HomeMy WebLinkAboutA121 1st Floor Reflected Ceiling PlanCONTACT JENEY HALL AT ESE
LEGEND OR LIGHTING: 3179512300 SPECTRUM
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT 177
COLUMBIALCAT 4, LED � LIGP RHAB LIC SURE, 2'X4',
nLIGHT FIXTURE, 2'x2', LED LIGHT FIXTURE, 2'x2'
COLUMBIA LCAT 0 FLUORESCENT, PARABOLIC
RECESSED LED LIGHT
FIXTURE, INTENSE SS6
A® LIGHT FIXTURE, LED
PENDANT, OCL CENTRO,
COLOR: WHITETEXTURED
POWDER COAT
® LIGHT FIXTURE,
B ZUMBOTEL 2.5"LINEAR LED,
DIRECT/INDIRECT. 6LENGT
C
NOT USED
LIGHT FIXTURE, LED
D®
PENDANT;TECH LIGHTING
BALTO 36" ABSTRACT
CHANDELIER.
70OBBLTGM-LED930-277:
GUNMETAL
LIGHT FIXTURE, LED
E®
PENDANT; WAG LIGHTING
PD-45747-BK E-MC2 47'W
LINEAR CHANDELIER;
BRUSHED ALUMINUM
LIGHT FIXTURE, LED
F®
PENDANT; VONN
VMC31740BLTIANA DUO
RING CHANDELIER LIGHT,
24"W, SILVER
— --
NOTUSED
0
®
EXITLIGHTFIXTURE
®
EXITLIGHTFIXTURE
EMERGENCY LIGHT FIXTURE
EMERGENCY LIGHT FIXTURE
$N
LIGHT SWITCH
$
LIGHT SWITCH
*N3
LIGHT SWITCH, 3-WAY
$3
LIGHT SWITCH, 3-WAY
$ND
LIGHT SWITCH, DIMMER
$,
LIGHT SWITCH, DIMMER
*NG
SWITCH, GARBAGE
$G
SWITCH, GARBAGE
DISPOSAL (ABOVE
DISPOSAL
COUNTERTOP)
i —
LIGHTCIRCUIT
" .
LIGHT CIRCUIT
CEILING GRID,
SUSPENDED, 2'x2'
17 GYPSUM BOARD CEILING
EXPOSED TO DECK
RELOCATED DIFFUSER,
LAY -IN, 2'x2'
RELOCATED DIFFUSER,
LAY -IN, 4"M
CEILING GRID,
---- SUSPENDED, 2'x2'
GYPSUM BOARD CEILING
®DIFFUSER,
LAY IN, 2'x2'
m DIFFUSER,
LAY -IN, 4"X4'
NOTE: IF IN GOOD CONDITION, EXSTING H.V.A.C. DEVICES AND CEILING TILE
SALVAGED FROM DEMOLITION CAN BE SUBSTTUTED FOR NEW. NO NEW
HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 08/19/19
RELOCATE DIFFUSERS &
MECHANICAL DIFFUSER RELOCATION
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
(2) ENLARGED REFLECTED CEILING PLAN = NOT USED
A121 CLOUD + LIGHTING TO BE ALTERNATE PRICE 0 1- 4
mmmml
GENERAL NOTES
I. PROVIDE NEW 2X2 BUILDING STANDARD CEILING GRID AT 9'-0"AFF-
TILES TO BE NEW 2x2 ACOUSTICAL LAY IN TILES.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SURE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE,
3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS,
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASTRAL 90.1,
CONTRACTOR MUST NOTIFY SDI,
4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH
ONE BUTTON OVERRIDE, OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHI N ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED,
5. NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW
AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO
ACCOMMODATE MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN
ADJACENT ON PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
MECHANICAL NOTES
I. MECHANICAL WORK IS LIMITED TO A DESIGNBUILDSCOPE ANDS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES,
® AREA NOT IN CONTRACT
❑ AREA OF WORK
PLAN NOTES
R01 CONTROL OPEN AREA, LIBRARY +COPY 120, AND PARALEGAL
STATION AREAS LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION
UNLESS NOTED OTHERWISE. PROVIDE MULTIPLE SWITCHES AS
REQUIRED.
R02 IN AREA TO BE EXPOSED TO DECK, REMOVE AS MUCH OF THE
EXPOSED CONDUIT, PIPING, JUNCTION BOXES AND
PROVIDE
RETAUNUSEDEQUIPMENT IN THE CEILING AS POSSIBLE.
PROVIDE RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED, CLEAN
AS REQUIRED AND LEAVE CONCRETE EXPOSED (NO PAINT).
OTRANSITION FROM CEILI NG GRID TO EXPOSED CEILI NG TO BE A 5"
R03 WIDE DRYWALL BULKHEAD EXTENDING FROM 9'0 AFF TO DECK.
TRANSITION TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH
THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY
CUT AT WALL TO CEILI NG LI NE. VERTICAL FACE OF DRYWALL TO BE
PAINTED COLOR OF ADJACENT WALL.
OPROVIDE DRYWALL CEILING AT THIS LOCATION WITH 8" OF
R04 VERTICAL DRYWALL FACE AT EXPOSED SI DE OF CURVE, BOTTOM
OF BULKHEAD TO BE AT 9'-0" AFF. PAINT HORIZONTAL AND
VERTICAL FACES (PTI; FLAT FINISH).
RELOCATE PENDANT FROM TENANT'S EXISTING SPACE,
R05 COORDINATE ALL REQUIREMENTS WITH TENANT.
:9!!!n
NG TO THIS LOCATION FORTENANT PROVIDEDHTING AND DIMMER S WITCH WHERE SHOW N ONM LOCATION AND SPECIFICATION OF LIGHT TENANT.
OPROVIDE SOUND BOOTS IN THIS ROOM. DESIGN INTENT IS FOR
R08 ROOM TO BE PRIVATE WITH AS LITTLE TRANSMISSION OF SOUND AS
POSSIBLE.
PROVIDE WIRING AND DIMMER SWITCH FOR FUTURE PENDANT AT
R09 THIS LOCATION; ONLY CAN LIGHTING TO BE PROVIDED IN THIS
ROOM.
LINEAR LIGHTING AT THIS LOCATION TO BE PART OF ALTERNATE
R70 PRICE FOR CEILING CLOUD. BASE BID TO INCLUDE (2) ADDITIONAL
PENDANTS )TYPE "A°) ATTHIS LOCATION,
REFLECTED CEILING PLAN
0 2' 4' 8' 16'
� Ra
e E
N O
N �o
U
S V C �nZ� -
L
b—M'u
P Q I�: ~O
w O M N
V �C
ea
'vwJ C
THIS DRAWING, AND FIFE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPEFFY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
N
co
W v
W-oz
J
Q W WS
Z�N<
1
Z�QV)
� Z
Luz <
♦N z n
HJC�
W
0 LU
O z
LUO
U�
SSUE
DATE
DESCRIPTION
06.28.19
REVIEW SET
07.01.19
PERMIT SET
07.09.19
UPDATED SET
REVISIONS
MARI
DB
DESCRIPTION
07.19.19
EN
UPDATED PE0.MIT:
07.31.19
CRB
REV2
W.06.19
I EH
I REV
PROJECT NUMBER
2019.096
PROJ. MGR DRAWN BY
EH AMM
1ST FLOOR
REFLECTED
CEILING PLAN
>N Al21