Loading...
HomeMy WebLinkAboutA111 Architectural Floor PlanARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN mr WALL WALL PARTIAL HEIGHT WALL ® PARTIAL HEIGHT WALL ® �o WINDOW/SIDELIGHT a¢ WINDOW/SIDELIGHT ® DOOR AND FRAME )SEE DOOR SCHEDULE) 97 DOOR AND FRAME NOT: IF IN GOOD CONDIOON, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE WI UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. 0 WALL WITH INSULATION 3YB"MRALSTUDS AT 16" O.C.I 111 11 ONE LAYER OF z/B" TYPE "XGYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING DEMISING WALL TO DECK WITH INSULATION 3% METAL STUDS AT 16" O.C.; ONE LAYER OF X TYPE''R" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/23/19 WALL THICKNESS METAL STUD EXISTING WIN MULLION PRE -FINISHED ALUMINUM RECEIVER TRIM- FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINEOFEXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT n WALL AT MULLION DETAIL Al l l NOT TO SCALE e AREA NOT IN CONTRACT AREA OF WORK GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PUN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 40R LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. CONFIRM THAT ALL EXISTING WALLS ARE FULLY INSULATED. IF NOi, PROVIDE NEW INSULATION AS REQUIRED. Alll TYP. PLAN NOTES A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR FRILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. OA02 PROVIDE PLYWOOD PHONE BOARD, 4'x8'xJ, PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. A03 NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE i0 BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. A04 PROVIDE COAT ROD AND SHELF AT THIS LOCATION; SEE DETAIL 2/A211 FOR MORE DETAILS. PROVIDE (2) BRUSHED CHROME DOUBLE COAT HOOKS AT MAXIMUM 48" A.F.F. FOR ADA COMPLIANCE AT THIS LOCATION. A05 PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. P01 PROVIDE POTABLE HOT AND COLDWATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING, OPROVIDE COPPER WATER LINE (POLYTUBE IS NOT PERMITTED) FOR P02 COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. ARCHITECTURAL PLAN 0 2' 4' 8' 16' MIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC.. AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART, WITHOUT ME WRITTEN CONSENT OF SCH07 DESIGN. CD O qZ W- lomm LJJ L U O N � F V=u mill >o a Z _- Jp� Rossinia 2 N�Z REVISIONS MARK RIPTION iiiiiiiim PROJECT NUMBER 2019.150 OJ. MGR DRAWN BY AS NIP 4TH FLOOR ARCHITECTURAL FLOOR PLAN >N AlII