HomeMy WebLinkAboutM 100All I 1) 1 [11 1 1 :.. my, I kill �4 I. REMOVE EXISTING MECHANICAL SERVICES AND EQUIPMENT AS INDICATED AND/OR 1. SHOULD THERE BE ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS & SPECIFICATIONS DESCRIBED ALONG WITH SUPPORTS, HANGERS, CONTROLS, AND ALL RELATED THE GREATER QUANTITY OR OUAUTY WORK SHALL BE PERFORMED. THIS WORK MUST BE ACCESSORIES. SUBMITTED IN WRITING TO ENGINEER PRIOR TO FINAL BID FOR APPROVAL. NO EXTRAS SHALL BE ALLOWED AFTER THAT TIME. THIS SHALL ALSO PERTAIN TO ANY DISCREPANCIES IN THE CONTRACT 2. ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED TO BE EXISTING UNLESS DOCUMENTS OR BETWEEN TRADES. ALL ITEMS SHALL BE ADDRESSED IN WRITING PRIOR TO FINAL OTHERWISE NOTED. BIDS. 3. FIELD VERIFY EXACT SIZE AND LOCATION OF ALL EXISTING SERVICES PRIOR TO 2. CONTRACTORS ARE CAUTIONED NOT TO SUBMIT A BID WITHOUT CAREFULLY REVIEWING THE DEMOLITION. COMPLETE CONTRACT DOCUMENTS INCLUDING ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL TRADES, DRAWINGS, AND THE COMPLETE PROJECT MANUAL NO ADDITIONAL CHARGE 4. COORDINATE SHUTDOWN OF ANY EXISTING SYSTEMS WITH THE BUILDING SERVICES TO CONTRACT PRICE WILL BE ALLOWED FOR ADDITIONAL CONTRACTOR EXPENSE RESULTING FROM PERSONNEL A FAILURE TO COMPLY WITH THIS REQUIREMENT. 5. WHERE DUCT AND/OR PIPE INSULATION HAS BEEN DAMAGED, THE CONTRACTOR SHALL 3. NO MODIFICATIONS TO THE SPECIFICATIONS, CONSTRUCTION DOCUMENTS, OR INTENT OF THE REPAIR INSULATION AS REQUIRED TO MATCH EXISTING. SCOPE OF WORK SHALL BE ALLOWED WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE ENGINEER. ALL MODIFICATIONS, CHANGE ORDERS, ALTERNATES, VALUE ENGINEERING, OR ANY 6. ALL ITEMS REMOVED SHALL REMAIN THE PROPERTY OF THE OWNER UNLESS POSSESSION REVISIONS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND ENGINEER FOR REVIEW. RIGHTS ARE WAIVED. REFER TO SPECIFICATIONS. 4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING RELOCATED EQUIPMENT AND 7. UNITS OF DEMOLITION ARE INDICATED ON THE DRAWINGS. SHOULD EXISTING FIELD OWNER PROVIDED EQUIPMENT. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION CONDITIONS REQUIRE MODIFICATIONS OF THESE LIMITS FOR THE PROPER INSTALLATION OF ALL TRADES RESPONSIBLE FOR FINAL CONNECTION OF ALL EXISTING AND RELOCATED OF NEW WORK, THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH MODIFICATIONS. EQUIPMENT. 