Loading...
HomeMy WebLinkAbout19080110 ApplicationstI" u` CITY OF CARMEL TEMPORARY USE APPLICATION e01�M' PERMIT # 19 M 5 0 i 10 APPLICANT NAME PHONE FAX A CLASSIC PARTY RENTAL 317.251.7368 STREET ADDRESS CITY STATE ZIP 8020 ZIONSVILLE ROAD INDIANAPOLIS INDIANA 46268 E-MAIL ADDRESS BEST METHOD OF CONTACT MIKE@ACLASSICPARTYRENTAL.COM CELL PROPERTY NAME PHONE FAX OWNER PREMIER FAMILY CHIROPRATIC 317.844.7000 STREET ADDRESS CITY STATE ZIP 120 EAST CARMEL DRIVE CARMEL INDIANA 46032 LOCATION LOT NUMBER SUBDMSION BUILDER OF RECORD OF PROJECT STREET ADDRESS Cm STATE ZIP 120 EAST CARMEL DRIVE CARMEL INDIANA 46032 HAMILTON COUNTY PARCEL NUMBER ZONING NAME OF BUSINESS TYPE OF 0 SPECIAL EVENT ❑ OUTDOOR SALES ❑ SEASONAL SALES ❑ MODEL HOME/SALES (BUILDING PERMIT # ) USE ❑ CONSTRUCTION FACILITY ❑ FIREWORKS SALES ❑ TEMPORARY CLASSROOM 0 FOOD STAND DETAILS OF DATES OF PROPOSED USE HOURS OF OPERATION USE FROM: 8.29.19 TO: 8.29.19 6-9PM WILL A TEMPORARY STRUCTURE BE REQUIRED? O YES ❑ NO IF YES, SIZE OF STRUCTURE: 20'X 80' FRAME TENT MOBILE UNIT CERTIFICATE #: WILL ASIGN BE REQUIRED? ❑ YES ❑ NO SIGN REVIEWED/RELEASED *** THE FOLLOWING SECTION IS ONLY APPLICABLE TO FIREWORKS SALES *** FIREWORKS WILL THE STRUCTURE BE USED FOR MORE THAN 500 LBS OF FIREWORKS? ❑ YES ❑ NO SALES DOES THE STRUCTURE ALREADY HAVE A SPRINKLER SYSTEM INSTALLED7 ❑ YES ❑ NO HAS THE STRUCTURE PREVIOUSLY BEEN USED FOR THE SALE OF FIREWORKS? ❑ YES ❑ NO *** THE FOLLOWING SECTION IS ONLY APPLICABLE TO FOOD STANDS *** FOOD PLEASE LIST ADDRESSES FOR UP TO 3 SALES AREAS STANDS 1• z. 3. CERTIFICATION AND NOTICE OF INTENT TO COMPLY I HEREBY CERTIFY THAT I HAVE THE AUTHORITY TO MAKE THE FOREGOING APPLICATION, THAT THE PLANS FILED WITH THE APPLICATION ARE CORRECT, AND THAT THE OPERATION AND CONDUCT OF THE TEMPORARY USE WILL CONFORM TO THE REGULATIONS OF THE CARMEL UNIFIED DEVELOPMENT ORDINANCE. FAILURE TO COMPLY WITH THE TERMS AND CONDITIONS OF THIS PERMIT MAY RESULT INA CITATION AND ADDITIONAL FEES. j. Miclu+ wl� ,tqu,tk MIKE WIGGINS 8.19.19 Sigmture of Owner or Authorized Agent Printed Name Data REQUIRED BASE INSPECTIONS * * Additional inspections may be required. ❑ Fire ❑ Final/ Site V Reviewed / R — Department o /mnity Services D c Valid Until: PERMIT FEES Temporary Use Fee Base Inspections Cert. of Occupancy I $O, oo TOTAL I D ad Pee Received— Department of Community Services Date ,1111 1 ' III illilill Milli=111IMU fl u r =00 0 9mm mlvrd r U i w 0 N g 1 r Assembly Instructions 11 24' through 30' Wide Systems With Expandable Kits SALES OFFICES: 1100 BURCH DRIVE PO BOX 3477 EVANSVILLE, IN 47733 USA n .a - PHONE: 812-867-2421 FAX: 812-867-0547 1-800-544-4445 EMAIL: tents@anchorinc.com www.anchorinc.com PRODUCTION FACILITIES: BRADENTON,FL EVANSVILLE, IN EC 3190 F12430 0706 R1 09-11 t qV 24' through 30' Wide Systems With Expandable Kits SALES OFFICES: 1100 BURCH DRIVE PO BOX 3477 EVANSVILLE, IN 47733 USA n .a - PHONE: 812-867-2421 FAX: 812-867-0547 1-800-544-4445 EMAIL: tents@anchorinc.com www.anchorinc.com PRODUCTION FACILITIES: BRADENTON,FL EVANSVILLE, IN EC 3190 F12430 0706 R1 09-11 o1v a v �v en • • wv OQO-p v � • •- r" ' of +�� . . �`p o i o ins a i w O ' w 0 , rrw�rw�wrr�rrrr�— o.rrr�rrrirrr�r. , PARTS LIST CHECKED REQUIRED I PTT 4 PTC 4 PTI 4-2pa 4` 4 4 4 4 8 16 8 16 1 1 i 30" tipbl:L -gyp 10" NAIL STAKE STORAGE BAG FOR TOP INSTALLATION SHEET STAKE WRENCH FOP PTC added stabiiity, INSPECT SITE Prior to actual frame assembly be 6 GUY WEBS sure to look up, down, above &below INTERMEDIATE RAFTER for obstacles, pipes, wires, trouble, B etc. CHECKED BY: DATE: (2) PAMRS HAVE AN ADDI1110NAL RTE&3 ATTACHED 2 �1Y�7UT & CHECK Utilize parts list for a quick LD. and to ensure that you have all the parts. SAVE ASSEMBLY* Begin by placing PTI casting over Female Eave Bar. Then join Male Eave Bar with long pin from PTI through bars only. Do not pin through PTI. Nut holding PTEB must be on top of bar. Insert complete eaves into PTC casting and hand tighten PTC nut. Use Fiesta wrench for a+la to Yz additional turn, Do not over tighten. PTI EB;; i mu "��►� . s . 