Loading...
HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property 7152 CHERRY CREEK BLVD CARMEL, IN 46033 Model: STOCKBRIDGE Community: THE GROVE AT LEGA( GL196A (AS DESIGNED) THE GROVE AT LEGACY 196A Organization TSI Energy Solutions Devin Sielschott Builder PYATT BUILDERS, LLC Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1.122 S170 S313 $1,605 S780 $0 $2,385 Requirements C-M, Energy Solutions As Designed S1,106 S175 S313 $1,594 S757 SO $2,360 C4405.3 Performance-based compliance passes by 0.7% R402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 0.7%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 6125119 at 10:07 AM Ekotrope RATER - Version 3.1.0.2203 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 7152 CHERRY CREEK BLVD CARMEL, IN 46033 Builder: PYATT BUILDERS, LLC Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U -Value: 0.28, Sll 0.31 Building Features Duct. Supply R-20.0, Return R-15.0 Duct Leakage to Outside 103.0 CFM @ 25Pa Total Duct Leakage 253.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected. I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed. I certify that the address referenced above has been inspectetlrtested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the I ECC cr will be venfied as such by another party. Name Organization Devin Sielschott TSI Energy Solutions Signature: Date: 6125119 at 10:07 AM Ekotrope RATER -Version 3.1.0.2203 2009 l compliance results calculated using Ekotrope RATER's energy and code cnmptance algorithm_ Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh— on this report. Energy Code Inspection Checklist Property Organization 7152 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 Devin Sielschott Model: STOCKBRIDGE Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC GL196A (AS DESIGNED) THE GROVE AT LEGACY 196A General Building Information Conditioned Area (sq ft) 2,267 Conditioned Volume (cubic ft) 23,098 Insulated Shell Area (sq ft) 6,873 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB(1,685 s.f., 156 ft. exterior perimeter) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (2,501 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIGAR (630 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIATTIC (212 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDICOND (160 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property 7152 CHERRY CREEK BLVD CARMEL, IN 46033 Model: STOCKBRIDGE Community: THE GROVE AT LEGA[ GL196A (AS DESIGNED) THE GROVE AT LEGACY 196A Rim Joist None Present Roof Organization TSI Energy Solutions Devin Sielschott Builder PYATT BUILDERS, LLC Name: MAIN (1,685 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (60 s.f.), U:0.280, SHGC: 0.31, Orientation: SOUTH El Name: SLIDER (120 s.f.), U:0.280, SHGC: 0.31, Orientation: NORTH El Name: BACK (168 s.f.), U:0.280, SHGC: 0.31, Orientation: NORTH El Name: LEFT SIDE (109 s.f.), U:0.280, SHGC: 0.31, Orientation: WEST 11 Name: SLIDER (48 s.f.), U:0.280, SHGC: 0.31, Orientation: WEST El Name: RIGHT SIDE (34 s.f.), U:0.280, SHGC: 0.31, Orientation: EAST Skylight None Present Mechanical Ventilation C-M, Energy Solutions 2 Energy Code Inspection Checklist TSI Energy Solutions Property Organization Inspection Status 7152 CHERRY CREEK BLVD TSI Energy Solutions Results are projected CARMEL, IN 46033 Devin Sielschott Model: STOCKBRIDGE Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC GL196A (AS DESIGNED) THE GROVE AT LEGACY 196A ElMechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 24 hrslday, 8 Watts. Mechanical Equipment El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AF UE 0 Air conditioner • Electric • 100% Cooling Load @ 13 SEER Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,925 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 103.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 253.0 CFM @ 25Pa 3 Energy Code Inspection Checklist Property Organization 7152 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 Devin Sielschott Model: STOCKBRIDGE Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC GL196A (AS DESIGNED) THE GROVE AT LEGACY 196A Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 7152 CHERRY CREEK BLVD CARMEL, IN 46033 Model: STOCKBRIDGE Community: THE GROVE AT LEGACY 196A GL196A [AS DESIGNED] THE GROVE AT LEGACY 196A enera?Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq_ ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Foundation Wall Library List Slab Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Builder PYATT BUILDERS, LLC 3 2 2;267 Yes 23;498 1 Duplex; single unit STOCKBRIDGE THE GROVE AT LEGACY 196A 5A None Present None Present Masonry Area C-M, Energy Solutions n SLAB R-10, 1'down, 2' in 156 On Grade 1.23 0 1,665.0 R' Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, 2' in Wood Frame /Other No 2 1 10 No 10.00 Framed Floor None Present 1 Building Summary Property Organization 7152 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 Devin Sielschoft Model: STOCKBRIDGE Community: THE GROVE AT LEGACY 196A Builder G1 R-15 BATT, OSB PYATT BUILDERS, LLC GL196A [AS