HomeMy WebLinkAboutE001 - ELECTRICAL SYMBOLS AND ABBREVIATIONS5 GENERAL NOTES ABBREVIATIONS RECEPTACLES SWITCHES TECHNOLOGY SYMBOLS LUMINARIES 1. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS OF HVAC, PLUMBING AND FIRE PROTECTION EQUIPMENT. 2. CAREFULLY, VIEW THE ARCHITECTURAL, STRUCTURAL, MECHANICAL, HVAC FURTHER WORKING SCOPE SPECIFICATIONS FOR FURTHER WORK SCOPE AND FOR ADDITIONAL INFORMATION. 3. PROVIDE RACEWAY AND 120V POWER FOR SECURITY SYSTEM DEVICES. COORDINATE WORK WITH SECURITY CONTRACTOR, PRIOR TO INSTALLATION. 4. PROVIDE RACEWAY, 120V POWER AND GROUNDING FOR COMMUNICATIONS SYSTEMS INCLUDING TELEPHONE, DATA, CABLE TELEVISION, INTERCOM, AUDIOVISUAL, ETC. COORDINATE WORK WITH TELECOMMUNICATIONS CONTRACTOR, PRIOR TO INSTALLATION. 5. THE CONTRACTOR SHALL PROVIDE OVERSIZED PULL BOXES UTILIZED FOR TELECOMMUNICATIONS, SECURITY AND AN W IRING AT CEILING MOUNTED ACCESS PANEL LOCATIONS. ACCESS PANEL LOCATIONS SHALL BE COORDINATED WITH ARCHITECTAND GENERAL CONTRACTOR, PRIOR TO INSTALLATION. 6. FEEDER AND BRANCH CIRCUIT WIRING SHALL BE SIZED FOR A MAXIMUM 5 % VOLTAGE DROP TOTAL. UPSIZE FEEDER AND BRANCH CIRCUITWIRING AS REQUIRED FOR RUN LENGTH IN THE FIELD. 7. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN A COMPLETE AND SEPARATE RACEWAY SYSTEM AND THE RACEWAY SHALL BE RED IN COLOR. 8. THESE DRAWINGS ARE DIAGRAMMATICAL IN NATURE, AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT, BUT ACCURACY IS NOT GUARANTEED. FIELD VERIFICATION OF LOCATIONS AND DIMENSIONS MY BE REQUIRED. 9. THESE DRAWINGS WILL NOT SHOW ALL INSTALLATION DETAILS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE A COMPLETE AND SATISFACTORY INSTALLATION IN ACCORDANCE WITH NECA 1 AND MODERN PRACTICE METHODS. 10. EQUIPMENT DIMENSIONS SHOWN ON PLANS AND ELEVATIONS ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL USE THE SHOP DRAWINGS FOR PROPER LAYOUT, COINSTALLATION, WITHOUT ANY ADDITIONAL COSTST TO TO THE OWNER. 11. ELECTRICAL CONTRACTOR SHALL MAKE THEIR OWN COUNT OF ALL EQUIPMENTTO BE WIRED BASED ON PLANS AND SPECIFICATIONS. 12. PROVIDE AN INSULATED GROUND WIRE WITH ALL CIRCUITS. 13. ALL NEW CIRCUITS SHALL BE RUN WITH DEDICATED NEUTRALS. SHARED NEUTRALS ARE NOTALLOW ED. NOT ALLOWED. 