GENERAL NOTES
DIMENSIONS ARE BASED ON THE FOLLOWING CRITERIA:
A. GRID DIMENSIONS ARE TO CENTERLINE OF STRUCTURAL GRID LINE UNLESS
OTHERWISE NOTED.
B. ITEMS THATARE LOCATED ON A GRID LINE OR OTHERWISE LOCATED BY
MODULE, MULLION LAYOUT, SCHEDULE OR DETAILARE NOT OTHERWISE
DIMENSIONED.
C. DIMENSIONS ARE TO EDGE OF CONCRETE, FACE OF CONCRETE, OR FACE OF
CONCRETE MASONRY UNIT UNLESS OTHERWISE NOTED.
D. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE NOT SHOWN AND CANNOT BE
DETERMINED BY LAYOUT CRITERIA, CONTACT THE ARCHITECT FOR
CLARIFICATION.
E. WINDOWS ARE DIMENSIONED TO THE CENTERLINE OF OPENING UNLESS
OTHERWISE NOTED.
F. DIMENSIONING LAYOUT BEGINS WHERE THE START POINT IS INDICATED ON THE
DRAWINGS
G. WHERE A DIMENSION IS NOTED AS "CLEAR" THIS DIMENSION SHALL INDICATE
CLEARANCES AT COMPLETED CONDITIONS, TAKING FINISH MATERIALS INTO
ACCOUNT.
H. DIMENSIONS ARE BASED UPON SPECIFIED MATERIALS AND EQUIPMENT.
SUBSTITUTIONS MAYAFFECT DIMENSIONS. SUBSTITUTION REQUESTS SHALL
INDICATE THE IMPACT OF THE SUBSTITUTIONS UPON DIMENSIONS AND
CLEARANCES.
ELEVATIONS REFER TO THE BUILDING DATUM AS INDICATED. FLOOR ELEVATIONS
NOTED ARE TO TOP OF CONCRETE SLAB, OR INDIVIDUAL TOP OF WOOD SUBFLOOR,
UNLESS OTHERWISE NOTED.
A SITE SURVEY (IF PROVIDED) SHOWING SITE BOUNDARIES, BOUNDARY LENGTHS,
DECLINATIONS, SITE CONDITIONS AND GRADES AT THE TIME OF SURVEY WAS
FURNISHED TO THE DESIGN TEAM BY THE OWNER. CONTRACTOR SHALL VERIFY SITE
CONDITIONS PRIOR TO STARTING ANY WORK.
GEOTECHNICAL INFORMATION (IF PROVIDED) REGARDING GEOTECHNICAL AND SOIL
CONDITIONS AT THE SITE AT THE TIME OF THE REPORT WAS FURNISHED TO THE
DESIGN TEAM BY THE OWNER. CONTRACTOR SHALL VERIFY SITE CONDITIONS PRIOR
TO STARTING ANY WORK.
FIRE SPRINKLER WORK SHALL BE DESIGN -BUILD. PERMIT DRAWINGS FOR THIS WORK
SHALL BE A DEFERRED SUBMITTAL MADE BY THE CONTRACTOR. THE BUILDING OWNER
SHALL ENTER INTO SERVICE CONTRACTS WITH QUALIFIED AND LICENSED FIRE
SPRINKLER AND FIRE ALARM CONTRACTORS TO PROVIDE THE MAINTENANCE AND
TESTING OF BOTH THE FIRE SPRINKLER SYSTEM AND THE FIRE ALARM SYSTEM.
DOCUMENTATION VERIFYING THE SERVICE CONTRACTS SHALL BE SUBMITTED TO THE
FIRE INSPECTOR PRIOR TO BUILDING OCCUPANCY.
PROVIDE BACKING AND BLOCKING FOR WALL MOUNTED ELEMENTS AS REQUIRED FOR
ATTACHMENT AND FOR SEISMIC BRACING OF NON-STRUCTURAL ELEMENTS.
IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS ARE
ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ARCHITECTAND OWNER.
HAZARDOUS MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE
CONTRACT.
THE CONTRACTOR SHALL CAREFULLY REVIEW ALL OF THE CONTRACT DOCUMENTS
AND SHALL IMMEDIATELY CONTACT THE ARCHITECT REGARDING ANY APPARENT
ERRORS, INCONSISTENCIES, OR OMISSIONS DISCOVERED.
THE CONTRACT DOCUMENTS ARE CONSIDERED A WHOLE AND AS SUCH, THE
CONTRACTOR AND SUB -CONTRACTORS MUST COORDINATE ALL INTERRELATED WORK.
