Loading...
HomeMy WebLinkAbout18-840.01 A803 FINISH SCHEDULES-A803N4a4:14ki14 W11►I I. FURNISHED BY OWNER, INSTALLED BY OWNER' MILLWORK, TOOLS, CARTS, WORKBENCHES, OL LINES, FURNITURE, BREAKROOM SEATING, PARTS BINS, AIR COMPRESSOR, AIR UNE5, BULK OL TANKS, WATER/AIR/OIL REELS, EXTERIOR SIGNAGE, INTERIOR SIGNAGE, VENDING MACHINES, APPLIANCES (EXCEPT GARBAGE DISPOSAL) G KEY MACHINES. CONTRACTOR TO INSTALL UTILITIES SERVING OWNER PROVIDED EQUIPMENT 2. LIFTS INSTALLED BY OWNER - BLOCK OUT FOR CASSETTE S ELECTRICAL HOOK-UPS BY GENERAL CONTRACTOR. 3. WATER ONES AT SERVICE AREA INSTALLED BY GENERAL CONTRACTOR. WATER LINES SHALL TERMINATE WITH HOSE BIBS BY GC. FINAL HOOK-UP OF EQUIPMENT INSTALLATION AND REELS BY OWNER. 4. MILLWORK AT BREAK ROOM5, CUSTOMER COUNTERS G TOILETS TO BE HC ACCESSIBLE. MAX HEIGHT OF COUNTERS ABOVE FLOOR TO BE 34 INCHES. 5. INTERIOR SIGNAGE, FOR INDIVIDUAL ROOM IDENTIFICATION TO BE MOUNTED AT 41 AFF TO CENTER OF SIGN W/ BRAILLE CHARACTERS, IS PROVIDED AND INSTALLED BY OWNER. 6. MIN, 5% OF TABLES IN BREAK ROOMS, WITH A MINMUM OF ONE, SHALL HAVE TOPS AT ACCESSIBLE HT, BETWEEN 28" AND 34" AFF. COUNTERTOPS OF BASE CABINETS IN BREAK ROOMS TO BE AT 34" AFF, 1. FURNISH AND INSTALL 'KNOX BOX" PER COUNTY OR CITY REQUIREMENT'S AT LOCATION TE D. 8. DURING CONSTRUCTION, BUILDING AND SITE TO BE KEPT IN VERY CLEAN AND ORDERLY CONDITION AT ALL TIMES. PROJECT CONSTRUCTION SIGN TO BE LIMITED TO (1) 4 FT X 5 FT SIGN, S. GO TO INSTALL LIGHTING AND SPRINKLER HEADS FOR BOTH LEVELS. 10. SEE A503 FOR CORNER GUARD DETAIL SEE A503 FOR WALL GUARD DETAIL II. I HR RATED CONSTRUCTION INDICATED BY DASHED UNE: I HR RATED METAL STUD CONSTRUCTION PER UL DESIGN U41% I HR RATED MASONRY CONSTRUCTION PER UL DESIGN US05. 11 INSTALL ACCESS PANELS IN CMU UTILITY CHASES IN SERVICE SHOP, EQUAL TO ACUDOR UF-5000. PAINT Iii 11 REFER TO CIVIL DRAWINGS FOR INFORMATION ON CONCRETE WALKS, PATTERN CONCRETE AND PAVING AROUND THE BUILDING. ALL SITE WORK IS RESPONSIBIUTY OF OVIL DRAWINGS, 14. UTERATURE DISPLAY RACKS BY OWNER'S MILLWORK VENDOR. 15. INSTALL CORNER GUARDS PER DETAIL A803 WHERE INDICATED BY `GG'. 16. PROVIDE BLOCKING IN WALLS FOR ALL OWNER PROVIDED MILLWORK. TYPICALLY OFFICES AND SNUBS HAVE ONE UPPER CABINET. MILLWORK AT BREAK ROOMS AND WORK ROOMS WILL HAVE BASE AND UPPER CABINETS. Il KEY MACHINES LOCATED IN WORK ROOM AND ALIGNMENT EQUIP TO BE PROVIDED AND INSTALLED BY THE OWNER. GC TO PROVIDE POWER AND DATA CONNECTIONS. 18. HONDA TO PROVIDE AND INSTALLED BY OWNER. GC TO PROVIDE FOUNDATIONS AND ELECTRICAL CONNECTIONS TO PORTALS FOR SIGNAGE. SEE A 401, EXTERIOR ELEVATIONS FOR LOCATIONS. 