Loading...
HomeMy WebLinkAboutWESTVALE AT JACKSONS GRANT 92 - JGW092 (AS DESIGNED)IECC. 2009 Performance Compliance Property 1265 FRENZEL PKWY CARMEL, IN 46032 Model: CUSTOM Community: WESTVALE AT JACKS( JGWO92 (AS DESIGNED) WESTVALE AT JACKSONS GRANT Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,856 $313 $329 $2,497 $1,417 $0 $3,914 Requirements C-M, Energy Solutions As Designed $1,856 $249 $329 $2,433 $1,417 $0 $3,850 C4405.3 Performance -based compliance passes by 2.5% R402.4.1.2 Air Leakage Testing Air sealing is 5.0[) ACH at 50 Pa. It must not exceed 7.013 ACH at 50 Pa. 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 2.5%. Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name Organization Devin Sielschott TSI Energy Solutions Signature: Date: 8/12119 at 12:53 PM Ekotrope RATER - Version 3.1.0.2231 IECC 2009 Performance compliance results calculated using Eketrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all1iabitityfor the information shown on this report. 1265 FRENZEL PKWY CARMEL, IN 46032 Builder: HOMES BY McKENZIE, INC. Ceiling Attic, R-50 Above Grade Walls R-15 Foundation Walls R-11 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.29, SHGC: 0.27 Building Features Duct Supply R-6.0, Return R-20.0 Duct Leakage to Outside 232 CFM25 (3.94 / 100 s.f.) Total Duct Leakage 464 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric - 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 8/12119 at 12:53 PM Ekotrope RATER - Version 3.1.0.2231 2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 1265 FRENZEL PKWY TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: WESTVALE AT JACKS( Builder HOMES BY McKENZIE, JGW092 (AS DESIGNED) INC. WESTVALE AT JACKSONS GRANT General Building Information Conditioned Area (sq ft) 5,883 Conditioned Volume (cubic ft) 59,407 Insulated Shell Area (sq ft) 11,921 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT(2,770 s.f., 233 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. ] Name: CRAWL(343 s.f., 47 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall ] Name: FIN (Exterior Perimeter [ft]: 192, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 10.595 Fully insulated (top to bottom) 1] Name: UNFIN (Exterior Perimeter [ft]: 42, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) J--1 R:0.00 Fully insulated (top to bottom) 1� Name: CRAWLIAMB (Exterior Perimeter [ft]: 47, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2) 1-� R: 10.00 Fully insulated (top to bottom) Above Grade Wall 1 Energy Code Inspection Checklist Property Organization 1265 FRENZEL PKWY TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: WESTVALE AT JACKS( Builder HOMES BY McKENZIE, JGWO92 (AS DESIGNED) INC. WESTVALE AT JACKSONS GRANT Name: CONDIAMB (2,508 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CON DIGAR (480 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CON DIATTIC (179 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist 1� Name: RIM CONDIAMB (233 s.f.) 1--1 R:11.691 Roof Name: CONDIGAR (48 s.f.) R: 11.691 Name: MAIN (3,113 s.f.) R-39.73 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door 1� Name: GARAGE (48 s.f.) 1--1 U:0.182 El Name: GARAGE (24 s.f.) U: 0.182 Glazing Inspection Status Results are projected 11 Name: FRONT (58 s.f.), U: 0.290, SHGC: 0.27, Orientation: EAST C", Energy Solutions 2 Energy Code Inspection Checklist 7'SI Energy Solutions Property Organization Inspection Status 1265 FRENZEL PKWY TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: WESTVALE AT JACKS[ Builder HOMES BY McKENZIE, JGW092 (AS DESIGNED) INC. WESTVALE AT JACKSONS GRANT Name: BACK (194 s.f.), U: 0.290, SHGC: 0.27, Orientation: WEST E] Name: LEFT SIDE (125 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH E] Name: GD (20 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH [] Name: RIGHT SIDE (123 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH El Name: GO (24 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH El Name: RIGHT SIDE BSMT (55 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH 1I Name: LEFT SIDE BSMT (55 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 1 HEATING 1 - Natural Gas - 100% Heating Load @ 92.1 AFUE AC 1 - Electric - 100% Cooling Load @ 13 SEER 0 Water Heating • Electric - 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4,951 CFM50 (5.00 ACH50) or less at final blower -door test. 3 Energy Code Inspection Checklist Property Organization Inspection Status 1265 FRENZEL PKWY TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: WESTVALE AT JACKS( Builder HOMES BY McKENZIE, JGW092 (AS DESIGNED) INC. WESTVALE AT JACKSONS GRANT Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC. Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 232 CFM25 (3.94 / 100 s.f.) Total Leakage specified as: 464 CFM25 (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM251 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Energy Solutions Inspection Status C-M 1265 FRENZEL PKWY TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model- CUSTOM Community: WESTVALE AT JACKSONS GRANT 92 Builder HOMES BY MCKENZIE, INC. JGW092 [AS DESIGNED] WESTVALE AT JACKSONIS GRANT 92 General Building Information Number Of Bedrooms 3 Number Of Floors 1 Conditioned Floor Area [sq_ ft.] 5,883 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 59,407 Total Units in Building 1 Residence Type Single family detached Floor Number Model CUSTOM Community 1NESTVALE AT JACKSONS GRANT 92 Climate Zone 5A Foundation Wall Name Library type Height Above Grade Depth Below Grade Perimeter Location Enclosing CRAWUAMB R-10 Draped, Full 1 2 47 Exposed Exterior Conditioned Crawlspace FIN R-13 Finished, G1 1 8 192 Exposed Exterior Conditioned Space UNFIN Uninsulated 1 8 42 Exposed Exterior Conditioned Space Foundation Wall Library List. Name Feet From Wall TOTo Feet From Wall Top To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulation value Top Bottom R-10 Draped, Full N-A NIA Yes NIA NIA 10.00 R-13 Finished, G1 NIA NIA Yes NIA NIA 10.595 Uninsulated NIA NIA Yes NIA NIA 0.00 Name Library type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 233 Below Grade 0 0 2,770.0 ft' Exposed Exterior Conditioned Space CRAWL Uninsulated 47 Below Grade 0 0 343.0 ft Exposed Exterior Conditioned Crawlspace 1 Building Summary Property Organization C-MEnergy Solutions Inspection Status 1265 FRENZEL PKWY TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model- CUSTOM Community: WESTVALE AT JACKSONS GRANT 92 Builder HOMES BY McKENZIE, INC. JGW092 [AS DESIGNED] WESTVALE AT JACKSONIS GRANT 92 Slab Library List Name Wall Construction Slab Completel�r Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [It] Insulation R Value Uninsulated Wood Frame I Other No 0 0 ❑ No 000 Framed Floor M None Present Framed Floor Library List Ir None Present Rim Joist Name Library Type Surface Area Location CONDIGAR G1 R-15, OSB 48.0 ft' Unconditioned, attached garage RIM CONDIAMB G1 R-15, OSB 233.0 ft' Exposed Exterior Rim Joist Library List Name Effective Insulation R-value G1 R-15: OSB 11.691 all J Name Library Type Surface Color Surface Area Location CONDIAMB G1 R-15 BATT, OSB Medium 2,508.0 ft' Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 1790 ft' Attic Building Summary Property Organization 1265 FRENZEL PKWY TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model- CUSTOM Community: WESTVALE AT JACKSONS GRANT 92 Builder HOMES BY McKENZIE, INC. JGW092 [AS DESIGNED] WESTVALE AT JACKSONS GRANT 92 Name Library Type CONDIGAR G1 R-15 Gar Walls Wall Library List Name Effective R-value G1 R-15 BATT. OSB 13.423 G1 R-t 5 Gar Walls 11 972 Glazing C-M Energy Solutions Inspection Status Results are projected Surface Color Surface Area Location Medium 480.0 fts Unconditioned. attached garage Name BACK Library Type Wall Assignment U-.29, SHGC-.27 CONDIAMB Foundation Wall Assignment Overhang Depth 0 Overhang Ft To Top 0 Overhang Ft To ottom 0 Orientation West Surface Area 194.GTF FRONT U-29, SHGC-.27 CONDIAMB 0 0 0 East 58.0ft2 GD U-29, SHGC-27 CONDIAMB 0 0 0 South 20.0ft2 GD U-29, SHGC-27 CONDIAMB 0 0 0 North 24.0ft2 LEFT SIDE U-29, SHGC-27 CONDIAMB 0 0 0 South 125.0ft2 LEFT SIDE