HomeMy WebLinkAboutM101 Mechanical PlanHVAC UNIT SCHEDULE
HEATING SECTION
Roof Top Units (RTU's) Provided by Landlord
SUPPLY FAN
COOLING SECTION
ELECTRICAL DATA
NATURAL GAS
GENERAL
SUPPLY
OUTSIDE
EXT. S.P.
SEER
TOTAL
INPUT
OUTPUT
MIN.CKT.
M.O.P.
SERVICE
CFM
AIR CFM
IN W.G.
CAP.
STUN
BTUH
AMPS.
AMPS.
HVAC-1 EXISTING IO TON SPLIT SYSTEM
4000
800
-
11
120.000
200.000
160.000
-
-
27714803PH
DIFFUSER
AND GRILLE
SCHEDULE
ML:UHANIUAL
SYMbULS
eA/C
UNIT NUMBER
SYMBOL
MAKE MODEL NO.
BOOT NECK
CEILING
PE
eF1
EXHAUST FAN NUMBER
A
®
PRICE BCD 4WAY WI
INSULATED BOOT
AS STATED
T-BAR
e
DIFFUSER TYPE
INDICATES CFM QUANTITY
S IS
SMOKE DETECTOR MOUNTED IN THE RETURN
B •
TITUS R-OMNI
SEE DUCT SIZE
BOTTOM
s
PLENUMS OF HVAC UNITS.
SUPPLY AIR
ADJUSTABLE ROUND
OF DUCT
FLEXIBLE DUCT STARTING COLLAR WITH VOLUME
CONTROL DAMPER
C O
SUPPLY AIR
PRICE MODEL 640
20%5
SIDEWALL
OF DUCT
FLEXIBLE DUCT WITH INSULATION
NUMBER DENOTES INSIDE DIAMETER
D
PRICE 530 W/
INSULATED BOOT
10"X10"
T-BAR
s1
EMERSON 1F97-1277 or EQUIVALENT HONEYWELL
EQUIVALENT AUTOMATIC CHANGEOVER THERMOSTAT
EXHAUST AIR
(NUMBER INDICATES HVAC NUMBER.)
CONNECT TO EXISTING
MAIN IN AREA
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Camel
ja,GsjUai
DATE: 09/04/19
MAKE - MODEL I COMMENTS
)ESIG.I SERVES I CFMI SP HEPLECSERVICE DRIVE I MANUF./MODEL BS)
IWEIG
EF-1 RESTROOM 150 NA 12M11 ph DO NUTONE QTXEN150 4
EF-2 RESTROOM 150 NA 12M/lph DO NUTONE DTXENiSD 4
ALL OTHER DUCTWORK THROUGHOU-
SPACE IS EXISTING TO REMAIN. CLEAN
AND PREP TO BE PAINTED.
DUCTWORK & AIR DISTRIBUTION NOTES
1, ALL DUCTV✓IXM SHALL BE INSTALLED STRAIGHT AND TRUE IN A QUALITY
8, HVAC CONTRACTOR SHALL HELD ROUTE DUCTWORKAS REQUIRED TO
WORKMANLIKE FASHION.
AVOID INTERFERENCE WITH SUSPENDED ACOUSTICAL CEILING HEIGHT.
COORDINATE WITH GENERAL CONTRACTOR.
2, ALL DUCTWORK SHALL CONFORM TO ASHRAE AND SMACNA STANDARDS
WITH REGARDS TO DUCT GAUGES, TURNING VANES, THE INSTALLATION OF
10, ALL ELECTRICAL FIXTURES SHALL BE PROVIDED BY THE ELECTRICIAN,
THE TURNING VANES AND)OR EXTRACTORS, AND MOUNTED AND BRACING.
AND INSTALLED BY THE EIECTRIGM. CONTRACTOR, UNLESS OTHERWISE
RECTANGULAR DUCT CONSTRUCTION
NOTED, SEE E101.
E26
GALVANIZED IRON PER SMACNA
it FOR SYMBOLS SHOWN IN LEGEND. BUT NOT ON THE PLAN, REFER TO THE
MECH. AND EMC. DRAWINGS.
DUCT WIDTH US, STD BRACING INCHES
IN INCHES GAUGE GALV. MGM SPACING
12, EACH UNIT SHALL PROVIDE IONIZATION TYPE RETURN AIR DUCT SMOKE
1-12 26 Ga - -
DETECTION.
13-24 24 Ga, - -
RKS
25-W 24 Ga. 1 x 1 x V8 48
13, SMOKE DETECTION SYSTEM WILL CONSIST OF IONIZATION TYPE SAMPLING
TUBE. SMOKE DETECTOR WITH AUDIBLE ALARM, LED INDICATOR, AND MANUAL
31-40 22 Ga. 1 x 1 x V8 48
41-60 22 Ga. 1114x 1114x V8 24
61-90 MGa. 1V2x1 V2x 118 24
TEST/TRIPKEY.
