HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance
Property Organization
7031 PICKETT PL TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: ASTORIA Michael Hill
Community: THE GROVE AT LEGA[
Builder
GL085 (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 85
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
51,322
5210
5324
$1,855
5659
s0
$2,514
Requirements
C-M,
Energy Solutions
As Designed
S1,217
S157
S324
$1,699
S559
SO
$2,358
C4405.3 Performance -based compliance passes by 8.4%
R402.4.12 Air Leakage Testing Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U-Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 8.4%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
8114/19 at 3:38 PM
Ekotrope RATER - Version 3.1.0.2233
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
7031 PICKETT PL
CAR M E L, IN 46033
Builder: PYATT BUILDERS, LLC
IMFM14
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 6 ACH50
Window U-Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-25.0, Return R-25.0
Duct Leakage to Outside 120 CFM25 (4.81 1100 s.f.)
Total Duct Leakage 256 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date: 8114119 at 3:38 PM
Ekotrope RATER - Version 3.1.0.2233
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
7031 PICKETT PL TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: ASTORIA Michael Hill
Community: THE GROVE AT LEGA[
GL085 (AS DESIGNED)
THE GROVE AT LEGACY 85
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Builder
PYATT BUILDERS, LLC
2,497
23,556
6,633
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: 3LAB(1,790 s.f., 191 ft. exterior perimeter)
R-10 perimeter insulation, R-10 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (1,817 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (350 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (759 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
Energy Code Inspection Checklist
Property
7031 PICKETT PL
CARMEL, IN 46033
Model: ASTORIA
Community: THE GROVE AT LEGA[
GL085 (AS DESIGNED)
THE GROVE AT LEGACY 85
Roof
Name: CONDIAMB (14 s.f.)
R: 11.691
Name: CONDIATTIC (113 s.f.)
R: 11.691
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Name: MAIN (1,790 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f. )
U: 0.182
Glazing
Inspection Status
Results are projected
11 Name: FRONT (36 s.f.), U: 0.310, SHGC: 0.28, Orientation: SOUTH
El Name: BACK(144 s.f.), U: 0.310, SHGC: 0.28, Orientation: NORTH
Name: RIGHT SIDE (70 s.f.), U: 0.310, SHGC: 0.28, Orientation: EAST
E] Name: SLIDER (40 s.f.), U: 0.310, SHGC: 0.28, Orientation: EAST
E] Name: LEFT SIDE (68 s.f.), U: 0.310, SHGC: 0.28, Orientation: WEST
Skylight
None Present
Mechanical Ventilation
None Present
C",
Energy Solutions
2
Energy Code Inspection Checklist
Property Organization inspection Status
7031 PICKETT PL TSI Energy Solutions Results are projected
CARMEL, IN 46033 317-846-4655
Model: ASTORIA Michael Hill
Community: THE GROVE AT LEGA[
Builder
GL085 (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 85
Mechanical Equipment
0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE
M Air conditioner • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 2,356 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 120 CFM25 (4.81 1 100 s.f.)
Total Leakage specified as: 256 CFM25 (Post -Construction)
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property Organization
7031 PICKETT PL TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: ASTORIA Michael Hill
Community: THE GROVE AT LEGA[
Builder
GL085 (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 85
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
7031 PICKETT PL
CARMEL, IN 46033
Model: ASTORIA
Community: THE GROVE AT LEGACY 85
GL085 (AS DESIGNED)
THE GROVE AT LEGACY 85
GeneraFBuilding Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq_ ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Floor Number
Model
Community
Climate Zone
Foundation Wall
Foundation Wall Library List
Slab
Organization Inspection Status
TSI Energy Solutions Results are projected
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
3
2
2;497
Yes
23;556
1
Single family detached
ASTORIA
THE GROVE AT LEGACY 85
5A
None Present
None Present
Masonry Area
C-M,
Energy Solutions
n
SLAB R-10, 1'down, 2' in 191
On Grade 1.23
0 1:790.0 R' Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Slab Completel Underslab Perimeter
Perimeter Thermal Break
Effective R-value
Type Insulated. Insulation
Width [ft] Insulation Depth [ft]
Insulation R Value
R-10, 1'down, 2' in Wood Frame /Other No
2 1
10 No
10.00
Framed Floor
None Present
1
Building Summary
C-M
Energy Solutions
Property Organization Inspection Status
7031 PICKETT PL TSI Energy Solutions Results are projected
CARMEL, IN 46033 317-846-4655
Model: ASTORIA Michael Hill
