HomeMy WebLinkAboutE 301UP III 0 0 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes e City of Camel ((�� �{vthl�lllanrklaAaL DATE: \ 08/27/19 �i21i �3 14� POWER NOTES: 1. NO MECHANICAL DUCTS, PIPING OR EQUIPMENT SHALL BE INSTALLED IN OR ABOVE ELECTRICAL EQUIPMENT SPACE PER N.E.C. COORDINATE PANEL INSTALLATION LOCATIONS WITH MECHANICAL CONTRACTOR. i 2. REFER TO MECHANICAL FLOOR PLANS, SCHEDULES AND DIAGRAMS FOR EXACT LOCATION OF EQUIPMENT AND WIRING REQUIREMENTS. ACC 3. ELECTRICAL TRADES CONTRACTOR SHALL COORDINATE ELECTRICAL OUTLET LOCATIONS 2 +1 /12 cRD 4•C WITH THE OWNER, ARCHITECTURAL TRADES ELEVATIONS AND/OR EQUIPMENT y AUTO FLUSH AUTO FLUSH 1 TO Pe- PB-9 I- EE -- - - - - -- - - - MANUFACTURER'S REQUIREMENTS PRIOR TO ROUGH -IN INCLUDING FLUSH FLOOR \/L q(Ty') SENS UIS (Tm) New Osa-aP ) OUTLETS. PANEL—�1-T QO 300A PB-19� PB-21� FBI P 0 I' —� 4. ELECTRICAL TRADES CONTRACTOR SHALL VERIFY FUSE AND WIRE SIZES FOR ALL 0 0 o TRANSF 9-I Bpi MECHANICAL AND MISCELLANEOUS EQUIPMENT, ETC., PER MANUFACTURER'S XWCP-I , it REQUIREMENTS AND/OR SHOP DRAWINGS. PROVIDE ALL NECESSARY STARTERS, HALL aT'oom T °O 1NW 1 n THERMAL OVERLOADS, INTERLOCKING, 120 VOLT CONTROL WIRING, DISCONNECT na MEN's J 11z 111 B�33P _ �}SWITCHES, ETC. REQUIRED FOR A COMPLETE INSTALLATION. MAKE ALL NECESSARY PS_ it REVISIONS. FOR THE EXACT LOCATION OF ALL ROOF MOUNTED MECHANICAL EQUIPMENT, 3 - - •tj �O` `\ SEE MECHANICAL DRAWINGS. VERIFY EXACT CONDUIT STUB -UP LOCATIONS IN FIELD. • 14 XP NAGEIR SENSOR a TOWEL no�1 \ _ it 5. GROUND -FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL SHALL BE PROVIDED PB-8 SOAP SENSOR S n INFORMATION v - d SENSOR a 2 F6-11 CENTER 1 AS REQUIRED IN 210.8 (A) THROUGH (C). THE GROUND -FAULT CIRCUIT -INTERRUPTER pB_ 9_2 J PB-6 ° PB-11' 60• to -o� P8-27% `- / COVERED POnr�R SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION. OTHER THAN DWELLING PB 2 i \`\ 0 UNITS, ALL 125-VOLT, SINGLE PHASE. 15A AND 20A RECEPTACLES INSTALLED IN THE B Oaa FAUCET - - - -oT• - - - - - - LOCATIONS SPECIFIED IN 210.8(B)(1) THROUGH (8) SHALL HAVE GROUND -FAULT s0R ALL _ �� �- CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL, GFCI RECEPTACLE TYPE OR GFCI Ewc—I ne � _ "'" - CONSULTATION CIRCUIT BREAKER IF NOT READILY ACCESSIBLE. ( ) U P PB-1 SENSOR P8-1 PB-10 SENSOR (ttP)FAUCLL PS-15 ems` AREA v I' l I � pg_1p too P8, 6. ON ALL EXHAUST FANS (EF'S), 120 VOLT SERVICE DISCONNECT SWITCHES SHALL BE j FURNISHED AND INSTALLED BY MECHANICAL TRADES AND WIRED BY ELECTRICAL TRADES. 