HomeMy WebLinkAboutA131 Finish PlanLEGEND GENERAL NOTES PLAN NOTES
FLOOR COVERINGS
NOTE: XXX MANUFACTURER PARTICIPATES IN SCHOTT
DESIGN'S RECYCLING NO COST ADD TO CLIENT OR PROJECT
PROCESS. REFER TO SCHOTT DESIGN DECONSTRUCTION
NOTES ON TI I I AND DI I I FOR PROCESS DETAILS.
CPTt MFG: TBD
TYPE:
PATTERN: --
COLOR: --
Opp MFG: TBD -
TYPE
PATTERN: —
COLOR: —
VINYL COMPOSITION TILE
VCiI MFG: TBD
SIZE: 12"xl2"
PATTERN: —
COLOR: --
MFG: TBD
SIZE: 12"XI2"
PATTERN: —
COLOR: —
RIEIII:Y�7�Plfilr
NOTE: AT ALL LVT LOCATIONS, PROVIDE SKIMCOAT OF
ARDEX LEVELING LATEX AS NEEDED FOR SMOOTH
SUBFLOOR THAT WILL NOT ALLOW FOR TELEGRAPHING
OF IMPERFECTIONS IN THE FLOOR
LVT1 MFG: TBD -
SIZE:
PATTERN: —
COLOR: —
WALL BASE
VBl MFG: TBD
TYPE: 4" VINYL COVE, ye" GAUGE
COLOR: --
PAINT / WALLCOVERING
PT1 MFG: SHERWIN WILLIAMS
TYPE: PROMAR 20
0 ZERO VOC INTERIOR LATEX
COLOR:
—
FINISH:
EGGSHELL
MFG: SHERWIN WILLIAMS
O TYPE:
PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR:
—
FINISH:
EGGSHELL
MFG: SHERWIN WILLIAMS
PT3 TYPE:
PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR:
—
FINISH:
EGGSHELL
PLASTIC LAMINATE / SOLID SURFACE
pLl MFG: TBD )COUNTERTOP)
COLOR: —
pUMFG: TBD )CASEWORK)
COLOR: —
ALL FINISHES TO BE SELECTED. FINISHES SHALL MEET ALL CLASS
FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL
BUILDING CODE.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
aT, CiityGF Camel
IVT�tDN�DMK
DATE: 08/23/19
I. REFER TO LEGEND FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
2. AT ALL FLOOR TILE LOCATIONS PROVIDE WATERPROOFING CRACK
ISOLATION MEMBRANE: TEC HYDRAFLEX FULL COVERAGE PER
TCNA F125-11 FULL. PROVIDE CONTROL JOINTS EVERY 12' AT
MINIMUM OR AS RECOMMENDED BY MANUFACTURER,
3. AT NEW WALLTILE LOCATIONS PROVIDE APPROPRIATE SUBSTRATE FOR
WALLTILE (AT EXISTING WALLS SCHLUTER KERDI BOARD OR EQUAL) (AT
NEW WALLS CEMENT BACKER BOARD) AS RECOMMENDED BY
MANUFACTURER.
E
AREA NOT IN CONTRACT
F01 PROVIDE SCHLUTER SCHIENE TRANSITION STRIP AT CARPET TO TILE
TRANSITION,FINISH: BRUSHED STAINLESS STEEL IEB). PROVIDE
LEVELING LATEX UNDER CARPET AS SUCH THAT TOP OF FINISHES
ARE LEVEL. SEAM SEAL CARPET EDGES. TRANSITION STRIP MUST BE
LEVEL WITH OR SLIGHTLY HIGHER THAN TILE EDGE. TRANSITION
PROFILE MUST BE APPROPRIATE FOR FLOORING MATERIALS AND
MUST BE SUBMITTED TO SDI FOR FINAL APPROVAL PRIOR TO
INSTALLATION.
F02 COORDINATE WITH PROPERTY MANAGEMENTS ON FINISHES.
FINISH PLAN
0
]'
4'
8'
16'
AREA OF WORK
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
I NTELLECIUAL PROPERTY OF SCHOTT
DESIGN. INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE. OR
IN PART. WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
N
0
Q
W4-
~Lw
0 =D
e Q
V=�
z `
a�Q
a
>Zo
__-
J w
Rossini
a �
•/ I � z
REVISIONS
MARMRIMON
PROJECT NUMBER
2019.150
PROD. MGR DRAWN BY
AS NP
4TH FLOOR
FINISH PLAN
>N A131