HomeMy WebLinkAboutA504 - MENS ROOM ENLARGED PLAN & ELEVATIONST#91 Z Z 7 7,.cTda *F911141111. 101 d 5 8'- 1" 2 C < C ADA m COMPLIANT WC ® 30"x48" 2 60"x60" 2 2 CLEAR CLEAR _ _ _ _ _ 4 A505 6 SPACE SPACE - --- -- --_ - TOILET Men's STALL en PARTITION i A504 3 301 `-------- CLEAR �____________________ SPACE 2 A� 0_________ -' ------ '° L m T I i I A504 4 i \ DOOR 101 APPROACH - CLEARANCE ) 2 --- --2f - �e 2 4'- 11 1/2" 1' - 8 1/2" n ENLARGED PLAN AT MENS ROOM 1/2" =1,_D„ CENTER OVER VANITY (PROVIDE IN -WALL BLOCKING). SEE SHEET 14 7 Alti FOR AD DI I INAL INFO. A504 22F P3E PIE TYP @ CEILING TOILET PARTITION NOTE: PROVIDE IN- _ F WALL BLOCKING FOR GRAB BARS, TIP HOLDER & TOILET CT3 PARTITION, TYP GRAB BARS (4)— GBi z O m TP1 oO CT7 U LL m 1-0, 1._0, GB2 — > U SEAT c W Q 0 w T 2 ofIN Q k. - 6" REMOVABLE KNEE FLUSH VALVE MUST BE 1/2" = 1'-0" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carnal DATE: 08/23/19 PROTECTION PANEL —' ` ON OPEN SIDE OF W.C. I ` P2F P3E P3E 16 �� P35 CTt CT7 CT1 N TOILET ACCESSORIES SCHEDULE TAG DESCRIPTION Length I Comments G61 B]BRCK B®mSTMGM GWb 84Rdi AF9RWEG 3'S WE BoUICK WNGIT GRIB MR EOuu ATTACHMENT SomEM GR A PRCMED EGUI G6R P1IR0.CK 658m 5TPI liM GRPH R40. dYAFP0.WE0 3'P WE PaRNfX WNOn Gi MR EWK ATTACHMENTSYSTEMW ASPRGVED Eouu. TP.i eoi 8­3IM COSGCSEMES RECESSED MULTI RALTaLETnssuEDISPENSER 22F ATCEIUNG 3E GB-1 G&2 1'-0" T-6" z m j CTi K n East Elevation -MEN n West Elevation - MENS ADA COMPLIANT WC 18 NOTE: PROVIDE POWER AND IN - WALL BLOCKING. NOTE: PROVIDE IN -WALL BLOCKING FOR GRAB BARS 8 TP HOLDER, TYP. 1. GENERAL: REQUIRED ACCESSIBLE FEATURES OF THE RESTROOMS SHALL COMPLY WITH THE LATEST EDITION OF THE ACCESSIBILITY CODE. 2. WATER CLOSETS: A. ALL WATER CLOSETS SHALL BE TANK TYPE AND INCLUDE SEATS (OPEN FRONT) AND CONTROLS FOR A COMPLETE OPERATING UNIT. FIXTURE TO BE FLOOR MOUNTED AND CAULKED TO FLOOR. B. W.C. CONTROLS TO BE ON OPEN SIDE OF FIXTURE. C. HEIGHTS OF ACCESSIBLE W.C. SHALL BE 17" TO 19" TO TOP OF SEAT. SEAT SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. 3. TOILET PAPER DISPENSERS: A. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT PREVENTS CONTINUOUS PAPER FLOW. B. DISPENSERS SHALL BE MOUNTED A MINIMUM OF 15" ABOVE THE FINISHED FLOOR SURFACE AND 7" TO 9" (TO CENTERLINE OF DISPENSER) FROM FRONT EDGE OF W.C. C. DISPENSERS SHALL BE A MINIMUM OF 1 1/2" BELOW GRAB BAR. 4. URINALS (IF INDICATED IN SCOPE): A. ALL URINALS SHALL INCLUDE FLUSH VALVES AND MOUNTING ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION. B. ACCESSIBLE URINALS SHALL BE MOUNTED A MAXIMUM OF 17" ABOVE THE FINISHED FLOOR. C. URINAL(S) SHALL BE CAULKED TO WALL. 5. LAVATORIES 8 MIRRORS: A. LAVATORIES SHALL INCLUDE FAUCET AND MOUNTING HARDWARE AS NECESSARY FOR A COMPLETE INSTALLATION. B. LAVATORIES SHALL BE MOUNTED WITH THE COUNTER NO HIGHER THEM 34" ABOVE THE FINISHED FLOOR. ALL LAVATORIES SHALL BE UNDERMOUNTED TO THE COUNTER. C. LAVATORY APRON SHALL BE A MINIMUM OF 27" ABOVE THE FINISHED FLOOR. D. HOT WATER LINE AND DRAIN PIPES UNDER LAVATORIES SHALL HAVE PROTECTION AGAINST CONTACT. THERE SHALL NOT BE ANY SHARP OR ABRASIVE SURFACES OR ITEMS UNDER THE LAVATORIES. E. HOT WATER DISPENSED BY THE LAVATORY FAUCETS SHALL NOT EXCEED 110 DEGREES. F. FAUCETS SHALL ALLOW WRIST CONTROL. G. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGES OF THE REFLECTIVE SURFACE NO HIGHER THAN 40" A.F.F. H. LAVATORY FAUCETS: METERED FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM. 6. SANITARY NAPKIN DISPOSAL (IF INDICATED IN SCOPE): A. A SANITARY NAPKIN DISPOSAL UNIT SHALL BE INSTALLED IN EACH WOMEN'S WATER CLOSET STALL W ITH TOP MOUNTED AT T-9" A.F.F. 7. TOILET ROOM SIGNAGE: A. ALL TOILET ROOMS SHALL BE APPROPRIATELY IDENTIFIED WITH SIGNAGE SYMBOL OF ACCESSIBILITYAND INCLUDE BRAILLE. B. SIGNAGE SHALL BE MOUNTED ADJACENT TO THE LATCH SIDE OF EACH DOOR, 60" VERTICALLY TO THE CENTERLINE OF THE SIGN A.F.F. AND 9" HORIZONTALLY FROM THE EDGE OF THE DOOR FRAME. 8. GRAB BARS: A. ALL GRAB BARS SHALL BE I I/4"-11/2"IN DIAMETER. B. THE SPACE BETWEEN THE FINISHED WALL AND GRAB BAR SHALL BE 1 1/2". C. HORIZONTAL GRAB BARS SHALL BE MOUNTED 33" TO 36" A.F.F. TO CENTERLINE OF THE GRAB BAR. D. BENDING STRESS IN A GRAB BAR INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 2501bs SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR. E. SHEAR STRESS INDUCED IN A GRAB BAR BY THE APPLICATION OF 250 be SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR. IF THE CONNECTION BETWEEN THE GRAB BAR AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RETRAINED, THEN DIRECTIONAL AND TORSIONAL SHEAR STRESSES SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS, WHICH SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. F. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF 250 Ill SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR THE MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE LOAD. G. TENSILE FORCE INDUCED IN A FASTENER BYA DIRECT TENSION FORCE OF 250 the PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250 Ibis SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND THE SUPPORTING STRUCTURE. H. ACCEPTABLE GARB BAR MOUNTING HARDWARE: a. BOBRICK'WINGITGRAB BAR FASTENING SYSTEM to MOEN'SECUREMOUNTGRAB BAR ANCHORING SYSTEM I. GRAB BARS SHALL NOT ROTATE IN THEIR FITTINGS. 9. ADDRIONAL REQUIREMENTS: A. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5lbs. B. ALL FIXTURES,ACCESSORIES, AND MATERIALS SHALL COMPLYWITH ALL APPLICABLE ACCESSIBILITY CODES. C. ALL PLUMBING FIXTURES IN THE RESTROOMS SHALL BE WHITE. D. G.C. SHALL COORDINATE THE LOCATIONS AND PLACEMENT OF ALL IN -WALL BLOCKING AND REINFORCED MOUNTING HARDWARE. P3E OPEN BEYOND 3 CT3 n East Elevation 2 - MENS P2F CERING z m o O z o z z CTi Do 12 P3E SOLID SURFACE VANITY COUNTER W/ 4" BACK & SIDE SPLASH, CONFIRM FINISH 8 COLOR PROVIDE IN -WALL BLOCKING AT REAR 11 AND SIDE WALL, G.C. TO COORDINATE P-LAM VANITY CABINET, r CONFIRM FINISH & COLOR T/ LEAVE BOTTOM OF CABINET OPEN z O z E z rc SP-NGA spin • strength • Vega FOXFIELD CONSIRUCIION LTD. D®BxasoELsoev¢s�anuuaas VIRTUAL ;ENERGY SOLUTIONS 33 E. OGDEN AVE. SUITE 304 LA GRANGE IL, 60525 312.583.7023 W W W.VESCHICAGO.COM #AA26003751 �0 N M M> W Q U L 00 1 Z w (6 Q U� C E � U r No. AR11900058 STATE OF VIES project number: 190301 sheet title: MENS ROOM REMOVABLE KNEE ENLARGED PLAN PROTECTION PANEL ACCESSIBLE CLEAR ELEVATIONS KNEE SPACE sheet number: n Section at ADA Sink -0" A504 02018 Virtual Energy Solutions, Inc.