27 HIP & PEAK Join male and female ends of two-piece Hip and secure with pin. Insert Hip Bar into PTC Corner Casting. Fasten with short pin. Insert opposite end into PTT Peak Casting and fasten with pin. A second installer should support the PTT while hips are being attached. 0 RAFTERS & BRACES* Insert Raker Bar into PTI Casting; fasten with short pin. Insert opposite end into PTT Casting and fasten with pin. Connect Hip Brace to PTEB-3's on Hip and Rafter using pins attached. Connect Intermediate Rafter to PTEB-3's on Hip and Eave using pins attached. *For 10'-0" starter kit and extension parts and instructions, see pages 5 & 6.. hip female �F�TEB PTI PTC _��A!- t male lim hip w/PTEB-3 W rafter w/PTEB-3 3 4 PUT TOP ON Spread drop cloths. Lay out two piece top with lace edges together and top side up. Matching centerlines, push first loop up through corresponding grommet. Continue lacing process and cover lacing with protec- tive flap and snap to rings, Tie off last long lacing loop. Repeat steps on opposite side starting with second loop from ridge. Place top over frame, Fasten a Fiestab buckle at each side of comers and at center of each side (more if required) to keep top from blowing off. LiFT ONE SIDE Lift one side of frame, insert both Corner Uprights into PTC Corner Castings and fasten with long pin. Then Insert Intermediate Upnght Into PTI Casting and fasten with long pin. CAUTION, Braces at both corners and inter- mediate upright"MUST" be in position before lifting other side. hip female PTEB ea fe a male save PTC upright brace _, upright ® LIFT OTHER SIDE Lift other side of frame, insert both Corner Uprights into PTC Corner Castings phd fasten with long, pin, Then Insert intermediate Upright into PTI Casting and fasten with long pin. CAUTION: Braces at both corners and intermediate upright "MUST" be in position before lifting other side. Fr arning: o no rao a ric tent top ross hard or rough surfaces as abrasion m tent hardware is possible. 70 F Put strap behind save bar and up through buckle, SECURE TOP TO FRAME Starting at center of opposite sides, fasten Fiesta buckles to frame, wrap web strap around save bar and wail rope, then tension with buckle. TAKE DOWN �8 WEBS & STAKES Position tent as desired. (if uprights adjustable, raise to proper height.) Attach guy web and stakes as shown. Periodically check to make sure all are secure and taut. Protective covers are recommended for all stakes. "See caution on back page." IMPORTANT. Guy webs must be in place at all times. 1. Release straps and buckles. 