BSMT U-29, SHGC-27 FIN 0 0 0 South 55.0ft2 RIGHT SIDE U-29, SHGC-27 CONDIAMB 0 0 0 North 123.0ft' RIGHT SIDE BSMT U-29, SHGC-27 FIN 0 0 0 North 55.Dfts Glazing Library List Name U-29, SHGC-27 Shgc C.27 0290 Building Summary Property Organization 1265 FRENZEL PKWY TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model- CUSTOM Community: WESTVALE AT JACKSONS GRANT 92 Builder HOMES BY McKENZIE, INC. JGW092 [AS DESIGNED] WESTVALE AT JACKSONS GRANT 92 Skylight Skylight Library List None Opaque Door Name Library Type Wal I Assi g n meni GARAGE Fiberglass/Steel CONDIGAR Door GARAGE Fiberglass/Steel CONDIGAR Door Opaque Door Library List -in Name E FiherglasslSteel Door Roof Insulation Name MAIN R-5n Rlnwn C P1 Assignment 01132 C-M Energy Solutions Inspection Status Results are projected nce sonar surrace uoior surrace Area Locanor Absorptan oe 0.9 0.75 Medium 48.0 fts Exposed Exterior 0.9 0.75 Medium 24.0 fts Exposed Exterior 3.113 No Medium 3,113.0 fl- Attic Roof Insulation Library List Name Has Radiant Barrier R-50 Blown, GR1 `Jc Effective R-value 50.474 4 Building Summary Property Organization Inspection Status 1265 FRENZEL PKWY TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model- CUSTOM Community: WESTVALE AT JACKSONS GRANT 92 Builder HOMES BY MCKENZIE, INC. JGW092 [AS DESIGNED] WESTVALE AT JACKSQNS GRANT 92 Whole House Infiltratio Iiiiiiiiiiiir Infiltration Measurement type Shelter Class 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation None Present Lighting °I Interior Fluorescent % Interior LED Lighting Lighting 0 p 4 C-M, Energy Solutions % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting 0 0 a a Onsite Generation None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present 5 Building Summary Property Organization 1265 FRENZEL PKWY TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model- CUSTOM Community: WESTVALE AT JACKSONS GRANT 92 Builder HOMES BY MCKENZIE, INC. JGW092 [AS DESIGNED] WESTVALE AT JACKSONS GRANT 92 Conditioning Equipment Name Literary type Heating Percent Ldac AC 1 13ACX-042-230 0% HEATING 1 912SA48100S17 100% Water Heatinq ENT 50 100 0% quipment Type: 13ACX-042-230 C-M Energy Solutions Inspection Status Results are projected ng Percent Load Hot Water Percent LOad LCCaliOn 100% 0% Conditioned Space 0% 0% Conditioned Space 0% 100% Conditioned Space Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 41.5 Equipment Type: 9125A4810051L Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 93 Use default EAE No EAE [kWh] 756 Equipment Type: ENT 50 100 Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Building Summary Property Organization 1265 FRENZEL PKWY TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model- CUSTOM Community: WESTVALE AT JACKSONS GRANT 92 Builder HOMES BY MCKENZIE, INC. JGW092 [AS DESIGNED] WESTVALE AT JACKSONS GRANT 92 Distribution System Distribution Type Forced Air Heating Equipment HEATING 1 Cooling Equipment AC 1 Sq. Feet Served 5883 # Return Grilles 3 Supply Duct R Value 6 Return Duct R Value 20 Supply Duct Area [ft2] 1588.41 Return Duct Area [ft2] 882.45 Leakage to Outdoors 232 CFM25 (3.941 100 s.f.) Total Leakage 464 CFM25 Total Leakage Dud Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Attic (well vented, under insulation) Percent Supply Area ❑ Percent Return Area 50 Duct 2 Duct Location Conditioned Space Percent Supply Area 100 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 1265 FRENZEL PKWY CARMEL, IN 46032 Model- CUSTOM Community: WESTVALE AT JACKSONS GRANT 92 JGW092 [AS DESIGNED] WESTVALE AT JACKSONS GRANT 92 Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 75 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.617 Field Utilization Timer Controls asher WVWV Label Energy Rating 704 kWh/Year Electric Rate $0.081kWh Annual Gas Cost $23.00 Gas Rate $0.58frherm Capacity 2.874 Imet 0.33053 Appliances and Controls M Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Electric Convection Oven? No Induction Range? No Refrigerator Consumption 709 kVVh/Year Inspection Status Results are projected C-M, Energy Solutions