HomeMy WebLinkAboutP501 - PLUMBING DETAILSr
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 08/23/19
SP-NGA
spin • strength • Vega
1"DHW
1" DCW
ISOLATION
2" V VALVES
TEMPERATURE
B PRESSURE
RELIEF VALVE
FOXFIELD CONSTRUCTION LTD.
�p�l iC�LL�]i u�axasoeasorv¢s�ruaa¢
EWH-1
2 GAL. THERMAL
EXPANSION
TANK
VIRTUAL
DISCHARGE
AIR GAP PIPING
"DIN ST FLR.
FMIENERGY
4" W DRIP PAN
SOLUTIONS
OPLUMBING ELECTRIC WATER HEATER DETAIL 33 E. OGDEN AVE. SUITE 304
LA GRANGE IL, 60525
312.583.7023
W W W.VESCHICAGO.COM
4"VTR #AA26003751
y
TO EXISTING 1/2" DHR 1/2" DHR
WATER SERVICE 1" DHW 3/4" DHW 73
1 1/2" DCW 11/2" DCW —1 Val" DCW 1 Vcl" DCW 3r4" DCW MM> IN-2"V— —2"V— 2"V7�77 3"V 2"V W
of C.)V
0 0 0 3 3 3 3 n > o >
> � is
> LAV-1 LAV-1 LAV-1 kVH EWC-11]jUJ
VH VH (a coQ
WC-1 WGi U co
UR-1 WC-1 C
FD-1 - FD-1 FD-1
o FCO1 Lr) �
TO EXISTING U
SANITARY MAIN® r
PLUMBING RISER DIAGRAM
1 NTS
\c c. P649
PEIISO0637
w
'? STATE OF f ,R
VIES project number: 190301
sheet title:
PLUMBING DETAILS
sheet number:
P501
02018 Virtual Energy Solutions, Inc.