14. LABEL EACH RECEPTACLE WITH THE PANEL NAME AND CIRCUIT NUMBER SERVING THEM. AC AFT AM BPS BEE CB CCT CO DISC DIN DPDT E EM EPO EWC FA FCU FEB FFC GFI GIRD HID HDA HE JB IG KV KW LTG MCB MLO MV NC NIC NO PNL PRI PT RCP SEC SECT SW T TP UH VP WE WIT XP I ABOVE COUNTER ABOVE FINISHED FLOOR AUTOMATIC TRANSFER SWITCH BOLTED PRESSURE SWITCH BLOWN FUSE PROTECTION CIRCUIT BREAKER CIRCUIT CONDUITONLY DISCONNECT DOWN DOUBLE POLE DOUBLE THROW EXISTING TO REMAIN EMERGENCY EMERGENCY POWER OFF ELECTRIC WATER COOLER FIRE ALARM FAN COIL UNIT FAN POWERED BOX FORCED FLOW CONVECTOR GROUND FAULT INTERRUPTER GROUND HIGH INTENSITY DISCHARGE HAND OFF AUTOMATIC HORSEPOWER JUNCTION BOX ISOLATED GROUND KILOVOLT KILOWATT LIGHTING MAIN CIRCUIT BREAKER MAIN LUGS ONLY MEDIUM VOLTAGE NORMALLY CLOSED (CONTACTS) NOT IN CONTRACT NORMALLY OPEN (CONTACTS) NOTTOSCALE PANEL PRIMARY POTENTIAL TRANSFORMER REFLECTED CEILING PLAN SECONDARY SINGLE POLE DOUBLE THROW SWITCH TELEPHONE TAMPER PROOF UNIT HEATER VAPOR PROOF WEATHERPROOF WATERTIGHT EXPLOSION PROOF ❑ �H�) T� WALL MOUNTED RECEPTACLES (W / STEM) MOUNTING HEIGHT I'S" FLOOR MOUNTED RECEPTACLES (W /SQUARE) CEILING MOUNTED CIRCLE) INSTALL LEVELWITH FINISHED CEILING. SUPPORT TO STRUCTURE. Ep 1a SINGLE POLE SWITCH. THE NUMBER DENOTES CIRCUIT NUMBER AND THE LETTER'a' SWITCH CONTROL XX WALL MOUNTED DEVICES (W/STEM) CEILING MOUNTED DEVICES (W / CIRCLE) DOOR FRAME MOUNTED DEVICES Ellix4 � FLUORESCENT/LED LIGHTING FIXTURE. =A3W THREE WAY SWITCH O 2x4 FLUORESCENT/LED LIGHTING FIXTURE. PROVIDE 4'x4'x2-1/2' BACKBOx WITH MUDRING AN D 1' CONDUIT TO ACCESSIBLE CEILING SPACE ABOVE. WHERE AUTHORITY HAVING JURISDICTION MANDATES PROVIDE CONDUIT CONTINUATION THROUGH PLENUM SPACES. �K KEY OPERATED SWITCH O FLOURESCENTILED DOW NLIGHT OR HIGH BAY. DUPLEX DOUBLE DUPLEX RACEWAYS AND WIREWAYS $j STANDARD RECEPTACLE fRP SWITCH WITH PILOT LIGHT 0 INTERCOM. PROVIDE MANUFACTURER BACKBOX COORDINATE INSTALLATION WITH COMMUNICATION DEVICE INSTALLER. ALL CABLING IN RACEWAY. QJ JUNCTION BOX CRITICAL RECEPTACLE b D DIMMER SWITCH WATTAGE AS NECESSARY 0 TELEVISION OUTLET V JUNCTION BOX- WALL MOUNTED GFI RECEPTACLE ((�^�)) 4 WIRELESS ACCESS POINT f»D3 3-WAY DIMMER SWITCH WATTAGE AS NECESSARY � ABOVE COUNTER RECEPTACLE �t V o JUNCTION BOX WITH FLEXIBLE CONNECTION OJ SECURITY CAMERA +ALV TO TIE CONTROL SWITCH TO BE CONNECTED TO BE CONNECTED TO TIE DELTA CONTROL PANEL. � ABOVE COUNTER OR