HomeMy WebLinkAboutE111 Electrical PlanLEGEND NEW CONSTRUCTION EXISTING TO REMAIN =�)N POWER OUTLET, DUPLEX may, 'PV POWER OUTLET QUADRUPLE% JQ JUNCTION BOX QJ CEILING MOUNTED J JUNCTION BOX © BOX, BLANK COVER PLATE BOX, OPEN QO P PROVIDE JUNCTION BOX P D ABOVE CEILING FOR O POWER POLE CONNECTION, POWER POLE BY OTHERS. POWER OUTLET, DUPLEX POWER OUTLET QUADRUPLE% JUNCTION BOX CEILING MOUNTED JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN POWER AND DATA POLE FLOOR BOX WTH POWER FLOOR BOX WITH POWER FI® AND DATA, FLUSH 6b AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH J I® JUNCTION BOX AND J 14 JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION DATA/COMMUNICATION Ii OUTLET (PROVIDE BOX b AND PULLSTRING ONLY) OUTLET DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42' HEIGHT OF ELECTRICAL OR DATA DEVICE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel �N;W�1t DATE: 08/23/19 e AREA NOT IN CONTRACT AREA OF WORK GENERAL NOTES I. TENANTS FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED I B'MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. RELOCATE EXISTING OUTLETS AT SAME HEIGHT AS NEW IF THERE IS A VARIANCE. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. ALL ELECTRICAL AND MAGNETIC HARDWARE AND CONNECTIONS TO BE COMPLETED BY TENANT'S SECURITY VENDOR. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. PLAN NOTES Eol COORDINATE COPIER RECEPTACLE WITH TENANT, PROVIDE DEDICATED RECEPTACLE AS REQUIRED. E02 PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM, COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. EOJ PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN, COORDINATE EXACT LOCATION WITH TENANT. IE04 COORDINATE EXACTSERVER ROOM REQUIREMENTS WITH TENANT. E05 PROVIDE POWER FOR TENANTS RECESSED MICROWAVE. ELECTRICAL PLAN 0 2' 4' R' 16' � Ra THIS DRAWING. AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOTTO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. CAI C'7 C) N qZ W- ~LUw 0N� e Q V=� Y Z�~ Q � Q > Z 0 J w Ja�E N�Z SSUE DATE DESCRIPTION 06/25/19 REVIEW SET REVISIONS MARK RIPTION PROJECT NUMBER 2019.150 PROD. MGR DRAWN BY AS NP 4TH FLOOR ELECTRICAL PLAN >N E111