WHERE NEW CONSTRUCTION ABUTS EXISTING CONSTRUCTION TO REMAIN, OR WORK
DONE UNDER SEPARATE CONTRACT, ALL CONDITIONS AFFECTING WORK PROGRESS
AND CONFORMANCE TO PLANS AND SPECIFICATIONS SHALL BE VERIFIED BY
CONTRACTOR PRIOR TO START OF ANY WORK,
ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT RULES AND
REGULATIONS OF FEDERAL, STATE, AND LOCAL CODES, LAWS, ORDINANCES, STATUES,
AND REGULATIONS. NOTHING IN THE CONTRACT DOCUMENTS SHALL BE CONSTRUED
REQUIRING OR AUTHORIZING WORK CONTRARY TO THESE RULES, REGULATIONS, AND
CODES.
THE DRAWINGS INDICATE LOCATIONS, DIMENSIONS AND TYPICAL DETAILS OF
CONSTRUCTION. THE DRAWINGS DO NOT ILLUSTRATE EVERY CONDITION; WORK NOT
EXPRESSLY DETAILED SHALL BE OF CONSTRUCTION SIMILAR TO PARTS THAT ARE
DETAILED. WHERE APPARENT DISCREPANCIES OCCUR, THEY SHALL BE REPORTED TO
THE ARCHITECT FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK.
GRAPHICS AND SIGNAGE ITEMS SHALL BE FURNISHED AND INSTALLED BY
CONTRACTOR. CONTRACTOR SHALL PROVIDE BACKING AS REQUIRED FOR PROPER
INSTALLATION.
THE CONTRACTOR SHALL EXAMINE WORK IN PLACE ON WHICH ADDITIONAL SPECIFIED
CONSTRUCTION IS TO BE APPLIED TO ENSURE THAT SUBSTRATE CONDITIONS ARE
SATISFACTORY FOR THE INSTALLATION OF SPECIFIED FINISH MATERIALS. VERIFY THAT
SUBSTRATES, APPURTENANCES, AND OTHER ACCESSORIES ARE IN PLACE AS
REQUIRED BY FINISH MATERIALS. REPORT IN WRITING ANY DEFECTS, OR CONDITIONS
WHICH MAY DELAY COMPLETION OF PERFORMANCE OF SPECIFIED FINISH WORK.
FAILURE OF SUCH NOTIFICATION WILL BE CONSTRUED AS ACCEPTANCE OF
SUBSTRATES AND WORK IN PLACE. CORRECTIVE WORK REQUIRED BY ARCHITECT OR
OWNER DUE TO CONTRACTOR'S ACCEPTANCE OF UNSATISFACTORY SUBSTRATE AND
WORK IN PLACE CONDITIONS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER.
SEPARATE CONTRACTS: THE CONTRACTOR SHALL COORDINATE AND COOPERATE
WITH THE WORK OF SEPARATE CONTRACTS SUCH AS TENANT IMPROVEMENTS, MAJOR
TENANT BUILDINGS, AND PUBLIC UTILITIES, ETC.
FLOORING AND FINISH PROTECTION: THE CONTRACTOR SHALL PROTECT NEW
FLOORING AND FINISHES INSTALLED UNDER THIS CONTRACT AND SHALL REPAIR AND
REPLACE OR REPAIR ANY DAMAGED FLOORING OR FINISHES AT NO ADDITIONAL
COST TO THE OWNER UNTIL OWNER'S FINAL ACCEPTANCE OF FLOORING AND
FINISHESAT CONCLUSION OF TENANT WORK.
FIRESTOPPING AND FIRE RATED PENETRATIONS REQUIRED AT ALL FIRE RATED WALLS
SHALL COMPLY WITH ALL APPLICABLE CODES. CONTRACTOR SHALL SUBMIT
MANUFACTURER'S LITERATURE INCLUDING DATA FOR MATERIALS AND PREFABRICATED
DEVICES, UNDERWRITER'S LABORATORY APPROVAL NUMBERS FOR REQUIRED FIRE
RATINGS, SHOP DRAWINGS FOR MANUFACTURER'S INSTALLATION DETAILS AND
CERTIFICATES OF COMPLIANCE SHOWING MATERIAL OR COMBINATION OF MATERIALS
USED MEETS REQUIREMENTS SPECIFIED FOR FLAME SPREAD AND FIRE RESISTANCE.
CONTRACTOR SHALL SUBMIT TO THE FIRE DEPARTMENT ELECTRONIC COPIES ON A CD
OF THE DRAWINGS OF RECORD FOR THE BUILDING. THESE SHALL INCLUDE SITE PLAN,
FIRE UNDERGROUND UTILITY PLANS, BUILDING PLANS, FIRE SPRINKLER PLAN AND FIRE
ALARM PLAN AS APPLICABLE.
