADE S.S.D. _ _ SUB—SURFACE DRAIN N/A f SANITARY SEWER 1,500 f STORM SEWER W WATER MAIN W 3/4" WATER CONNECTION ° ° < SWALE • SANITARY MANHOLE �J STORM MANHOLE ■ CURB INLET FIRE HYDRANT MH 719 EMERGENCY FLOOD ROUTE T.C.= 774.68 AS BUILT D.&U.E DRAINAGE & UTILITY EASEMENT D.U.&S.S.E. DRAINAGE UTILITY & SANITARY SEWER EASEMENT B. L. BUILDING LINE M.F.F.E. MINIMUM FINISHED FLOOR ELEVATION M. L. A. G. MINIMUM LOWEST ADJACENT GRADE (FLOOD PROTECTION) M.F.P.G. MINIMUM FLOOD PROTECTION GRADE (FLOOD PROTECTION) T.O.W. TOP OF WALL ALL UNDERGROUND SEWERS AND UTILITIES SHOWN ARE PLOTTED BY SCALE FROM "RECORD DRAWINGS" FURNISHED BY ENGINEER. x,\1111111111// *1 100*SSOEP,o�c''%, "G\STERE _Q: No. =_ ::80040474:' _ _= STATE OF /^/DIANP �Z, SOD: 1,124± Sq. Yd. APRON: SEEDING: 1,500 f Sq. Ft. N/A f SEED IN EASEMENT. 1,500 f Sq. Ft. NOTE: THIS DRAWING IS NOT INTENDED TO BE CONC. DRIVEWAY. 1,034 f S Ft. Sq. REPRESENTED AS A RETRACEMENT OR ORIGINAL PRIVATE WALK: 169 f Sq Ft BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATION REPORT. PUBLIC WALK: 440 f Sq. Ft. APRON: 94 f Sq. Ft. ADDITIONAL SOD TO: N/A f Sq. Yd. REAR EASEMENT HANDICAP RAMPS: 0 SIQNA7UREe DAIEe SGNA7URE REPRESEN75 CONFIRMA71ON OF RECOPT OF PLOT PLAN BY CUSTOMER 07/27/19 CEJ *K.Whambelowo. Call bet= you dig.