HomeMy WebLinkAboutA121 Reflected Ceiling PlanLEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', LED LIGHT FIXTURE, 2'x2', LED 0 LIGHT FIXTURE, I'x4', LED o LIGHT FIXTURE, I'x4', LED LIGHT FIXTURE TRACK RECESSED LIGHT FIXTURE DIRECTIONAL RECESSED LIGHT FIXTURE WALL SCONCE LIGHT FIXTURE ® LIGHT FIXTURE, PENDANT NIL NIGHT LIGHT LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC LIGHT FIXTURE, 2'x2' FLUORESCENT, PARABOLIC 0 LIGHT FIXTURE, 1'x4', FLUORESCENT, PARABOLIC o LIGHT FIXTURE, I'x4', FLUORESCENT, INDIRECT LIGHT FIXTURE, TRACK 0 RECESSED LIGHT FIXTURE XP WAILSCONCELIGHT FIXTURE ® LIGHT FIXTURE, PENDANT ® EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE LIGHT SWITCH 3 LIGHT SWITCH, 3-WAY ND LIGHT SWITCH, DIMMER p SWITCH, PROJECTOR SCREEN IG SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP( *NE SWITCH, EXHAUST FAN /—� LIGHTCIRCUIT CEILING GRID, SUSPENDED, 2'x2' GYPSUM BOARD CEILING EXPOSED TO DECK LIGHT SWITCH 3 LIGHT SWITCH, 3-WAY t LIGHT SWITCH, DIMMER pp SWITCH, PROJECTOR SCREEN G SWITCH, GARBAGE DISPOSAL xE SWITCH, EXHAUST FAN UGHTCIRCUIT GYPSUM BOARD CEILING RELOCATED DIFFUSER, ® DIFFUSER, LAY-1 N, 2'x2' LAY-1 N, 2'x2' — RELOCATED DIFFUSER, ® DIFFUSER, LAY -IN, 1'X4 LAY-IN, 1 At RELOCATED DIFFUSER, m DIFFUSER, LAY IN, 4"x4' LAY IN, 4"x4' ® EXHAUST FAN, 2'x2' EXHAUST FAN, NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/23/19 GENERAL NOTES I. PROVIDE N EW BUILDING STANDARD CEILING GRID AND TILE UNLESS OTHERWISE NOTED. PROVIDE NEW 2X2 CEILING GRID TO MATCH EXISTING CORRIDOR HEIGHT. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE LIKE CEILING TI LES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMAANDIBC. LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE, FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY, IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI, OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED, PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. NEW DEVICES AND FACE PLATES TO BE WHITE. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. ® AREA NOT IN CONTRACT ❑ AREA OF WORK MECHANICAL NOTES wmiiiiiiiiiiiiiim MECHANICAL W OR IS LIMITED TO A DESIGNBUILDSCOPE AND 6 OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE NDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, 2. HVAC LAYOUT TO BE APPROVED PRIOR TO WORK BEING COMPLETED. FILTERS MUST BE CHANGED AT CLOSE OF PROJECT AND ALL THERMOSTATS MUST BE CALIBRATED AND AIR BALANCED, PROVIDE REPORT TO OWNER. PLAN NOTES R01 BUILDING STANDARD HVAC TO BE PROVIDED IN SERVER ROOM UNLESS NOTED OTHERWISE. REFLECTED CEILING PLAN 0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRRTEN CONSENT OF SCH07 DESIGN. CNI co C) Q WC4- I. LLJ O S 2 1 V=J Y • Z�~ Q � Q Z 0 aaa� Q JpLu Z REVISIONS MAR=RI"ON PROJECT NUMBER 2019.150 DRAWN BY NP 4TH FLOOR REFLECTED CEILING PLAN >N Al21