Loading...
HomeMy WebLinkAboutM 401SPLIT SYSTEM HEAT PUMP SCHEDULE MAKE CONDENSING UNIT SAMSUNG MODEL NO. OEM INDOOR UNIT CONDENSING UNIT ELECTRICAL NOTES COOLING HEATING COOLING HEATING TBTU/HR. BTU/HR. TBTU/HR. BTU/HR. INDOOR UNIT OUTDOOR UNIT INDOOR OUTDOOR VOLT I AM A VOLT MCA MFS HP-1 CU-1 AUUIBRIF AOUIBRLFC 618 18,000 21,600 18,000 21,600 208-230/60/1 54 W 208-230/60/I 17.3 20 1-10 NOTES/ ACCESSORIES: 1. WIRED WALL MOUNTED CONTROL UTY—RNRUZ2 2. WIND BAFFLES. 3. SEE SPECIFICATION. 4. R-410A REFRIGERANT PIPE PER MANUFACTURER REQUIREMENTS. 5. HSPF: 10.9. SEER 21.4, EER 13.4. 6. PROVIDE CONDENSATE DRAIN PAN OVERFLOW SENSOR AND WIRE TO SHUT DOWN UNIT ON OVER FLOW CONDITION. 7. PROVIDE HEAT CAPABILITY DOWN TO —5'F OUTSIDE AIR TEMPERATURE. 8. MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONTROL WIRING TO AND FROM UNITS. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL POWER WIRING TO AND FROM UNITS. MECHANICAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL TRADES. 9. PROVIDE 24' PRE—FAB PATE EQUIPMENT BASE 10. APPROVED EQUAL- MITSUBISHI. RECTANGULAR S.A. DUCT SPIN —IN FITTING MAXIMUM OF 4 FT. LONG INSULATED FLEXIBLE DUCTWORK WITH Did 45' HARD DUCT DIFFUSER BEND HARD DUCT it i LONG RADIUS ELBOW HARD DUCT VOLUME DAMPER WITH ACCESS VIA LIKING OUT DIFFUSER HARD DUCT ELBOW WITH VERTICAL FLEX DUCT CONNECTION TO DIFFUSER FLEXIBLE DUCT CONNECTION DETAIL (ABOVE GYPSUM BOARD CEILINGS) NO SCALE RECTANGULAR S.A. DUCT SPIN -IN FITTING _ W/ VOLUME DAMPER HARD DUCT � DIFFUSER HARD DUCT LONG J RADIUS ELBOW MAXIMUM OF 4 FT. LONG INSULATED FLEXIBLE DUCTWORK WITH MAXIMUM 45' BEND , HARD DUCT ELBOW WITH VERTICAL FLEX DUCT RELEASED FOR CONSTRUCTION CONNECTION TO DIFFUSER Subject to compliance with all regulations E DUCT CONNECTION DETAIL of State and Local Codes City OF Camel ((�� �vm�llaYu3NaA2+L DATE: \ 08/27/19 VE LAY -IN CEILINGS ONLY) NO SCALE EXHAUST FAN SCHEDULE TAG AREA MANUFACTURER AND DRIVE C.F.M. E.S.P. SPEED MOTOR ACTIVATION NOTES/ACCESSORIES SERVED MODEL NUMBER TYPE R.P.M. HP (WATTS) VOLT EF-1 SEE PLANS GREENHECK DIRECT 400 0.625 969 1/4 120 1 CONTINUOUS A — D SO-99—VG NOTES/ACCESSORIES: A. MOTORIZED BACKDRAFT DAMPER, DAMPER ACTUATOR, 115 VAC ACTUATED, END SWITCH B. DISCONNECT C. VARIABLE SPEED CONTROL MOUNTED IN FAN FOR BALANCING, MOUNTED ON EXTERIOR OF FAN D. JUNCTION BOX MOUNTED AND WIRED E. PROVIDE LISTED CONTROL METHOD. COORDINATE WITH ELECTRICAL TRADES. PUMP SCHEDULE TAG MANUFACTURER & MODEL NO. GPM HEAD SIZE MOTOR VOLTAGE REMARKS III B & G PL-30 1 22 3/1 1/12 120/l/60 A, B A. BRONZE BODY CONSTRUCTION SUITABLE FOR POTABLE WATER, NON FERROUS IMPELLER, MAINTENANCE FREE PERMANENTLY