HomeMy WebLinkAboutM101 Mechanical PlanHVAC UNIT SCHEDULE HEATING SECTION Roof Top Units (RTU's) Provided by Landlord SUPPLY FAN COOLING SECTION ELECTRICAL DATA NATURAL GAS GENERAL SUPPLY OUTSIDE EXT. S.P. SEER TOTAL INPUT OUTPUT MIN.CKT. M.O.P. SERVICE CFM AIR CFM IN W.G. CAP. STUN BTUH AMPS. AMPS. HVAC-1 EXISTING IO TON SPLIT SYSTEM 4000 800 - 11 120.000 200.000 160.000 - - 27714803PH DIFFUSER AND GRILLE SCHEDULE ML:UHANIUAL SYMbULS eA/C UNIT NUMBER SYMBOL MAKE MODEL NO. BOOT NECK CEILING PE eF1 EXHAUST FAN NUMBER A ® PRICE BCD 4WAY WI INSULATED BOOT AS STATED T-BAR e DIFFUSER TYPE INDICATES CFM QUANTITY S IS SMOKE DETECTOR MOUNTED IN THE RETURN B • TITUS R-OMNI SEE DUCT SIZE BOTTOM s PLENUMS OF HVAC UNITS. SUPPLY AIR ADJUSTABLE ROUND OF DUCT FLEXIBLE DUCT STARTING COLLAR WITH VOLUME CONTROL DAMPER C O SUPPLY AIR PRICE MODEL 640 20%5 SIDEWALL OF DUCT FLEXIBLE DUCT WITH INSULATION NUMBER DENOTES INSIDE DIAMETER D PRICE 530 W/ INSULATED BOOT 10"X10" T-BAR s1 EMERSON 1F97-1277 or EQUIVALENT HONEYWELL EQUIVALENT AUTOMATIC CHANGEOVER THERMOSTAT EXHAUST AIR (NUMBER INDICATES HVAC NUMBER.) CONNECT TO EXISTING MAIN IN AREA RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel ja,GsjUai DATE: 09/04/19 MAKE - MODEL I COMMENTS )ESIG.I SERVES I CFMI SP HEPLECSERVICE DRIVE I MANUF./MODEL BS) IWEIG EF-1 RESTROOM 150 NA 12M11 ph DO NUTONE QTXEN150 4 EF-2 RESTROOM 150 NA 12M/lph DO NUTONE DTXENiSD 4 ALL OTHER DUCTWORK THROUGHOU- SPACE IS EXISTING TO REMAIN. CLEAN AND PREP TO BE PAINTED. DUCTWORK & AIR DISTRIBUTION NOTES 1, ALL DUCTV✓IXM SHALL BE INSTALLED STRAIGHT AND TRUE IN A QUALITY 8, HVAC CONTRACTOR SHALL HELD ROUTE DUCTWORKAS REQUIRED TO WORKMANLIKE FASHION. AVOID INTERFERENCE WITH SUSPENDED ACOUSTICAL CEILING HEIGHT. COORDINATE WITH GENERAL CONTRACTOR. 2, ALL DUCTWORK SHALL CONFORM TO ASHRAE AND SMACNA STANDARDS WITH REGARDS TO DUCT GAUGES, TURNING VANES, THE INSTALLATION OF 10, ALL ELECTRICAL FIXTURES SHALL BE PROVIDED BY THE ELECTRICIAN, THE TURNING VANES AND)OR EXTRACTORS, AND MOUNTED AND BRACING. AND INSTALLED BY THE EIECTRIGM. CONTRACTOR, UNLESS OTHERWISE RECTANGULAR DUCT CONSTRUCTION NOTED, SEE E101. E26 GALVANIZED IRON PER SMACNA it FOR SYMBOLS SHOWN IN LEGEND. BUT NOT ON THE PLAN, REFER TO THE MECH. AND EMC. DRAWINGS. DUCT WIDTH US, STD BRACING INCHES IN INCHES GAUGE GALV. MGM SPACING 12, EACH UNIT SHALL PROVIDE IONIZATION TYPE RETURN AIR DUCT SMOKE 1-12 26 Ga - - DETECTION. 