Community: THE GROVE AT LEGACY 85
Builder
GL085 (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 85
ramed Floor Library Lis#
None Present
Rim Joist
Name Library Type Surface Area Location
CONDIAMB G1 R-15, OSB 14.0 fl' Exposed Exterior
CONDIATTIC G1 R-15, OSB 11310 fF Attic
Rim Joist Library List
Name Effective Insulation R-value
G1 R-15, OSB 11.691
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB
G1 R-15 BATT, OSB
Medium
1.817.0 ft'
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, OSB
Medium
759.0 f['
Attic
CONDIGAR
G1 R-15 Gar Walls
Medium
350.0 ft'
Unconditioned, attached garage
Wall Library List
Name Effective R-value
G1 R-15 BATT, OSB 13.423
IG1 R-15 Gar Walls 11.972
Building Summary
Property
Organization
Inspection Status
Energy
C-M
Solutions
7031 PICKETT PL
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
317-846-4655
Model: ASTORIA
Michael Hill
Community: THE GROVE AT LEGACY 85
Builder
GL085 (AS DESIGNED)
PYATT BUILDERS, LLC
THE GROVE AT LEGACY 85
FGlazin
Name Library Type Wall Assignment Foundation Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK 11-.31, SHGG28
CONDIAMB
0
0
❑
North
144.0 fts
FRONT 11-.31, SHGG28
CONDIAMB
0
0
❑
South
36.0 fF
LEFT SIDE 11-.31, SHGG28
CONDIAMB
0
0
❑
West
68.0 fF
RIGHT SIDE 11-.31, SHGG28
CONDIAMB
0
0
❑
East
70.0 fF
SLIDER U-.31, SHGG28
CONDIAMB
0
0
0
East
40.0 ff
Glazing Library List
Name
Shgc
U {actor
11-.31, SHGC-28
028
0.31 ❑
Skylight
None Present
Skylight Library List
None Present
Opaque Door
Name
Library Type Wall Assignment Foundation Wall
Emittance Solar Surface Color
Surface Area Location
Assignment
Ab sorpta n ce
FRONT
20.0 fC Exposed Exterior
Steel Door CONDIAMB
0.9 0.75 Medium
GARAGE
18.0 fF Exposed Exterior
Steel Door CONDIGAR
0.9 0.75 Medium
Building Summary
Property
7031 PICKETT PL
CARMEL, IN 46033
Model: ASTORIA
Community: THE GROVE AT LEGACY 85
GL085 (AS DESIGNED)
THE GROVE AT LEGACY 85
FOpaque Door Library List
Name
Steel Door
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
V11.1 Tiles
f;1AIN R-38 Blown, GR1 1,790 No Medium 1.790.0 fls Attic
Roof Insulation Library List
Name Has Radiant Barrier Effective R-value
'•0 ? :a l No 38268
Whole House Infiltration
Infiltration Measurement Type
6 ACH at 50 Pa Blower -door tested
Mechanical Ventilation M
None Present
1
Lighting
% Interior Fluorescent % Interior LED Lighting % Exter
Lighting
71 ❑
Shelter Class
4
or Fluorescent % Exterior LED Lighting % Garage Fluorescent
Lighting Lighting
100 0 ❑
4
Building Summary
Property Organization
7031 PICKETT PL TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: ASTORIA Michael Hill
Community: THE GROVE AT LEGACY 85
Builder
GL085 (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 85
rnsite Generation
None Present
Gnsite Generation Library List M
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Inspection Status
Results are projected
C-M,
Energy Solutions
Name
Library Type
Heating Percent Load
Cooling Percent Load
Hot Water Percent Load
Location
Air conditioner
CA13NA036
0%
100%
❑%
Unspecified
Fuel -tired air 9125A48060514 100% 0% ❑% Unspecified
distribution
Water Heating ENT 50 100 0% 0% 100% Unspecified
Equipment Type: 912SA48060S14
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 58
Use default EAE No
EAE [kWh] 528
A
Building Summary
Property
7031 PICKETT PL
CARMEL, IN 46033
Model: ASTORIA
Community: THE GROVE AT LEGACY 85
GLG85 (AS DESIGNED)
THE GROVE AT LEGACY 85
■
quipment Type:
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
GA13NA036
..1JJff -------
Equipment Type: ENT 50 100
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Electric
Forced Air
PSG (Single Speed)
13 SEER
34.2
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
❑.99
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
7031 PICKETT PL
CARMEL, IN 46033
Model: ASTORIA
Community: THE GROVE AT LEGACY 85
GLG85 (AS DESIGNED)
THE GROVE AT LEGACY 85
1butivn System
Lion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
]uct R Value
Xct Area r]
]uct Area [ft2]
5 to Outdoors
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Cfm Per Watt
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Forced Air
Fuel -fired air distribution
Air conditioner
2497
2
25
25
674.19
249.7
120 CFM25 (4.81 1 100 s.f.)
256 CFM25
Post -Construction
Yes
Attic (well vented; under insulation)
95
95
Conditioned Space
5
5
Attic (well vented)
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
7031 PICKETT PL
CARMEL, IN 46033
Model: ASTORIA
Community: THE GROVE AT LEGACY 85
GLG85 (AS DESIGNED)
THE GROVE AT LEGACY 85
ater Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
L -A
Standard
No
45
No
No
20
No
Electric
Timer Controls
ff"W
704 kWh/Year
0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
"M �
Inspection Status
Results are projected
C-M,
Energy Solutions
,