HomeMy WebLinkAbout19080110 ApplicationstI" u` CITY OF CARMEL
TEMPORARY USE APPLICATION
e01�M'
PERMIT # 19 M 5 0 i 10
APPLICANT
NAME PHONE FAX
A CLASSIC PARTY RENTAL 317.251.7368
STREET ADDRESS CITY STATE ZIP
8020 ZIONSVILLE ROAD INDIANAPOLIS INDIANA 46268
E-MAIL ADDRESS
BEST METHOD OF CONTACT
MIKE@ACLASSICPARTYRENTAL.COM
CELL
PROPERTY
NAME PHONE FAX
OWNER
PREMIER FAMILY CHIROPRATIC 317.844.7000
STREET ADDRESS CITY STATE ZIP
120 EAST CARMEL DRIVE CARMEL INDIANA 46032
LOCATION
LOT NUMBER SUBDMSION BUILDER OF RECORD
OF PROJECT
STREET ADDRESS Cm STATE ZIP
120 EAST CARMEL DRIVE CARMEL INDIANA 46032
HAMILTON COUNTY PARCEL NUMBER ZONING NAME OF BUSINESS
TYPE OF
0 SPECIAL EVENT ❑ OUTDOOR SALES ❑ SEASONAL SALES ❑ MODEL HOME/SALES (BUILDING PERMIT # )
USE
❑ CONSTRUCTION FACILITY ❑ FIREWORKS SALES ❑ TEMPORARY CLASSROOM 0 FOOD STAND
DETAILS OF
DATES OF PROPOSED USE
HOURS OF OPERATION
USE
FROM: 8.29.19 TO: 8.29.19
6-9PM
WILL A TEMPORARY STRUCTURE BE REQUIRED? O YES ❑ NO
IF YES, SIZE OF STRUCTURE: 20'X 80' FRAME TENT MOBILE UNIT CERTIFICATE #:
WILL ASIGN BE REQUIRED? ❑ YES ❑ NO SIGN REVIEWED/RELEASED
*** THE FOLLOWING SECTION IS ONLY APPLICABLE TO FIREWORKS SALES ***
FIREWORKS WILL THE STRUCTURE BE USED FOR MORE THAN 500 LBS OF FIREWORKS? ❑ YES ❑ NO
SALES DOES THE STRUCTURE ALREADY HAVE A SPRINKLER SYSTEM INSTALLED7 ❑ YES ❑ NO
HAS THE STRUCTURE PREVIOUSLY BEEN USED FOR THE SALE OF FIREWORKS? ❑ YES ❑ NO
*** THE FOLLOWING SECTION IS ONLY APPLICABLE TO FOOD STANDS ***
FOOD PLEASE LIST ADDRESSES FOR UP TO 3 SALES AREAS
STANDS 1•
z.
3.
CERTIFICATION AND NOTICE OF INTENT TO COMPLY
I HEREBY CERTIFY THAT I HAVE THE AUTHORITY TO MAKE THE FOREGOING APPLICATION, THAT THE PLANS FILED WITH THE APPLICATION ARE
CORRECT, AND THAT THE OPERATION AND CONDUCT OF THE TEMPORARY USE WILL CONFORM TO THE REGULATIONS OF THE CARMEL UNIFIED
DEVELOPMENT ORDINANCE. FAILURE TO COMPLY WITH THE TERMS AND CONDITIONS OF THIS PERMIT MAY RESULT INA CITATION AND
ADDITIONAL FEES.
j. Miclu+ wl� ,tqu,tk MIKE WIGGINS 8.19.19
Sigmture of Owner or Authorized Agent Printed Name Data
REQUIRED BASE INSPECTIONS *
* Additional inspections may be required.
