HomeMy WebLinkAbout8.REFLECTED CEILING PLAN A200REFLECTED CEILING PLAN 1 /8" = 1'-0" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel DATE: 08/15/19 LEGEND 4j EMERGENCY LIGHT EXIT LIGHT FIXTURE FIXTURE NL INDICATES NIGHT ^ LIGHT CIRCUIT LIGHT LOCATION ® LIGHT FIXTURE, 21BK2',LED b LIGHTSWITCH F4 MFG: COOPER LIGHTING STYLE: 2X2 METALUX CRUZE 0 F1 LIGHT FIXTURE, DOWNLIGHT $3 LIGHTSWITCH, MFG: HALO LIGHTING 3-WAY STYLE:4"LED, HC4 SERIES 0 LIG HT F IXTU RE, DOI IGHT b. LIGHTSWITCH, F2 MFG:CONTECH 4-WAY STYLE: 2" LED, R2RM 1­1 LIGHT FIXTURE, LINEAR bo LIGHTSWITCH, F4 WALLWASH DIMMER MFG: LUMENWERX STYLE: 4' LENGTH, VIA2 ARO UC LIGHT FIXTURE, NL NIGHTLIGHT UNDERCABINET LOCATION MFG-HALO STYLE: HU30 36" NOMINAL NEWCEILINGGRID, SUSPENDED, 2'x2' 12 NEW GYPSUM BOARD CEILING CEILING TYPE�x1 CEILING HEIGHHT��� A 2'x TACOUSTICAL CEILING MFG: ARMSTRONG TYPE: DUNE EDGE TYPE: REVEAL GRID: 15/16" NRC RATING: 0.55 FIRE RATING: CLASSA TRIM: ARMSTRONG AXIOM EDGE, 6" (WHERE REQUIRED) ■ AREA NOT IN CONTRACT ❑ AREAOFWORK GENERAL NOTES 1. PROVIDE NEW CEILING GRID AND TILE THROUGHOUT UNLESS NOTED OTHERW ISE. 2. WHERE MULTIPLE SWITCHESARE SHOWN, PROVIDE(1) GANG BOX WITH A SINGLE COVERPLATE. 3. PROVIDE EMERGENCY LIGHTING IN TENANTSPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 4. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY -OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50%OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 5. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. CAN LIGHT FIXTURES TO BE SWITCHED SEPARATELY AND HAVE DIMMERS. 7. ALL EXPOSED ACOUSTICAL CEILING TILE EDGES TO BE FINISHED WITH 4"WHITE AXIOM TRIM UNLESS NOTED OTHERWISE. 8. ALL DEVICES AND COVERS TO BE WHITE. 9. PAINT 1O'BEYOND PERIMETER OF CEILINGS WHERE OPEN DECK IS EXPOSED BEYOND AND WHERE IT TRANSITIONS FROM OPEN DECK TO ACOUSTICAL TILE. PAINT EXPOSED DECK WITH DRYFALL PAINT. 10. ALL DRYWALL CEILINGS TO BE PAINTED Pi UNLESS NOTED OTHERWISE. 11. WHERE PLAN INDICATES EXPOSED DECK AT EXTERIOR WALLS, CONTRACTOR TO INCLUDE PROVIDING, INSTALLING, AND FINISHING THE DRYWALL ABOVE THE WINDOW HEADER AT THE EXTERIOR PERIMETER WALLS AS REQUIRED. 12. ALL BULKHEADS TO BE CONSTRUCTED USING METAL STUDS, NOT CEILING GRID AND WIRE SUPPORTS. 0 a >9 v zv (D n Yl o mg3 J R:i m m ARE CB HE J u 0 n0 m^ 6 aBE �09^ ao _ F z a z v Cg Wig, BP° fc w ut G z 0 E F n m ,GO EEC 0 rILL! ut F N 0 0 w fOD O S z lD z mDID0 SOBE RE)o N ¢ N u 00 w O u F o a N O u a N O N +�+ M t C > � N M £ U rt W U O \\`\\oawalF, S*1111 19600042 p i ST TE DF L C O C /9-t IPNP i O y I u1� REFLECTED CEILING PLAN A200