2. Remove Intermediate uprights on three sides. Leave installed on side to be taken down last. 3. "Loosen" all guy webs. 4. Starting on one side — remove all braces. CAUTION: Do not remove braces from opposite side until first side is lowered to ground, 5. Remove (2) corner uprights and lower one side to ground, 6. Repeat assembly steps #146 in reverse for disassembly. MANPOWER REQUIRED: Three experienced installers should be able to assemble in less than one and one-half hours. TOOLS REQUIRED: Sledge Hammer Fiesta Wrench (supplied) eye bolt in PTC a' -o" corner upright ,(2) 10" nails in each base plate. Hammer down flush with base plate to secure. SUPPLEMENTAL INSTRUCTIONS TO EXTEND LENGTH BY 10'0" 10' STARTER KIT r� 3 or, PTEB•3 g ' ��y {��A[�_CROSSBT ARRANGE FARTS \ f j SUPPORT L FOR ASSEMBLY JSTORAGEBAG I n WITH TOP Ab8i INTER- MEDIATE UPRIGHTS STAKES r-� a GUY WEBS 'r NAILS FOR UPRIGHT BASE PLATES PARTS LIST CHECKED RECUIRW 1 2 2 2 z 2 1 2 2 4 2 4 2 1 10'•0" 2 PC SUPE RAFTERPTI 10'•0" EAVE T U*rvu; BRACEE =7 10' STARTER FRAME MEMBERS ARE NOT SHADED, FOR ADDITIONAL EXTENSIONS, SEE NEXT PAGE, PTr PTI W I EYE BOLT To] UPRIGHT BRACE 30`STEELSTAKE Via.. WNAILSTAKE GUY WEBS INSTRUCTION SHEET 378 RIDGE & CROSS BARS Connect 2 -pc ridge and pin to PTTs using the PTRE pointed downward so that the ridge is elevated. Pin cross bars together and attach to frame as shown. MANPOWER REQUIRED Four experienced installers should be able to assemble in less than two hours. PTRE PTEB•3 PTT 2 PC RIDGE CROSSBAR SUPPORT PTT•PTI �`�`4.... RAFTER EPPCCC CROSSBAR PTN PTES-3 SUPPLE 110' EXTENSION KIT ARRANGE PARTS FOR ASSEMBLY =IRIA STAKES INTER - GUY WEBS MEDIATE UPRIGHTS NAILS FOR UPRIGHT BASE PLATES PARTS LIST CHECKEC REQUIRED PTN i PTR 2 PTI W i CYE BOLT 2 PfRTIM MWXTKM IP EAVE WIl PT€&9 t ItlCWWE 2 I �NfFl4Up1YAi1/WTF& 1 � CR0490Aq i{��- --�� UPRIGHT BRACE 2 D=� SC•STEELSTAKE 4 l 10'NAILSTAKE 2 GUY WEBS 1 INSTRUCTION SHEET JCTIONS TO EXTEND LENGTH BY 14'0" M BAR PTEB3 UPPOR 0 11 10,.0" RIDGE �, PTR u PTN PTR -PTI RAFTER p PC CROSS BAR ��' ��'77 PTI UPRIGHT w EAV 1D' EXTENSION FRAME MEMBERS ARE NOT SHADED. FOR ADDITIONAL EXTENSIONS, REPEAT FRAME PATTERN. LENGTH OF EXTENDED FRAME IS 10' EXTENSION NOT TO EXCEED TWICE THE WIDTH. 3,a RIDGE & CROSS BAR Slide PTR on to 10'-0" ridge. Align with hole at center of ridge and pin. Repeat for each 10'-0" ridge. Pin 10'-0" ridges together and add existing ridges to each end. Lift and pin assembled ridges to PTT's, using the PTRE pointed downward so that ridges are elevated. Insert PTR -PTI rafters into PTRs and PTIs and pin. Pin Cross Bars together and attach to frame as shown. MANPOWER REQUIRED Five Installers and two and one half hours assembly time for a 30'x 50' unit. rA NCHOR o INDUSTRIES INC. EVANSVILLE, INDIANA PHONE NUMBER 812.867.2421 FAX NUMBER 812.867.0547 Anchor products are of superior design and operate best within the parameters of these instructions. It is imperative that the instructions be carefully read and COMPLETELY FOLLOWED. Please read installation instructions before the installation or removal of this product. Installation instructions are available online at www.anchorinc.com or by calling 1-800-544-4445. CAUTION: 1. For each installation, the installer is solely responsible for evaluating the site and the proper securing method determined. Some soils require different staking or securing than that provided with the tent. Due to this variety of soil conditions, these are the manufacturer's suggested sequence of installation procedures. Anchor's responsibility is limited to the manufacture of the tent parts and materials. We are not responsible for methods that installers may choose to erect and secure the tent to the ground. 