❑ Fire
❑
Final/ Site V
Reviewed / R — Department o /mnity Services D c
Valid Until:
PERMIT FEES
Temporary Use Fee
Base Inspections
Cert. of Occupancy
I $O, oo
TOTAL I D ad
Pee Received— Department of Community Services
Date
,1111 1
' III illilill Milli=111IMU fl
u
r
=00
0
9mm
mlvrd
r
U
i
w
0
N
g
1
r
Assembly Instructions 11
24' through 30' Wide Systems
With Expandable Kits
SALES OFFICES:
1100 BURCH DRIVE
PO BOX 3477
EVANSVILLE, IN 47733 USA
n
.a -
PHONE: 812-867-2421
FAX: 812-867-0547
1-800-544-4445
EMAIL: tents@anchorinc.com
www.anchorinc.com
PRODUCTION FACILITIES:
BRADENTON,FL
EVANSVILLE, IN
EC 3190 F12430 0706
R1 09-11
t
qV
24' through 30' Wide Systems
With Expandable Kits
SALES OFFICES:
1100 BURCH DRIVE
PO BOX 3477
EVANSVILLE, IN 47733 USA
n
.a -
PHONE: 812-867-2421
FAX: 812-867-0547
1-800-544-4445
EMAIL: tents@anchorinc.com
www.anchorinc.com
PRODUCTION FACILITIES:
BRADENTON,FL
EVANSVILLE, IN
EC 3190 F12430 0706
R1 09-11
o1v a v �v en •
• wv OQO-p v � •
•- r" ' of +�� . . �`p o i
o ins a i
w
O '
w
0
, rrw�rw�wrr�rrrr�— o.rrr�rrrirrr�r. ,
PARTS
LIST
CHECKED
REQUIRED
I PTT
4 PTC
4 PTI
4-2pa
4`
4
4
4
4
8
16
8
16
1
1
i
30" tipbl:L
-gyp 10" NAIL STAKE
STORAGE BAG FOR TOP
INSTALLATION SHEET
STAKE
WRENCH FOP PTC
added stabiiity,
INSPECT SITE
Prior to actual frame assembly be
6 GUY WEBS sure to look up, down, above &below
INTERMEDIATE RAFTER for obstacles, pipes, wires, trouble,
B etc.
CHECKED BY:
DATE:
(2) PAMRS HAVE AN
ADDI1110NAL RTE&3 ATTACHED
2
�1Y�7UT & CHECK
Utilize parts list for a quick LD. and to ensure that
you have all the parts.
SAVE ASSEMBLY*
Begin by placing PTI casting over
Female Eave Bar. Then join Male
Eave Bar with long pin from PTI
through bars only. Do not pin
through PTI. Nut holding PTEB must
be on top of bar.
Insert complete eaves into PTC
casting and hand tighten PTC nut.
Use Fiesta wrench for a+la to Yz
additional turn, Do not over tighten.
PTI
EB;; i mu "��►�
. s .
27 HIP & PEAK
Join male and female ends of
two-piece Hip and secure with pin.
Insert Hip Bar into PTC Corner
Casting. Fasten with short pin.
Insert opposite end into PTT Peak
Casting and fasten with pin.
A second installer should support the
PTT while hips are being attached.
0 RAFTERS & BRACES*
Insert Raker Bar into PTI Casting;
fasten with short pin. Insert opposite
end into PTT Casting and fasten with
pin.
Connect Hip Brace to PTEB-3's on
Hip and Rafter using pins attached.
Connect Intermediate Rafter to PTEB-3's
on Hip and Eave using pins attached.
*For 10'-0" starter kit and extension
parts and instructions, see pages 5 & 6..
hip
female
�F�TEB PTI
PTC
_��A!- t male
lim
hip w/PTEB-3
W
rafter w/PTEB-3
3
4 PUT TOP ON
Spread drop cloths. Lay out two piece top
with lace edges together and top side up.
Matching centerlines, push first loop up
through corresponding grommet. Continue
lacing process and cover lacing with protec-
tive flap and snap to rings, Tie off last long
lacing loop. Repeat steps on opposite side
starting with second loop from ridge. Place
top over frame, Fasten a Fiestab buckle at
each side of comers and at center of each
side (more if required) to keep top from
blowing off.
LiFT ONE SIDE
Lift one side of frame, insert both
Corner Uprights into PTC Corner
Castings and fasten with long pin.
Then Insert Intermediate Upnght
Into PTI Casting and fasten with
long pin.
CAUTION,
Braces at both corners and inter-
mediate upright"MUST" be in
position before lifting other side.
hip
female PTEB
ea fe a male save
PTC upright brace
_, upright
® LIFT OTHER SIDE
Lift other side of frame, insert both
Corner Uprights into PTC Corner
Castings phd fasten with long, pin,
Then Insert intermediate Upright
into PTI Casting and fasten with
long pin.
CAUTION:
Braces at both corners and
intermediate upright "MUST" be in
position before lifting other side.
Fr
arning: o no rao a ric tent top
ross hard or rough surfaces as abrasion
m tent hardware is possible.
70
F
Put strap behind
save bar and up
through buckle,
SECURE TOP TO FRAME
Starting at center of opposite sides,
fasten Fiesta buckles to frame,
wrap web strap around save bar
and wail rope, then tension with
buckle.