2 #12 +1 J11 0 rGRID a•_ \-- �� y�N TO Pe 35468 (�P8 2 CU-1 it 7. ALL 20 AMP BRANCH CIRCUITS LONGER THAN 100'-O• SHALL UTILIZE A MINIMUM OF Fa' ` /�A (20A-2P C.B.) 1 208V-10 110 WIRES FOR VOLTAGE DROP. ALL 30 AMP BRANCH CIRCUITS LONGER THAN a svcr """toyw / lyp—J�/17.3 YCA '' 10O'-O" SHALL UTILIZE A MINIMUM OF /8 WIRES FOR VOLTAGE DROP. MAXIMUM OF 3% 14'-1• 30/2 i AT DESIGN LOAD. 8. CIRCUIT NUMBERS INDICATED, SHOW INTENT ONLY. ELECTRICAL TRADES CONTRACTOR i 1 -' CUSTOMER'S PB-39 L-------------------- ----A ------------- ---------- -------------------- > �� I __________________ _____________ ___________ SPARE BREAKERS WHEREVER P 0 SERVICE F VOLT 0A- P CIRCUIT BREAKER IN EXISTING PANEL INDICATED, (MAXIMUM OF 1800 ' SHALL FIELD VERIFY EXISTING PANEL CONDITIONS AND CIRCUIT ACCORDINGLY. UTILIZE TIT A H POSSIBLE TO FEED NEW EQUIPMENT OR PROVIDE NEW 12 c 11 _ ____ 2 1 R D MA wxREw 1 17V OUTLETS I J __ _ WATTS PER BRANCH CIRCUIT. SERVICE t24 11 PS-40 I HP-1 — T . _ '�� ) RECEPTION (VERITY III t23 1 SALES LOCATION WITH •i I bwlc� 9. A CEILING PLENUM SYSTEM MAY BE USED THROUGHOUT. ALL MECHANICAL $ MANAGER c ARCHITECTURAL I DISPLAY ELECTRICAL WORK LOCATED IN THE PLENUM CEILING SHALL BE INSTALLED USING toe ELEVATIONS) I 1Gz a PLENUM RATED MATERIALS. ________ _____________O- VESTIBULE h Ll�i2 tat 10. THIS CONTRACTOR SHALL SAW CUT AND PATCH THE EXISTING CONCRETE FLOOR SLAB +' IA AS REQUIRED FOR INSTALLATION OF NEW ELECTRICAL DEVICES, CONDUITS AND WIRE, •i - -- �F.B UNDERGROUND UTILITIES AND ROUGH -IN LOCATIONS WITH EQUIPMENT SUPPLIER'S I Pa-n APPROVED SHOP DRAWINGS BEFORE INSTALLATION. III eDC -- - - - -•��- n �- - - - - - 11 THIS CONTRACTOR SHALL PROVIDE NEW CHASE IN EXISTING DRYWALL S REQUIRE FOR -.� ^ J �� r------------ --- --- --- - ------ --- -- ----------------- NEW CONCEALED CONDUIT AND DEVICES. HPATCH EXISTING WALL WITHAPPROVED - 121_81 4• — _ i_ _ — _ _ MATERIAL TO MAINTAIN THE WALL RATING. •_� , • �______________________ I •T O p8_1BI� __J___Iul_i_____a 1 12. ELECTRICAL OUTLETS ON WALES THAT ARE TO BE FURRED OUT ARE TO BE EXTENDED T tw OUT FLUSH WITH NEW WALL SERVICE. REWIRE AND RECONNECT AS REQUIRED. 13. ELECTRICAL TRADES CONTRACTOR SHALL VERIFY POWER REQUIREMENTS, CONDUIT AND •„ �• " •i \� iu WIRE SIZES FOR THE PRE -WIRED FURNITURE SYSTEM PER MANUFACTURER'S LEI REQUIREMENTS AND/OR SHOP DRAWINGS. VERIFY WITH FURNITURE LAYOUT FOR EXACT 208V-tA U \ 17'-5• ' IiL 1 POWER AND TELEPHONE/DATA JUNCTION BOX LOCATIONS. THESE CORRESPOND TO THE .75 HP 1 HAu \ PS-20� y iii 11 SYSTEMS FURNITURE BASE FEED LOCATIONS. ELECTRICAL RECEPTACLES ARE PROVIDED NI, tta _____ ___ ___________ L__ ___ ___ __________u__ .Ii_i----- J WITHIN THE BOTTOM TRIM/RAIL OF THE SYSTEM FURNITURE PANEL. PROVIDE PANEL �A ` BREAKER HANDLE -TIE FOR FURNITURE CIRCUITS TO TRIP TOGETHER PER N.E.C. GRD 3/:•G MECHANICAL TO P8-35, 37 17/ Pi 14. CONTRACTOR SHALL VERIFY EXACT WIRING REQUIREMENTS WITH MANUFACTURER AND/OR (15A-2P C.B.)o.l' CONSULTATION Ilii SHOP DRAWINGS FOR PLUMBING FIXTURES (I.E. WATER CLOSETS, TOWEL § SOAP AREn (/ i' DISPENSERS TRANSFORMERS BY MECHANICAL TRADES. JUNCTION BOX MOUNTED ABOVE /, na �� 11 CEILING WHERE APPLICABLE. SOAP DISPENSER GFI RECEPTACLES MOUNTED BELOW FaI FaI o� FaI o FEATURE VEHICLE COUNTER. VERIFY WITH PLUMBING CONTRACTOR FOR EXACT LOCATION PRIOR TO 122 121 12a �/ IIII ROUGH -IN. (LOW VOLTAGE) / ILA �> 1 III i / _J_ P8-9 _ •� PB-� p 1i 15. ALL RECEPTACLES IN COUNTER AREA TO BE MOUNTED ON INSIDE WALLS OF CABINETS. -- L ---------------- ® lam.'