LUBRICATED BEARINGS. B. COMBINATION AQUASTAT/TIMECLOCK. SET TIMECLOCK FOR UNOCCUPIED HOURS. RECTANGULAR SUPPLY AIR DUCT SPIN —IN FITTING J" WITH VOLUME DAMPER DRAW BAND FLEX DUCT — MAX. 4 FT. LENGTH DIFFUSER � DRAW BAND HOUSING GRILLE J NOTE: THE USE OF FLEXIBLE AIR DUCT IS TO SIMPLIFY THE INSTALLATION OF THE BRANCH DUCT TO DIFFUSER CONNECTION. ELEVATION OF DIFFUSER CONNECTION NO SCALE CEILING HARD LONG RADIUS I PLUMBING FIXTURE SCHEDULE PIPE CONNECTION SIZES TAG ITEM MAKE MODEL MODEL NOTES/ACCESSORIES NAME NUMBER W V CW HW EWC-1 COOLER (ADA) OASIS PGBACSL 1-1/2' 1-1/2' 1/2' — D. R V RSACOOLER FD-1 FLOOR DRAINLAV-1 MIFAB — F1100 PLANS SEE -— A. B. 0, NN, 00 LAVATORY MANSFIELD MAVERICK II 267 1-1/2' 1-1/2' 1/2' 1/2' A, B. D. E. K. R. (COUNTERTOP) S. BB, DO MS-1 MOP FIAT — B2 3' — 1/2' 1/2' A, B, 0, P, GO, 00, PP SINK (MOLL STONE) UR-1 URINAL (ADA) MANSFIELD CASCADE 410UHE 2' 1-1/2' 3/4" — A, B, J, BB WC-1 WATER CLOSET (WALL MID, ADA) MANSFIELD ERIE 1301 4' 2' I" — A. B, C, I, BB TD-1 POLYMER MIFAB — T2000 4' KK TRENCH DRAIN CB-1 CATCH BASIN MIFAB — CB-1224 SE PLANS — — A, B. Q, NN, 00. JJ PLUMBING FIXTURE NOTES/ACCESSORIES PROVIDE ALL SLEEVES, TEMPLATES, ETC. AS PROVIDE SEAT: A VERIFY COLOR/FINISH WITH ARCHITECT B REQUIRED FOR ROUGH —IN OF FIXTURES. C W STA—TITE FASTENERS COORDINATE WITH ARCHITECTURAL TRADES. BEMIS: 195555TFR / D PROVIDE BRASSCRAFT COMMERCIAL I FLUSH VALVE: MANUAL OPERATION J FLUSH VALVE: MANUAL OPERATION ANGLE SUPPLY WITH RISER DELTA: 81T201 DELTA: BIT231 K LAVATORY FAUCET: 0 HOSE AND HOSE BRACKET: P MOP HANGER: DELTA: 22C101 DELTA: ZBT911 DELTA: 28T910 Q PROVIDE J.R. SMITH 2692 TRAP SEALER R PROVIDE BRASSCRAFT 'P" S PROVIDE BRASSCRAFT SIZED TO MATCH DRAINING OUTLET 1-1/4' CAST BRASS TRAP 1-1/4" OFFSET DRAIN WITH TAILPIECE BE PROVIDE CHAIR CARRIER W/ FOOT 00 TEMPERING VALVE: EE MIXING VALVE: SUPPORTS, MOUNT PER ADA REQUIREMENTS POWERS: LF9480, ASSE 1070 CASH ACME: 820 FF MIXING VALVE: GO VINYL BUMPERGUARD: NN USE F1100C WHERE MEMBRANE FLOOR IS USED HAWS: 9202E FIAT: E-77—AA (2 REQUIRED) 00 PROVIDE DEEP SEAL TRAP PP DELTA FAUCET WITH VACUUM BREAKER: END OUTLET, STRAINER, HEEL PROOF UNLESS OTHERWISE NOTED 28C2384 UU GRATE, OVERALL WIDTH 12' JJ 12' X 20' X 24" DEEP POLYETHYLENE CATCH KK 12' WIDE (4' THROAT) TRENCH DRAIN WITH BASIN WITH REINFORCED CLASS C STAINLESS CLASS C SLOTTED, H-20 GRATE, WITH STEEL SLATTED, H-20 RATED GRATE, SEDIMENT LOCKDOWNS AND HEAVY—DUTY FRAME BASKET AND HEAVY—DUTY FRAME ASSEMBLY ASSEMBLY WITH ANCHOR STUDS WITH ANCHOR STUDS RECTANGULAR SUPPLY AIR DUCT SPIN —IN FITTING WITH VOLUME DAMPER 1 Ir DOMESTIC WATER HEATER SCHEDULE (ELECTRIC) CAPACITIES ELECTRICAL DATA ELECTRICAL iAC SYSTEM SERVED LOCATION MANUFACTURER AND NOTES/ACCESSORIES RECOVERY M. STO TEMP. MODEL NUMBER (GPM) (GAL) RISE W TYPE VMT AMPS Ell OOMESIIC HOT SEE PUN LOCHINVAR JRCO20M 19 M 100'F 1 2500 ELECTRIC MM/l/90 - I-5 WATER THROUGH 00 NOTES• 1. INTEGRAL HEAT TRAP. CHECK HOT WATER RECIRC PUMP 2. TEMPERATURE & PRESSURE RELIEF VALVE. y,LLyE 3. BRASS DRAIN VALVE. (TYp) BALANCE VALVE 4. 