2. The number of stakes suggested in the installation instructions do not necessarily meet all or any relevant codes on the site of the tent installation. The number of stakes suggested will, in many cases, keep the tent erected, however, due to various soil conditions; these stakes will be insufficient to keep the tent secure in high winds. It is the tent installer's responsibility, not the manufacturer, to determine the appropriate number of stakes to meet the necessary wind loads on the site. Regardless of the number of stakes we suggest, we make no representation or warranty as to whether this specific number of stakes will meet the local tent code. Anchor does not, nor can it make any suggestions, representation, or warranties about the adequate staking required at each specific installation site. Staking information provided in the installation instructions is not a suggestion about what is necessary to meet a site-specific load. For additional important information, consult: "The IFAI Procedural Handbook For the Safe Installation and Maintenance of Tentage" and the IFAI Pocket Guide "Pullout Capacity of Tent Stakes", both available from the IFAI Tent Rental Division or on our website. 3. Inasmuch as the weather is unpredictable, good judgment and common sense must be incorporated within installation guidelines. It is the responsibility of the tent installer/maintainer to determine the severity of the weather, proper time and method of installation and/or erection and disassembly. Note: We recommend that snow and ice be removed from the tent surface as soon as possible because accumulation will damage the tent or fabric structure. Please consult with our Engineering Department about the maximum loads for each product. This product has been manufactured for use as a temporary structure. For the safety of all occupants, evacuation is recommended if threatening weather occurs, or if there is any doubt concerning the safe use of this product. 4. Proper safety equipment should be used at all times to insure a safe installation and take down. We suggest a careful evaluation be made to determine safety equipment needed, such as hard hats, steel -toe shoes, safety glasses and other as required. It is our desire that all installations are safe. Please be aware of hidden dangers both underground, i.e., gas lines, water lines, electrical lines, etc. and above the tent such as power lines and telephone lines. 5. Anchor stands behind its products in accordance with its standard Terms and Conditions of sale. A copy of our Terms and Conditions of Sale can be obtained by contacting Anchor at the telephone number and/or address on this document. 28.2 03-04-09 IMPORTANT DOCUMENT Certificate of Flame 1fsistai ISSUED BY NHOR Registration Number INOU TRIES INC. F190/191 EVANSVILLE, INDIANA 47725 MANUFACTURERS OF THE FINISHED TENT PRODUCTS DE This is to certify that the materials described are inherently flame retardant and were A CLASSIC PARTY RENTAL DBA A CLASSIC PARTY RENTAL 1333 E 86TH ST INDIANAPOLIS, IN 46240 Date of Shipment 05/28/13 Sales Order # 15174593 HEREIN to: Certification is hereby made that: li The articles described on this Certificate have been treated with a flame-retardant approved chemical and that the application of said chemical was done in conformanrc��e with California Fire Marshall Code. All fabric has been tested and passes NFPA 701-04, ULc;109. Serial # 8040010C (1) Description of item certified: FIESTA EXP TOP 20WX20 (2PC) CLR VL W/SNYDER WHITE FACING Flame Retardant Process Used Will Not Be Washing And Is Effective For The Life Of ROBECO NEW YORK,NY Name of Applicator of Flame Resistant Finish Signed: ANCHOR oved By Fabric INC IMPORTANT DOCUMENT Certificate of Flame W§sistaj ISSUED BY Registration Number F 140.1r,�4.NCNORINDUSTRIES INC, 6 EVANSVILLE, INDIANA 47725 