HomeMy WebLinkAboutE100.0NE / LR R
R R
WP
FURNISH & INSTALL (4) NEW 6" LED
EXTERIOR-RATED RECESSED CAN LIGHTS.
NEW CAN LIGHTS TO BE WIRED TO NEW
SINGLE-POLE DIMMER SWITCH
FURNISH & INSTALL (1) NEW EXTERIOR-
RATED CEILING FAN. NEW CEILING FAN TO
BE WIRED TO NEW SINGLE-POLE SWITCH
EXISTING GFCI RECEPTACLE IN
WEATHERPROOF HOUSING. REMOVE
EXISTING FLUSH-MOUNTED DEVICE &
REPLACE WITH SURFACE-MOUNTED BOX.
FURNISH & INSTALL NEW 3/4" CONDUIT
FROM NEW SURFACE-MOUNTED BOX
ALONG FACE OF EXISTING BRICK WALL,
DOWN TO BELOW GRADE, AND UP TO NEW
SWITCH LOCATION ON NEW POST AS
SHOWN
FURNISH & INSTALL (1) NEW SURFACE-
MOUNTED DOUBLE GANG BOX FOR (2)
NEW SINGLE POLE SWITCH. FURNISH &
INSTALL 3/4" CONDUIT FROM TOP OF NEW
BOX TO ABOVE CEILING FOR NEW FAN &
LIGHTS. PAINT NEW BOX & CONDUIT TO
MATCH POST (BY HOMEOWNER).
PERMIT
#1
ISSUE DATE:
2019-07-31
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared
by Case Design & Remodeling solely
for its use and should not be
reproduced or relied upon by any
other parties. Dimensions shown or
scaled are subject to change per
actual job condition and must be
verified. Materials are to be supplied
as specified as equal or standard
when not uniquely specified. Installed
materials may vary in appearance
from drawings. Reference
manufacturer's product data for actual
appearance and specifications.
CRAIG RESIDENCENEW PATIO COVERNAMES NATALIE CRAIG4231 LISTON DRIVECARMEL, INDIANA 46074Approved By:
Date:
E101
Craig Dice
Designer
cdice@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
242160116
JOB NUMBER:
FIRST FLOOR ELECTRICAL PLAN
SCALE: 1/4" = 1'
#2 2019-08-05
08/14/19
Mike Sheeks