RECEPTACLE ^ r �u JUNCTION BOX FOR FURNITURE POWER IN -FEEDS 05 SPEAKER. O� VOLUME CONTROL + USB RECEPTACLE � r lW JUNCTION BOX FOR TELE/DATA IN -FEEDS 0 TELERWISEDATA OUTLET I8"AFF, UNLESS NOTED TAMPER PROOF RECEPTACLE 3 a LCC$ K 5J3Wb 'a-i "D" '2' "3W" '4W' 'K" "O" P. "T' "PH" "TS" MWS' R/S' 'WSTAT" ' LV(2)' 'LM" 'MC' "LCC" SWITCH LEG CONTROL LETTER CODE(S) DIMMER 1,000W CONTROL SWITCH DOUBLE -POLE TOGGLE SWITCH THREEWAVSWITCH FOUR WAY SWITCH KEY OPERATED SWITCH OCCUPANCY SENSOR SWITCH TOGGLE SWITCH WITH PILOT LIGHT ROTARY SWITCH WITH TIMER CONTROL PHOTOCELL CONTROL jll E>+zj WEATHERPROOF, GFI RECEPTACLE W Q WALL MOUNTED TELEPHONE OUTLET 4TAFF, UNLESS NOTED OTHERWISE. SINGLE GANG JUNCTION BOX WITH I'C TO TECHNOLOGY CLOSET. SPECIAL RECEPTACLE -REFER TO PLANS FOR NEMA TYPE ® CARD READER. rti Ll� PROVIDE DUAL CHANNEL LEGRAND 25DTP SERIES POWER POLE FOR POWER AND LOW VOLTAGE CABLING. SUPPORT RACEWAY AT BOTH ENDS. p © KEY PAD ® A FLOOR BOX EXIT SIGN SCHEDULE ES ELECTRIC STRIKE SINGLE FACE DOUBLE FACE �� DUPLEX RECEPTACLE - POKE -THROUGH FITTING INCLUDING DRILLING ALL OTHER COMPONENTS. THERMALSWITCH WALL SW ITCH TEMP/SENSOR SWITCH WALL LINE VOLTAGE STAT CHICAGO CODE No. DESCRIPTION SYMBOL CHICAGO CODE No. DESCRIPTION SYMBOL MAGNETIC LOCK 1 FIRE ESCAPE ® 13 FLUSH OR RECESSED 2 STAIRS 14 TRIANGLE LOW VOLTAGE SWITCHING SYSTEM# QUANTITY OF LV SWITCHES MASTER SWITCH FOR LOW VOLTAGE SWITCHING SYSTEM MOMENTARY CONTACT SWITCH SWITCH LEG TO LTG CONTACTOR COIL"LCC" D� DOOR CONTACT 3 EXIT 15 ELEVATOR REX REQUEST FOR EXIT 4 FIRE ESCAPE � ® 16 FIRE ESCAPE— 9 5 STAIRS 17 STAIRS DOOR RELEASE. PROVIDE I/T CONDUIT TO DOOR RELEASE BUTTON(DRB). MOTORS AND CONTROLS DS INFRARED360° ESPASSIVE TSENSOR CAUGHT HARVESTING DAYLIGHT HARVESTING LIGHT SENSOF2 6 EXIT _ 18 EXIT M 1 MOTOR, REFER TO SCHEDULE FOR HORSEPOWER, DESCRIPTION, WIRING AND PANEL FED FROM ORB DOOR RELEASE BUTTON MOUNTED ABOVE COUNTER FOR A SINGLE DOOR RELEASE. PROVIDE 1/2" CONDUIT TO DOOR RELEASE. 7 FIRE ESCAPE ® 19 FIRE ESCAPE teI pC CEILING MOUNTED DUAL TECHNOLOGY BEY OCCUPANCY SENSOR DOOR RELEASE BUTTON MOUNTED ON WALL. FOR MAGNETIC DOOR RELEASE. CONNECT TO DOOR ACCESS SYSTEM. 