HomeMy WebLinkAboutWESTVALE AT JACKSONS GRANT 92 - JGW092 (AS DESIGNED)IECC. 2009 Performance Compliance
Property
1265 FRENZEL PKWY
CARMEL, IN 46032
Model: CUSTOM
Community: WESTVALE AT JACKS(
JGWO92 (AS DESIGNED)
WESTVALE AT JACKSONS GRANT
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE,
INC.
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,856
$313
$329
$2,497
$1,417
$0
$3,914
Requirements
C-M,
Energy Solutions
As Designed
$1,856
$249
$329
$2,433
$1,417
$0
$3,850
C4405.3
Performance -based compliance passes by 2.5%
R402.4.1.2
Air Leakage Testing Air sealing is 5.0[) ACH at 50 Pa. It must not exceed 7.013 ACH at 50 Pa.
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U-Factor
403.2.2
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R405.2
Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 2.5%.
Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name
Organization
Devin Sielschott
TSI Energy Solutions
Signature:
Date:
8/12119 at 12:53 PM
Ekotrope RATER - Version 3.1.0.2231
IECC 2009 Performance compliance results calculated using Eketrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all1iabitityfor the information shown on this report.
1265 FRENZEL PKWY
CARMEL, IN 46032
Builder: HOMES BY McKENZIE, INC.
Ceiling Attic, R-50
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor NIA
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U-Value: 0.29, SHGC: 0.27
Building Features
Duct Supply R-6.0, Return R-20.0
Duct Leakage to Outside 232 CFM25 (3.94 / 100 s.f.)
Total Duct Leakage 464 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric - 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 8/12119 at 12:53 PM
Ekotrope RATER - Version 3.1.0.2231
2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property Organization
1265 FRENZEL PKWY TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CUSTOM
Community: WESTVALE AT JACKS( Builder
HOMES BY McKENZIE,
JGW092 (AS DESIGNED) INC.
WESTVALE AT JACKSONS GRANT
General Building Information
Conditioned Area (sq ft) 5,883
Conditioned Volume (cubic ft) 59,407
Insulated Shell Area (sq ft) 11,921
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT(2,770 s.f., 233 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
] Name: CRAWL(343 s.f., 47 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
] Name: FIN (Exterior Perimeter [ft]: 192, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 10.595
Fully insulated (top to bottom)
1] Name: UNFIN (Exterior Perimeter [ft]: 42, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
J--1 R:0.00
Fully insulated (top to bottom)
1� Name: CRAWLIAMB (Exterior Perimeter [ft]: 47, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2)
1-� R: 10.00
Fully insulated (top to bottom)
Above Grade Wall
1
Energy Code Inspection Checklist
Property Organization
1265 FRENZEL PKWY TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CUSTOM
Community: WESTVALE AT JACKS( Builder
HOMES BY McKENZIE,
JGWO92 (AS DESIGNED) INC.
WESTVALE AT JACKSONS GRANT
Name: CONDIAMB (2,508 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CON DIGAR (480 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CON DIATTIC (179 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
1� Name: RIM CONDIAMB (233 s.f.)
1--1 R:11.691
Roof
Name: CONDIGAR (48 s.f.)
R: 11.691
Name: MAIN (3,113 s.f.)
R-39.73 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
1� Name: GARAGE (48 s.f.)
1--1 U:0.182
El Name: GARAGE (24 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
11 Name: FRONT (58 s.f.), U: 0.290, SHGC: 0.27, Orientation: EAST
C",
Energy Solutions
2
Energy Code Inspection Checklist
7'SI Energy Solutions
Property Organization Inspection Status
1265 FRENZEL PKWY TSI Energy Solutions Results are projected
CARMEL, IN 46032 Devin Sielschott
Model: CUSTOM
Community: WESTVALE AT JACKS[ Builder
HOMES BY McKENZIE,
JGW092 (AS DESIGNED) INC.
WESTVALE AT JACKSONS GRANT
Name: BACK (194 s.f.), U: 0.290, SHGC: 0.27, Orientation: WEST
E] Name: LEFT SIDE (125 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH
E] Name: GD (20 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH
[] Name: RIGHT SIDE (123 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH
El Name: GO (24 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH
El Name: RIGHT SIDE BSMT (55 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH
1I Name: LEFT SIDE BSMT (55 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
1 HEATING 1 - Natural Gas - 100% Heating Load @ 92.1 AFUE
AC 1 - Electric - 100% Cooling Load @ 13 SEER
0 Water Heating • Electric - 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 4,951 CFM50 (5.00 ACH50) or less at final blower -door test.