6 YEAR LIMITED TANK & PARTS WARRANTY. 5. THERMAL EXPANSION TANK EQUAL TO WILKINS XT-35 ---q HWR NOT'''E: HE CI,,R[[[C. PUMP r-�---��—�--(CW INLET HW TO FIXTURES BALL VALVE �- (TYP) r T&P 71 DIELECTRIC UNION (TYP)�l T f RELIEF VALVE EXPANSION TANKN :r_ 77 71— _< LL s Va L Q I� u wa o - n Cm mGO () ry m ra TDGArchitects.com Ipm=r] Automotive O V N CO � a J Z � 0 E W C) U LU 'a O ...; i p Cr) Q Lu p: 0 °o O a.0 Q2 (D GO W X:� O 0) zIC5 D2 Q W @ W F_ ED o� JLU�I�ln 0O W� WLLO o a 2 OvU acNJlm ReWaim Schedule Date Desaiptlan 03/28/19 Final Review HARD J V �1 ELECTRIC DUCT WATER HEATER DRAW BAND EAM Engineers, Inc. FLEX DUCT — MAX. Electrical and Mechanical CensoMng Engineers 4 FT. LENGTH THERMOSTAT DRAIN VALVE 400 N. Om Woodward, Note 100, Birmingham MI 48009 WITH HOSE END PdoneA .528 T�Fx24�ze.154z DIFFUSER DRAW BAND www.eam engine neyneers.cwn HOUSING CEILING WALL MOUNTING Job No.: 423-18041 SHELF FULL SIZE RELIEF PIPE, DOWN ON DRAIN PAN WALL TO SPILL IN MOP SINK. GRILLE NOTE: TERMINATE WITH AIR GAP Drawn By MC THE USE OF FLEXIBLE AIR DUCT IS TO SIMPLIFY THE INSTALLATION OF THE Checked Bv. GRS BRANCH DUCT TO DIFFUSER CONNECTION. ELEVATION OF DIFFUSER CONNECTION NO SCALE VOLUME DAMPER AT END OF RUN ,A" OR AT LAST DIFFUSER MAIN DUCT (SEE FLOOR VOLUME DAMPER (SIZE AS INDICATED 15' TRANSITION TO PLAN FOR SIZE) AT END OR AT LAST OF RUN GRILLE ON BOOR PUNS) DEPTH OF DOWNSTREAM DUCT (EY DIRECTION OF AIR FLOW AIR FLOW II 1.5 x 'D' II BRANCH SUPPLY TAKE —OFF TO BE SAME DEPTH AS MAIN DUCTr8RANCH DIUS 15' TYPICALI TRANS TO OCCUR (SEE FLOOR PLANS FOR SIZE)DIUS '2B' MAIN DUCT "A" SPLAY IN DIRECTION OF PRIOR TO DUCT CONNECTION (SIZE AS INDICATED AIR FLOW. MAINTAIN DEPTH ON FLOOR PLANS) OF BRANCH DUCT b' 15' TRANSITION — _ = WHERE REQUIRED _ VOLUME DAMPER WITH 9 'D' VOLUME DAMPER WITH< UCT 'B' LOCKING QUADRANT (TYP) rcl (SIZE AS INDICATED LOCKING QUAD(TYP) ON FLOOR PLAN) ONFLOORINDICATED BRANCH DUCT TYPICAL RETURN OR EXHAUST DUCT CONNECTION DETAIL NO SCALE TYPICAL RADIUS TURN ON SUPPLY AIR DUCT DETAIL NO SCALE ELECTRIC WATER HEATER(DWH-2) DETAIL NO SCALE COVERING M/E/P DESIGN �G���O RTER OO! No. f innnroiJl 07/18/19 I J Q vC,6lu 5" z J �s 53 J Q € q = O Q L UH2 m c LU LLI v m� CC p` 0� Project Number 18=840a01 Drawing Number M 401