HomeMy WebLinkAbout8.REFLECTED CEILING PLAN A200REFLECTED CEILING PLAN
1 /8" = 1'-0"
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Camel
DATE: 08/15/19
LEGEND
4j
EMERGENCY LIGHT
EXIT LIGHT
FIXTURE
FIXTURE
NL
INDICATES NIGHT ^
LIGHT CIRCUIT
LIGHT LOCATION
®
LIGHT FIXTURE, 21BK2',LED b
LIGHTSWITCH
F4
MFG: COOPER LIGHTING
STYLE: 2X2 METALUX
CRUZE
0
F1
LIGHT FIXTURE, DOWNLIGHT $3
LIGHTSWITCH,
MFG: HALO LIGHTING
3-WAY
STYLE:4"LED, HC4 SERIES
0 LIG HT F IXTU RE, DOI IGHT b. LIGHTSWITCH,
F2
MFG:CONTECH 4-WAY
STYLE: 2" LED, R2RM
11 LIGHT FIXTURE, LINEAR bo LIGHTSWITCH,
F4 WALLWASH DIMMER
MFG: LUMENWERX
STYLE: 4' LENGTH, VIA2 ARO
UC LIGHT FIXTURE, NL NIGHTLIGHT
UNDERCABINET LOCATION
MFG-HALO
STYLE: HU30 36" NOMINAL
NEWCEILINGGRID,
SUSPENDED, 2'x2'
12 NEW GYPSUM BOARD
CEILING
CEILING TYPE�x1
CEILING HEIGHHT���
A 2'x TACOUSTICAL CEILING
MFG: ARMSTRONG
TYPE: DUNE
EDGE TYPE: REVEAL
GRID: 15/16"
NRC RATING: 0.55
FIRE RATING: CLASSA
TRIM: ARMSTRONG AXIOM EDGE, 6" (WHERE REQUIRED)
■ AREA NOT IN CONTRACT
❑ AREAOFWORK
GENERAL NOTES
1. PROVIDE NEW CEILING GRID AND TILE THROUGHOUT UNLESS
NOTED OTHERW ISE.
2. WHERE MULTIPLE SWITCHESARE SHOWN, PROVIDE(1) GANG BOX
WITH A SINGLE COVERPLATE.
3. PROVIDE EMERGENCY LIGHTING IN TENANTSPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED
IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN
ON PLAN ARE FOR REFERENCE ONLY.
4. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE
ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND
ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
VERIFYING THAT LAY -OUT AND TOTAL WATTAGE MEETS ASHRAE
90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE
USE OF EACH SPACE. OVER 50%OF THE LIGHTING WILL BE
REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MET.
5. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN
OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND
INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE.
OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT
OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS
DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS
IN OPEN AREAS AS REQUIRED.
6. CAN LIGHT FIXTURES TO BE SWITCHED SEPARATELY AND HAVE
DIMMERS.
7. ALL EXPOSED ACOUSTICAL CEILING TILE EDGES TO BE FINISHED
WITH 4"WHITE AXIOM TRIM UNLESS NOTED OTHERWISE.
8. ALL DEVICES AND COVERS TO BE WHITE.
9. PAINT 1O'BEYOND PERIMETER OF CEILINGS WHERE OPEN DECK IS
EXPOSED BEYOND AND WHERE IT TRANSITIONS FROM OPEN DECK
TO ACOUSTICAL TILE. PAINT EXPOSED DECK WITH DRYFALL
PAINT.
10. ALL DRYWALL CEILINGS TO BE PAINTED Pi UNLESS NOTED
OTHERWISE.
11. WHERE PLAN INDICATES EXPOSED DECK AT EXTERIOR WALLS,
CONTRACTOR TO INCLUDE PROVIDING, INSTALLING, AND
FINISHING THE DRYWALL ABOVE THE WINDOW HEADER AT THE
EXTERIOR PERIMETER WALLS AS REQUIRED.
12. ALL BULKHEADS TO BE CONSTRUCTED USING METAL STUDS, NOT
CEILING GRID AND WIRE SUPPORTS.
0
a
>9
v
zv
(D n
Yl
o mg3
J R:i m
m ARE CB
HE
J
u 0 n0
m^
6
aBE
�09^
ao _
F
z
a
z v
Cg
Wig, BP°
fc
w
ut
G
z
0
E
F
n
m
,GO
EEC
0
rILL! ut
F
N
0
0
w
fOD
O
S
z
lD
z mDID0
SOBE
RE)o
N
¢ N
u 00
w
O
u F
o
a
N
O
u
a
N
O
N
+�+ M
t
C
>
�
N
M
£
U
rt
W U
O
\\`\\oawalF, S*1111
19600042
p i
ST TE DF
L C
O C
/9-t IPNP
i O
y I
u1�
REFLECTED
CEILING PLAN
A200