3
Energy Code Inspection Checklist
Property Organization Inspection Status
1265 FRENZEL PKWY TSI Energy Solutions Results are projected
CARMEL, IN 46032 Devin Sielschott
Model: CUSTOM
Community: WESTVALE AT JACKS( Builder
HOMES BY McKENZIE,
JGW092 (AS DESIGNED) INC.
WESTVALE AT JACKSONS GRANT
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC. Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 232 CFM25 (3.94 / 100 s.f.)
Total Leakage specified as: 464 CFM25 (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM251 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization
Energy Solutions
Inspection Status C-M
1265 FRENZEL PKWY
TSI Energy Solutions
Results
are projected
CARMEL, IN 46032
Devin Sielschott
Model- CUSTOM
Community: WESTVALE AT JACKSONS GRANT 92
Builder
HOMES BY MCKENZIE, INC.
JGW092 [AS DESIGNED]
WESTVALE AT JACKSONIS GRANT 92
General Building Information
Number Of Bedrooms
3
Number Of Floors
1
Conditioned Floor Area [sq_ ft.]
5,883
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
59,407
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
CUSTOM
Community
1NESTVALE AT JACKSONS GRANT 92
Climate Zone
5A
Foundation Wall
Name Library type
Height Above Grade Depth Below Grade
Perimeter Location Enclosing
CRAWUAMB R-10 Draped, Full
1
2
47 Exposed Exterior Conditioned Crawlspace
FIN R-13 Finished, G1
1
8
192 Exposed Exterior Conditioned Space
UNFIN Uninsulated
1
8
42 Exposed Exterior Conditioned Space
Foundation Wall Library List.
Name Feet From Wall TOTo Feet From Wall Top To Is Fully Insulated
Continuous R-value Cavity R-value Effective Insulation R-
Continuous Insulation Continuous Insulation
value
Top
Bottom
R-10 Draped, Full N-A
NIA
Yes
NIA NIA 10.00
R-13 Finished, G1 NIA
NIA
Yes
NIA NIA 10.595
Uninsulated NIA
NIA
Yes
NIA NIA 0.00
Name Library type Perimeter Floor Grade
Carpet R
Exposed Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated
233 Below Grade
0
0 2,770.0 ft' Exposed Exterior Conditioned
Space
CRAWL Uninsulated
47 Below Grade
0
0 343.0 ft Exposed Exterior Conditioned
Crawlspace
1
Building Summary
Property
Organization
C-MEnergy Solutions
Inspection Status
1265 FRENZEL PKWY
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Devin Sielschott
Model- CUSTOM
Community: WESTVALE AT JACKSONS GRANT 92
Builder
HOMES BY McKENZIE,
INC.
JGW092 [AS DESIGNED]
WESTVALE AT JACKSONIS GRANT 92
Slab Library List
Name Wall Construction
Slab Completel�r
Underslab
Perimeter Perimeter Thermal Break Effective R-value
Type
Insulated. Insulation Width [ft] Insulation Depth [It] Insulation R Value
Uninsulated Wood Frame I Other
No
0
0 ❑ No 000
Framed Floor
M
None Present
Framed Floor Library List Ir
None Present
Rim Joist
Name Library Type Surface Area Location
CONDIGAR G1 R-15, OSB 48.0 ft' Unconditioned, attached garage
RIM CONDIAMB G1 R-15, OSB 233.0 ft' Exposed Exterior
Rim Joist Library List
Name Effective Insulation R-value
G1 R-15: OSB 11.691
all
J
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB
G1 R-15 BATT, OSB
Medium
2,508.0 ft'
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, OSB
Medium
1790 ft'
Attic
Building Summary
Property
Organization
1265 FRENZEL PKWY
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model- CUSTOM
Community: WESTVALE AT JACKSONS GRANT 92 Builder
HOMES BY McKENZIE, INC.
JGW092 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 92
Name
Library Type
CONDIGAR
G1 R-15 Gar Walls
Wall Library List
Name
Effective R-value
G1 R-15 BATT. OSB
13.423
G1 R-t 5 Gar Walls
11 972
Glazing
C-M
Energy Solutions
Inspection Status
Results are projected
Surface Color Surface Area Location
Medium 480.0 fts Unconditioned. attached garage
Name
BACK
Library Type Wall Assignment
U-.29, SHGC-.27 CONDIAMB
Foundation Wall
Assignment
Overhang Depth
0
Overhang Ft To
Top
0
Overhang Ft To
ottom
0
Orientation
West
Surface Area
194.GTF
FRONT
U-29, SHGC-.27
CONDIAMB
0
0
0
East
58.0ft2
GD
U-29, SHGC-27
CONDIAMB
0
0
0
South
20.0ft2
GD
U-29, SHGC-27
CONDIAMB
0
0
0
North
24.0ft2
LEFT SIDE
U-29, SHGC-27
CONDIAMB
0
0
0
South
125.0ft2
LEFT SIDE BSMT
U-29, SHGC-27
FIN
0
0
0
South
55.0ft2
RIGHT SIDE
U-29, SHGC-27
CONDIAMB
0
0
0
North
123.0ft'
RIGHT SIDE BSMT
U-29, SHGC-27
FIN
0
0
0
North
55.Dfts
Glazing Library List
Name
U-29, SHGC-27
Shgc
C.27
0290
Building Summary
Property
Organization
1265 FRENZEL PKWY
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model- CUSTOM
Community: WESTVALE AT JACKSONS GRANT 92
Builder
HOMES BY McKENZIE, INC.