15, ALL EXTERIOR BUILDING SIGNAGE PROVIDED AND INSTALLED BY OWNER, GC TO PROVIDE ELECTRICAL CONNECTIONS TO SIGNS. SEE A401, EXTERIOR ELEVATIONS FOR LOCATIONS, 20. PROVIDE GARBAGE DISPOSALS AT BREAK ROOM SINKS. SEE PLU INC. 21, WHERE THERMOSTATS AND WALL SWITCHES OCCUR SIDE BY SIDE, MOUNT DEVICES AT 48" AFF WHERE THERE IS NO WALL GUARD IF WALL GUARD IS AT SAME LOCATION, MOUNT DEVICES AT 54" AFF. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08i27i19 y1►11;�MEN ►[Q1*01 I. JONTS AT TILE BASE TO ALIGN all JONTS AT FLOOR TILE. 2. PRIOR TO LAYING TILE AROUND RECEPTION DESK, VERIFY EXACT PLAN OF RECEPTION DESK WITH ARCHITECT G MILLWORK SUPPLIER. 3. GENERAL CONTRACTOR TO PROVIDE AND INSTALL BASE AT ALL OWNER SUPPLIED MILLWORK. 4. VERIFY LOCATION OF FLOOR BOXES W/ OWNER OR ARCHITECT PRIOR TO INSTALLATION. VERIFY W/ ELECTRICAL POWER S SIGNAL PLAN. 5 VERIFY LOCATION COMMUNICATION PLATFORM PRIOR TO INSTALLATION OF FLOOR TILE AND OUTLET BOXES. S. CONCRETE POLISHING S STAINING PROVIDED AND INSTALLED BY OWNER G.C. TO COORDINATE SCHEDULING W/ OWNER. 1. INSTALL 3W' STAINLESS STEEL DIAMOND PLATE X 45" H TO CM LOW WALLS AND TO DRYWALL PARTITIONS UP TO WALL GUARD, U.N.O. B. INSTALL CORNER GUARDS PER DETAIL A503 AT OUTSIDE CORNERS AT AREAS INDICATED III 9 INSTALL TACK BOARD PANELS AT SIDE WALLS OF TRAINING ROOM PER A803. 10, AT PARTS SHOP 125, PARTS DELIVERY, PARTS 201, BODY SHOP 123, INSTALL 5/5" IMPACT RESISTANT GYP. BD UP TO 8 FT AFF THEN 5/8" GYP. BD TO DECK ABOVE 11, AT STAIRS, PAINT GUARD RAILS AND HAND RAILS P-5, 5WT065 IRON ORE, 12, REAR WALL OF ALL OFFICES TO GET ACCENT COLOR, P-1, WC-2 OR WC-3, PER OWNER'S DIRECTION 13. CONTRACTOR TO PAINT ALL EXTERIOR LIGHT POLES. DARK COLOR BASE UP TO 60", THEN WHITE ABOVE TO TOP 14. APPLY CEMENT PLASTER SKIM COAT OVER CMU WALL (EXCLUDE FURRED WALLS), UP TO JUST ABOVE CEILING OR UNDERSIDE OF JOST W/ARDEX RI SMOOTH FINISH COAT TO HIDE MORTAR JONTS S CMU TEXTURE. PAINT PER WALL SCHEME NOTED IN SCHEDULE. 15. WHERE APPLICABLE, ALL TILE BASE GROUT LINES SHALL ALIGN WITH FLOOR GROUT LINES. TYPICAL EXTERIOR METAL STUD CONNECTION NOTES I. a" THICK FIRE RETARDANT TREATED PLYWOOD SHEATHING, PROVIDE N8 - I g' 6-12 ROCK -ON SCREWS AT 8" I ALONG STUD SPAN FOR PLYWOOD TO METAL STUD FLANGE CONNECTION. 2. (4) w10 TEKS FOR METAL STUD TO METAL STUD CONNECTION. 3. PROVIDE 16GA. CLIP ANGLES W/(4) #10 TEKS FOR CLIP TO METAL STUD WEB CONNECTION $ (4) 12 - 24 X 1 y' TEKS FOR CUP TO STEEL MEMBER CONNECTIONS MAKE CUP ANGLE FULL WIDTH/HEIGHT OF METAL STUDS. 4. PROVIDE 16GA. CUP ANGLES W/(4) #10 TEKS FOR CUP TO METAL STUD WEB CONNECTIONS $ (4) q' 0 X I I" TAPCONS FOR CUP TO CMU WALL CONNECTIONS. MAKE CUP ANGLE FULL WIDTH/HEIGHT OF METAL STUDS. 5 ALL EXTERIOR METAL STUD FRAMING TO BE Iei STUDS (OR AS SPECIFIED IN STRUCTURAL DRAWINGS B SECTIONS) S SPACED AT 16" OC. U.N.O. IN THESE DRAWINGS. INTERIOR FRAMING NOTES I. ALL INTERIOR METAL STUD FRAMING SHALL BE MIN. 25GA. STUDS SPACED A W' O C. U.KOO IN THESE DRAWINGS. 