ANY WOOD, WOOD BLOCKING, OR WOOD SHEATHING USED TO BE FIRE -RETARDANT -
TREATED WOOD.
USE MOISTURE/MOLD RESISTANT GYPSUM BOARD ON ALL WET WALLS AND AT ALL
LOCATIONS EXPOSED TO WATER.
FGRFSS DOOR HARDWARES At I FGRFSS DOORS SHALL BE OPERABLE FROM THE SIDE
RELEASED FOR CONSTRUCTION A KEY OR SPECIAL SHALLINSPECT & VERIFY ALL
ALL EXISTING
PD TO, LOCATIONS OF WALLS, STRUCTURAL
Subject to compliance with all regulationsSTEMS, PLUMBING B ELECTRICAL SYSTEMS,
of State and local Codes -CTIONS AND METERING DEVICES PRIOR TO
e City of Camel BEG INNING ANY WORK.
�vm�tlonrkvaAaL
DATE: \ 08/23/19
SPENGA
spin • strength • yoga
14511 Clay Terrace Blvd.
Space B16
Carmel, Indiana 46032
CTel xN 11111111 1111111] CLTJ_\ I [ELT
CITY OF CARMEL (STATE OF INDIANA) - CODES:
BUILDING CODE:
2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE)
FIRE CODE:
2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE)
ELECTRICAL CODE:
2009 INDIANA ELECTRICAL CODE (NFPA 70. 2008 EDITION)
PLUMBING CODE:
2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE)
MECHANICAL CODE:
2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE)
FUEL GAS CODE:
2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE)
ENERGY CODE:
201 D INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1 2007 EDITION)
ACCESSIBILITY:
2014 INDIANA BUILDING CODE CHAPTER 11 ACCESSIBILITY (6751AC 13-2.6-12 CHAPTER 11)
2009 A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES
General Project Description:
TENANT BUILD -OUT OF ANEW FITNESS INSTRUCTION CENTER WITHIN AN EXISTING SINGLE -STORY SHOPPING
CENTER.
THE TENANT OFFERS INSTRUCTOR -LEAD EXCERCISE CLASSES CONSISTING OF 24 PARTICIPANTSICLIENTS
WITH 1 INSTRUCTOR.
CONSTRUCTION TYPE:
II -A
OCCUPANCY CLASSIFICATION:
GROUPA3
FULLY SPRINKLED BUILDING:
YES
LEASE SPACE AREA:
+/-5,004 BE GROSS
OCCUPANCY LOAD:
4.357 SF GROSS TOTAL
4.357 SF @ 50 SF PER PERSON = 88 OCCUPANTS
88 TOTAL OCCUPANTS
EXITS REQUIRED:
2
EXITS PROVIDED: 2
EXIT ACCESS TRAVEL DISTANCE:
MAXIMUM -200'
1 OVERALL BUILDING PLAN
NTS
AREA OF WORK
TENANT SPACE B16 PROJECT
5003 SF NORTH
FULLY
PROJECT TEAM
Construction Monsoons :
Foxfield Construction Ltd.
1245 Humbracht Circle, Suite D
Badlett, IL 60103
Contact: Thomas Piano II
Phone: 630-213-0777 x306
tpiazza@foxfieldkd.com
ArchitectlMEP Engineer:
Virtual Energy Solutions, Inc
6252 W. 59th Street
Chicago, IL 60638
Contact: George lain Dickie
Phone: 630J70-3265
idickie@veschicago.mm
FIRE PROTECTION SYSTEMISI:
DRAWINGS BY CERTIFIED FIRE
SUPPRESSION AND/OR FIRE
ALARM CONTRACTOR(S) SHALL BE
SUBMITTED FOR REVIEW UNDER
SEPARATE COVER
SPECIAL NOTE: DO NOT SEPERATE
THIS SET OF DRAWINGS
THE CONTRACTOR SHALL BE
RESPONSIBLE FOR DISTRIBUTING
COMPLETE SETS OF THESE PLANS
AND PROJECT SPECIFICATIONS TO
ALL SUB -CONTRACTORS INVOLVED
WITH THIS PROJECT. A COMPLETE
SET OF THESE PLANS SHALL BE IN
THE POSSESSION OF THE
CONTRACTOR AND ALL SUB-
CONTRACTORS ON THE PROJECT
AT ALL TIMES. THE SHEET INDEX
ABOVE LISTS THE CONTENTS OF
THIS SET OF DRAWINGS. IF IT IS
SUSPECTED THAT THERE ARE ANY
MISSING SHEETS, PLEASE
CONTACT THE ARCHITECT.
