HomeMy WebLinkAboutT111 Cover Sheet & General NotesMECHANICAL & ELECTRICAL NOTES GENERAL PROJECT NOTES
I. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO
BASIC DESIGN -BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE
DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY
FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL
OR PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY
ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF
ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE
MECHANICAL, ELECTRICAL AND PLUMBING DESIGN -BUILD CONTRACTORS SHALL
COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE
SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE
DESIGN -BUILD CONTRACTOR AN D MUST COMPLY WITH ALL APPLICABLE STATE AN D
LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN -BUILD
CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THEIR PLANS AND
OBTAINING THEIR PERMITS.
2. MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE
BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS
AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT
IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE
CODES.
3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANTSPACE, AND
PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY
PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY
SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING
OWNER/LANDLORD.
4. RELOCATE AIR -SUPPLY DIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED. PROVIDE
PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES.
LOCATION OF DIFFUSERS SHOWN ON PLAN IS FOR REFERENCE ONLY, CONTRACTOR
IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY
CODE.
5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL
OR OTHER CONFLICTS. PROVIDE BALANCE REPORTS TO OWNER UPON COMPLETION
OF PROJECT,
6. ELECTRICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF
THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL
PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHAN I CAL CODE AND ALL OTHER
APPLICABLE CODES.
B. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER
AND DATA OUTLETS AS REQUIRED.
9. ALL ELECTRICAL OUTLETS WITHIN 6-0 OF OF WATER ARE TO BE G.F.C.I.
10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO
BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS
AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE,
11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCH PLATES TO
MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO
PURCHASE,
12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN.
REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE
TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM
WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE
RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS.
13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE
SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING
ELECTRICAL CONDUITS TO JUNCTION BOXES.
14. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE
NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES,
15. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A.
REQUIREMENTS AND ARE CONSISTENT THROUGHOUT.
16. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE(1) GANG BOX WITH A SINGLE
COVER PLATE.
17. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWNLIGHTS,
SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED,
18. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.
EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES
SHOWN ON PLAN ARE FOR REFERENCE ONLY.
19. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY
SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM &
DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES
(INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA(. IN RECEPTION
AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL
LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO
INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE
ITEMS AT THEIR EXPENSE.
20. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION
DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE
WALLS (CONFERENCE ROOMS AND RECEPTION AREAS( AND TENANT -INSTALLED
ITEMS L.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS(.
21. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS
IN EXISTING SPACES. CONSULT WITH LANDLORD. ALL LAMPS ARE TO BE MATCHING
IN CRI AND MANUFACTURER.
22. NEW AND EXISTING PLUMBING LINES IN CEILING ARE TO TO BE INSULATED.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 08/23/19
I. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING
CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING
CODE.
2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE
AND LOCAL BUILDING CODES, CONTRACTORS ARE RESPONSIBLE FOR
VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR
RESPECTIVE SCOPE OF WORK.
3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE
DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING
CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE
THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY
AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK.
4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL
CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING
CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT
SCALE DRAWINGS, NOTED DIMENSIONS TAKE PRECEDENCE,
5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT
ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT
DESIGN, INC.
6. THE GENERAL CONTRACTORSHALL COORDINATE WITH THE OWNER
REGARDING ALL ON -SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK
SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE
WORKSITE, TRAFFIC CONTROL, AND BUILDING/PUBLICSAFETY PROCEDURES
DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE
WORK"BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE
THE OVERALL PROJECT SCOPE,
7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY
WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAYBE WORKED PRIOR
TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT
CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS
DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS.
8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME THE CONTRACTOR
SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND
COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN
DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE
PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT
RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO
COMMUNICATE MATERIAL LEAD TIMES.
9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED
WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR
SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER.
ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE
REQUEST AND RENDER A DECISION.
10. SCHOTT DESIGN,INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE
OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION
MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS
SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR
WORKERS AND THE PUBLIC AT ALL TIMES.
II. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER
TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT.
12, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN
AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER
AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING
REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE
DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS,
13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE
DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND
CONSTRUCTION WORK, DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4
WOOD STUDS ® 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH
SIDE.
14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE
DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT
THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS.
L.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE
INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN(.
15. SCHOTT DESIGN,INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION,
DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE
TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE
PROJECT SITE,
16. PROVIDE FIRE -TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG
ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC.
FINISH NOTES
I. ALL FINISHES SHALL COMPLY WITH CHAPTER 8(INTERIOR FINISHES( OF THE
INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS.
2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE
GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS,
TAPING DETAILS, CORNER BEADS, ETC.)
3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF
ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE
PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM
DESIRED COLOR PRIOR TO PURCHASING NEW,
4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2)
FINISH COATS.