2. ALL INTERIOR METAL STUD BRACING SHALL BE MIN. 25GA. STUDS SPACED A 32" O.C. OR 48" OC. A5 REQUIRED FOR APPLICATION. SCHEME F SCHEME F SCHEME F SCHEME F ROOM FINISH SCHEDULE ROOT NUMBER ROOM NAME FLOOR BASE WALL SCHEMES, CEILING REMARKS NORTH SOUTH EAST WEST lea VESTIBULE CPT-4, CT-2 101 RECEPTION CT-2 CTB-2 SCHEME F SCHEME F SCHEME F SCHEME F ACT-1 let VEHICLE DISPLAY OT-1 CET -I SCHEME F SCHEME F SCHEME F SCHEME F ACT-1 103 CONSULTATION AREA CT-2 CTB-2 SCHEME F SCHEME F SCHEME F SCHEME F ACT-1 104 FEATURE VEHICLE OT-2 CTB-2 SCHEME F SCHEME F SCHEME F SCHEME F ley CONSULTATION AREA OPT-2 Iii SCHEME B SCHEME B SCHEME a SCHEME B ACT-1 106 INFORMATION CENTER CPT -I Iii SCHEME B SCHEME B SCHEME B SCHEME B ACT-1 101 FBI OPT -I III SCHEME B SCHEME B SCHEME a SCHEME 6 ACT-1 105 SALES MANAGER CT-2 CTB-2 SCHEME K SCHEME K SCHEME K SCHEME K ACT-1 10S F Q 1 MANAGER OPT-1 FBI SCHEME B SCHEME B SCHEME B SCHEME 6 ACT-1 110 GENERAL MANAGER CPT -I FISH SCHEME B SCHEME B SCHEME B SCHEME B ACT-1 III JAN. ROOM CT-5 CIE-6 SCHEME A SCHEME A SCHEME A SCHEME A ACT-1 112 UTNTY ROOM CT-5 GT H5 SCHEME A SCHEME A SCHEME A SCHEME A ACT-1 113 WOMENS CT-5 CIE-6 SCHEME A SCHEME A SCHEME A SCHEME A ACT-1 114 HENS CT-5 GT H5 SCHEME A SCHEME A SCHEME A SCHEME A ACT-1 115 HALL CT -I GTE-1 SCHEME E SCHEME E SCHEI-E E SCHEME E ACT-1 116 HALL CT -I CTB-I SCHENE E SCHEME E SCHENE E SCHEME E ACT-1 In CUSTOMERS WAITING GPT-I Iii SCHEME E SCHEME E SCHENE E SCHEME E ACT-1 116 BDC CPT-2 FISH SCHENE 3 SCHEME B SCHENE B SCHEME B ACT-1 115 HALL CT-1 Cli 5CHEME E SCHEME E SCHEME E SCHEME E ACT-1 120 Fill GPT-I RBM SCHEME B SCHEME B SCHENE B SCHEME B 'ACT-1 121 F Q I CPT-1 FISH SCHEME B SCHEME B SCHENE n SCHEME B ACT-1 122 Fill CPT -I RBM SCHEME B SCHEME B SGHEME B SCHEME B 'ACT-1 123 SERVICE RECEPTION GT-14, CT-15 CT-14 SCHEME G SCHEME C SCHEME C SCHEME C ACT-1 124 SERVICE WRITE UP CT-14, CT-15 CT-14 SCHEME C SCHEME C SCHEME C SCHEME C ACT-1 125 SVC SPT SPT-2 III SCHEME B SCHEME B SCHEME B SCHEME B ACT-1 12 , SVC SPT SPT-2 FISH SCHEME B SCHEME B SCHEME B SCHEME B ACT-1 121 MECHANICAL CT-14, CT-15 CT-14 6GHEME C SCHEME C SCHEME C SCHEME C ACT-1 128 PARTS BOUTIQUE CT-14, CT-15 CT-14 SCHEME C SCHEME C SCHEME C SCHEME C ACT-1 FOR WALL SCHEMES DETAILED SEE SWEET A 804. AL50, SEE SHEET A 801 FINISH PLAN FOR WALL SCHEME LOCATIONS CALLED OUT. mn s� V� o a Q d co iv a� `mw 10a Q ry m '- nLL TDGArchitects.com PIEWS71W Automotive 0 It N T9 EL J Z D W d 0 of O ca -0 N IX W i C ) QLi a) 0 qJ W = N Q LL Tn Q N i- L) W a)Wm 9)zQoCZL0o o O W v= W LO o a Z 0 v U a N m REVISION SCHEDULE DATE DESCRIPTION 12/4118 CLEINT RENEW 12/28/18 HCNDA REVIEW 4/5/I5 REVIEW FOR PERMIT 6/26/I5 PERMITS STATE OF DRAWN BY: MEH CHECKED BY: BSJ a `E z 2 s VJ f fy a ws E� J '3 m U) LIJ cc Z 3 o U. F Project Number 18=840w01 Drawing Number A 803