HomeMy WebLinkAboutLEGACY RIDGE 93 - LR 93 (AS DESIGNED)IECC 2009 Performance Compliance Property 6813 PULAKSI CT CARMEL, IN 46033 Model: SOUTHILL C Community: LEGACY RIDGE 93 LR 93 (AS DESIGNED) LEGACY RIDGE 93 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,905 $290 $411 $2,607 $959 $0 $3,565 Requirements C-M, Energy Solutions As Designed $1,906 $269 $411 $2,586 $959 $0 $3,545 C4405.3 Performance-based compliance passes by 0.8% R402.4.12 Air Leakage Testing Air sealing is 6 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 0.8%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 7115119 at 11:58 AM Ekotrope RATER -Version 3.1.0.2213 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 6813 PULAKS1 CT I �J 15-P Pi CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U -Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 328 CFM @ 25Pa (61100 s.f.) Total Duct Leakage 437.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 7115119 at 11:58 AM Ekotrope RATER - Version 3.1.0.2213 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 6813 PULAKSI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL C Community: LEGACY RIDGE 93 Builder LENNAR HOMES LR 93 (AS DESIGNED) LEGACY RIDGE 93 General Building Information Conditioned Area (sq ft) 6,469 Conditioned Volume (cubic ft) 48,294 Insulated Shell Area (sq ft) 10,186 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT(1,951 s.f., 1i ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: AMBIENT (15 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 178, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 31, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (3,204 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (468 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Cade Inspection Checklist Property Organization 6813 PULAKSI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL C Community: LEGACY RIDGE 93 Builder LENNAR HOMES LR 93 (AS DESIGNED) LEGACY RIDGE 93 Name: CONDIGAR (279 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (255 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (314 s.f.) R: 13.575 Name: CONDIGAR (31 s.f.) R: 10.876 Name: CONDIATTIC (31 s.f.) R: 13.575 Roof El Name: MAIN (1,966 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing inspection Status Results are projected El Name: FRONT (138 s.f.), U:0.320, SHGC: 0.28, Orientation: EAST El Name: BACK (210 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST C-M, Energy Solutions 2 Energy Code Inspection Checklist Property C-MEnergy Solutions Organization inspection Status 6813 PULAKSI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL C Community: LEGACY RIDGE 93 Builder LENNAR HOMES LR 93 (AS DESIGNED) LEGACY RIDGE 93 E] Name: BACK BSMT (11 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST E] Name: SLIDER (40 s.f.), U:0.280, SHGC: 0.32, Orientation: WEST El !Name: RIGHT SIDE (82 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH El Name: LEFT SIDE (121 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4,829 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 6813 PULAKSI CT CARMEL, IN 46033 Model: SOUTHILL C Community: LEGACY RIDGE 93 LR 93 (AS DESIGNED) LEGACY RIDGE 93 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Leakage to Outside specified as: 328 CFM @ 25 Pa (6 f 100 s.f.) Total Duct Leakage specified as 437.0 CFM @ 25Pa (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage t= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 6813 PULAKSI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL C Depth Below Grade Perimeter Community: LEGACY RIDGE fig'• Builder CONDIAMB R-11 Draped, 4Pt LENNAR HOMES LR 93 [AS DESIGNED Exposed Exterior LEGACY RIDGE 93 CONDIGAR R-11 Draped, 4Pt General Building Information 7 31 Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 5;469 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 48;294 Total Units in Building 1 Residence Type Single family detached Floor Number Top Model SOUTHILL C Community LEGACY RIDGE 93 Climate Zone 5A C-M, Energy Solutions Foundation Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4Pt 1 7 178 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4Pt 1 7 31 Exposed Exterior Conditioned Space Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R -value Cavity R -value Effective Insulation R - Continuous Insulation Continuous Insulation value Top Bottom R-11 Draped_ Oft D 4 No N?A NIA 11.00 Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Masonry Area Area Location Enclosing BSMT Uninsulated 1 Below Grade 0 0 1,951.0 ft2 Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame/ Other No 0 0 0 No ID. DD 1 Building Summary Property Organization 6813 PULAKSI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL C Surface Calor Community: LEGACY RIDGE 93 Builder CONDIAMB LENNAR HOMES LR 93 [AS DESIGNED 3.204.0 f[' LEGACY RIDGE 93 CONDIAMB 2X6 ramed Floor Medium Name Library Type Ca