CODE SUMMARY
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
PREVIOUS USE OF SPACE
BUSINESS(
OCCUPANCY CLASSIFICATION
BUSINESS(
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
VARIES SF/FLOOR
X
1 8 STORIES
=
214.546 SF
TOTAL PROJECT AREA
OCCUPANCY CALCULATIONS
NUMBER OF EXITS
2,876 SF
SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD
GEN. OFFICE
2,876 SF
too
29
TOTAL OCCUPANTS IN PROJECT AREA 29
REQUIRED.I PROVIDED:I
SPRINKLERSYSTEM(YES/NO(
YES- EXISTINGTO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
2,876 SF
ACCESSORYAREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED(
All
ASHRAE 90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN(
BUILT BEFORE 1978?
NO
BUILDING CONSTRUCTIONTYPE
I-B
LEGEND
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT
`rFE
FIRE EXTINGUISHER
®
EXIT SIGN -LED EDGE LIT
— — —
TRAVEL DISTANCE
O
NIGHT LIGHT/EMERGENCY LIGHTING
NIEL
AREA NOT IN CONTRACT
AREA OF WORK
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�N;M�1t
DATE: 08/23/19
LIFE SAFETY NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANTS PACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES(,
EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM 8. DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA(. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
ELECTRICIAN TO RELOCATE EXISTING. ANY NEW FIXTURES TO BE
ADDED BY OWNER'S LIFE SAFETY VENDOR ONLY.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER. FIRE EXTINGUISHERS PROVIDED BY
TENANT.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE
EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET
ALL LOCAL AND STATE CODES.
LIFE SAFETY PLAN
0 4' 8' 16,
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WRHOUF THE WRBTEN
CONSENT OF SCH07 DESIGN.
CV
M
C)
w
C
Wq-
~LU
Cw
� C
0��
F
V=�
Z�~
> Q
JpLLJ
N�Z
ISSUE
DATE
DESCRIPTION
06/25/19
REVIEW SET
REVISIONS
MAR=RI"ON
PROJECT NUMBER
2019.150
PROD. MGR DRAWN BY
AS NP
4TH FLOOR
LIFE SAFETY
>N L100