Loading...
HomeMy WebLinkAboutA000.2ROOF SHINGLES, PER SPECFYPON #LV12X24 OR APPROVED EQUAL \A1;3'-6"\A1;MIN. \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION METAL ROOF, PER SPEC4" TRIM BOARD (TYP.), PER SPEC6" TRIM BOARD, PER SPEC 1214 12141214 1214 1214 JACK SOLDIER COURSE, PER SPEC18"x72" PANEL SHUTTERS, PER SPEC BRICK SOLDIER COURSE, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC BRICK VENEER, PER SPECSTONE SILL, PER SPEC STONE VENEER, PER SPEC BRICK ROWLOCK OVER SOLDIER COURSE BRICK RECESS (5 COURSES) 1214 1214 1214 \A1;7'-6"\A1;7'-0" \A1;3'-1" \A1;3'-0" \A1;3'-1" \A1;3'-0" 7:12 7:1212141214 BRICK SOLDIER COURSE, PER SPEC \A1;14'-7{\H0.75x;\S3#4;}"\PPLATE HT. \A1;R10'-0" \A1;10'-3{\H0.75x;\S7#8;}"\PPLATE HT. 14:12 7:12 7:12 14:12 14:12 SCALE:FRONT ELEVATION1/4" = 1'-0"- \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. \A1;5'-1{\H0.750000x;\S3#4;}" \A1;5'-1{\H0.750000x;\S3#4;}" \A1;22'-0{\H0.750000x;\S3#4;}" \A1;5'-0{\H0.750000x;\S1#2;}"\A1;2'-11" \A1;7'-1" \A1;2'-11" \pxi-4,l4,ql,t3;POT VENT \A1;21'-0" \A1;11'-0" \A1;18'-0" SCALE:ROOF PLAN1/8" = 1'-0"- 7:12 "A"3202ROOF AREA:SQ. FT."B"59ROOF AREA:SQ. FT. 7:12 14:12 14:1214:12 7:12 7:12 7:1214:12 14:12 14:1214:12 14:1214:12 14:12 7:12 14:12 14:12 14:1214:12 3.5:12 14:12 14:1214:12 14:12 14:1214:12 14:12 7:12 7:12 14:127:12 7:12 TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}"\A1;3'-6"\A1;MIN. ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC4" FRIEZE, PER SPEC 1214 123 1/2 STONE WAINSCOT, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPEC BLACKOUT WINDOW, TYP.12148" RAKE BOARD, PER SPEC 4" FRIEZE, PER SPEC4" TRIM BOARD (TYP.), PER SPEC 4" TRIM BOARD (TYP.), PER SPEC6" FASCIA, PER SPEC127 127 1214 1214 \A1;3'-1" \A1;3'-6" 4" CORNER BOARD, PER SPEC HORIZONTAL SIDING, PER SPECBRICK WAINSCOT, PER SPEC SCALE:LEFT ELEVATION1/8" = 1'-0"- TOP OF PLATEROOF SHINGLES, PER SPECWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}"\A1;3'-6" 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC STONE WAINSCOT, \PPER SPECHORIZONTAL SIDING, PER SPECBRICK SOLDIER COURSE, PER SPEC 4" FRIEZE, PER SPEC 123 1/21214 127 127 127 1214 HORIZONTAL SIDING, PER SPECBRICK WAINSCOT, PER SPEC 4" CORNER BOARD, PER SPEC 4" TRIM BOARD (TYP.), PER SPEC \A1;3'-6"\A1;MIN. 8" FASCIA, PER SPEC127127 \A1;3'-1" 8" RAKE, PER SPEC4" FRIEZE, PER SPEC BRICK VENEER, \PPER SPEC SCALE:RIGHT ELEVATION1/8" = 1'-0"- TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" 12141214 12141214 BRICK WAINSCOT, PER SPECHORIZONTAL SIDING, PER SPEC ROOF SHINGLES, PER SPEC8" FASCIA, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC8" FRIEZE, PER SPEC SMOOTH PANEL, PER SPEC6" TRIM BOARD (TYP.), PER SPEC\A1;12'-6{\H0.750000x;\S1#4;}"\PPLATE HT. 4" CORNER BOARD, PER SPEC \A1;12'-6{\H0.75x;\S1#4;}"\PPLATE HT. SCALE:REAR ELEVATION1/8" = 1'-0"- ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3202 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.27 5.34 5.08 49.06 12 0 AT EAVE 6.40 5.34 5.28 50.94 0 76.00 TOTAL (MIN)10.67 10.67 10.36 100.00 3 HIGH - RIDGE VENT 4.27 5.34 5.25 49.87 0 0 42.00 AT EAVE 6.40 5.34 5.28 50.13 0 76.00 TOTAL (MIN)10.67 10.67 10.53 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION EC01 ROOF AREA "B"SQ FTG 59 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.08 0.10 0.28 80.00 0 1 AT EAVE 0.12 0.10 0.07 20.00 0 1.00 TOTAL (MIN)0.20 0.20 0.35 100.00 3 HIGH - RIDGE VENT 0.08 0.10 0.13 64.29 0 0 1.00 AT EAVE 0.12 0.10 0.07 35.71 0 1.00 TOTAL (MIN)0.20 0.20 0.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE PLOTTED: July 17, 2019 / Annie Lee / 3007-IN-TURIN-EC01.DWG A3-EC01 1FB.3Euro Country2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Suzette Schuette3/30/2015 GARAGE RIGHT 3007-Turin TBD LOT 23 04/18/2019 13' 4 1/8" 08/15/19 William Hohlt