5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR
OPENINGS AS NOTED ON FINISH PLAN (I.E. WHERE VCT MEETS CARPET).
6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING
WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE
SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR
TENANT AN D BUILDING OWNER.
7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED.
B. WHERE PHON E BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT
TO MATCH ADJACENT WALL FINISH.
9. SUBMIT FINISH SAMPLE OF MILLWORK(STAINED OR PAINTED AS SPECIFIED( TO
SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS
OF ALL MILLWORK.
10. REFERENCE INTERIOR ELEVATION &SECTIONS WHERE PROVIDED FOR
ADDITIONAL FINISH INFORMATION.
11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.
12, ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT
MANUFACTURER.
17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN,
INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR
CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE
DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL
NUMBER.
18, EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW
SUFFICIENT TIME FOR CHECKING APPROVAL ORDERING FABRICATION AND
DELIVERY OF MATERIALS AND EQUIPMENT.
19, ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST
QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR
NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL
WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING
CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL
CONSTRUCTION.
20. ALL DETAIES, MATERIALS, AN D I NSTALLATIONS ARE S U BJ ECT TO FI RST
APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER.
21. R EVI EW AN D COORDI NATE ALL N EW WORK A N D EXISTI NG CON DITIONS WITH
ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE
APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN
ACCOUNTED FOR BY THE BIDDER DURING PRE -BID FIELD INSPECTION AND
AFTER AWARD OF CONTRACT.
22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS,
VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS
DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ON LY
AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY
STATED TO BE PROVIDED.
23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT
REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION.
PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR
ADJOIN TO EXISTING CORE WALLS.
24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND
SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL TAPE
SPACKLE AND PREPARE FOR FINISH.
25. ALL EQUIPMENTAND/OR FIXTURES SHALL BE INSTALLED IN STRICT
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR
INSTRUCTIONS,
26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT
SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A
CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND
PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED
APPLIANCES WORK & DO NOT LEAK.
27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS,
OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF
THE PROJECT.
28, ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW
GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL.
DO NOTSCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN.
29, CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING
WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS
WITH NEW TO MATCH BUILDING STANDARD.
30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS,
AND FEES. THE GEN ERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
SUBMITTING ALL REQUIRED DRAWINGS AN D SUPPORTING DOCUMENTS TO THE
LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED
LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS
STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT.
31, FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS
WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.
32. WHERE STRUCTURAL BEAMS,DUCTWORK, ETC. PENETRATE SOUN D OR FIRE
RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT,
CAULKED AND FIRE DAMPERED IF REQUIRED.
33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT
NECESSARILY AN INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON
LI 00 IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION,
34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING
FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED
TO RECEIVE NEW CONSTRUCTION AND FINISHES, ADJUST DOORS AND FRAMES
AS REQUIRED.
DECONSTRUCTION NOTES
I. DECONSTRUCTION DEFINITION: CAREFULLY DISMANTLE SPACES WITH THE GOAL OF
MAXIMIZING THE REUSE POTENTIAL OF ITS COMPONENTS,
2. ALL ITEMS SHOWN ON THE DECONSTRUCTION PLAN HAVE BEEN CAREFULLY
CONSIDERED FOR RECOVERY, REUSE, AND RECYCLING WITH THE BEST INTENTTO
DIVERT ITEMS FROM THE LANDFILL, REFER TO DECONSTRUCTION MANAGEMENT
CHECKLIST FOR SPECIFIC INSTRUCTIONS.
3. GENERAL CONTRACTOR IS RESPONSIBLE FOR RECYCLING ANY AND ALL POSSIBLE
PROJECT MATERIAL WASTE AND COORDINATING THE APPROPRIATE HAULING
CONTAINERS WITH THE WASTE MANAGEMENT SUB -CONTRACTOR.
4. NO STRUCTURAL OR LOAD -BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS
DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD,
PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT
STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE
FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL
OR OTHERWISE LOAD -BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS
THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL.
EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS
ADJACENT TO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY
RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM,
5. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF
THE BUILDING TO BE REUSED IN THE PROJECTAREA, THE CONTRACTOR SHALL INCLUDE
IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE
REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE
DIRECTED BY OWNER.
6. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR
DASHED LINES, NOTE THATSOME ITEMS HAVE NOT BEEN SHOWN ON
DECONSTRUCTION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF
DECONSTRUCTION .
7. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS
REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING
CONDITIONS. REFER TO FINISH PLAN SCHEDULE FOR CLARIFICATION OF EXISTING
FINISHES i0 REMAIN.
