Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S001.02
UP 17 RISERS - WOOD TREAD/RISERS TUB/ SHOWER W.C. L. TOWELS SHOWER W.C. L. BEDROOM #2 - 8'9" CEILING HEIGHT - CARPET FLOOR BEDROOM #3 - 8'9" CEILING HEIGHT - CARPET FLOOR BATHROOM - 8'9" CEILING HEIGHT - LVP FLOOR BATHROOM - 8'9" CEILING HEIGHT - LVP FLOOR CLOSET CLOSET MECHANICAL/STORAGE - 8'9" CEILING HEIGHT - CONCRETE FLOOR (TREATED) FITNESS - 8'9" CEILING HEIGHT - CONCRETE FLOOR (UNTREATED) FUTURE SAUNA - 8'9" CEILING HEIGHT - CONCRETE FLOOR (UNTREATED) KITTY ROOM - 8'9" CEILING HEIGHT - CONCRETE FLOOR (TREATED) MEDIA AREA - 8'9" CEILING HEIGHT - LVP FLOORWALK UP BAR AREA ROUGH-INPLUMBING/DRAIN FOR SINKUNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL WINDOW WELL WINDOW WELL CRAWLSPACE STORAGE CLOSET CLOSET 3 '0"x6 '8" 3 '0"x6'8 "3'0"x6'8" 2 '8 "x6 '8"2'8 "x6 '8 " 2' 6 " x6 ' 8 "2 '6 "x6 '8"2'6"x6'8"POCKET DOOR3'0 "x6'8"2'6"x6'8 " 2' 6"x6 ' 8 "2'6"x6'8"2'6 "x6'8 "3'0"x6'8"2'8"x6'8""X" INDICATES 4" DROP FLOOR SYSTEM FOR MASTER SHOWER FLOOR UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL UNEXCAVATED - 4" MIN. CONCRETE SLAB- GRAVEL FILL2 PLY"x1178"LVL HDR.31 2x31 2x1 4" STL. COL. W8x13# STL. BEAM31 2x31 2x 1 4" STL. COL. 1 7 1 7 6 7 6 7 7 2 7 2 8 4 8 4 8 5 8 3 2646-2 8'-33 4" 4"12'-212"312" 3'-3"4" 4"7'-21 2" 31 2" 7'-21 2" 31 2" 4'-111 2" 31 2"5'-0"31 2"9'-3"31 2"12'-2"31 2" 8'-61 2"4"3'-112"4"8'-4" 312"7'-512" 312" 8'-8"312"19'-612" 9'-11"4" 19'-91 2" 31 2"16'-11"31 2" 4'-11 2"4"8'-434"312" 8'-434" 4"31 2"5'-0"31 2"3'-91 2"31 2"15'-8"31 2"4'-1" 4"2'-10"312"6'-512" 4"312" 10'-113 4" 2646-2 4"4'-212"10'-81 2"32" CRAWLSPACE ACCESSDBL. FLOOR JST. 2'0"x6'8" CLOSET 4'-1"31 2"2'-4"31 2"3'-1"2'-1"312"2'-10"3'-112"312" WATER SOFTNER BYPASS 50 GAL ELECTRIC AWH 50 GAL ELECTRIC AWH GAS FURNACE w/ HUMIDIFIER EJECTOR PITSUMP PUMP w/BATTERY BACKUP- 8'9" CEILING HEIGHT - LVP FLOOR CONCRETE BLOCK WALLS CONSTRUCTION LEGEND FRAME WALLS 1. MATERIALS LEGEND BEARING WALLS CONCRETE WALLS 2. GENERAL NOTES * DIMENSIONS TO FACE OF STUD * 8'9" CEILING HEIGHT UNLESS OTHERWISE NOTED * ZONED HVAC * SMOOTH CEILINGS Designed For:Westvale Lot 92Stump ResidenceDate: 08-20-19Plan number #190601H. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174 - www.hgmccullough.comMake yourself at homeMcKENZIECOLLECTION.COM 4631LisbornDriveCarmel,IN46033 317.574.7617P02SCALE: 1/4"=1'-0"LOWER LEVEL FLOOR PLAN SHEET NUMBER 08/30/19 Mike Sheeks