DESIGNED] CONDIATTIC THE GROVE AT LEGACY 196A Framed Floor Library List None Present Rim Joist Rim Joist Library List _ None Present Wall Inspection Status Results are projected C-M, Energy Solutions Name Library Type Surface Calor Surface Area Location CONDIAMB Exposed Exterior G1 R-15 BATT, OSB Medium 2.501.0 ft' CONDIATTIC Attic G1 R-15 BATT, OSB Medium 212.0 ft' CONDICOND Conditioned Space [Adiabatic] G1 R-22 Dbl Wall Medium 160.0 ft' CONDIGAR Unconditioned, attached garage G1 R-15 Gar Walls Medium 630.0 f[s Wall Library List Name Effective R value G1 R-15 BATT, OSB 13.423 G1 R-15 Gar Walls 11.972 G1 R-22 Dhl Wall 18.407 2 Building Summary Property Organization Inspection Status 7152 CHERRY CREEK BLVD TSI Energy Solutions Results are projected CARMEL, IN 46033 Devin Sielschott Model: STOCKBRIDGE Community: THE GROVE AT LEGACY 196A Builder PYATT BUILDERS, LLC GL196A [AS DESIGNED] THE GROVE AT LEGACY 196A lazing Name Library Type WaIT Assignment Foundation Wall Overhang Depth Overhang Ft To Assignment Top Overhang Ft To Bottom C-MEnergy Solutions Orientation Surface Area BACK U-28, SHGG.31 CONDIAMB ❑ ❑ ❑ North 168.0 fts FRONT U-28, SHGG.31 CONDIAMB ❑ 0 ❑ South 60.0 fF LEFT SIDE U-28, SHGG.31 CONDIAMB 0 0 ❑ West 109.0 R2 RIGHT SIDE U-28, SHGG.31 CONDIAMB 0 0 ❑ East 34.0 ft SLIDER U-28, SHGG.31 CONDIAMB 0 0 0 North 1200.fts SLIDER U-28, SHGG.31 CONDIAMB 0 0 0 West 48.0 fF Glazing Library Li Name Shgc U -factor U-28, SHGC-.31 0.31 0280 Skylight None Present Skylight Library List A JL None Present Opaque Door Name Library Type Wall Assignment Foundation Wall Emi tante Solar Surface Color Surface Area Location Assignment Absorptance FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 f' Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 ft' Exposed Exterior Building Summary Property Organization 7152 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 Devin Sielschott Model: STOCKBRIDGE Community: THE GROVE AT LEGACY 196A Builder PYATT BUILDERS, LLC GL196A [AS DESIGNED] THE GROVE AT LEGACY 1 %A PpOpaque Door Library List Name Effective U -factor Steel Door 0.182 Roof Insulation Name Library Typ ktAIN R-38 Blown. GRI Inspection Status Results are projected C-M, Energy Solutions rArea Clay or Concrete Roof Surface Color Surface Area Location Vt.] Tiles 1,685 No Medium 1.685.0 fls Attic Roof Insulation Library List Name Has Radiant Barrier R-38 Blown, GR1 No Whale House Infiltration Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation Ventilation Type Ventilation Rate�fta! operational hours per day Minute] Exhaust Only 24 24 Lighting Interior Fluorescent Lighting 0 0 38268 Shelter Class 4 Fan Watts Runs once every three Energy Recovery Percent hours 8 Yes 4 Building Summary Property Organization 7152 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 Devin Sielschott Model: STOCKBRIDGE Community: THE GROVE AT LEGACY 196A Builder PYATT BUILDERS, LLC GL196A [AS DESIGNED] THE GROVE AT LEGACY 196A nsite Generation None Present Onsite Generation Library List I None Solar Generation None Present Solar Generation Library List None Present Conditioning Equipmenl Name Air conditioner Fuel4red air distribution Water Heating C-M Energy Solutions Inspection Status Results are projected g Percent LGao Hot water CA13NA036 0% 1 OD% 9125A48060917 100% 0% 0% 0% ENT 50 100 0% 0% 100% Equipment Type: 912SA48060S17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 56 Use default EAE No EAE [kWh] 649 :j Building Summary Property 7152 CHERRY CREEK BLVD CARMEL, IN 46033 Model: STOCKBRIDGE Community: THE GROVE AT LEGACY 196A GL196A [AS DESIGNED] THE GROVE AT LEGACY 196A ■ quipment Type: Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] GA13NA036 Equipment Type: ENT 50 100 Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Organization TSI Energy Solutions Devin Sielschott Builder PYATT BUILDERS, LLC Electric Forced Air PSC (Single Speed) 13 SEER 34.2 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 7152 CHERRY CREEK BLVD CARMEL, IN 46033 Model: STOCKBRIDGE Community: THE GROVE AT LEGACY 196A GL196A [AS DESIGNED] THE GROVE AT LEGACY 196A 1bution System tion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area r] ]uct Area [tt2] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization TSI Energy Solutions Devin Sielschott Builder PYATT BUILDERS, LLC Forced Air Fuel -fired air distribution Air conditioner 2267 2 2❑ 15 612.09 226.7 163 253 Post -Construction Yes Attic (well vented; under insulation) 75 50 Conditioned Space 25 5❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 7152 CHERRY CREEK BLVD CARMEL, IN 46033 Model: STOCKBRIDGE Community: THE GROVE AT LEGACY 196A GL196A [AS DESIGNED] THE GROVE AT LEGACY 196A ater Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? r es Dryer e zation Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmabie thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption FV I Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Builder PYATT BUILDERS, LLC Standard No 25 No No 10 No Electric Timer Controls 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year C-M, Energy Solutions ,