HomeMy WebLinkAboutL100 Life Safety2 3 4 5 6 7 B 9 10 11 12 13 14 15 16 CODE SUMMARY SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE PREVIOUS USE OF SPACE BUSINESS( OCCUPANCY CLASSIFICATION BUSINESS( CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA VARIES SF/FLOOR X 1 8 STORIES = 214.546 SF TOTAL PROJECT AREA OCCUPANCY CALCULATIONS NUMBER OF EXITS 2,876 SF SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD GEN. OFFICE 2,876 SF too 29 TOTAL OCCUPANTS IN PROJECT AREA 29 REQUIRED.I PROVIDED:I SPRINKLERSYSTEM(YES/NO( YES- EXISTINGTO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 2,876 SF ACCESSORYAREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED( All ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN( BUILT BEFORE 1978? NO BUILDING CONSTRUCTIONTYPE I-B LEGEND Ep EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT `rFE FIRE EXTINGUISHER ® EXIT SIGN -LED EDGE LIT — — — TRAVEL DISTANCE O NIGHT LIGHT/EMERGENCY LIGHTING NIEL AREA NOT IN CONTRACT AREA OF WORK RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �N;M�1t DATE: 08/23/19 LIFE SAFETY NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANTS PACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES(, EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM 8. DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA(. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. ELECTRICIAN TO RELOCATE EXISTING. ANY NEW FIXTURES TO BE ADDED BY OWNER'S LIFE SAFETY VENDOR ONLY. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. FIRE EXTINGUISHERS PROVIDED BY TENANT. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY PLAN 0 4' 8' 16, THIS DRAWING. AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WRHOUF THE WRBTEN CONSENT OF SCH07 DESIGN. CV M C) w C Wq- ~LU Cw � C 0�� F V=� Z�~ > Q JpLLJ N�Z ISSUE DATE DESCRIPTION 06/25/19 REVIEW SET REVISIONS MAR=RI"ON PROJECT NUMBER 2019.150 PROD. MGR DRAWN BY AS NP 4TH FLOOR LIFE SAFETY >N L100