5. ALL WORK MUST COMPLY WITH THE REQUIREMENTS OF THE INDIANA MECHANICAL CODE, LOCAL B. ALL ITEMS INDICATED WITH CROSS -HATCHING SHALL BE REMOVED UNLESS OTHERWISE AMENDMENTS AND ORDINANCES. WHERE INSPECTORS ARE REQUIRED BY AUTHORITIES HAVING NOTED. CAP EXISTING PIPING, DUCTWORK, ETC. AT BRANCH MAINS. REMOVE ALL JURISDICTION, WORK MUST NOT BE CONCEALED UNTIL INSPECTIONS AND TESTING ARE COMPLETED RELATED CONTROLS, WIRING, ETC., UNLESS OTHERWISE NOTED. AND ACCEPTED. 6. COORDINATE PLACEMENT OF ALL MECHANICAL RELATED EQUIPMENT AND DEVICES WITH OTHER TRADES. DO NOT POSITION OR INSTALL ANY MECHANICAL EQUIPMENT OR DEVICES IN ANY SYSTEM IN SUCH A A WAY THAT IT WILL BE INACCESSIBLE OR UNMAINTAINABLE AFTER CONSTRUCTION IS COMPLETED. PROVIDE DUCT ACCESS DOORS AT FIRE DAMPERS, ETC. GENERAL HVAC NOTES: 7. REPLACE OR REPAIR ALL ARCHITECTURAL FEATURES REMOVED OR DAMAGED DURING THE COURSE OF THE WORK. REPAIR OR REPLACEMENT MUST, AS A MINIMUM, EQUAL ORIGINAL CONDITION. SPECIAL CARE MUST BE TAKEN ON THE ROOFS TO PREVENT DAMAGE. ANY DAMAGE MUST BE 1. COORDINATE NEW DUCTWORK WITH EXISTING SITE CONDITIONS. EQUIPMENT PROMPTLY REPAIRED AT NO EXPENSE TO THE OWNER. COMPLY WITH BONDING REQUIREMENTS OF MANUFACTURER AND ALL OTHER TRADES TO PREVENT INTERFERENCE. THE ROOFING MANUFACTURER. 8. SEAL ALL ROOF AND WALL PENETRATIONS. FLASH AND COUNTER -FLASH ALL ROOF PENETRATIONS. 2. PROVIDE ACCESS AROUND ALL NEW EQUIPMENT PER MANUFACTURERS MINIMUM ACCEPTABLE HEIGHT OF FLASHING IS TWELVE (12) INCHES ABOVE ROOF. RECOMMENDATIONS. 9. MAINTAIN A MINIMUM OF 10'-0' BETWEEN ALL FRESH AIR INTAKES AND PLUMBING VENTS, EXHAUST FAN DISCHARGE, FLUES, ETC. COORDINATE WITH ALL OTHER CONTRACTORS ON SITE. 3. ALL CORING THROUGH FLOORS SHALL BE BY MECHANICAL CONTRACTOR. 10. BALANCE MECHANICAL SYSTEMS TO PROVIDE INDICATED FLOWS. SEE SPECIFICATIONS FOR OTHER TEST AND BALANCE REQUIREMENTS. SUBMIT FINAL BALANCE REPORT OF MECHANICAL SYSTEMS FOR 4. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS POSSIBLE, UNLESS OTHERWISE NOTED. REVIEW. COORDINATE ROUTING WITH OTHER TRADES TO PREVENT INTERFERENCE. 5. BALANCE AIR SYSTEMS TO INDICATED FLOW RATES. 6. DUCT SIZES TO DIFFUSERS SHALL MATCH NECK SIZE OF EACH. GENERAL PLUMBING NOTES' 7. ALL CONCEALED SUPPLY AIR DUCTWORK SHALL BE INSULATED PER SPECIFICATIONS. I. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL PLUMBING FIXTURES. 8. ALL DUCTWORK SHALL BE CONCEALED IN WALLS AND/OR CEILING SPACE. 2. COORDINATE ALL LOCATION, SIZE, AND ELEVATIONS OF ALL SLEEVES THROUGH WALLS AND 9. SEAL ALL PENETRATIONS THROUGH WALLS PER SPECIFICATIONS. SLABS WITH STRUCTURAL AND ARCHITECTURAL DRAWINGS. 