AMBIENT R-38, GRi G1 R-13 BATT, R-3.0 Medium 255.0 Rs Framed Floor Library List Name Effective R -value R-38, GRi 2 33.825 Rim Joist Name Library Type CONDIAMB G1 R-13, R-3.0 CONDIATTIC G1 R-13, R-3.0 CONDIGAR G1 R-13, OSB Rim Joist Library List Name Effective Insulation R -value G1 R-13, OSB 10.876 G1 R-13. R-3.0 13.575 C-M Energy Solutions Inspection Status Results are projected e Surface Area Location 1.23 Above Grade 15.0 ft' Exposed Exterior 314.0 ft' Exposed Exterior 31.fl fF Attic 31.fl fF Unconditioned, attached garage ali Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-13 BATT, R-3.0 Medium 3.204.0 f[' Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 468.0 f[' Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 255.0 Rs Attic 2 Building Summary Property 6813 PULAKSI CT CARMEL, IN 46033 Model: SOUTHILL C Community: LEGACY RIDGE 93 LR 93 [AS DESIGNED) LEGACY RIDGE 93 Name Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Library Type Inspection Status Results are projected Surface Calor Surface Area C-MEnergy Solutions Location CONDIGAR G1 R-13 Gar Walls Medium 279.0 fts Unconditioned, attached garage Wall Library List Name Effective R -value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 Glazing Name Library Type Wall Assignment Foundation Wall Assignment Overhang Depth Overhang Ft Top To Overhang Ft To Bottom Orientation Surface Area BACK U-.32, SHGG.31 CONDIAMB 0 0 0 West 210.0 Rs BACK BSMT U-.32, SHGC-.31 CONDIAMB 0 0 0 West 11.0 its FRONT U-.32, SHGG28 CONDIAMB 0 0 ❑ East 138.0 ft LEFT SIDE U-.32, SHGG.31 CONDIAMB 0 0 ❑ South 121.0 ft RIGHT SIDE U-.32, SHGG.31 CONDIAMB 0 0 ❑ North 82.0 ft SLIDER U-28, SHGG.32 CONDIAMB 0 0 ❑ West 40.0 f' Glazing Library List Name Shg c U factor U-28, SHGC-.32 0.32 0280 U-.32, SHGC-28 028 0.320 U-.32, SHGC-.31 0.31 0.320 Building Summary Property 6813 PULAKSI CT CARMEL, IN 46033 Model: SOUTHILL C Community: LEGACY RIDGE 53 LR 93 [AS DESIGNED] LEGACY RIDGE 93 kylight Skylight Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Opaque Door �.A FM 0 Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta nce FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 T Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 f' Exposed Exterior Opaque Door Library List Name Effective U -factor 0.182 Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location �.f.] Tiles MAIN R-38 Blown, GR1 9G No Medium 1.966.0 f[s Attic Roof Insulation Library List Name Has Radiant Barrier Effective R -value '•0 �- -I :a l No 38268 4 Building Summary Property 6813 PULAKSI CT CARMEL, IN 46033 Model: SOUTHILL C Community: LEGACY RID: fig'• LR 93 (AS DESIGNED LEGACY RIDGE 93 FWhole House Infiltration Infiltration 6 ACH at 50 Pa Mechanical Ventilation Lighting , °I Interior Fitiorescent Lighting Onsite Generation Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Blower -door tested 4 rang Y. t)senor rmorescem Lighting 100 0 None Present Onsite Generation Library List None Present Solar Generation Solar Generation Library List C-M, Energy Solutions Lighting 1❑0 Building Summary Property Organization Inspection Status 6813 PULAKSI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL C Community: LEGACY RIDG: fig'• Builder LENNAR HOMES LR 93 (AS DESIGNED LEGACY RIDGE 93 onditioning Equipment Name Library Type Pleating Percent Load Cooling Percent Load Air conditioner (2) CA13NA042 0% 100% I Fuel -fired air 912SA48080S17 100% o% distribution (1) IWater Heating (3) RE350` 0% o% 1 Equipment Type: 912SA4808OS17 MJFM=Wu Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 977 Equipment Type: CA13NA042 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 C-M, Energy Solutions r Percent Load Location 0 Conditioned Space ❑ I Conditioned Space 1001 Conditioned Space 61 Building Summary Property 6813 PULAKSI CT CARMEL, IN 46033 Model: SOUTHILL C Community: LEGACY RIDG: fig'• LR 93 [AS DESIGNED LEGACY RIDGE 93 1butivn System tion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area r] ]uct Area [ff] 5 to Outdoors akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 5469 6 30 30 1107.5 1025.4 328 CFM @ 25Pa (61 100 s-1) 437 Post -Construction Yes Conditioned Space 70 70 Attic (well vented; under insulation) 30 30 Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No C-M, Energy Solutions 7 Building Summary Property 6813 PULAKSI CT CARMEL, IN 46033 Model: SOUTHILL C Community: LEGACY RIDGE 93 LR 93 [AS DESIGNED: LEGACY RIDGE 93 ater Distribution Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 125 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 20 Drain Water Heat Recovery? No r othes Dryer elType Electric f 2.32 ld utilization Timer Controls Clothes Washer Label Energy Rating 704 kWh/Year Electric Rate 0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.847 1 mef 0.331 Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Yes Standard 270 kWh Electric No No 709 kWh/Year "M � TSI Energy Solutions ,