TAKE DOWN
�8 WEBS & STAKES
Position tent as desired. (if uprights
adjustable, raise to proper height.)
Attach guy web and stakes as shown.
Periodically check to make sure all
are secure and taut.
Protective covers are recommended
for all stakes.
"See caution on back page."
IMPORTANT.
Guy webs must be in place at all
times.
1. Release straps and buckles.
2. Remove Intermediate uprights
on three sides. Leave installed on side
to be taken down last.
3. "Loosen" all guy webs.
4. Starting on one side — remove all braces.
CAUTION:
Do not remove braces from opposite
side until first side is lowered to ground,
5. Remove (2) corner uprights and lower one
side to ground,
6. Repeat assembly steps #146 in reverse
for disassembly.
MANPOWER REQUIRED:
Three experienced installers should be able
to assemble in less than one and one-half
hours.
TOOLS REQUIRED:
Sledge Hammer
Fiesta Wrench (supplied)
eye bolt
in PTC
a' -o"
corner
upright
,(2) 10" nails in
each base plate.
Hammer down
flush with base
plate to secure.
SUPPLEMENTAL INSTRUCTIONS TO EXTEND LENGTH BY 10'0"
10' STARTER KIT r� 3
or,
PTEB•3 g
' ��y {��A[�_CROSSBT
ARRANGE FARTS \ f j SUPPORT L
FOR ASSEMBLY
JSTORAGEBAG I
n WITH TOP
Ab8i
INTER-
MEDIATE
UPRIGHTS
STAKES
r-�
a
GUY WEBS
'r
NAILS FOR UPRIGHT
BASE PLATES
PARTS LIST
CHECKED RECUIRW
1
2
2
2
z
2
1
2
2
4
2
4
2
1
10'•0"
2 PC SUPE
RAFTERPTI 10'•0" EAVE T
U*rvu;
BRACEE =7
10' STARTER FRAME MEMBERS ARE NOT SHADED,
FOR ADDITIONAL EXTENSIONS, SEE NEXT PAGE,
PTr
PTI W I EYE BOLT
To]
UPRIGHT BRACE
30`STEELSTAKE
Via.. WNAILSTAKE
GUY WEBS
INSTRUCTION SHEET
378 RIDGE & CROSS BARS
Connect 2 -pc ridge and pin to PTTs using the PTRE
pointed downward so that the ridge is elevated.
Pin cross bars together and attach to frame as shown.
MANPOWER REQUIRED
Four experienced installers should be able to
assemble in less than two hours.
PTRE
PTEB•3
PTT
2 PC RIDGE
CROSSBAR
SUPPORT
PTT•PTI
�`�`4....
RAFTER
EPPCCC
CROSSBAR
PTN
PTES-3
SUPPLE
110' EXTENSION KIT
ARRANGE PARTS
FOR ASSEMBLY
=IRIA
STAKES
INTER -
GUY WEBS MEDIATE
UPRIGHTS
NAILS FOR UPRIGHT
BASE PLATES
PARTS LIST
CHECKEC REQUIRED
PTN
i PTR
2 PTI W i CYE BOLT
2 PfRTIM MWXTKM
IP EAVE WIl PT€&9
t ItlCWWE
2 I �NfFl4Up1YAi1/WTF&
1 � CR0490Aq
i{��- --�� UPRIGHT BRACE
2 D=� SC•STEELSTAKE
4 l 10'NAILSTAKE
2 GUY WEBS
1 INSTRUCTION SHEET
JCTIONS TO EXTEND LENGTH BY 14'0"
M BAR
PTEB3 UPPOR
0
11
10,.0"
RIDGE �,
PTR u PTN
PTR -PTI
RAFTER p PC
CROSS BAR ��'
��'77 PTI
UPRIGHT w
EAV
1D' EXTENSION FRAME MEMBERS ARE NOT SHADED.
FOR ADDITIONAL EXTENSIONS, REPEAT FRAME PATTERN.
LENGTH OF EXTENDED FRAME IS 10'
EXTENSION
NOT TO EXCEED TWICE THE WIDTH.
3,a RIDGE & CROSS BAR
Slide PTR on to 10'-0" ridge. Align with hole at center of
ridge and pin. Repeat for each 10'-0" ridge. Pin 10'-0"
ridges together and add existing ridges to each end. Lift
and pin assembled ridges to PTT's, using the PTRE
pointed downward so that ridges are elevated.