MANUFACTURERS OF THE FINISHED TENT PRODUCTS DE; This is to certify that the materials described are inherently flame retardant and were A CLASSIC PARTY RENTAL DBA A CLASSIC PARTY RENTAL 1333 E 86TH ST INDIANAPOLIS, IN 46240 Date of Shipment 05/28(13 Sales Order # 15174573 HEREIN to: Certification is hereby made that: The articles described on this Certificate have been treated with aflame -retardant approved chemical and that the application of said chemical was done in conformsr�V; e with California Fire Marshall Code. All fabric has been tested and passes NFPA 701-04, UL3 109. Serial # 8001600 (1) Description of item certified: FIESTA TOP 20WX20 WHITE SNYDER Flame Retardant Process Used Will Not Be Removed By Washing And Is Effective For The Life Of Te.Fabric SNYDER MFG NEW PHILADELPHIA OH Name of Applicator of Flame Resistant Finish Signed: ANCHOR INDUSTRIES INC IMPORTANT DOCUMENT Ceitificate of Flame Wpistar, ISSUED BY Registration Number 4D� R EO� F140.1 EVANSVILLE, INDIANA 47225 MANUFACTURERS OF THE FINISHED TENT PRODUCTS DES This is to certify that the materials described are inherently flame retardant and were A CLASSIC PARTY RENTAL DBA A CLASSIC PARTY RENTAL 1333 E 86TH ST INDIANAPOLIS, IN 46240 Date of Shipment 05/01113 Sales Order # 16173643 i HEREIN to: Certification is hereby made that: The articles described on this Certificate have been treated with a flame-retardant approved chemical and that the application of said chemical was done in conforma j'ce with California Fire Marshall Code. All fabric has been tested and passes NFPA 701-04, ULC 109. Serial # 8001600 (1) Description of item certified: FIESTA TOP 20WX20 WHITE SNYDER Flame Retardant Process Used Will Not Be Washing And Is Effective For The Life Of SNYDER MFG NEW PHILADELPHIA OH Name of Applicator of Flame Resistant Finish Signed: ANCHOR moved By e Fabric INC IMPORTANT DOCUMENT Certificate of Flame &sistanc ISSUED BY Registration Number 6 F190/191 INDC�BUSTRIESol NG. EVANSVILLE, INDIANA 47725 MANUFACTURERS OF THE FINISHED TENT PRODUCTS DESC This is to certify that the materials described are inherently flame retardant and were su A CLASSIC PARTY RENTAL DBA A CLASSIC PARTY RENTAL 1333 E 86TH ST INDIANAPOLIS, IN 46240 Date of Shipment 05/28/13 Sales Order # 15174593 HEREIN to: Certification is hereby made that: The articles described on this Certificate have been treated with a flame-retardant approved chemical and that the application of said chemical was done in conformance with California Fire Marshall Code. All fabric has been tested and passes NFPA 701-04, 1-11-6 109. Serial # 8020010C (2) Description of item certified: FIESTA EXP MID 20WX10 CLEAR VINYL W/SNYDER WHITE FACING Flame Retardant Process Used Will Not Be Removed By Washing And Is Effective For The Life Of The Fabric ROBECO NEW YORK. NY / li t Name of Applicator of Flame Resistant Finish Signed: ANCHOR INDUSTRlIES INC Lux, Pamela K From: Mike Wiggins <mike@aclassicpartyrental.com> Sent: Monday, August 19, 2019 1:07 PM To: Lux, Pamela K Subject: Premier permit **** This is an EXTERNAL email. Please exercise caution and Do Not open attachments or click links from unknown senders or unexpected email. **** Pam, I did want to let you know that the client has decided to allow us to stake the entire tent so the weights you see on the diagram will no longer be needed. Mike Wiggins Director of Outside Sales UVAIITY &f:NT Direct: 317.253.2423 Office: 317.251.7368, Ext. 107 WE'VE MOVED! 8020 Zionsville Road Indianapolis, IN 46268 aclassicoartvrental.com f *0 �J �r