OCCUPANCY
WATER CLOSETS
LAVATORIES
DRINKING FOUNTAIN
LOAD
REQUIRED
REQUIRED
REQUIRED
88 TOTAL
(44 MALE)
MALE =I PER 125=1
MALE =I PER 200=1
1PER 500
(44 FEMALE)
FEMALE - I PER 65-1
FEMALE - I PER 200-1
Sheetlndex
Sheet Number
Sheet Name
A001
COVER SHEET
A002
ACCESSIBILITY, SYMBOLS S ABBREVIATIONS
A100
DEMOLITION PLAN
A101
FLOOR PLAN
A101FN
FIRST FLOOR FINISHES PLAN
A101FS
FINISH SCHEDULES & EQUIPMENT NOTES
A102
REFLECTED CEILING PLAN
A200
ROOF PLAN
A501
PARTITIONS & DETAILS
A502
INTERIOR ELEVATIONS & DETAILS
A503
INTERIOR ELEVATIONS, ENLARGED PLAN S SECTION
A504
MENS ROOM ENLARGED PLAN & ELEVATIONS
A505
WOMENS ROOM ENLARGED PLANS & ELEVATIONS
A601
DOOR SCHEDULE & RESTROOM DETAILS
E001
ELECTRICAL SYMBOLS AND ABBREVIATIONS
E002
ELECTRICAL SPECIFICATIONS
E501
ELECTRICAL SCHEDULES AND DETAILS
E601
ELECTRICAL SCHEDULES AND RISER DIAGRAMS
EL101
ELECTRICAL FIRST FLOOR LIGHTING PLAN
EP101
ELECTRICAL FIRST FLOOR POWER PLAN
FP001
FIRE PROTECTION SYMBOLS AND ABBREVIATIONS
FP101
FIRE PROTECTION FIRST FLOOR PLAN
FP501
FIRE PROTECTION DETAILS
Moot
MECHANICAL SYMBOLS AND ABBREVIATIONS
M002
MECHANICAL SPECIFICATIONS
M003
MECHANICAL SPECIFICATIONS
M004
MECHANICAL SPECIFICATIONS
M501
MECHANICAL DETAILS
M601
MECHANICAL SCHEDULES
MV101
MECHANICAL FIRST FLOOR VENTILATION PLAN
MW 02
MECHANICAL ROOF VENTILATION PLAN
Pool
PLUMBING SYMBOLS AND ABBREVIATIONS
P002
PLUMBING SPECIFICATIONS
P003
PLUMBING SPECIFICATIONS
P004
PLUMBING SPECIFICATIONS
P005
PLUMBING SPECIFICATIONS
P006
PLUMBING SPECIFICATIONS
P501
PLUMBING DETAILS
P601
PLUMBING DIAGRAMS AND SCHEDULES
PP101
PLUMBING FIRST FLOOR PIPING PLAN
PW101
PLUMBING FIRST FLOOR VENT& WASTE PLAN
SERVICE SINK
REQUIRED
1
WATERCLOSETS
LAVATORIES DRINKING FOUNTAIN SERVICE SINK
PROVIDED
PROVIDED PROVIDED PROVIDED
MALE-2
MALE-2 1 1
FEMALE =2
FEMALE =2
PROJECT MAP
NORTH
n PROJECT SITE
NTS
I HEREBY CERTIFY THAT THESE DRAWINGS WERE
PREPARED BY ME OR UNDER MY DIRECT
SUPERVISION AND TO THE BEST OF MY
PROFESSIONAL KNOWLEDGE COMPLY WITH THE
PROVISIONS OF THE STATE OF INDIANA BUILDING
CODES.
Ir
GEORGE I. DICKIE
INDIANA LICENSED LCHITECT 11900058
EXPIRES: 12J31/2019
G
SP-NGA
spin • strength • yoga
FOXHIELD CONSTRUCTION LTD.
�p�,l iC�� ]i uew��s�nuaaa
VIRTUAL
ENERGY
SOLUTIONS
33 E. OGDEN AVE. SUITE 304
LA GRANGE IL, 60525
312.583.7023
W W W.VESCHICAGO.COM
#AA26003751
_
N
c�
Mi
W
C)
Q)
Q
U
�
`
L
M�
L
Z
(Q
W
(Q
Q
U
U
r�
�
V J
r
l0
L
M
r
U
No. AR11900058
STATE OF
VIES project number: 190301
sheet title:
COVER SHEET
sheet number:
A001
0 2018 Victual Energy Solutions, Inc.