// ROUTE CONDUIT AND BRANCH WIRING THRU BASE CONCEALED. 5'-4• .� a ' 16. INSTALLATION OF RECEPTACLES, EQUIPMENT AND BRANCH CIRCUIT WIRING ETC. IN aPB 28 6� p SERVICE DEPARTMENT, SERVICE WRITE-UP, WASH BAY AND PREP BAY AREAS SHALL BE IN ACCORDANCE WITH ARTICLE 511 OF THE LATEST N.E.C. ALONG WITH SEAL -OFF _ _ _ _ _ _ _ _ _ _ _ 1 _ _ 1 -� FITTINGS FOR ALL CONDUITS THAT TERMINATE IN OR PASS THROUGH THE 18• BARRIER T U T �K ' ABOVE FINISH FLOOR AND WITHIN 18. OF THE CEILING PER ARTICLE 511 OF THE N.E.C. L---------------------- u__Lu+_i_____7 FOR COMMERCIAL GARAGES, REPAIR AND STORAGE. 1 1 1 __ I__� I11I_----- I 1 = KEYED NOTES: III 11I 11 0 (E) EXISTING TO REMAIN. MAINTAIN CIRCUIT INTEGRITY. --------------- ----- —L,--111u1'+-----,I DISCONNECT AND REMOVE BRANCH CIRCUIT AND CONTROLS FROM EXISTING EXHAUST FAN. `—------------- ---- -- J REUSE CIRCUIT TO FEED NEW EF-1. i -------------------------------------------------------------------------------- O DISCONNECT AND RELOCATE EXISTING ELECTRICAL PANELS. EXTEND BRANCH CIRCUIT TO I NEW LOCATION AND RECONNECT. FLOOR PLAN - POWER SCALE: 1/8"=V-0" `_ D' s 15, DEMOLITION GENERAL NOTES: 1. THIS DRAWING IS ONLY A GRAPHIC REPRESENTATION AND IS NOT INTENDED TO BE SCALED FOR THE PURPOSE OF CONSTRUCTION, QUANTITY OR AREA. 2. ELECTRICAL TRADES CONTRACTOR IS RESPONSIBLE FOR MAINTAINING CIRCUIT INTEGRITY TO ALL EXISTING RECEPTACLES, TELEPHONE, DATA, CLOCKS, SPEAKERS, EQUIPMENT, ETC., THAT IS TO REMAIN. 3. REFER TO MECHANICAL AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS AND NOTES. 4. REPAIR/REPLACE ANY CONSTRUCTION DAMAGED DURING DEMOLITION (OR CONSTRUCTION) TO ITS ORIGINAL LEVEL OF FINISH OR QUALITY (AS ACCEPTABLE TO ARCHITECT/DESIGNER). 5. DISCONNECT AND REMOVE RECEPTACLES, TELEPHONE, DATA, CONDUIT AND BRANCH CIRCUITING IN WALLS THAT ARE TO BE DEMOLISHED. ABANDON CONDUIT IN FLOORS AND WALLS WHERE POSSIBLE CUT FLUSH AND CAP. PROVIDE BLANK COVER PLATES AS REQUIRED FOR UNUSED BOX OPENINGS. COVERING M/E/P DESIGN RTER OO e No. fir, f innnroia 07/18/19 en 'ill m c V mco ov � LL s Va L E c� m a TDGArchitects.COm Go Automotive O V N � a JZ O W a> 0 O 0 LLI •L7 Np Q W a) P: � - O d U) 2 CL ME:(D LLI 0:CD O Z U)m N M Q W 03 ED W (D oZ J Lou �I � (n E O W a= LU Lo o a 2 0 v U a N m ReWelon Schedule Data DeeaiPtlan 03/28/19 Final Review EAM Eegkaers, Inc Electrical and Mechanical Consulting Englreers 499 S.OIh Woodward Su1e199, Birmingham M148999 Phone N 528 7 Fm 24 28.1512 www.eam engine on wiyneers.cown Job No.: 423-18041 Drawn Bv. DB Checked Bv. RRT E z g, T J n T� n/ LU O T8 Eg H gE mq 3 J0^ p` LL n E. 8B Project Number 18=840w01 Drawing Number E 301