HomeMy WebLinkAboutALB 27- Sewer Permit10701 N Cclie e Avenue Suite A Ind-a^app s i^G a a 4623 pt.one 3'7-844-920:, fax 37-344-y2'3 wKu.-SO LSC Residential SANITARY SEWER PERMIT 999913373 Permit Type Final Subdivision Albany Place Project WO ENG332015 Section Number 2 Project Name Albany Place Section 1 Lot Number 27 Project Developer Platinum Properties Address Number 3557 Lift Station 23 126th Street Station Address 2 Treatment Plant MIX Street Marsdale Court Parcel Acreage 0 38 City Carmel EDU in Gallons 310 Zip Code 46674 County Hamilton Local Sewer Charge - District Contribution 0.00 guilder Drees Homes Plan Review and Inspection 0.00 Application Fee 150.00 Phone Number 317-347-7300 EDU Fee 1906.00 Owner Interceptor Fee 0.00 Phone Number Other Fees 0.00 Fees Due 2058.00 Occupant Invoice Number Phone Number PLEASE NOTE; Installation of building sewer shall be per the specifications of the TnCo Regional Sewer UU4 (see reverse) and any conditions noted below. All installations shall be inspected by TnCo personnel during "open trench" phase and before backfilling with stone to twelve inches above the pipe NO footing or foundation drains, or other sources of ground or stormwater, shall be permitted to enter TnCo's sanitary sewer system. ThCo will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be responsible for damages to TriCo's sewer system This includes damages to manholes, castings, manhole lids an the like; caused by construction activity on the building site which is the subject of this permit. Inspections by TfiCo are MANDATORY and shall be arranged by contacting TnCo's office at 844-9200 24 hours In advance. All new construction will be piaced on biding two months after connection has been made or when water is connected, whichever comes first. The building has: Main ID AP700-AP703 Grease Trap Slab Foundation usMr Grease Interceptor Crawl Space Manhole IDs AP -Too AP -703 DSMH Grit interceptor Basame tt ..S Lid Elevation 917.4/920.19 W11Grinder Station First Floor Elevation 921,20 t/ 92120 Water Service City of Carmel Basement Elevation 91000 / 910.001/ CakulatiOn is based on both Manhole Lid Elevations and the elevation of the First Floor 3.80 1.01 Ft. Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only y� TnCo currently requires that an Al inspection is performed and a Certificate of Compliance is issued prior to occupancy ! �Q sale of a properrty. Please review attached Ill Permit. Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner. The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure. The terns of the conditional permit, if any, are listed below. Plans have been submitted. All fees have been paid. No certificate of insurance required. No additional permits required. No manhole core permit required. The facility is not classified as a FOG facility. (Notes) Dy signing oeiow, i driest mat I V -&, s speanc sons ana agree to accept responsionory for all work done under this permit, Builder! Owner SignaturPhone Number G� Printed NamiApproved BorTriCO Permit is vthe date issued. Permit valid only with TriCo s re ink 0 0 i R�tl NL NMN��Z�M