VENTING NOTES:
TO SWITCH
TO SWITCH
91-OVER 18 Ga. 1Va1 V2x V8 A
1, ALL GAS FIRED APPLIANCE VENTING SHALL COMPLY WITH STATE AND
3. STEEL OR ALUMINUM DUCTWORK SHALL CONFORM WITH DEFT OF
LOCAL CODES AND BE DONE IN A QUALITY WORKMANLIKE FASHION.
COMMERCE CHAPTER 63.29(3) AND 64.34OML AS WELL AS SMACNA SEAL
CLASS-C. FRESH AIR DUCTWORK. AND ANY DUCTWORK EXTERIOR OF THE
2, ALL VENTING SHALL STRICTLY COMPLYWITH MANUFACTURER'S
BUILDING SHALL BE INSULATED WITH MATERIAL NO LESS THAN R9,
RECOMMENDATIONS AND INSTRUCTIONS.
SUPPLYAIR DUCTNORK NOT IN THE CONDITIONED SPACE SHALL BE
INSULATED WITH MATERIAL NO LESS THAN RE.
3, ALL FRESH AIR INTAKES SHALL BE A MINIMUM OF 10' AWAY FROM ANY
EXHAUST VENT, SOIL VENT PIPE, OR GAS METER,
4, THE HVAC CONTRACTOR SHALL CONSULT WITH THE GENERAL
CONTRACTOR ANDI OR THE BUILDING OWNER(S) TO DETERMINE THE EXACT
4, ALL GAS FIRED APPLIANCE VIEWS SHALL BE A MINIMUM OF 10'-0 AWAY
LOCATION OF REGISTERS,GRILLES, AND DIFFUSERS. HVAC DRAWINGS
FROM MY WINDOW,DOOR, OR BUILDING ENTRANCE.PND MANUAL TEST/TRIP
INDICATE QUANTITES AND AIR ROW SPECIFICATIONS, HOWEVER LOCATIONS
KEY,
ARE DIAGRAMMATIC.
GAS PIPING NOTES;
5, THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR BALANCING THE
ENTIRE SYSTEM SO THAT THE SUPPLY AIR, RETURN AIR, EXHAUST AIR, AND
1, ALL GAS PIPING SHALL BE RUN STRAIGHT AND TRUE AND BE INSTALLED IN
FRESH AIR PRE WITHIN NE% OF THE AIR QUANTITIES SHOWN ON THE PLAN.
A QUALITY WORKMANLIKE FASHION.
THE HVAC CONTRACTOR SHALL FURNISH THE HVAC DESIGNER WITH TWO
COPIES OF THE BALANCE DATA
2, GAS PIPING SHALL CONFORM TOALL STATE AND LOCAL CODES, AS WELL
AS NATIONAL FUEL GAS CODE RECOMMENDATIONS.
6. INSULATED FLEXIBLE SUPPLY AIR DUCT RUNS SHALL NOT EXCEED FIVE (5)
FEET IN LENGTH.
3. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL SCHEDULE 40
STEEL GAS PIPING AND FITTINGS. HVAC CONTRACTOR SHALL INSTALL ALL
7, HVAC CONTRACTOR SHALL FURNISH AND INSTALL PLEATED FILTERS WITH
NECESSARY VALVES,FITTINGS,REGULATORS, AND SAFETY AND OPERATING
AN AVERAGE ARRESTANCE OF 85% OR GREATER, OR HIGHER EFFICIENT
DEVICES.
FILTER MEDIA TYPES. FILTERS SHALL BE EASILY ACCESSIBLE IN FILTER RACK
OR FILTER GRILLES.
MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
U
J
J
ICU
0
O
U
.N
0
H-+
NN�
cof
758048th Street, S.E.
Grand Rapids, Mi. 49512
P. 616.634.2263
Glenn@rdo-llc.c cm
73
1
m N
U O
(aOt9
t N qCT
CD Z
F— a> —
m�Iv
UCO E
m
Ln
U
v
IL
J
O
VA
osi
DATE ISSUED FOR:
0612WO19 Construction
. Q�OtSTEy�Q ..
i No. AR11000167
"yiyygrRCHne iTEGSsaoG:
lan
THIS DRAWING IS THE
SOLE PROPERTY OF
RETAIL DESIGN
CONSULTANTS LLC AND IS
A COPYRIGHTED
DOCUMENT AND IS NOT
TO BE USED OR
REPRODUCED WITHOUT
WRITTEN CONSENT.
M101