Insert PTR -PTI rafters into PTRs and PTIs and pin.
Pin Cross Bars together and attach to frame as shown.
MANPOWER REQUIRED
Five Installers and two and one half hours
assembly time for a 30'x 50' unit.
rA
NCHOR o
INDUSTRIES INC.
EVANSVILLE, INDIANA
PHONE NUMBER
812.867.2421
FAX NUMBER
812.867.0547
Anchor products are of superior design and operate best within the parameters of these instructions. It is imperative
that the instructions be carefully read and COMPLETELY FOLLOWED. Please read installation instructions before the
installation or removal of this product. Installation instructions are available online at www.anchorinc.com or by calling
1-800-544-4445.
CAUTION:
1. For each installation, the installer is solely responsible for evaluating the site and the proper securing method
determined. Some soils require different staking or securing than that provided with the tent. Due to this variety of
soil conditions, these are the manufacturer's suggested sequence of installation procedures. Anchor's responsibility
is limited to the manufacture of the tent parts and materials. We are not responsible for methods that installers may
choose to erect and secure the tent to the ground.
2. The number of stakes suggested in the installation instructions do not necessarily meet all or any relevant codes
on the site of the tent installation. The number of stakes suggested will, in many cases, keep the tent erected,
however, due to various soil conditions; these stakes will be insufficient to keep the tent secure in high winds.
It is the tent installer's responsibility, not the manufacturer, to determine the appropriate number of stakes to meet
the necessary wind loads on the site. Regardless of the number of stakes we suggest, we make no representation
or warranty as to whether this specific number of stakes will meet the local tent code. Anchor does not, nor can
it make any suggestions, representation, or warranties about the adequate staking required at each specific
installation site. Staking information provided in the installation instructions is not a suggestion about what is
necessary to meet a site-specific load.
For additional important information, consult: "The IFAI Procedural Handbook For the Safe Installation and
Maintenance of Tentage" and the IFAI Pocket Guide "Pullout Capacity of Tent Stakes", both available from
the IFAI Tent Rental Division or on our website.
3. Inasmuch as the weather is unpredictable, good judgment and common sense must be incorporated within
installation guidelines. It is the responsibility of the tent installer/maintainer to determine the severity of the weather,
proper time and method of installation and/or erection and disassembly. Note: We recommend that snow and
ice be removed from the tent surface as soon as possible because accumulation will damage the tent
or fabric structure. Please consult with our Engineering Department about the maximum loads for each
product.
This product has been manufactured for use as a temporary structure. For the safety of all occupants, evacuation
is recommended if threatening weather occurs, or if there is any doubt concerning the safe use of this product.
4. Proper safety equipment should be used at all times to insure a safe installation and take down. We suggest a
careful evaluation be made to determine safety equipment needed, such as hard hats, steel -toe shoes, safety
glasses and other as required. It is our desire that all installations are safe. Please be aware of hidden dangers
both underground, i.e., gas lines, water lines, electrical lines, etc. and above the tent such as power lines and
telephone lines.
5. Anchor stands behind its products in accordance with its standard Terms and Conditions of sale. A copy of our
Terms and Conditions of Sale can be obtained by contacting Anchor at the telephone number and/or address on
this document.
28.2 03-04-09
IMPORTANT DOCUMENT
Certificate of Flame 1fsistai
ISSUED BY
NHOR
Registration Number INOU TRIES INC.
F190/191
EVANSVILLE, INDIANA 47725
MANUFACTURERS OF THE FINISHED TENT PRODUCTS DE
This is to certify that the materials described are inherently flame retardant and were
A CLASSIC PARTY RENTAL
DBA A CLASSIC PARTY RENTAL
1333 E 86TH ST
INDIANAPOLIS, IN 46240
Date of Shipment
05/28/13
Sales Order #
15174593
HEREIN
to:
Certification is hereby made that: li
The articles described on this Certificate have been treated with a flame-retardant approved
chemical and that the application of said chemical was done in conformanrc��e with California Fire
Marshall Code. All fabric has been tested and passes NFPA 701-04, ULc;109.