8 STAIRS 20 STAIRS 5 MOTOR, NUMBER INDICATES HORSEPOWER 9 _ EXIT 21 EXIT OC WALL MOUNTED DUAL TECHNOLOGY 3600 OCCUPANCY SENSOR FIRE ALARM SYMBOLS Ql DISCONNECT SWITCH, RATING AS INDICATED 70 FIRE ESCAPE ® 22 FIRE ESCAPE /�� LJ OS WALL MOUNTED DEVICES (W/STEM) CEILING MOUNTED DEVICES(W/CIRCLE) ONE -LINE ELECTRICAL DIAGRAM SYMBOL 11 STAIRS STAIRSHITS FUSIBLE DISCONNECT, RATING AS INDICATED INCOMING LINE TRANSFORMER 12 EXIT q 177223 _ EXIT BATTERY PACK FIXTURES WITH NUMBER OF HEADS SHOWN ® MAGNETIC MOTOR STARTER FAAP FIRE ALARM ANNUNCIATOR PANEL GENERAL BRANCH CIRCUIT NOTES COMBINATION MOTOR STARTER FRCP F IRE ALARM CONTROL PANEL POTENTIAL TRANSFORMER 1. BRANCH CIRCUITS SHALL BE CONNECTED T020A,iP CB'S, U.N.O. 2. BRANCH CIRCUIT WIRING FOR 20 AMP, 120 VOLT CIRCUITS CONNECTED TO 208V/120 VOLT SYSTEMS SHALL BE, U.N.O.: A) ONE (1) BRANCH CIRCUIT PER HOMERUN- 0'-100' IN LENGTH: 2#12,1#12G,3/4"C 101'-170' IN LENGTH: 2#10,1#10G,3/4'C 171'-250'IN LENGTH: 298,1981 B) TWO (2) BRANCH CIRCUITS PER HOMERUN- 0'-100' IN LENGTH: 4#12,1#12G,3/4'C 101'-170' IN LENGTH: 4#10,1#10G,3/4-C 171'-250' IN LENGTH: 08,1#8G,3/4-C C)THREE (3)BRANCH CIRCUITS PER HOMERUN- 0'-100' IN LENGTH: 6#12,1#12G,3/4'C 101'-170' IN LENGTH: 6#10,1910G,3/4"C 171'-250'IN LENGTH: 6#8,1#8G,1"C 3. PROVIDE A DEDICATED NEUTRAL WITH EACH BRANCH CIRCUIT. 4. PROVIDE AN INSULATED GROUND WIRE WITH EACH CIRCUIT. > DOOR HOLD OPEN a EQUIPMENT IDENTIFICATION CURRENTTRANSFORMER HD HEAT DETECTOR $ P 2T SINGLE POLE MANUAL STARTER WITH THERMAL OVERLOAD PROTECTION FOR FRACTIONAL SINGLE PHASE MOTORS.'P'INDICATES PILOT LIGHTAND '27 INDICATES DOUBLE POLE GROUND SD SMOKE DUCT DETECTOR 2 MOLDED CASE CIRCUIT BREAKER (NUMBER INDICATES POLES) [DO DUCT DETECTOR —� SINGLE THROW SWITCH PULL STATION $ CABLE TERMINATION RTS REMOTE TEST SWITCH AND ANNUNCIATOR POT HEAD TS TAMPER SWITCH O UTILITY METER WF WATER FLOW DETECTOR (v-1 VISUAL ALARM DEVICE � AUDIBLE AND VISUAL ALARM DEVICE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel (� �VTI�'lIa>nd6arJaL DATE: \ 08/23/19 SP=NGA spin • strength • yoga FOXHOLE) CONSTRUCTION LTD. Gp�,l i�'�IL�]i u�axasoeasorems�ruaa¢ VIRTUAL � ENERGY SOLUTIONS 6252 W 59th STREET, CHICAGO, IL 60638 312.583.7023 W W W.VESCHICAGO.COM #AA26003751 _ i N m U L W C � U � ICUc- _ Q U U r LO U ``pOIII II IPTrill" 7T'''i PE11600637 '? STATE OF i ,CC VES project number: 190301 sheet title: ELECTRICAL SYMBOLS AND ABBREVIATIONS sheet number: E001 0 2018 Virtual Energy Solutions, Inc.