B. USE CARETO PROTECTEXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS
TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE
SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND
FINISHES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S
COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE
OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION
FOR THE OWNER'S USE IN THE PROJECT,
Y. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF
COMBUSTION( REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND
WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING,
FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC
CABLES/RACE WAYS, AND PLTC CABLES, REFER TO SECTION 300,21, ANY SUCH
CABLE OR WIRING SHOULD BE PULLED AND REMOVED BACK TO THEIR MAIN SOURCES
ON THE FLOOR (I.E. ELECTRICAL PANELS, PHONE BOARDS, ETC.(
10. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING,
MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE
CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND
GOVERNING SAFETY REGULATIONS OR PROCEDURES. TAKE BACK TO SOURCE IF NOT
BEING REUSED. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE
REFERENCE. CONTRACTOR TO PROVIDE AN"AS-BUILT'SET INDICATING THE LOCATION
OF ALL PERMANENTLY ABANDONED SYSTEMS,
11. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING
OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,
DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.
12. GENERAL CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ANY AND ALL ITEMS THAT
MAY CONTAIN HAZARDOUS OR HARMFUL MATERIALS. ALL IDENTIFIED ITEMS MUST BE
PROPERLY DISPOSED OF PER EPA AND IDEM RULES AND REGULATIONS.
13, GENERAL CONTRACTOR TO PROVIDE ANY COST RELATED TO SORTING AND
RECYCLING, AS WELL AS ALL SCRAP METAL INCOME, AS PART OF THE
DEMOLITION/DECONSTRUCTION BASE BID.
14, GENERAL CONTRACTOR MUST OBTAIN AND PROVIDE TO OWNER RECEIPTS ON ALL
RECYCLED ITEMS INCLUDING CREDIT FOR METALS.
MILL/CASEWORK NOTES
I. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE
PROVIDED UNDER THE GENERAL CONTRACT.
2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE
FIRE PROTECTION NOTES
(A.W.I.'CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.
�.
3.
FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE
TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION.
I. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
4.
WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
PLANS AGAINST DIMENSIONS OF AS -BUILT CONDITIONS INFIELD. REPORT ANY
DISTANCE OF75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING
SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS,
2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE
S.
VERIFY FINISHES (LAMINATE VENEER, STAINS, ETC.( ON THE SECTIONS AND ELEVATION
GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT
DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY
DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR
REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL
RENOVATION OF THE FIRE SPRINKLER SYSTEM.
CONTRACTOR.
3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING
6.
REFER TO MILLWORK SECTIONS & ELEVATIONS. UNLESS OTHERWISE SHOWN, PLASTIC
CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES
LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED,
AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE
BACKSPLASHES TO BE FIELD APPLIED.
SPRINKLER/FIRE SUPPRESSION SYSTEMS,
7.
EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS,
LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE,
AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE
IF PVC EDGING IS BEING PROPOSED BY FABRICATOR FOR EDGES OF CABINETS AND
AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT,
DRAWERS, FABRICATOR MUST PROVIDE SAMPLE OF COLOR MATCHING SPECIFIED
5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE
PLASTIC LAMINATE FOR APPROVAL.
MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.
8.
REFER TO MILLWORK SECTIONS& ELEVATIONS FOR CABINETRY SPECIFICATIONS
FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK.
(CUSTOM PLASTIC LAMINATE OR PRE -MANUFACTURED STOCK CABIN ETRYL
6, FIRE STOP ANY EXISTING DECK PEN ETRATIONS.
9,
TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND
CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.
DOCUMENT APPROVAL
TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS.
TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE
ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT,
THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.
VICINITY MAP
NOT TO SCALE
KEY PLAN - 4TH FLOOR
N
NOT TO SCAIE
1917�3�7�7wky' 919[e'l
TIII COVER SHEET AND GENERAL PROJECT NOTES
Ll00 LIFE SAFETY PLAN
DI I I DECONSTRUCTION PLAN
At I I ARCHITECTURAL FLOOR PLAN
A121 REFLECTED CEILING PLAN
AI3I FINISH PLAN
A211 DOOR SCHEDULE/ INTERIOR DETAILS
EIII ELECTRICAL PLAN
THIS DRAWING. AND ME IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN. INC., AND ARE NOT TO 5E
USED OR REPRODUCED IN WHOLE. OR
IN PART WITHOUT ME WRITTEN
CONSENT OF SCH07 DESIGN.
CV
C)
NO
Q
W 44T z
V
J
LU
G
0(n�
V U
Y
Z�~
Q5Q V')
G
Q
Z
R!• Q
wC
Q
y�Z
ISSUE
DATE DESCRIPTION
06/25/19 REVIEW SET
REVISIONS
MARK DATE DB DESCRIPTION
PROJECT NUMBER
RiIIIL'J1Fi1JR�
PROJ. MGR DRAWN BY
AS NIP
4TH FLOOR
COVER SHEET AND
GENERAL NOTES
T111