HomeMy WebLinkAboutA121 1st Floor Reflected Ceiling PlanCONTACT JENEY HALL AT ESE LEGEND OR LIGHTING: 3179512300 SPECTRUM NEW OR RELOCATED EXISTING TO REMAIN LIGHT 177 COLUMBIALCAT 4, LED � LIGP RHAB LIC SURE, 2'X4', nLIGHT FIXTURE, 2'x2', LED LIGHT FIXTURE, 2'x2' COLUMBIA LCAT 0 FLUORESCENT, PARABOLIC RECESSED LED LIGHT FIXTURE, INTENSE SS6 A® LIGHT FIXTURE, LED PENDANT, OCL CENTRO, COLOR: WHITETEXTURED POWDER COAT ® LIGHT FIXTURE, B ZUMBOTEL 2.5"LINEAR LED, DIRECT/INDIRECT. 6LENGT C NOT USED LIGHT FIXTURE, LED D® PENDANT;TECH LIGHTING BALTO 36" ABSTRACT CHANDELIER. 70OBBLTGM-LED930-277: GUNMETAL LIGHT FIXTURE, LED E® PENDANT; WAG LIGHTING PD-45747-BK E-MC2 47'W LINEAR CHANDELIER; BRUSHED ALUMINUM LIGHT FIXTURE, LED F® PENDANT; VONN VMC31740BLTIANA DUO RING CHANDELIER LIGHT, 24"W, SILVER — -- NOTUSED 0 ® EXITLIGHTFIXTURE ® EXITLIGHTFIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE $N LIGHT SWITCH $ LIGHT SWITCH *N3 LIGHT SWITCH, 3-WAY $3 LIGHT SWITCH, 3-WAY $ND LIGHT SWITCH, DIMMER $, LIGHT SWITCH, DIMMER *NG SWITCH, GARBAGE $G SWITCH, GARBAGE DISPOSAL (ABOVE DISPOSAL COUNTERTOP) i — LIGHTCIRCUIT " . LIGHT CIRCUIT CEILING GRID, SUSPENDED, 2'x2' 17 GYPSUM BOARD CEILING EXPOSED TO DECK RELOCATED DIFFUSER, LAY -IN, 2'x2' RELOCATED DIFFUSER, LAY -IN, 4"M CEILING GRID, ---- SUSPENDED, 2'x2' GYPSUM BOARD CEILING ®DIFFUSER, LAY IN, 2'x2' m DIFFUSER, LAY -IN, 4"X4' NOTE: IF IN GOOD CONDITION, EXSTING H.V.A.C. DEVICES AND CEILING TILE SALVAGED FROM DEMOLITION CAN BE SUBSTTUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/19/19 RELOCATE DIFFUSERS & MECHANICAL DIFFUSER RELOCATION *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION (2) ENLARGED REFLECTED CEILING PLAN = NOT USED A121 CLOUD + LIGHTING TO BE ALTERNATE PRICE 0 1- 4 mmmml GENERAL NOTES I. PROVIDE NEW 2X2 BUILDING STANDARD CEILING GRID AT 9'-0"AFF- TILES TO BE NEW 2x2 ACOUSTICAL LAY IN TILES. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SURE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE, 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASTRAL 90.1, CONTRACTOR MUST NOTIFY SDI, 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH ONE BUTTON OVERRIDE, OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHI N ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, 5. NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. MECHANICAL NOTES I. MECHANICAL WORK IS LIMITED TO A DESIGNBUILDSCOPE ANDS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, ® AREA NOT IN CONTRACT ❑ AREA OF WORK PLAN NOTES R01 CONTROL OPEN AREA, LIBRARY +COPY 120, AND PARALEGAL STATION AREAS LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION UNLESS NOTED OTHERWISE. PROVIDE MULTIPLE SWITCHES AS REQUIRED. R02 IN AREA TO BE EXPOSED TO DECK, REMOVE AS MUCH OF THE EXPOSED CONDUIT, PIPING, JUNCTION BOXES AND PROVIDE RETAUNUSEDEQUIPMENT IN THE CEILING AS POSSIBLE. PROVIDE RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED, CLEAN AS REQUIRED AND LEAVE CONCRETE EXPOSED (NO PAINT). OTRANSITION FROM CEILI NG GRID TO EXPOSED CEILI NG TO BE A 5" R03 WIDE DRYWALL BULKHEAD EXTENDING FROM 9'0 AFF TO DECK. TRANSITION TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILI NG LI NE. VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL. OPROVIDE DRYWALL CEILING AT THIS LOCATION WITH 8" OF R04 VERTICAL DRYWALL FACE AT EXPOSED SI DE OF CURVE, BOTTOM OF BULKHEAD TO BE AT 9'-0" AFF. PAINT HORIZONTAL AND VERTICAL FACES (PTI; FLAT FINISH). RELOCATE PENDANT FROM TENANT'S EXISTING SPACE, R05 COORDINATE ALL REQUIREMENTS WITH TENANT. :9!!!n NG TO THIS LOCATION FORTENANT PROVIDEDHTING AND DIMMER S WITCH WHERE SHOW N ONM LOCATION AND SPECIFICATION OF LIGHT TENANT. OPROVIDE SOUND BOOTS IN THIS ROOM. DESIGN INTENT IS FOR R08 ROOM TO BE PRIVATE WITH AS LITTLE TRANSMISSION OF SOUND AS POSSIBLE. PROVIDE WIRING AND DIMMER SWITCH FOR FUTURE PENDANT AT R09 THIS LOCATION; ONLY CAN LIGHTING TO BE PROVIDED IN THIS ROOM. LINEAR LIGHTING AT THIS LOCATION TO BE PART OF ALTERNATE R70 PRICE FOR CEILING CLOUD. BASE BID TO INCLUDE (2) ADDITIONAL PENDANTS )TYPE "A°) ATTHIS LOCATION, REFLECTED CEILING PLAN 0 2' 4' 8' 16' � Ra e E N O N �o U S V C �nZ� - L b—M'u P Q I�: ~O w O M N V �C ea 'vwJ C THIS DRAWING, AND FIFE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPEFFY OF SCH07 DESIGN, INC., AND ARE NOTTO BE USED OR REPRODUCED IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. N co W v W-oz J Q W WS Z�N< 1 Z�QV) � Z Luz < ♦N z n HJC� W 0 LU O z LUO U� SSUE DATE DESCRIPTION 06.28.19 REVIEW SET 07.01.19 PERMIT SET 07.09.19 UPDATED SET REVISIONS MARI DB DESCRIPTION 07.19.19 EN UPDATED PE0.MIT: 07.31.19 CRB REV2 W.06.19 I EH I REV PROJECT NUMBER 2019.096 PROJ. MGR DRAWN BY EH AMM 1ST FLOOR REFLECTED CEILING PLAN >N Al21