Loading...
HomeMy WebLinkAboutA006 - PROPOSED ELECTRICAL PLANSWP WP WP EXISTING ELECTRICAL NOTES:ELECTRICAL NOTES: EXISTING COACH LIGHT & RECEPTACLE ADJACENT TO DOOR TO REMAIN. FURNISH & INSTALL (1) GFCI RECEPTACLE W/ WEATHERPROOF COVER IN CENTER OF PORCH CEILING ON SINGLE-POLE SWITCH AS SHOWN ON PLANS. F/I (2) GFCI RECEPTACLES W/ WEATHERPROOF COVERS AT OUTER CORNERS OF PORCH CEILING ON SINGLE- POLE SWITCH AS SHOWN ON PLANS. PORCH KITCHEN WP ELECTRICAL ELECTRICAL NOTES: INSTALL (1) H.O. PROVIDED COACH LIGHT ON NEW SINGLE-POLE SWITCH ADJACENT TO DOOR AS SHOWN ON PLANS. FURNISH & INSTALL (1) EXTERIOR GFCI RECEPTACLE W/ WEATHERPROOF COVER ADJACENT TO DOOR AS SHOWN ON PLANS. DECK BEDROOM #0 of 11 Date: 07.17.19 Sheet: Revision: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.Mewhinney ResidenceDeck AdditionBrian Mewhinney13680 Fossil Dr.Carmel, Indiana 46074Approved By: Date: 6 FINAL PROPOSED ELECTRICAL PLANS SCALE: AS NOTED Jordan Stocklin Designer jstocklin@caseindy.com Dave Null Lead Designer dnull@caseindy.com FIRST FLOORAA SCALE: 3/8" = 1' SECOND FLOORBB SCALE: 3/8" = 1' 07/23/19 Mike Sheeks