Serial # 8040010C (1)
Description of item certified: FIESTA EXP TOP 20WX20 (2PC)
CLR VL W/SNYDER WHITE FACING
Flame Retardant Process Used Will Not Be
Washing And Is Effective For The Life Of
ROBECO NEW YORK,NY
Name of Applicator of Flame Resistant Finish Signed: ANCHOR
oved By
Fabric
INC
IMPORTANT DOCUMENT
Certificate of Flame W§sistaj
ISSUED BY
Registration Number F
140.1r,�4.NCNORINDUSTRIES INC, 6
EVANSVILLE, INDIANA 47725
MANUFACTURERS OF THE FINISHED TENT PRODUCTS DE;
This is to certify that the materials described are inherently flame retardant and were
A CLASSIC PARTY RENTAL
DBA A CLASSIC PARTY RENTAL
1333 E 86TH ST
INDIANAPOLIS, IN 46240
Date of Shipment
05/28(13
Sales Order #
15174573
HEREIN
to:
Certification is hereby made that:
The articles described on this Certificate have been treated with aflame -retardant approved
chemical and that the application of said chemical was done in conformsr�V; e with California Fire
Marshall Code. All fabric has been tested and passes NFPA 701-04, UL3 109.
Serial # 8001600 (1)
Description of item certified: FIESTA TOP 20WX20 WHITE
SNYDER
Flame Retardant Process Used Will Not Be Removed By
Washing And Is Effective For The Life Of Te.Fabric
SNYDER MFG NEW PHILADELPHIA OH
Name of Applicator of Flame Resistant Finish Signed: ANCHOR INDUSTRIES INC
IMPORTANT DOCUMENT
Ceitificate of Flame Wpistar,
ISSUED BY
Registration Number 4D� R EO�
F140.1
EVANSVILLE, INDIANA 47225
MANUFACTURERS OF THE FINISHED TENT PRODUCTS DES
This is to certify that the materials described are inherently flame retardant and were
A CLASSIC PARTY RENTAL
DBA A CLASSIC PARTY RENTAL
1333 E 86TH ST
INDIANAPOLIS, IN 46240
Date of Shipment
05/01113
Sales Order #
16173643
i HEREIN
to:
Certification is hereby made that:
The articles described on this Certificate have been treated with a flame-retardant approved
chemical and that the application of said chemical was done in conforma j'ce with California Fire
Marshall Code. All fabric has been tested and passes NFPA 701-04, ULC 109.
Serial # 8001600 (1)
Description of item certified: FIESTA TOP 20WX20 WHITE
SNYDER
Flame Retardant Process Used Will Not Be
Washing And Is Effective For The Life Of
SNYDER MFG NEW PHILADELPHIA OH
Name of Applicator of Flame Resistant Finish Signed: ANCHOR
moved By
e Fabric
INC
IMPORTANT DOCUMENT
Certificate of Flame &sistanc
ISSUED BY
Registration Number 6
F190/191 INDC�BUSTRIESol NG.
EVANSVILLE, INDIANA 47725
MANUFACTURERS OF THE FINISHED TENT PRODUCTS DESC
This is to certify that the materials described are inherently flame retardant and were su
A CLASSIC PARTY RENTAL
DBA A CLASSIC PARTY RENTAL
1333 E 86TH ST
INDIANAPOLIS, IN 46240
Date of Shipment
05/28/13
Sales Order #
15174593
HEREIN
to:
Certification is hereby made that:
The articles described on this Certificate have been treated with a flame-retardant approved
chemical and that the application of said chemical was done in conformance with California Fire
Marshall Code. All fabric has been tested and passes NFPA 701-04, 1-11-6 109.
Serial # 8020010C (2)
Description of item certified: FIESTA EXP MID 20WX10 CLEAR
VINYL W/SNYDER WHITE FACING
Flame Retardant Process Used Will Not Be Removed By
Washing And Is Effective For The Life Of The Fabric
ROBECO NEW YORK. NY / li t
Name of Applicator of Flame Resistant Finish Signed: ANCHOR INDUSTRlIES INC
Lux, Pamela K
From: Mike Wiggins <mike@aclassicpartyrental.com>
Sent: Monday, August 19, 2019 1:07 PM
To: Lux, Pamela K
Subject: Premier permit
**** This is an EXTERNAL email. Please exercise caution and Do Not open attachments or click links
from unknown senders or unexpected email. ****
Pam,
I did want to let you know that the client has decided to allow us to stake the entire tent so the weights you see on the
diagram will no longer be needed.
Mike Wiggins
Director of Outside Sales
UVAIITY &f:NT
Direct: 317.253.2423
Office: 317.251.7368, Ext. 107
WE'VE MOVED!
8020 Zionsville Road
Indianapolis, IN 46268
aclassicoartvrental.com
f *0 �J �r