13-24 24 Ga, - - RKS 25-W 24 Ga. 1 x 1 x V8 48 13, SMOKE DETECTION SYSTEM WILL CONSIST OF IONIZATION TYPE SAMPLING TUBE. SMOKE DETECTOR WITH AUDIBLE ALARM, LED INDICATOR, AND MANUAL 31-40 22 Ga. 1 x 1 x V8 48 41-60 22 Ga. 1114x 1114x V8 24 61-90 MGa. 1V2x1 V2x 118 24 TEST/TRIPKEY. VENTING NOTES: TO SWITCH TO SWITCH 91-OVER 18 Ga. 1Va1 V2x V8 A 1, ALL GAS FIRED APPLIANCE VENTING SHALL COMPLY WITH STATE AND 3. STEEL OR ALUMINUM DUCTWORK SHALL CONFORM WITH DEFT OF LOCAL CODES AND BE DONE IN A QUALITY WORKMANLIKE FASHION. COMMERCE CHAPTER 63.29(3) AND 64.34OML AS WELL AS SMACNA SEAL CLASS-C. FRESH AIR DUCTWORK. AND ANY DUCTWORK EXTERIOR OF THE 2, ALL VENTING SHALL STRICTLY COMPLYWITH MANUFACTURER'S BUILDING SHALL BE INSULATED WITH MATERIAL NO LESS THAN R9, RECOMMENDATIONS AND INSTRUCTIONS. SUPPLYAIR DUCTNORK NOT IN THE CONDITIONED SPACE SHALL BE INSULATED WITH MATERIAL NO LESS THAN RE. 3, ALL FRESH AIR INTAKES SHALL BE A MINIMUM OF 10' AWAY FROM ANY EXHAUST VENT, SOIL VENT PIPE, OR GAS METER, 4, THE HVAC CONTRACTOR SHALL CONSULT WITH THE GENERAL CONTRACTOR ANDI OR THE BUILDING OWNER(S) TO DETERMINE THE EXACT 4, ALL GAS FIRED APPLIANCE VIEWS SHALL BE A MINIMUM OF 10'-0 AWAY LOCATION OF REGISTERS,GRILLES, AND DIFFUSERS. HVAC DRAWINGS FROM MY WINDOW,DOOR, OR BUILDING ENTRANCE.PND MANUAL TEST/TRIP INDICATE QUANTITES AND AIR ROW SPECIFICATIONS, HOWEVER LOCATIONS KEY, ARE DIAGRAMMATIC. GAS PIPING NOTES; 5, THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR BALANCING THE ENTIRE SYSTEM SO THAT THE SUPPLY AIR, RETURN AIR, EXHAUST AIR, AND 1, ALL GAS PIPING SHALL BE RUN STRAIGHT AND TRUE AND BE INSTALLED IN FRESH AIR PRE WITHIN NE% OF THE AIR QUANTITIES SHOWN ON THE PLAN. A QUALITY WORKMANLIKE FASHION. THE HVAC CONTRACTOR SHALL FURNISH THE HVAC DESIGNER WITH TWO COPIES OF THE BALANCE DATA 2, GAS PIPING SHALL CONFORM TOALL STATE AND LOCAL CODES, AS WELL AS NATIONAL FUEL GAS CODE RECOMMENDATIONS. 6. INSULATED FLEXIBLE SUPPLY AIR DUCT RUNS SHALL NOT EXCEED FIVE (5) FEET IN LENGTH. 3. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL SCHEDULE 40 STEEL GAS PIPING AND FITTINGS. HVAC CONTRACTOR SHALL INSTALL ALL 7, HVAC CONTRACTOR SHALL FURNISH AND INSTALL PLEATED FILTERS WITH NECESSARY VALVES,FITTINGS,REGULATORS, AND SAFETY AND OPERATING AN AVERAGE ARRESTANCE OF 85% OR GREATER, OR HIGHER EFFICIENT DEVICES. FILTER MEDIA TYPES. FILTERS SHALL BE EASILY ACCESSIBLE IN FILTER RACK OR FILTER GRILLES. MECHANICAL PLAN SCALE: 1/4" = 1'-0" U J J ICU 0 O U .N 0 H-+ NN� cof 758048th Street, S.E. Grand Rapids, Mi. 49512 P. 616.634.2263 Glenn@rdo-llc.c cm 73 1 m N U O (aOt9 t N qCT CD Z F— a> — m�Iv UCO E m Ln U v IL J O VA osi DATE ISSUED FOR: 0612WO19 Construction . Q�OtSTEy�Q .. i No. AR11000167 "yiyygrRCHne iTEGSsaoG: lan THIS DRAWING IS THE SOLE PROPERTY OF RETAIL DESIGN CONSULTANTS LLC AND IS A COPYRIGHTED DOCUMENT AND IS NOT TO BE USED OR REPRODUCED WITHOUT WRITTEN CONSENT. M101