10. COORDINATE EXACT LOCATIONS OF DIFFUSERS AND RETURN GRILLES WITH 3. ALL OUTLETS FOR FUTURE CONNECTIONS SHALL BE VALVED, CAPPED, AND INSTALLED TO PERMIT ARCHITECTURAL AND ELECTRICAL REFLECTED CEILING PLAN. EASY CONNECTION. COORDINATE LOCATION WITH STRUCTURAL AND ARCH. CONDITIONS. 11. COORDINATE T-STAT LOCATIONS WITH ARCHITECT. 4. VERIFY DEPTHS, SIZES, AND LOCATIONS OF EXISTING UTILITIES IN THE FIELD. INCLUDING POINTS OF CONNECTION BEFORE STARTING WORK. 12. PROVIDE SPIN -IN DAMPERS AT ALL ROUND BRANCH DUCT CONNECTIONS TO DIFFUSERS. PROVIDE MANUAL VOLUME DAMPERS AT EACH BRANCH DUCT AT CONNECTION TO MAIN 5. FAUCETS AND PLUMBING FIXTURES SHALL BE OF WATER CONSERVATION TYPE AND COMPLY WITH AS WELL AS IN EACH DUCT AFTER A BRANCH DUCT SPOT. THE STATE ENERGY STANDARDS. 6. RUN ALL SANITARY PIPING AT 1/8' PER FOOT, MINIMUM SLOPE, UNLESS OTHERWISE NOTED. 1-1/2' TO 2-1/2' PIPES SHALL PITCH AT 1/4' PER FOOT. 7. COORDINATE INTERRUPTIONS OF SERVICES INCLUDING WATER, SEWER, AND NATURAL GAS WITH OWNER AND UTILITY COMPANIES A MINIMUM OF 72 HOURS IN ADVANCE OF ALTERATIONS. 8. REFER TO ARCH. DRAWINGS FOR PHASING LIMITATIONS ON SEQUENCE OF CONSTRUCTION. 9. CONTRACTOR SHALL MAINTAIN ADEQUATE CLEARANCES ABOVE AND AROUND ELECTRICAL PANELS, EQUIPMENT, AND TRANSFORMERS WHEN ROUTING OVERHEAD DOMESTIC WATER, SANITARY, OR STORM PIPING. 10. OVERFLOW RAIN CONDUCTORS SHALL BE ROUTED TO EXTERIOR WALL AND SPILLED TO GRADE. 11. REFER TO PLUMBING FIXTURE SCHEDULE FOR FIXTURE TYPES, CONNECTIONS, AND ADDITIONAL REQUIREMENTS. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH STATE OF INDIANA AND COUNTY DEPARTMENT OF HEALTH CROSS CONTAMINATION CODE REQUIREMENTS. 13. PROVIDE ONE OF THE FOLLOWING METHODS FOR ALL FLOOR DRAINS, FLOOR SINKS WHERE TRAP IS SUBJECT TO EVAPORATION LOSS. A.PROVIDE TRAP SEAL DEVICE EQUAL TO RECTORSEAL SURSEAL-PLUS OR J.R. SMITH 2692 QUAD CLOSE, CONFIRM ACCEPTANCE OF THIS METHOD WITH LOCAL PLUMBING AUTHORITY. 14. PROVIDE CLEANOUTS AT THE BASE OF ALL STACKS. 15. ALL VENTS THROUGH THE ROOF MUST BE A MINIMUM OF 10'-0' FROM OUTDOOR AIR INTAKES AND 12' ABOVE THE ROOF. 16. JOINTS, FLANGES, UNIONS OR VALVES OF ANY KIND SHALL NOT BE INSTALLED IN THE NATURAL GAS PIPING LOCATED ABOVE CEILING IN A RETURN AIR PLENUM. 17. AT EACH CONNECTION OF GAS SUPPLY TO EQUIPMENT, PROVIDE A PIPE UNION, GAS SERVICE COCK, TEE, AND 12' LONG DIRT LEG WITH CAP. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/27/19 MECHANICAL LEGEND AIR BALANCING DAMPER CIRCUIT SETTER HVAC HEATING VENTILATING & AIR CONDITIONING BFP BACKFLOW PREVENTER (BFP) z 0 RETURN GRILLE HW HOT WATER GM GAS METER ® SUPPLY DIFFUSER Hi HOT WATER RETURN WM WATER METER ® EXHAUST GRILLE I.E. INVERT ELEVATION -❑ FLOW SWITCH (FS) REDUCER IW INDIRECT WASTE 50 NEW CONNECTION TO EXISTING SPIN -IN FITTING WITH VOLUME DAMPER LAV LAVATORY 0 DEMOLITION LIMITS PENETRATION RADIATION DAMPER MS MOP SINK Q) DIAMETER HORIZONTAL DUCT FIRE DAMPER O.A. OUTSIDE AIR tt PLUG VALVE NON LUBRICATED TYPE (KEYPORT 400 SERIES) (GAS COCK) VERTICAL DUCT FIRE DAMPER R.A. RETURN AIR d BALL VALVE AC AIR CONDITIONING UNIT RG/EG RETURN GRILLE OR EXHAUST GRILLE D4 GATE VALVE ACCU AIR COOLED CONDENSING UNIT RTU ROOFTOP UNIT b N CHECK VALVE A.F.F. ABOVE FINISHED FLOOR S.A. SUPPLY AIR O.S. & Y VALVE AGF AIR GAP FITTING SAN SANITARY ,&I RELIEF VALVE ASR AUTO SPRINKLER RISER S SINK 4 THERMOMETER CO CEILING DIFFUSER WC SUPPLY REGISTER (2) THERMOSTAT (ELECTRIC) CFH CUBIC FEET PER HOUR - - - DOMESTIC COLD WATER RECIRCULATING PUMP CFM CUBIC FEET PER MINUTE ---- DOMESTIC HOT WATER MANUAL AIR VENT CO CLEANOUT ----- DOMESTIC HOT WATER RETURN SHOCK ABSORBER CW COLD WATER (DOMESTIC) W WASTE ® BALANCING VALVE CU CONDENSING UNIT SR WATER CLOSET GAUGE ON DOWN SS SERVICE SINK III UNION DR DRAIN LINE UR URINAL C PIPE DOWN DWH DOMESTIC WATER HEATER V.T.R. VENT THRU ROOF PIPE UP (E) EXISTING -FP- FIRE PROTECTION ,J PIPE TEE EF EXHAUST FAN -G- NATURAL GAS -4ilH STRAINER EWC ELECTRIC WATER COOLER -SA SANITARY SEWER I] FLOOR DRAIN EWH ELECTRIC WATER HEATER -ST STORM SEWER PIPE GUIDES FD FLOOR DRAIN VENT PIPING - MECHANICAL DRAWING INDEX SHEET NO. SHEET TITLE M 100 MECHANICAL COVER SHEET M 101 OVERALL FLOOR PUN M 201 FLOOR PLAN - PLUMBING M 301 FLOOR PLAN - HVAC M 401 MECHANICAL DETAILS & SCHEDULES M 501 MECHANICAL SPECIFICATIONS COVERING M/E/P DESIGN �G��O RTER OO! No. f innnrola 07/18/19 `e e� LL s Vo L Q u 'co NN n my G) ry ma TDGArchitects.com Automotive O V N Y9 v a J Z D p E W 0U W'a0 ...; i p C00 r) Q W F_ O a U) 2MC Q� (D W = � O Z U) O _ Q W 03 W GO .1 WI !n E WoOW LO O = t] V U d N m ReVlelon Schedule Date Dasaiptlan 03/28/19 Finch Review EAM Engineers, Inc Eledncal and Mechanical Con601An9 En911BBm 400 S.OItl Woodward Site 100, Birmingham MI 48009 Phone 24 528 7 Fax 24 28.1542 www.eam engine entneeirl Job No.: 423-18041 I- J ILIJ Q LJJ io U = .< Z Cs Q ry 2 LL, �s U ># Eg L L1 0 R Project Number 18-840.01 Drawing Number M 100