JGW092 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 92
Skylight
Skylight Library List
None
Opaque Door
Name Library Type Wal I Assi g n meni
GARAGE Fiberglass/Steel CONDIGAR
Door
GARAGE Fiberglass/Steel CONDIGAR
Door
Opaque Door Library List -in
Name E
FiherglasslSteel Door
Roof Insulation
Name
MAIN R-5n Rlnwn C P1
Assignment
01132
C-M
Energy Solutions
Inspection Status
Results are projected
nce sonar surrace uoior surrace Area Locanor
Absorptan oe
0.9 0.75 Medium 48.0 fts Exposed Exterior
0.9 0.75 Medium 24.0 fts Exposed Exterior
3.113 No Medium 3,113.0 fl- Attic
Roof Insulation Library List
Name Has Radiant Barrier
R-50 Blown, GR1 `Jc
Effective R-value
50.474
4
Building Summary
Property
Organization Inspection Status
1265 FRENZEL PKWY
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Devin Sielschott
Model- CUSTOM
Community: WESTVALE AT JACKSONS GRANT 92
Builder
HOMES BY MCKENZIE, INC.
JGW092 [AS DESIGNED]
WESTVALE AT JACKSQNS GRANT 92
Whole House Infiltratio
Iiiiiiiiiiiir
Infiltration Measurement type Shelter Class
5 ACH at 50 Pa
Blower -door tested
Mechanical Ventilation
None Present
Lighting
°I Interior Fluorescent % Interior LED Lighting
Lighting
0 p
4
C-M,
Energy Solutions
% Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting
Lighting Lighting
0 0 a a
Onsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
5
Building Summary
Property Organization
1265 FRENZEL PKWY TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model- CUSTOM
Community: WESTVALE AT JACKSONS GRANT 92 Builder
HOMES BY MCKENZIE, INC.
JGW092 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 92
Conditioning Equipment
Name Literary type Heating Percent Ldac
AC 1 13ACX-042-230 0%
HEATING 1 912SA48100S17 100%
Water Heatinq ENT 50 100 0%
quipment Type: 13ACX-042-230
C-M
Energy Solutions
Inspection Status
Results are projected
ng Percent Load Hot Water Percent LOad LCCaliOn
100% 0% Conditioned Space
0%
0% Conditioned Space
0% 100% Conditioned Space
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
41.5
Equipment Type: 9125A4810051L
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
93
Use default EAE
No
EAE [kWh]
756
Equipment Type: ENT 50 100
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
Building Summary
Property
Organization
1265 FRENZEL PKWY
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model- CUSTOM
Community: WESTVALE AT JACKSONS GRANT 92
Builder
HOMES BY MCKENZIE, INC.
JGW092 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 92
Distribution System
Distribution Type
Forced Air
Heating Equipment
HEATING 1
Cooling Equipment
AC 1
Sq. Feet Served
5883
# Return Grilles
3
Supply Duct R Value
6
Return Duct R Value
20
Supply Duct Area [ft2]
1588.41
Return Duct Area [ft2]
882.45
Leakage to Outdoors
232 CFM25 (3.941 100 s.f.)
Total Leakage
464 CFM25
Total Leakage Dud Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
❑
Percent Return Area
50
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
100
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
1265 FRENZEL PKWY
CARMEL, IN 46032
Model- CUSTOM
Community: WESTVALE AT JACKSONS GRANT 92
JGW092 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 92
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE, INC.
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
75
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
30
Drain Water Heat Recovery?
No
Clothes Dryer
Fuel Type Electric
Cef 2.617
Field Utilization Timer Controls
asher WVWV
Label Energy Rating
704 kWh/Year
Electric Rate
$0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.58frherm
Capacity
2.874
Imet
0.33053
Appliances and Controls
M
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Electric
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
709 kVVh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions