HomeMy WebLinkAbout19080020 Site PlanS T 0 E P P E L W E R T H
ALWAYS ON
7965 East 106th Street, Fishers, IN 46038-2505
phone: 317.849.5935 fax: 317.849.5942
69.3AB a
100.00 a
XX.X PROPOSED GRADE PER PLAN
1
70.4AB
S.S.D. _
15' D.&U.E
N/A f
SANITARY SEWER
1,500 f
STORM SEWER
W
SOD TO HERE
W
3/4" WATER CONNECTION
rn
m
SWALE
0
SANITARY MANHOLE
�J
STORM MANHOLE
■
CURB INLET
L10
�
MH
719
LO
EMERGENCY FLOOD ROUTE
0
0
0
73.1 N
L0
DRAINAGE UTILITY &
N
SANITARY SEWER EASEMENT
B. L.
18.00' 20.00'
M.F.F.E.
MINIMUM FINISHED FLOOR
0o COVERED 0
o
ELEVATION
M. L. A. G.
6 PATIO `�
GRADE (FLOOD PROTECTION)
73.1
MINIMUM FLOOD PROTECTION
32.00'
T.O.W.
71.8A6
20.0' MODEL=RIVIERA C 30.0'
F.F.ELEV.= 774.97
40 T.O.W.= 773.77
r�
N BSMT.= 765.10 M 10.00'
(RH)c f
0
73.1 0
1
5.0'
GAR.
0 773.10
3.04' 05 CONC.
PORCH* 0o DRIVE
72.5A6
19.6'
11.33'
0
o 0.38' 25.0'
�
wo
20'
20.75' N
B.L.
MH
20'
D.U.&S.
718
SSW
217'
T.C.= 770.50
90 N 73.1
AS BUILT
o 0 12.0'
69.5A8
C.
5' TREE ESMT
71.3AB
5'SW 100.00
aPULASKI
EEE'_
009 COURT
W W
^' 1
O N
Z
5'SW
W
PORCH DETAIL
0.42 * PORCH
M
N N 8.79' N , N 5.25'
2.33' a 2.33 �
0 0 0
BENCHMARK
TOP OF CASTING = 774.68
LOT 94
THE RIDGE AT
THE LEGACY
SECTION FOUR
INST. #2018007311
P.C. #5, SLIDE #803
ZONING: PUD
5' MINIMUM SIDE YARD
20' MINIMUM AGGREGATE
20' MINIMUM REAR YARD
`0 a
7
71.77
JOB ID RLEG4.94
CONTROL# 88453 LEN
6801 PULASKI COURT
CARMEL, IN 46033
199 = 30'
LOT AREA:15,600 Sq. Ft.
M.F.F.E.= 773.40
M.L.A.G.= 772.90
M.F.P.G..= 772.90
LEGEND:
f
1,124±
XX.X PROPOSED GRADE PER PLAN
XX.XAB AS BUILT
GRADE
S.S.D. _
_ SUB—SURFACE DRAIN
N/A f
SANITARY SEWER
1,500 f
STORM SEWER
W
WATER MAIN
W
3/4" WATER CONNECTION
° ° <
SWALE
•
SANITARY MANHOLE
�J
STORM MANHOLE
■
CURB INLET
FIRE HYDRANT
MH
719
EMERGENCY FLOOD ROUTE
T.C.= 774.68
AS BUILT D.&U.E
DRAINAGE &
UTILITY EASEMENT
D.U.&S.S.E.
DRAINAGE UTILITY &
SANITARY SEWER EASEMENT
B. L.
BUILDING LINE
M.F.F.E.
MINIMUM FINISHED FLOOR
ELEVATION
M. L. A. G.
MINIMUM LOWEST ADJACENT
GRADE (FLOOD PROTECTION)
M.F.P.G.
MINIMUM FLOOD PROTECTION
GRADE (FLOOD PROTECTION)
T.O.W.
TOP OF WALL
ALL UNDERGROUND SEWERS AND UTILITIES
SHOWN ARE PLOTTED BY SCALE FROM
"RECORD DRAWINGS" FURNISHED BY ENGINEER.
x,\1111111111//
*1 100*SSOEP,o�c''%,
"G\STERE
_Q: No.
=_
::80040474:'
_ _=
STATE OF
/^/DIANP �Z,
SOD:
1,124±
Sq. Yd.
APRON:
SEEDING:
1,500 f
Sq. Ft.
N/A f
SEED IN EASEMENT.
1,500 f
Sq. Ft.
NOTE: THIS DRAWING IS NOT INTENDED TO BE
CONC. DRIVEWAY.
1,034 f
S Ft.
Sq.
REPRESENTED AS A RETRACEMENT OR ORIGINAL
PRIVATE WALK:
169 f
Sq Ft
BOUNDARY SURVEY, A ROUTE SURVEY OR A
SURVEYOR LOCATION REPORT.
PUBLIC WALK:
440 f
Sq. Ft.
APRON:
94 f
Sq. Ft.
ADDITIONAL SOD TO:
N/A f
Sq. Yd.
REAR EASEMENT
HANDICAP RAMPS:
0
SIQNA7UREe
DAIEe
SGNA7URE REPRESEN75 CONFIRMA71ON OF RECOPT OF PLOT PLAN BY CUSTOMER
07/27/19 CEJ
*K.Whambelowo.
Call bet= you dig.