HomeMy WebLinkAboutE111 1st Floor Electrical PlanLEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JQ
JUNCTION BOX
QJ
OCEILING
MOUNTED
J
JUNCTION BOX
®
BOX, BLANK COVER PLATE
BOX, OPEN
QO
P
PROVIDE JUNCTION BOX
P
D
ABOVE CEILING FOR
O
POWER POLE
CONNECTION, POWER
POLE BY OTHERS.
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
POWER AND DATA POLE
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
F6I®
AND DATA, FLUSH
6b
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
®
JUNCTION BOX AND
J b
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
b
OUTLET (PROVIDE BOX
KI
AND PULL STRING ONLY)
OUTLET
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42"
HEIGHT OF ELECTRICAL
OR DATA DEVICE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�SJ'�D*S41WML_
DATE: \ 08/19/19
GENERAL NOTES
I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED I6" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL
NEW DEVICES AND FACE PLATES TO BE WHITE, REPLACE WITH NEW
AS REQUIRED.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI,
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
AREA NOT IN CONTRACT
AREA OF WORK
PLAN NOTES
OE01 PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER
)CARD READER BY TENANT). COORDINATE WITH TENANT'S
SECURITY CONTRACTOR, SEE DOOR SCHEDULE FOR MORE
DETAILS,
E02 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
E03 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
24' A.F.F.
E04 PROVIDE POWER AT THIS LOCATION FOR TENANT'S DISHWASHER
AND GARBAGE DISPOSAL.
E05 COORDINATE POWER REQUIREMENTS FOR SERVER ROOM WITH
TENANT.
E06 NOT USED,
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
E07 FOR ELECTRICAL AND DATA. COORDINATE WITH
TENANTAENANTS FURNITURE VENDOR ON EXACT LOCATION.
PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR
APPROVAL PRIOR TO ORDERING.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
E08
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
60" A.F.F.
ELECTRICAL PLAN
0 2' 4' 8' 16'
%"MmIIIIIIIEl
X WN
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
I NTEUECTUAL PROPERTY OF SCH OTT
DESIGN, INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
N
CO
Q
W v
W-oz
W
Q W WC
RRRJ ~
Z�N�
E
Z °� a
C L 7
WZQ
wwyzo
HJC�
LU
LEEOO 0
z
�O L
U
SSUE
DATE DESCRIPTION
06.28.19
REVIEW SET
07.01.19
PERMITSET
07.09.19
UPDATED SET
REVISIONS
MAR
DATE
DB
DESCRIPTION
07.19.19
EH
UPDATEDPERMIT:
07.31.19
CRB
REV2
08.06.19
EH
REVS
mim
PROJECT NUMBER
2019.096
ROJ. MGR DRAWN BY
EH AMM
1ST FLOOR
ELECTRICAL PLAN
E111